• Title/Summary/Keyword: Solar City

Search Result 173, Processing Time 0.035 seconds

Analysis of Climate, Weather, Solar Radiation and Solar Energy in Major Cities of Tajikistan (타지키스탄 주요 도시의 기후, 날씨, 일사량 및 태양에너지 분석)

  • Taeyoo Na;Jeongdu Noh;Hyeontae Kim;Seong-Seung Kang
    • The Journal of Engineering Geology
    • /
    • v.33 no.3
    • /
    • pp.389-401
    • /
    • 2023
  • Climate, weather, insolation (solar radiation), and solar energy in major cities of Tajikistan were investigated prior to construction of infrastructure for the Dushanbe Solar Station. In Dushanbe city there was a 70% probability of sunny days from May 16 to October 23, a period of 5.2 months. August had the most sunny days of in the year, with 99% probability of a sunny, the cloudiest month was February with a 41% chance of being sunny. In major cities of the Sughd and Gorno-Badakhshan states, the average number of cloudy days per month was ~3.3, with Dzhauz having 53 day and Fedchnko Glacier 79 days. For the 18 major cities of Tajikistan, the average annual total solar radiation was 2,429 W/m2, and the average monthly solar radiation was 202 W/m2. The city with the lowest annual total and monthly average solar radiation was Shartuz in Sughd state, with values ~2.7% less than the national average. The cities with the highest annual total and monthly average solar radiation were Khorog and Jirgatol in Gorno-Badakhshan state, with values ~10% above the national average. The daily average incident shortwave solar energy in the cities Dushanbe, Karakul, and Jirgatol was ~7.8 kWh per 2.4 m2 during summer (May-August), and 2.7 kWh during winter (November-February), or ~35% that of summer.

A Simulation Study on the Annual Heating Performance of the Seawater-Source Screw Heat Pump (해수열원 스크류 히트펌프의 연간 난방운전 성능 모사)

  • Baik, Young-Jin;Kim, Min-Sung;Chang, Ki-Chang;Lee, Young-Soo;Kim, Hyeon-Ju
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.88-95
    • /
    • 2012
  • In this study, in order to utilize the seawater as a heat source at Gangneung city near the East Sea in Korea, an annual heating performance of a screw heat pump was simulated. For a simulation, the maximum heating capacity of heat pump was assumed at 3.5 MW. An ambient temperature at Gangneung city was calculated from the TMY2 weather data, while the seawater temperature was calculated from the regression equation based on the measurement by the National Fisheries Research and Development Institute of Korea. The heating load was assumed linearly dependent on the ambient temperature, while the maximum heating load was assumed to appear when the ambient temperature is below $-2.4^{\circ}C$, which is the temperature of TAC 2.5% for heating at Gangneung city. A heat pump performance at full-load was calculated from the regression equation, which involves refrigerant's evaporating and condensing temperatures, based on a commercial screw compressor performance map. A heating supply temperature which determines refrigerant's condensing temperature was assumed linearly dependent on the heating load. A performance degradation due to the part-load operation of heat pump was also considered. Simulation results show that an annual heating coefficient of performance ($COP_H$) of a seawater-source screw heat pump is approximately 2.8 and that it is necessary to improve part-load performance to increase an annual performance of the heat pump.

The Effect of Urban Trees on Residential Solar Energy Potential (도심 수목이 분산형 주거 태양광에너지 잠재량에 미치는 영향)

  • Ko, Yekang
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.1
    • /
    • pp.41-49
    • /
    • 2014
  • This study spatially assesses the impact of trees on residential rooftop solar energy potential using urban three-dimensional models derived from Light Detection and Ranging(LiDAR) data in San Francisco, California. In recent years on-site solar energy generation in cities has become an essential agenda in municipal climate action plans. However, it can be limited by neighboring environments such as shade from topography, buildings and trees. Of all these effects, the impact of trees on rooftop photovoltaics(PVs) requires careful attention because improper situation of solar panels without considering trees can result in inefficient solar energy generation, tree removal, and/or increasing building energy demand and urban heat island effect. Using ArcMap 9.3.1, we calculated the incoming annual solar radiation on individual rooftops in San Francisco and the reduced insolation affected by trees. Furthermore, we performed a multiple regression analysis to see what attributes of trees in a neighborhood(tree density, tree heights, and the variance of tree heights) affect rooftop insolation. The result shows that annual total residential rooftops insolation in San Francisco is 18,326,671 MWh and annual total light-loss reduction caused by trees is 326,406 MWh, which is about 1.78%. The annual insolation shows a wide range of values from $34.4kWh/m^2/year$ to $1,348.4kWh/m^2/year$. The result spatially maps the locations that show the various levels of impact from trees. The result from multiple regression shows that tree density, average tree heights and the variation of tree heights in a neighborhood have statistically significant effects on the rooftop solar potential. The results can be linked to municipal energy planning in order to manage potential conflicts as cities with low to medium population density begin implementing on-site solar energy generation. Rooftop solar energy generation makes the best contribution towards achieving sustainability when PVs are optimally located while pursuing the preservation of urban trees.

A Study on the Sustainable Development of Pusan Metropolitan City by the EMERGY Evaluation (EMERGY 평가에 의한 부산광역시의 지속적인 발전가능성 평가)

  • Son, Ji-Ho;Lee, Suk-Mo
    • Journal of Environmental Science International
    • /
    • v.9 no.3
    • /
    • pp.185-191
    • /
    • 2000
  • Sustainable development has been the key concept, both in economic policies and in environmental management since 1970s. In the view of systems ecology, sustainable resource use strategies are considered to be essential in achieving sustainable development. During the last three decades, the discipline of systems ecology has applied ecological energetic analysis to the evaluation of the contribution of natural environments to economic systems. ENERGY analysis of main energy flows driving the economy of humans and life support systems of a city was made including environmental energies, fuel, and inputs, all expressed as solar emjoules. Total EMERGY use of Pusan was 3.89 E22 sej/yr, about 90 percent of it was purchased sources from outside during eleven years from 1985 to 1995. EMERGY flows from the environment were less than 10 percent. EMERGY yield ratio and environmental loading ratio were 1.10 and 10.45, respectively. EMERGY sustainability index is there(ore less than one, which is indicative of highly developed consumer oriented economies. Development of a city has been achieved in the short run by the economic growth, but it can be sustained in the long run by the use of renewable resource systems.

  • PDF

The Development of High School Instructional Program for Increasing Creative Thinking Abilities: Focused on Building a Scale Model of the Solar System (창의적 사고 계발을 위한 고등학교 학습 프로그램 개발: 태양계 축소 모형을 중심으로)

  • Kim, Eun-Ju;Lee, Hyo-Nyong;Yoon, Ill-Hee;Kang, Chun-Duk
    • Journal of the Korean earth science society
    • /
    • v.29 no.3
    • /
    • pp.290-304
    • /
    • 2008
  • The purpose of this study was to develop instructional programs for 10th graders to facilitate their creative thinking abilities and understanding concerning the scale of the Solar System. The programs were based on four major themes and composed of eight lessons which dealt with the relative scale of the Solar System. The programs were applied to 155 students at G high school in Gumi City. The results showed that the programs were helpful to students in that they facilitated easier understanding of the relative sizes of planets within the solar system as well as creative thinking abilities including divergent thinking and convergent thinking.

Effect Analysis on Self-supporting Energy of Newtown Sewage Treatment Facility for Low-carbon Green City (저탄소 녹색도시 조성을 위한 신도시 하수처리시설의 에너지 자립 효과 분석)

  • Ahn, Soo-Jeung;Hyun, Kyoung-Hak;Kim, Jong-Yeob;Choung, Youn-Kyoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.6
    • /
    • pp.683-690
    • /
    • 2010
  • Renewable and unutilized energy (biogas power generation, wind power, solar, small hydro-power, sewage heat source, etc.) seems to be suitable to install for the sewage treatment facilities. There are 357 sewage treatment plants in 2007. 17 plants among these have been operating for self-supporting energy by using solar power, small hydro-power and biogas in 2008. Newly built sewage treatment plant of 96,000 $m^3$/day for a newtown is expected to get up to energy consumption of 10 GWh/yr. If solar energy, small hydro-power and biogas-equipments were applied to the new treatment plant, self-supporting energy of the new sewage treatment plant will get up to 56.1%. As a results, about 2,379ton $CO_2$/yr $CO_2$ emission reduction can be expected by using renewable energy. These efforts for self-supporting energy will lead sewage treatment plant to new energy recycle center.

A Study on the Atmospheric Clearness Estimation of Major Cities in Korea Peninsula Using Empirical Forecasting Models (경험적 예측모형을 통한 한반도 주요 도시의 대기청명도 평가)

  • Jo, Dok-Ki;Kang, Young-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.4
    • /
    • pp.25-34
    • /
    • 2008
  • Since the atmospheric clearness index is main factor for evaluating atmosphere environment, it is necessary to estimate its characteristics all over the major cities in Korea Peninsula. We have begun collecting clearness index data since 1982 at 16 different cities in South Korea and estimated using empirical forecasting models at 21 different stations over the North Korea from 1982 to 2006. This considerable effort has been made for constructing a standard value from measured data at each city. The new clearness data for global-dimming analysis will be extensively used by evaluating atmospheric environment as well as by solar PV application system designer or users. From the results, we can conclude that 1) Yearly mean 63.5 % of the atmospheric clearness index was evaluated for clear day all over the 37 cities in Korea Peninsula, 2) Clear day's atmospheric clearness index of spring and summer were 64.6 % and 64.8 %, and for fall and winter their values were 63.3 % and 61.3% respectively in Korea Peninsula.

Analysis of Global Dimming Appearances Using the Solar Radiation Measurement in Korean Major Cities (태양복사 측정에 의한 주요 도시의 Global Dimming 현상분석)

  • Jo, Dok-Ki;Kang, Young-Heack
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.146-149
    • /
    • 2008
  • Since the atmospheric clearness index is main factor for evaluating global-dimming of atmosphere environment, it is necessary to estimate its characteristics all over the major cities in Korea. We have begun collecting clearness index data since 1982 at 16 different cities and considerable effort has been made for constructing a standard value from measured data at each city. The new clearness data for global-dimming analysis will be extensively used by evaluating atmospheric environment as well as by solar PV application system designer or users. From the results, we can conclude that 1) Yearly mean 61.9 % of the atmospheric clearness index was evaluated for clear day all over 2) A significant difference of atmospheric clearness index is observed between 1982-1989 and1990-1997, 1998-2005 through 16 different cities in Korea.

  • PDF

An Analysis on Building Shading Plan for a City Hall considering Energy Saving

  • Kim, Jin Lee;No, Sang Tae
    • KIEAE Journal
    • /
    • v.16 no.2
    • /
    • pp.5-10
    • /
    • 2016
  • Purpose: Recently, many public office buildings which were built by curtain wall increased rapidly, but the results of the investigation of the government, these buildings have been found that the heating and cooling thermal load is high, and showed low energy efficiency. Method: To evaluate the effects by applying outdoor louver and indoor blind, which can control solar radiation in order to reduce the heating and cooling load of public office building which was built by glass curtain wall. The heating and cooling load was calculated via Energyplus, building and outdoor louver, indoor blind were modeled by Google sketchup connected to Energyplus. Result: The results of this study were as follows; the case of applying various outdoor louver, the heating and cooling load all decreased as compared to the case without applying outdoor louver, the case of applying indoor blind, the heating and cooling load decreased as compared to the case without applying indoor blind, but indoor blind showed low energy performance comparing outdoor louver.

Change of Thermal Environment with Urban Expansion (도시 확장에 따른 온열환경의 변화)

  • Kim, Sang-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.95-101
    • /
    • 2007
  • The surface changes due to urban expansion and the increase of artificial heat releases have brought significant climate changes such as heat island phenomenon in urban area. Furthermore, these changes also have brought serious problems such as air temperature increase, wind changes, and air pollution in urban area. Comprehensive analytical technologies considering various effects are required to analyse complicated mechanism of climate changes, and review the efficient measures. In this research, the effect of the urban expansion in Tokyo and Bangkok area on urban environment will be discussed. By using CFD, urban development and the mechanism of global warming and wind change are studied in those two cities. As a result of numerical research, the surface changes of city could bring the environmental changes in urban area.