• Title/Summary/Keyword: Solar Thermal Apartment

Search Result 47, Processing Time 0.02 seconds

A Study on Characteristics of Heat Storage and Emission of Apartment Structures in Winter Season (겨울철 난방시 아파트 구조체의 축방열 특성에 대한 연구)

  • Cho, Keun-Je;Chang, Hyun-Jae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.208-213
    • /
    • 2011
  • In the former study, it is obtained that thermal storage effect of the apartment structure is the disadvantage to maintain comfort indoor thermal environment. However, because the thermal storage effect can be changed of its aspect in heating season, field measurement at the same apartment with the measurement in summer season was conducted in winter season. As results, thermal storage effect of apartment structure was the disadvantage in winter season, too.

  • PDF

Feasibility of a Solar Thermal Organic Rankine Cycle Power Plant for an Apartment Complex with Aspen Plus® (ASPEN PLUS®를 이용한 태양열 유기랭킨사이클 열병합 발전시스템의 공동주택 적합도 분석)

  • Im, Seokyeon;Kim, Hyung-Geun;Yu, Sangseok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.4
    • /
    • pp.317-324
    • /
    • 2015
  • In this study, a solar thermal system is designed to provide hot water and electricity for improvement of solar thermal energy availability in an apartment complex. The electricity is generated with Organic Rankine Cycle (ORC) by the solar thermal energy. R134a, R141b and R245fa are selected for operating fluid of the solar thermal ORC system. ORC with R245fa shows the best performance based on the variation of pressure. The irreversibility of component showed that the technology advance of the evaporator ensures a performance improvement. The sensitivity study results indicate that the turbine performance is most effective way to improve the performance of ORC system. An economic analysis showed that approximately 50% more income could be achieved by a solar thermal ORC system with a hot water supply.

Thermal Performance Analysis of Hybrid heat Supply System for Zero Carbon Green Home (제로카본 그린홈 구현을 위한 하이브리드 열공급 시스템의 열성능 분석)

  • Joo, Hong-Jin;Lee, Kyoung-Ho;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.53-59
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000kcal/hr, a $0.15m^3$ hot water storage tank for space heating, a evacuated tubular solar collector $3.74m^2$ of aperture area at the $20^{\circ}$ install angle, a $0.3m^3$ hot water storage tank. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.

An Experimental Study on the Solar Collector Efficiency for Apartment Building (공동주택의 태양열 집열기 효율에 대한 실험적 연구)

  • Choi, Byungdo;Kim, Miyeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.130.2-130.2
    • /
    • 2011
  • The application of solar energy in residential building is general and natural in today. And application methods of solar thermal energy is divided in two kind of form, single evacuated tube and flat-plate form. Then in this study, the efficiency of single evacuated tube and flat-plate system is compared by total and effective area considering the time receiving the solar radiation between 24 hours and the specific time(10:00~15:00). As a result of the experiment, single evacuated tube and flat-plate collector's efficiency is varied by the quantity of solar radiation. And especially, the flat-plate system is more affected by outdoor temperature. Therefore the application of solar thermal system should be considered the solar radiation and outdoor temperature.

  • PDF

A Study on the Optimal Distance and Heating Energy with relation to Site Planning of Apartment Building (아파트 배치형태에 따른 적정 인동거리와 난방에너지에 대한 연구)

  • Jung, Doo-Woon;Choi, Chang-Ho;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.97-107
    • /
    • 2003
  • Recently, the apartment building has been constructed in large quantities to provide housings due to the gravitation of population towards large cities. However, we're faced with a critical problem of deterioration of our dwelling environment caused by the trend toward high-rise apartment which could be an obstruction in obtaining sufficient sunlight. Therefore, there have been several legislative actions against infringement on the right of sunshine. In the building law, sunshine hours and the minimal separated distance between apartments are regulated as the criteria for the site planning, However, the minimal separated distance was defined without consideration of the parameters like building orientation and thermal effect of the sunshine hours in the site planning for the apartment building. In this study, the sunshine hours and heating energy during the underheated season for various arrangements in site planning are carefully considered and analyzed.

The investigation into the standards and performances of domestic and foreign windows for an apartment house (국내외 공동주택용 창호의 기준 및 성능 조사)

  • Song, Su-Bin;Kim, Young-Tag;Yoon, Seong-Kon;Yoon, Seong-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.330-335
    • /
    • 2008
  • This research aims to investigate the standards and the performances of domestic and foreign windows for and apartment house and to present fundamental data for selecting the optimum window at the step of designing an apartment house. To compare the performances of domestic and foreign windows it is selected 5 major window companies in and 3 major window companies in Japan, and investigated window structure, material, type of opening and closing, window glass and the performances of windows for an apartment house-closing and opening force, repeated closing and opening, thermal resistance, sound transmission loss, air tightness, water tightness, wind resistance. The result of a comparative analysis show that the average thermal resistance of Korean window is higher than Japan's but the average sound transmission loss and water tightness of Korean window is lower than Japan's and the rest of the performances is similar.

  • PDF

A Comparative Analysys of Window Energy Performance According to the Difference Between Actual size and Standard size (창호의 성능인증 규격 기준과 면적 변화에 따른 에너지성능 비교분석)

  • Kim, Seong-Beom;Lee, Su-Yeul;Kim, Dong-Yoon;Choi, Won-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.1
    • /
    • pp.49-60
    • /
    • 2020
  • This study reviewed selected specific windows and reviewed the window performance certification criteria including KS F 2278 and KS L 9107 and analyzed the change in performance based on the change of area. This study also compared the heating and cooling loads of an apartment house applied with window performance reviewed in consideration of insulation and SHGC performance and actual size based on KS F 2278. The analyzed window was a double window composed of aluminum and PVC and the building was the apartment house model of 141 ㎡. The analysis results were as follows. First, as the window glass's thermal performance is superior to frame, the performance degraded in reduced area. In case of selected window, the 1 m × 1m window's thermal performance and SHGC decreased by 35% and 37% respectively compared to 2 m × 2 m window. Secondly, in the comparison of performance for increasing area with 2 m × 2 m and 3 m × 3 m windows, the 3 m × 3 m window's thermal performance and SHCG increased about 14%. Third, in the comparison of heating and cooling loads of the analyzed model considering the apartment house model applied with window performance derived from KS F 2278 and actual figures, the model's total heating and cooling loads increased by 33% with cooling decreasing by 36% and heating increasing by 77%. Above analysis results show that evaluation of window performance based on criteria such as KS F 2278 and KS L 9107 may lead to distortion of performances different from actual products. Thus, it is necessary to suggest new evaluation criteria.

The Effect of the Artificial Ground on Building Thermal Environment (인공지반이 건물 열환경에 미치는 효과에 관한 연구)

  • Hwang, Hyo-Keun;Lim, Jong-Yeon;Ryu, Min-Kyung;Song, Doo-Sam
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.170-175
    • /
    • 2009
  • Apartment housing block has been spreaded according to rapid economic development and urbanization in Korea. A parking lot is located at underground, artificial ground is inevitably created in apartment housing block. Artificial ground creates different thermal environment compared to natural ground, because the composition and coverage of artificial ground are diverse. In this study, the effect of the artificial ground on building thermal environment will be disscussed by simulation. Considering the result of simulation, surface albedo is more important for building energy performance. A purpose of this study is to examine how the characteristic of surface effect to thermal environment, and to develop design method for sustainable outdoor space.

  • PDF

Thermal Performance Evaluation of The Window Film Insulation for Building Energy Savings (건물에너지 절감을 위한 열차단 필름의 성능 평가)

  • Nam, Jung-Woo;Won, Jong-Seo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.75-80
    • /
    • 2008
  • Recently, Energy savings in buildings has received much attention in response to the increased needs for global warming and better comforts of the occupants in apartment housing. This study proposes the method which uses the sun control window film to reduce the cooling load and heating load improving the thermal performance of the building and it improves an energy efficiency. The film which used in actual measurement has a low shading coefficient and a solar energy transmission. so we measured the surface temperature of the triple Low-e glazing system used and inside temperature according to the change of outside temperature and solar energy to study thermal performance evaluation. As a result, it was helpful to use window film insulation to reduce inside temperature in summer and to keep room warm in winter.

  • PDF