• 제목/요약/키워드: Solar Heat pump

검색결과 186건 처리시간 0.035초

건물일체형 지열히트펌프시스템의 난방 성능 분석 (Heating Performance Analysis of Building Integrated Geothermal System)

  • 김상진;이진욱;김태연;이승복
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.206-210
    • /
    • 2012
  • Ground source heat pump is a central heating and cooling system that pumps heat to or from the ground. Building Integrated Geothermal system used in this experiment is one of the Ground Source Heat Pump Systems which utilize energy pile. The purpose of this study is to evaluate heating performance of the system. The building is a low-energy experiment apartment in Yonsei University Songdo Campus and the subject is one of the energy reduced houses in this apartment. In the experiment, indoor temperature, outdoor temperature and the inlet and outlet temperature of ground heat exchanger and subject model, were measured. Then the heat pump's Coefficient of performance(COP) of the heat pump was calculated. As a result, the COP of heat pump is 4-5. Although the depth of the ground heat exchanger in this experiment is shallower than usual heat exchanger, the result of heating performance of this system was good as well.

  • PDF

건축물 냉.난방 시스템에 따른 에너지 소비 특성 -서울 소재 A 대학교 건축물을 중심으로- (The Energy Consumption Characteristics of Building Accordance with Air-Conditioning and Heating System)

  • 박강현;차정훈;김수민
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.333-337
    • /
    • 2011
  • Central control air-conditioning systems are being replaced with individually controlled air-conditioning system in the university. The amount of growth of electricity consumption is due to the increasing demand of electric heat pump. In winter and summer, the energy consumption showed a tendency to increase. On the other hand, showed less energy in spring and autumn. Increase the amount of electricity than the degree of decline in gas consumption was higher. Can be considered as transitional phenomena. Because electric heat pump, gas driven heat pump and the absorption chiller-heater are used at the same time in some of the buildings.

  • PDF

소규모 주택에 대한 수평형 지열 히트펌프 형태 결정에 관한 연구 (A Study on the description of Horizontal Geothermal Heat pump Type on Small Residential House)

  • 윤장렬;조성우;최정민
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.328-332
    • /
    • 2011
  • The conclusion is derived from the arranged results and using a simulation by determining the shape of an optimum heat pump which is appropriate for small scale houses. It is concluded as 3 meters long for the laying depth of underground piping of the horizontal type geothermal heat pump system in regard to the 5 RT capacity standard that is suitable for a small scale house. The shape of the horizontal type geothermal heat pump system for a small scale house is theThree pipe shape whose trench length is short and pipe length laid in a trench is short. It is 9 for the number of laying pipes that is most appropriate to system.

  • PDF

소성Dolomite 수화물계의 축열시스템에 관한 연구 - 소성Dolomite 탈수반응층의 전열해석 - (A Study on Heat Storage System Using Calcined Dolomite - Numerical Analysis of Heat Transfer in Calcined Dolomite Dehydration Packed Bed -)

  • 박영해;김종식
    • 한국태양에너지학회 논문집
    • /
    • 제23권1호
    • /
    • pp.29-38
    • /
    • 2003
  • To develope chemical heat pump using available energy sources, solar heat and other kinds of waste thermal energy, we have studied the material and heat transfer rate in the cylindrical bed reactor packed with Calcined Dolomite. Our results from the studies are as follows ; 1 The time needed to complete dehydration reaction at the wall side of the cylindrical reactor(r/rL=0.5) was shorter than that of the center(r/rL=0.0) as much as 12%. 2. Two dimensional (radial and circumferential) partial differential equations, concerning heat and mass transfer rate in the packed bed of calcined Dolomite, are solved numerically to describe the characteristics of the reaction in the cylindrical reactor. The solution reads rate of reaction in the packed bed reactor depends on the temperature and concentration of reactants. These results read the supplied heat transfers from the wall side of the cylinder to the center, dehydration reaction begins at the inner side of the wall of the cylindrical reactor and the dehydration reaction proceeds from the wall side to center of cylinder.

제로에너지 솔라하우스(KIER ZeSH)의 에너지 자립도 및 경제성 분석 (The Study on the Energy self-sufficiency and Economic Analysis of KIER Zero Energy Solar House)

  • 정선영;백남춘;유창균;윤응상;윤종호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.64.1-64.1
    • /
    • 2010
  • In this study, the energy and economic analysis of KIER Zero Energy Solar House (KIER ZeSH) was carried out. KIER ZeSH was designed and constructed in the end of 2009 for the purpose of more than 70% energy self-sufficiency in total load as well as less than 20% of additional construction cost. The several building energy conservation technologies like as super insulation, high performance window, wast heat recovery system, etc and renewable energy system. The renewable heating and cooling system is a kind of solar thermal system combined with geo-source heat pump as a back-up device. The capacity of 3.15kW solar BIPV system was also installed on the roof. The measurement by monitering system of ZeSH was conducted for one year from November 2009 to October 2010. The energy self-sufficiency and economic analysis were conducted based on the this monitering result. As a result, the energy self sufficiency is about 83% which is higher than that of the target and the payback period is 11 years.

  • PDF

PERFORMANCE EVALUATION OF BUBBLE PUMP USED IN A PASSIVE SOLAR WATER HEATER SYSTEM

  • ;박기태;정한식;정효민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2309-2314
    • /
    • 2007
  • The application analysis of bubble pump on the domestic solar water heater system is presented. The system investigated in this study is a passive device, self pumping and self regulating. It was test to use the bubble pump on solar water heater system. The test experiment has been taken on the existed vacuum tube about the efficiency, working fluid temperature and pressure and circulated power. In order to check the working temperature and working pressure effectively, the bubble pump was test separated from the solar water heater. The equipment consists of the bubble pump, heater and heat exchanger. The main structure of bubble pump was design depend on the character of two phase flow. The complete system was instrumented to measure pressures, temperatures and flow-rates at various locations. The theory analysis of design bubble pump has been given and the experiment design has been included in the paper.

  • PDF

하수열을 이용한 냉난방시스템에 관한 연구 (Heating and Cooling System using the Sewage Source Absorption Refrigeration and Heat Pump Cycle)

  • 이용화;신현준;윤희철;박현건
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.19-26
    • /
    • 2007
  • This paper concerns the study of absorption refrigeration and heat pump cycle to use sewage. Simulation analysis on the double-effect absorption refrigeration cycle with parallel and two-stage heat pump cycle has been performed. The working fluid is Lithium Bromide and water solution. The absorption refrigeration cycle use sewage as a cooling water for the absorber and condenser, and absorption refrigeration cycle does that as a chilled water for the evaporator of the first stage cycle. And the two-stage cycle consists of coupling double-effect with parallel and single effect cycle so that the first stage absorber and condenser produces heating water to evaporate refrigerant in the evaporator of the second stage. The effects of operating variables such as a absorber temperature on the coefficient of performance have been studied for absorption refrigeration and heat pump cycle.

흡수액으로 에틸렌글리콜이 혼합되고 태양열을 이용한 이중효용 흡수식 시스템의 냉방 특성해석 (Analysis of Thermodynamic Design Data for Cooling of Double -Effect Absorption System of Solar Energy using LiBr - water and Ethylene Glycol Mixture)

  • 원승호;박상일
    • 한국태양에너지학회 논문집
    • /
    • 제23권4호
    • /
    • pp.45-54
    • /
    • 2003
  • For cooling of double effect absorption heat pump system of solar heating source, analysis of thermodynamic design data has been done to find the property of Libr-water + ethylene Glycol mixture for working fluid by computer simulation. Derived thermodynamic design data, enthalpy based coefficient of performance and flow ratio for possible combinations of operating temperature for water - LiBr and Ethylene Glycol mixture ($H_2O$ : CHO ratio 10:1 by mole) by computer simulation are done. The obtained results, COP and mass flow ratio of the water - lithium bromide - ethylene glycol system, are compared with data for the water-Libr pair solution.

온실 내외부 공기열의 선택적 축열에 의한 히트펌프 난방성능 개선 (Improvement of Heat Pump Heating Performance by Selective Heat Storage Using Air Heat of Inside and Outside Greenhouse)

  • 권진경;김승희;전종길;강연구;장갑열
    • 생물환경조절학회지
    • /
    • 제26권4호
    • /
    • pp.353-360
    • /
    • 2017
  • 본 연구에서는 장미 재배온실을 대상으로 온실 내부의 태양잉여열과 외부의 공기열을 선택적 열원으로 이용하여 온실난방용 온수를 생산할 수 있는 공기 대 물 히트펌프의 설계와 성능시험을 수행하였다. 태양잉여열 이용 축열운전과 외기열 이용 축열운전은 작물의 생육적온을 고려한 온실내부의 설정온도에 따라 자동전환 되도록 설계하였다. 제어반에 12개의 기준온도를 설정함으로써 축열운전 전환, 난방, 환기를 자동제어하며, 태양잉여열-외기열 선택적 축열운전에서 축열조의 온도는 축열능력과 난방부하에 대응하여 $35{\sim}52^{\circ}C$로 3단계 변온제어 하였다. 태양잉여열-외기열 선택적 축열에서 태양잉여열 이용 축열은 전체 시간의 23.1%, 외기열 이용 축열은 30.7%, 히트펌프 휴지시간은 46.2%를 차지하였으며, 난방성능계수는 태양잉여열 이용 축열 시 3.83, 외기열 이용 축열시 2.77, 전체 3.24로 평가되었다. 비교시험을 위해 축열조 온도를 $50{\sim}52^{\circ}C$로 항온제어 하는 조건에서 외기열 단독 이용 축열 시험을 수행하였으며 이때의 난방성능계수는 2.33으로 분석되었다. 결과적으로 공기 대 물 히트 펌프의 열원으로 온실내부 태양잉여열과 외부 공기열을 병용하고, 축열조 온도를 변온제어 한 결과 일반적인 외기열 이용 축열운전과 축열조 항온제어에 비해 난방성능 계수가 39% 향상됨을 확인하였다.