• 제목/요약/키워드: Solar Hot Water Heating System

검색결과 116건 처리시간 0.023초

복합형 태양열 가열기의 일일 운전 특성 및 축열 성능에 관한 연구 (A Study on Thermal Storage Performance and Characteristics of Daily Operation of a Hybrid Solar Air-Water Heater)

  • 최휘웅;파쿠르 로커만;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제35권3호
    • /
    • pp.73-79
    • /
    • 2015
  • In this study, a thermal storage performance and characteristics of daily operation were investigated when the air and the liquid were heated simultaneously by a hybrid solar air-water heater that can make hot water as well as heated air. The hybrid solar air-water heater is kind of a flat plate solar collector that can make hot water and heated air by installing air channel beneath absorber plate of traditional flat plate solar collector for hot water. As a result of daily operation, maximum water temperature reached in a thermal storage was shown $44^{\circ}C$ on 73kg/h of air mass flow rate and about $40^{\circ}C$ on 176kg/h of air mass flow rate. Thus, the necessity of heating water in thermal storage by operating only liquid side was confirmed when the temperature of liquid in thermal storage is lower than we need. In case of efficiency investigated on daily operation, the thermal efficiency of the liquid side was decreased with increment of the inlet liquid temperature and decrement of the solar radiation, but efficiency of the air side was increased with increment of inlet liquid temperature difference as the traditional solar air heater. Total thermal efficiency of the collector was shown from 65.85% to 78.23% and it was decreased with increment of the inlet liquid temperature and decrement of solar radiation same as the traditional system.

태양열 온수급탕 시스템의 TRNSYS 열성능 분석 (Performance Analysis of Solar Heating System for High Solar Fraction using TRNSYS)

  • 손진국
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.59-67
    • /
    • 2012
  • In this paper, performances of solar hot water supply systems are parametrically analyzed with the variations of solar collector area, slope of collector and volume of storage. All simulations are conducted by using TRNSYS computer program. Average solar fractions, collector efficiencies and temperatures of storage are investigated monthly as well as annually. For system analysis, the maximum value of monthly average solar fractions has a limitation of 90 percent. As a result, the designed solar thermal system with $6m^2$ collector area, $50^{\circ}$ slope and $0.36m^2$ storage volume could provide almost an annual average solar fraction of 72 percent. By increasing the storage volume to $0.42m^2$, the annual solar fraction of system increases up to 73 percent.

지열-태양열원 복합시스템의 성능평가에 관한 연구 (A Study on the Performance Evaluation of Hybrid Energy System with Geothermal and Solar Heat Sources)

  • 황인주;우남섭;이홍철
    • 설비공학논문집
    • /
    • 제18권3호
    • /
    • pp.279-286
    • /
    • 2006
  • The present study concerns the annual performance evaluation of a hybrid-renewable energy system with geothermal and solar heat sources for hot water, heating and cooling of the residential buildings. The hybrid energy system consists of ground source heat pump of 2 RT for cooling, solar collectors of $4.8m^2$, storage tank of 250 liters and gas fired backup boiler of 11.6 kW. The averaged coefficients of performance of geothermal heat pump system during cooling and heating seasons are measured as 4.1 and 3.5, respectively. Also solar fraction for hot water is measured as 35 percent. Overall, the results shows that the hybrid-renewable energy system satisfactorily operated under all climatic conditions.

태양열 축열조가 없는 변유량 제어 방식의 지역난방용 태양열시스템 실증시험연구 (The Development of the Climatic Design Tool for Energy Efficient Building Design)

  • 백남춘;신우철;이진국;윤응상;윤석만
    • 한국태양에너지학회 논문집
    • /
    • 제28권5호
    • /
    • pp.21-27
    • /
    • 2008
  • In this study, the design of the solar heating system for district heating as well as it's operating characteristics and the performance analysis was carried out. This solar district heating system was composed of two different types of solar collector circuit, flat plate and vacuum tube solar collector, in a system. This system supply constant temperature of hot water without solar buffer tank. For this, the proportional(variable flow rate) control was used. The experimental facility for this study was used the Bundang district solar heating system which was installed in the end of 2006. The operating characteristics and behaviour of each collector circuits are investigated especially for the system design and control. The yearly solar thermal efficiency is 47.5% on the basis of aperture area and 39.8% on the basis of gross area of collector. As a result this solar heating system without solar buffer tank and with proportional controller was testified a very effective and simplified system for district heating. It varied especially depend on the weather condition like as solar radiation and ambient temperature.

태양열 온수기 실증연구를 통한 성능 평가 (Performance Evaluation of Solar Water Heating System Using Proof Test)

  • 김재열;곽이구;양동조;최철준;김홍건
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.597-601
    • /
    • 2006
  • The advantages of solar energy are that it is renewable, infinite supplied and environmentally safe energy source. However, solar energy related products have the problems such as the limitation for installation, problems in maintenance and insufficient reliability which have been the barrier to consumers to satisfy the purchase need for solar heat related products. In this regard, in order to support the solar energy related companies the necessity for various technical information required for the commercialization of new products such as various performance test necessary for the certification of solar energy system, standardization for facilities and products, performance evaluation method and the measurement of performance is suggested. The purpose of this paper is to design the monitoring system for positive tests of system linked household hot water system using solar heat out of various solar energy systems, to establish an analysis and monitoring system for performance maintenance and operation technique, and to configure the centralized detection network by utilizing remote monitoring system. This research also aims at conducting monitoring for operation and performance evaluation in relation to database establishment and analytical evaluation and at describing the method of enhancing the reliability of solar energy system through the development of performance evaluation program.

  • PDF

복합형 태양열 가열기 열매체 동시운전시의 열적 성능에 관한 실험적 연구 (Experimental Study for Thermal Performance of Hybrid Air-Water Heater Using Solar Energy during Heating Medium Working Simultaneously)

  • 최광환;윤정인;손창효;최휘웅;김부안
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.115-121
    • /
    • 2014
  • With increment on interesting about improving renewable energy efficiency, many research have been conducted and the research about hybrid air-water heater using solar energy that can make heating air and hot water has been conducted also. In this experiment, the temperature difference and thermal efficiency were investigated when two heating medium(air and liquid) was working simultaneously. As a result, thermal efficiency showed 44% to 88% when these heating medium was working simultaneously depending on operation condition and it is better than traditional solar collector. Also possibility of application into building equipment also was confirmed based on temperature and thermal efficiency. But necessity of additional studies about proper operation condition according to purpose of use and heat load was confirmed because change of thermal efficiency by air velocity and flux of liquid was shown a huge difference.

겨울철 열펌프 작동온도에 따른 태양열 하이브리드 시스템의 성능특성에 관한 연구 (Study on the Performance Characteristics of the Solar Hybrid System with Heat Pump Operating Temperature during Winter Season)

  • 김원석;조홍현
    • 설비공학논문집
    • /
    • 제22권12호
    • /
    • pp.821-827
    • /
    • 2010
  • Study on the performance characteristics of the solar hybrid system with heat pump operating temperature during winter season has performed by using an experimental test. The system performance and operating characteristics with the heat pump operating temperature, hour and load condition were investigated and analyzed. As a result, the hot water temperature was significantly affected by the heat pump operating temperature at the morning(time 1) and noon(time 2). However, hot water temperature was set by the radiation quality and collecting operation hour at the afternoon(time 3). In addition to the solar fraction was decreased for the high heat pump operating temperature because the heat pump operated with a long operating time and short operating period.

열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향 (An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe)

  • 박이동;정운철
    • 태양에너지
    • /
    • 제16권2호
    • /
    • pp.39-47
    • /
    • 1996
  • 본 연구에서는 실제 열 파이프용 수평 축열조에서 등간격인 heating pad 수와 위치 및 공급열량을 변화시키면서 축열조내의 순수 Plume 유동특성을 파악하였다. 동일한 heating pad수를 가지고 집중 배치 형태와 분산 배치 형태를 취하였을 때 집중 배치 형태로 취하는 것이 $5{\sim}6%$ 정도의 더 높은 효율을 얻었다. 따라서 열 파이프용 수평 축열조에서 heating pad를 장착할 때 동일한 heating pad의 수에서는 집중(concentration)배치형태로 설계하는 것이 효과적임을 알 수 있다.

  • PDF

Liquid Based Solar Thermal Storage를 위한 열교환성능(熱交換性能)에 관한 연구(硏究) (A Study on the Heat Exchange Performance for the Liquid Based Solar Thermal Storage)

  • 김병철;정현채
    • 태양에너지
    • /
    • 제5권2호
    • /
    • pp.35-45
    • /
    • 1985
  • A solar hot water storage tank was designed and constructed to examine the heat exchange performances on load side for the solar thermal storage in a single loop solar water heating system. In the tank helically coiled tube was immersed. The hot water was circulated from either top or bottom. The circulation flow rate was varied from 500 ml/min to 20,000 ml/min. The effect of flow rate was observed. The thermal performances according to the flow rate and flow direction were examined. The temperature distributions in the tank and inside of the tubes were plotted along the process of cooling.

  • PDF

건물의 $CO_2$ 배출 저감 건축기술요소 제안에 관한 연구(공동주택을 중심으로) (A Study on the Proposal of Building Technologies for Reducing $CO_2$ Emission of Buildings(Focused on the Multi-Family Residential Buildings))

  • 이종식;강혜진;박진철;이언구
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.91-96
    • /
    • 2009
  • First, the base model of multi-family residential buildings are selected, and then the $CO_2$ reduction building technologies that are applicable for multi-family residential buildings are induced by analyzing the examples and then an optimal plan for when the $CO_2$ reduction building technologies can be integrated and applied to the base model was formulated. In the results of converting the energy consumption and reduction amount from the building technologies into $CO_2$ emissions to analyze the distribution ratio compared to the entire $CO_2$ emissions; the heat recovery ventilator is 0.5%, the photovoltaic system is $1.9%{\sim}5.9%$, the solar hot water heating system is $6.3%{\sim}13.1%$ and the ge thermal heat-pump system is 39.0% when both heating and hot water heating are applied. An optimally integrated application method for the building technologies is in charge of heating and hot water heating through the geothermal source heat pump system and in charge of the electricity load through the photovoltaic system(45.2%).

  • PDF