• 제목/요약/키워드: Solar City

검색결과 175건 처리시간 0.029초

태양에너지 측정에 의한 한반도 주요 도시의 대기청명도 분석 (Atmospheric Clearness Index Analysis of Major Cities in Korea Peninsula Using Solar Radiation Measurement)

  • 조덕기;강용혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.174-177
    • /
    • 2008
  • The amount of incident solar rays on inclined surfaces with various directions has Since the atmospheric clearness index is main factor for evaluating atmosphere environment, it is necessary to estimate its characteristics all over the major cities in Korea Peninsula. We have begun collecting clearness index data since 1982 at 16 different cities in South Korea and estimated using empirical forecasting models at 12 different stations over the North Korea from 1982 to 2006. This considerable effort has been made for constructing a standard value from measured data at each city. The new clearness data for global-dimming analysis will be extensively used by evaluating atmospheric environment as well as by solar application system designer or users.

  • PDF

태양광에너지 측정을 통한 우리나라 주요 도시의 Global Dimming 현상 분석에 관한 연구 (대기의 청명도 분석을 중심으로) (A Study on the Analysis of Global Dimming Appearances Using the Solar Radiation Measurement in Korean Major Cities (Focused on Atmospheric Clearness Analysis))

  • 조덕기;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제27권2호
    • /
    • pp.45-52
    • /
    • 2007
  • Since the atmospheric clearness index is main factor for evaluating global-dimming of atmosphere environment, it is necessary to estimate its characteristics all over the major cities in Korea. We have begun collecting clearness index data since 1982 at 16 different cities and considerable effort has been made for constructing a standard value from measured data at each city. The new clearness data for global-dimming analysis will be extensively used by evaluating atmospheric environment as well as by solar PV application system designer or users. From the results, we can conclude that 1) Yearly mean 61.9% of the atmospheric clearness index was evaluated for clear day all over 2) A significant difference of atmospheric clearness index is observed between 1982-1989 and 1990-1997, 1998-2005 through 16 different cities in Korea.

Can cities become self-reliant in energy? A technological scenario analysis for Kampala, Uganda

  • Munu, Nicholas;Banadda, Noble
    • Environmental Engineering Research
    • /
    • 제21권3호
    • /
    • pp.219-225
    • /
    • 2016
  • Energy self-reliance is important for economic growth and development for any nation. An energy self-reliance technological analysis for Kampala the capital city of Uganda is presented. Three renewable energy sources: Municipal Solid Waste (MSW), solar and wind are assessed for the period of 2014 to 2030. Annual MSW generation will increase from $6.2{\times}10^5$ tons in 2014 to $8.5{\times}10^5$ and $1.14{\times}10^6$ tons by 2030 at 2% and 3.9% population growth respectively. MSW energy recovery yield varies from 136.7 GWh (2014, 65% collection) to 387.9 GWh (2030, 100% collection). MSW can at best contribute 2.1% and 1.6% to total Kampala energy demands for 2014 and 2030 respectively. Wind contribution is 5.6% and 2.3% in those respective years. To meet Kampala energy demands through solar, 26.6% of Kampala area and 2.4 times her size is required for panel installation in 2014 and 2030 respectively. This study concludes that improving renewable energy production may not necessarily translate into energy self-reliant Kampala City based on current and predicted conditions on a business as usual energy utilization situation. More studies should be done to integrate improvement in renewable energy production with improvement in efficiency in energy utilization.

부산광역시 공동주택의 외피구조에 따른 에너지 소비특성 분석 (A Study on the Energy Consumption Characteristic by Building Envelope of Apartment Housing in Busan Metropolitan City)

  • 이정재;김환용;김승희
    • 한국태양에너지학회 논문집
    • /
    • 제34권4호
    • /
    • pp.75-81
    • /
    • 2014
  • In this paper we made energy consumption units of glass curtain wall type apartment and general apartment in Busan metropolitan city and compared energy consumption characteristics by building envelope. The monthly electricity consumption units of general apartment were shown in the range of $1.16{\sim}1.51kWh/m^2{\cdot}mon$ which were indicated higher value in January, February, August and September with little variation. On the other hand, in case of glass curtain wall type apartment, monthly electricity consumption units were represented in the range of $1.91{\sim}7.07kWh/m^2{\cdot}mon$ with significant fluctuations monthly, which were outstandingly high in July, August and September. The monthly city gas consumption units of general apartment were found to be in the range of $1.79{\sim}18.07MJ/m^2{\cdot}mon$, while glass curtain wall type apartment were within $0.94{\sim}19.91MJ/m^2{\cdot}mon$. City gas consumption units from December to March were shown highly in both type apartments. The monthly energy consumption units of general apartment were found to be within $14.23{\sim}30.69MJ/m^2{\cdot}mon$, while glass curtain wall type apartment were within $24.49{\sim}68.9MJ/m^2{\cdot}mon$. Energy consumption units of glass curtain wall type apartment were suggested 4.84 times higher than those of general apartment.

자연형 및 설비형 태양열 온수기의 이용특성에 대한 실험적 연구 (The Experimental Research for the Use Characteristics of the Passive and Active type Domestic Solar Hot Water Systems)

  • 이동원;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제33권5호
    • /
    • pp.82-88
    • /
    • 2013
  • There are the stirring test and drain test in the daily performance test to determine the thermal performance of a domestic solar hot water system. The drain test is a test that measures the discharge heating rate while drain the hot water from the top of the storage tank and supply the city water to the bottom of the tank. From the perspective of the user, this drain test is more effective than the stirring test. In this study, the thermal performance were compared through the drain test for a passive type and an active type domestic solar hot water systems consisting of the same storage tank and collectors. At this point, a passive type was used the horizontal storage tanks, and an active type was used vertical storage tank. In the drain test, when the hot water drained up to the reference hot water temperature, an active type which have vertical storage tank represents excellent daily performance than a passive type which have horizontal storage tank regardless of weather conditions. The reason for this is because the vertical storage tank is advantageous to thermal stratification in the tank. After the drain test, the residual heat for the horizontal storage tank was much more than the vertical storage tank, but in the next day the amount of discharged heat were less than the those of vertical storage tank neither. Thus, the solar water heating system which have horizontal storage tank should be adopted preheating control method rather than separate using control method when connected with auxiliary heat source device.

고온 태양열 화학 반응기에서의 메탄-수증기 개질반응 시뮬레이션 (Methane-Steam Reforming Simulation for a High Temperature Solar Chemical Reactor)

  • 고요한;서태범
    • 한국태양에너지학회 논문집
    • /
    • 제29권1호
    • /
    • pp.44-49
    • /
    • 2009
  • Steam reforming of methane in the high temperature solar chemical reactor bas advantage in its heating method. Using concentrated solar energy as a heating source of the reforming reaction can reduce the $CO_2$ emission by 20% compared to hydrocarbon fuel. In this paper, the simulation result of methane-steam reforming on a high temperature solar chemical reactor(SCR) using Fluent 6.3.26 is presented. The high temperature SCR is designed for the Inha Dish-1, a Dish type solar concentrator installed in Songdo city. Basic SCR performance factors are referred to the former researches of the same laboratory. Inside the SCR porous metal is used for a receiver/reactor. The porous metal is carved like a dome shape on the incident side to increase the heat transfer. Also, ring-disc set of baffle is inserted in the porous metal region to increase the path length. Numerical and physical models are also used from the former researches. Methane and steam is mixed with the same mole fraction and injected into the SCR. The simulation is performed for a various inlet mass flow rate of the methane-steam mixture gas. The result shows that the average reactor temperature and the conversion rate change appreciably by the inlet mass flow rate of 0.0005 kg/s.

일기예보를 이용한 일사량 예측기법개발 (Predict Solar Radiation According to Weather Report)

  • 원종민;도근영;허나리
    • 한국항해항만학회지
    • /
    • 제35권5호
    • /
    • pp.387-392
    • /
    • 2011
  • 태양광발전은 독립전원으로써의 가치는 미미하나 도시전체의 탄소발생량 저감 및 화석연료 사용 저감을 위한 분산전원으로써 가치가 매우 높은 전력원이다. 하지만 태양광발전의 경우 기상조건에 따른 발전량 변동이 심하기에 분산전원으로써 효율적으로 사용하기 위해서는 큰 변동폭을 효과적으로 제어하기 위한 실시간 모니터링이 이루어져야 한다. 하지만 태양광발전량을 좌우하는 일사량은 예측치가 존재하지 않기에 이를 예측해야 하고 본 연구에서는 과거의 일사량을 직산분리 하여 구름의 짙은 정도나 두께 등을 유추할 수 있는 대기투과율을 일기예보에서 발표하는 날씨별로 대푯값을 산정하고 이를 일사량 예측식에 대입하여 일사량을 예측하였다. 그리고 실측 일사량 및 CRM(Cloud Cover Radiation Model)기법인 Kasten and Czeplak의 식을 통해 계산된 예측일사량과의 비교를 통해 검증하였다.

자연순환형 태양열 온수기 축열조의 압력식 설계 개조 (Design Modification of a Thermal Storage Tank of Natural-Circulation Solar Water Heater for a Pressurized System)

  • 부준홍;정의국
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.45-54
    • /
    • 2007
  • For a conventional natural-circulation type solar water heater, the pressure head is limited by the height between the storage tank and hot water tap. Therefore, it is difficult to provide sufficient hot water flow rate for general usage. This study deals with a design modification of the storage tank to utilize the tap-water pressure to increase hot-water supply Based on fluid dynamic and heat transfer theories, a series of modeling and simulation is conducted to achieve practical design requirements. An experimental setup is built and tested and the results are compared with theoretical simulation model. The storage tank capacity is 240 l and the outer diameter of piping was 15 mm. Number of tube turns tested are 5, 10, and 15. Starting with initial storage tank temperature of $80^{\circ}C$, the temperature variation of the supply hot water is investigated against time, while maintaining minimum flow rate of 10 1/min. Typical results show that the hot water supply of minimum $30^{\circ}C$ can be maintained for 34 min with tap-water supply pressure of 2.5 atm, The relative errors between modeling and experiments coincide well within 10% in most cases.

국내 대기청명도의 경년변화 (A Change of Yearly Atmospheric Clearness Index in Korea)

  • 조덕기;윤창열;김광득;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제31권1호
    • /
    • pp.87-92
    • /
    • 2011
  • Since the atmospheric clearness index is main factor for evaluating atmosphere environment, it is necessary to estimate its characteristics all over the major cities in Korea. We have begun collecting clearness index data since 1982 at 16 different cities and considerable effort has been made for constructing a standard value from measured data at each city. The new clearness data will be extensively used by evaluating atmospheric environment as well as by solar application system designer or users. Yearly mean 64% of the atmospheric clearness index was evaluated for clear day all over, and significant difference of horizontal global insolation is observed between 1982~1986 and 1987~1991, 1992~1996, 1997~2001, 2002~2009 through 16 different cities in Korea.

바람길 조성을 위한 도시미기후 측정 분석 (A Study on the Micro-climate of the City to Construct Wind Ways)

  • 전지현;박석봉
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.111-118
    • /
    • 2005
  • The purpose of this study is to address the progress of the heat island phenomenon and the scheme to decrease in heat island phenomenon through analysis of micro-climates according to land use and make a plan to construct wind ways. The result is: 1) Analysis of temperature and humidity at 6 spots for 24 hours showed that heat island phenomenon was considerably intense around center road of Gwangju and can be mild through making lakes and green zones. 2) Analysis of the direction and velocity of the wind at 2 spots for 24 hours showed that the direction of the wind at the center of Gwangju was SSW(South-South-West) and average velocity of the it was $1.2{\sim}1.5\;m/s$. To make the inflow of the low-temperature air current from Mt. Mudeung into the city through Gwangju river, efficient management of Gwangju riverside parks should be considered for Gwangju river itself to be wind way. 3) Analysis of mobile temperature measurement on 3 courses for 24 hours showed that the low-temperature air current of Mt. Mudeung and a micro-climate of Gwangju river can lighten thermal storage phenomena of the city in that the temperature was lowest at Gwangju riverside. These outcome is from a day term measurement. So, to figure out accurate condition of heat island phenomenon in Gwangju City, it is needed to have long term measurements and accumulation of those information.