• Title/Summary/Keyword: Solar Heat storage

Search Result 289, Processing Time 0.028 seconds

A Simulation for the Stratified Thermal Storage System in Residential Solar Energy Application (주거용 태양열 성층축열시스템의 시뮬레이션)

  • Pak, Ee-Tong;Yoo, Ho-Seon
    • Solar Energy
    • /
    • v.11 no.3
    • /
    • pp.44-52
    • /
    • 1991
  • The benefits of thermal stratification in sensible heat storage systems has been considered and studying by several investigators. In this paper, the basic data which is hard to obtain normally through the experiment were obtainable through the computer simulation. The major objectives of the study were to assess the benefits of stratified storage in residential solar water heating application and to suggest the optimum design parameters. From the computer simulation, following results were obtained. 1. The solar load fraction increases with increasing the number of tank segments. In these simulation, the magnitude of the improvement was about 10%. 2. The solar load fraction increases when the ratio of diameter to height of the tank(H/D) increases to 3, but H/D exceed 3 then, the solar load fraction decreases. In these simulation, the magnitude of the improvement was about 3%. 3. Increasing the collector flow rate slightly improved the performance of the mixed storage system(Node=1). But, for the stratified storage system(Node=N), the solar load fraction increases with decreasing flow rate until the point is reached at which the collector outlet temperature reaches the boiloff limit of $100^{\circ}C$ over some portion of the simulation period.

  • PDF

Active Solar Heating System Design and Analysis for the Zero Energy Solar House (제로에너지 솔라하우스의 난방/급탕용 태양열 시스템 설계 및 분석)

  • Baek, N.C.;Yoo, C.K.;Yoon, E.S.;Yoo, J.Y.;Yoon, J.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.1-9
    • /
    • 2002
  • This study is on the design and evaluation of Zero Energy Solar House(ZeSH) including active solar heating system. Various innovative technologies such as super insulation, passive solar systems, super window, ventilation heat recovery system...etc were analyzed by individual and combination for the success of ZeSH. The ESP-r simulation program was used for this. Simulation results shows that almost 77% of heating load can be reduced with the following configuration of 200mm super insulation, super windows, passive solar system and 0.3 ventilation rate per hour. Active solar heating system (ASHS) was designed for the rest of the heating load including hot water heating load. The solar assisted heat pump is used for the auxiliary heating device in order to use air conditioner but not included in this study. The yearly solar fraction is 87% with a solar collector area of $28m^2$. The parametric studies as the influence of storage volume and collector area on the solar fraction was analyzed.

A Study on the Thermal Prediction Model cf the Heat Storage Tank for the Optimal Use of Renewable Energy (신재생 에너지 최적 활용을 위한 축열조 온도 예측 모델 연구)

  • HanByeol Oh;KyeongMin Jang;JeeYoung Oh;MyeongBae Lee;JangWoo Park;YongYun Cho;ChangSun Shin
    • Smart Media Journal
    • /
    • v.12 no.10
    • /
    • pp.63-70
    • /
    • 2023
  • Recently, energy consumption for heating costs, which is 35% of smart farm energy costs, has increased, requiring energy consumption efficiency, and the importance of new and renewable energy is increasing due to concerns about the realization of electricity bills. Renewable energy belongs to hydropower, wind, and solar power, of which solar energy is a power generation technology that converts it into electrical energy, and this technology has less impact on the environment and is simple to maintain. In this study, based on the greenhouse heat storage tank and heat pump data, the factors that affect the heat storage tank are selected and a heat storage tank supply temperature prediction model is developed. It is predicted using Long Short-Term Memory (LSTM), which is effective for time series data analysis and prediction, and XGBoost model, which is superior to other ensemble learning techniques. By predicting the temperature of the heat pump heat storage tank, energy consumption may be optimized and system operation may be optimized. In addition, we intend to link it to the smart farm energy integrated operation system, such as reducing heating and cooling costs and improving the energy independence of farmers due to the use of solar power. By managing the supply of waste heat energy through the platform and deriving the maximum heating load and energy values required for crop growth by season and time, an optimal energy management plan is derived based on this.

Review on the Use of Solar Energy for Grain Drying (태양열을 이용한 곡물건조에 관한 연구)

  • 금동혁;고학균;최재갑
    • Journal of Biosystems Engineering
    • /
    • v.3 no.1
    • /
    • pp.64-76
    • /
    • 1978
  • A dimensional supply of petroleum fuels and increased competition for petroleum products has made the conservation of energy in grain drying an important cost and management factor. Research on solar grain drying is directed toward utilization of a renewable energy source as an alternative to petroleum fuels for drying. There are many technical and economic problems in accepting and adopting solor energy as a new energy source for grain drying. The purpose of this study are to assess the state of the art of solar grain drying and to find out the problems by reviewing literatures available. The results obtained may be summarized as follows; 1.It may be considered that the weather conditions in October of Korea was satisfactory for the forced natural air and solar heated air drying. 2. Solar energy is considered more applicable to low-temperature, In-storage drying systems than to high-temperature, high-speed drying systems. In-storage drying systems require low levels of heat input. The costs of collector systems to provide low temperature are considerably cheaper than for high-temperature systems. 3. Tubular type collector made of polyvinyle film seems to be the most practical at this stage of development and black-painted bare-plate collectors mounted on the outside of a typical, round, low-temperature drying bin can supply an appreciable amount of the energy efficiently needed for low-temperature grain drying at a lower cost. 4. All of the grains in solar drying tests was successfully dried up to safe storaged moisture levels without significant spoilage. Drying rates with solar system were faster than natural air drying systems, and usually a little slower than similar low-temperature electric drying systems. 5. Final grain moisture levels were lower in solar tests than in natural air tests, and generally higher than in tests with continuous heated air. 6. Savings of energy by use of solar collectors ranged from 23% to 55%, compared to the natural and electric ileated air drying systems. However, total drying cost effectiteness tvas not significant. Therefore, it is desirable that solar grain dry-ing sIFstems tvhich could be suitable for multiple heating purposes on farms shouldbe developed. 7. Supplemental heat with solar radiation did little to reduce air flow requirementsbut refuced drying time and increased the p\ulcornerobability of successful drying duringdrying poriod.

  • PDF

A Study on Heat Storage System Using Calcined Dolomite - Numerical Analysis of Heat Transfer in Calcined Dolomite Hydration Pocked Bed - (소성Dolomite 수화물계의 축열시스템에 관한 연구 - 소성Dolomite 수화반응층의 전열해석 -)

  • Park, Young-Hae;Kim, Jong-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.1
    • /
    • pp.9-21
    • /
    • 2002
  • To develope chemical heat pump using available energy sources, solar heat and other kinds of waste thermal energy, we have studied the heat transfer rate in cylindrical bed reactor packed with calcined Dolomite. Two dimensional (radial and circumferential) Partial differential equations, concerning heat and mass transfer in packed bed of calcined Dolomite, are solved numerically to describe the characteristics of the reaction of calcined Dolomite and heat transfer. The results obtained by numerical analysis about two dimensional profiles of temperature and conversion of reactant in the packed bed reactor and the amount of exothermic heat released from the reactor are follows. It was found that all of calcined Dolomite packed bed kept the reaction temperature of about 750K throughout the entire part of the bed, immediately after the steam was introduced exothermic reaction of hydration was proceeded from the packed bed inpu to output and from wall side to center. The rate of thermochemical reaction depends on the temperature and concentration and it is also governed by the boundary conditions and heat transfer rate in the particle packed bed.

A Study on Heat-transfer Characteristics the Shelter by Solar-heat Radiant (쉘터의 태양열 복사에 의한 열전달 특성에 관한 연구)

  • Shim, Dong-Hyouk;Noh, Kyung-Ho;Park, Jin-Yong;Lim, Young-Taek
    • Journal of the Korea Society for Simulation
    • /
    • v.27 no.2
    • /
    • pp.25-33
    • /
    • 2018
  • When developing military equipment, it should be designed considering the temperature condition so that the operator can operate in a stable environment. The shelter for storing various military equipments is operated in various environments. The storage temperature and operating requirements of the test equipment and repair accessories shall be $-32^{\circ}C$ to $50^{\circ}C$ and the inside of the shelter shall be designed to meet the storage temperature and operating requirements. In this study, thermal analysis of a 2.5 ton military shelter operating under high temperature and solar heat conditions is performed considering MIL-STD-810G. The thermal analysis was applied by using the concept of heat resistance and heat circuit, and the solar thermal test was performed on the actually manufactured military shelter in order to verify the analysis results.

Daily Variation of Heat Budget Balance in the Gangjeong-Goryung Reservoir for Summertime - Concerning around the Rate of Heat Storage - (낙동강 강정고령보의 여름철 열수지 일변화 - 열 저장량 변동을 중심으로 -)

  • Kim, Seong-Rak;Cho, Chang-Bum;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.24 no.6
    • /
    • pp.721-729
    • /
    • 2015
  • Surface heat balance of the Gangjeong-Goryung Reservoir is analyzed for 12-17 August 2013. Each flux elements at the water surface is derived from the special field observations with application of an aerodynamical bulk method for the turbulent heat fluxes and empirical formulae for the radiation heat fluxes. The rate of heat storage in the reservoir is estimated by using estimated by surface heating rate and the vertical water temperature data. The flux divergence of heat transport is estimated as a residual. The features of the surface heat balance are almost decided by the latent heat flux and the solar radiation flux. On average for 12-17 August 2014 in the Gangjeong- Goryung Reservoir, if one defines the insolation at the water surface as 100 %, 94 % is absorbed in the reservoir; thereafter the reservoir loses about 30~50% by sensible heat, latent heat and net long-wave radiation. The residue of 50~80 % raises the water temperature in the reservoir or transported away by the river flow during the daytime.

Heat Transfer Chracteristics in a Fluidized bed Heat Storage System Using Encapsulated PCM (캡슐화된 PCM을 이용한 유동층 축열조에서 열전달 특성 연구)

  • Yoon, Y.H.;Han, G.Y.;Kang, Y.H.;Kwak, H.Y.;Lee, T.K.;Jeon, M.S.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.89-94
    • /
    • 1998
  • The heat transfer characteristics of a fluidized bed latent heat storage system using encapsulated PCM was investigated. The cylindrical test section has the dimension of 50 mm I.D. and 40 cm in height. The phase change material(PCM) was the sodium acetate and was encapsulated by the multiple layers of PMMA and paraffin wax. The size of encapsulated PCM was $2{\sim}3mm$ and melting point was $58^{\circ}C$. The instantaneous heat storage and heat release rates were determined and the instantaneous heat transfer coefficient based on the fluidized bed volume was also determined. The effect of inlet temperature and velocity of heat transfer fluid on the heat transfer coefficient was also investigated.

  • PDF

Solar Absorption Cooling System applicable to Educational Facilities (교육시설에 적용 가능한 태양열 흡수식 냉각 시스템)

  • Youn, Sung-Min;Paek, In-Su;Han, Young-Tae;Nam, Hyo-Gab
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.3
    • /
    • pp.35-41
    • /
    • 2011
  • Performance of a small-capacity solar absorption cooling system was investigated experimentally. Ten sets of evacuative-tube solar-heat collectors and a 5 kW single-stage absorption cooler were combined to produce a hybrid cooling system. The performance of the cooling system was measured using a tim-coil unit installed in a small plastic storage. It was found from the test on a sunny day of May that when the temperature of the hot water supplied from the solar collectors to the generator of the absorption cooler reached $60^{\circ}C$, the absorption cooler started cooling and the cold water temperature measured from the fan-coil unit reached $18^{\circ}C$. The COP, which is defined as the ratio of the cooling power to the total electrical power input was higher than 1.0.

  • PDF

Optimum Collector Area and Economic Evaluation for the Greenhouse Heating (태양열 온실 난방에 대한 최척 집열 면적과 경제성 평가)

  • Pak, Ee-Tong;Kim, Kyu-In
    • Solar Energy
    • /
    • v.2 no.1
    • /
    • pp.49-58
    • /
    • 1982
  • Aim of this study was to obtain the heating performance and the economic evaluation on solar heating system for greenhouse which area of floor was $90m^2$. For heating performance effective solar energy for the greenhouse was compared with overall heating loads including coefficient of heat transfer and conduction. And the economic evaluation solar heating system was evaluated by comparison its initial investiment costing with oil saving cost. Initial investiment costing included collector cost, storage cost, piping cost, control system cost and miscellaneous costs which included pumps, motors etc. The contents of this study included the survey of climate conditions for solar heating, long-term collector performance and optimum collector area of solar heating system in existing greenhouse. The results are follows: 1. Average horizontal radiation during winter was $2,434Kcal/m^2$ day which was the highest value in this country, so the climate conditions of Suwon was suitable for solar heating. 2. Resulting calculation of the optimum collector area was $30m^2$ and the solar energy accounted for 30% of the overall heating load. 3. The capacity of storage tank required 60 liter per unit area ($m^2$) of solar collector.

  • PDF