• 제목/요약/키워드: Solar Cell Module

검색결과 343건 처리시간 0.022초

설계적 특성 개선을 위한 Ag 그리드를 가지는 대면적 염료감응형 태양전지의 새로운 디자인 (Thle New Design of a Large Area Dye-sensitized Solar Cell with Ag Grid for Improving a Design Characteristics)

  • 최진영;이임근;홍지태;김미정;김휘영;김희제
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.123-127
    • /
    • 2007
  • Up sizing of dye-sensitized solar cell(DSC) is the important technology to bring about commercialization of DSC. Several studies to obtain a stable large area DSC have been investigated in overseas laboratories, but have been hardly done in our country. In this study, up sizing technology of dye sensitized solar cells(DSCs) was investigated. We investigated low dark current materials for the current collecting grid. From the result, a new DSC module with metal grid was designed, and fabricated. For a new interconnection, both working and counter electrodes are alternately coupled on 10[cm]$\times$7[cm] substrate. We have achieved 68% of fill factor and photoelectric conversion efficiency of around 2.6% as the best results of new designed DSC structure.

EVA(Ethylene Vinyl Acetate) 수지가 태양전지의 장기적인 수명에 미치는 영향에 관한 실험적 연구 (Experimental study on the effects of EVA(Ethylene Vinyl Acetate) for solar cell's long-term life)

  • 김선용
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.397-401
    • /
    • 2015
  • In this study, analysed the characteristics of power drop and surface damage in solar cell through high temperature and humidity test in the 3 case of EVA(ethylene vinyl acetate) and 2 case ribbon thickness. The solar cells were tested during the 500hr in $85^{\circ}C$ temperature and 85% relative humidity conditions, that excerpted standard of PV Module(KS C IEC-61215). Through the EL(Electroluminescence) shots, specimen's surface have partialy damaged. Before and after high humidity and high temperature test, ribbon thickness $200{\mu}m$ EVA1 case power drop rate was 8.463%, EVA2 case was 6.667%, EVA3 case was 6.373%. In the ribbon thickness $250{\mu}m$ EVA1 case power drop rate was 6.521%, EVA2 case was 8.517%, EVA3 case was 6.019%. EVA3 case was the lowest power and FF(fill factor) drop rate at the 2 case of ribbon thickness, because EVA3 is laerger than EVA1 and EVA2 in thickness, elongation and tensile strength.

고분자 보호 필름을 적용한 태양광 모듈의 출력 및 신뢰성에 관한 연구 (A Study on the Output and Reliability Characteristics of Ultra Barrier Film PV Module)

  • 임종록;신우균;윤희상;김용성;주영철;고석환;강기환;황혜미
    • 한국태양에너지학회 논문집
    • /
    • 제39권5호
    • /
    • pp.1-10
    • /
    • 2019
  • Recently, the installation capacity of PV (photovoltaic) systems has been increasing not only field installation but also floating PV, farm land, BIPV/BAPV. For this reason, the new design and materials of PV module are needed. In particular, in order to apply a PV system to a building, lightweight of the PV module is essential. PV modules made of generally used texturing glass are excellent in output and reliability, but there is a limit to the weight that can be reduced. For the lightweight of the PV module, it necessary to use a film instead of a glass. However, the application of film rather than a glass may cause various problems such as decrease in photocurrent by decrease in transmittance and a increase of CTM (cell to module) loss, a degradation of the reliability, and so on. In this paper, PV modules using Ultra barrier film, which is recently a lot of interest as a substitute for a glass, its characteristic analysis and reliability test were conducted. The transmittance and UV characteristics of each material were verified, and the output of the fabricated 1 cell PV module was measured. In addition, 24 cell PV modules were fabricated at the lab-scale and its reliability tests were conducted. As a result of the experiment, the reliability characteristics of the ultra barrier film PV module were excellent, and it was confirmed that it could be used as the front material of the PV module instead of glass

태양광 발전시스템의 온도에 따른 전압-전류 특성 (I-V Characteristics According to Temperature for Photovoltaic Systems)

  • 황준원;이영;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.183-185
    • /
    • 2009
  • In this thesis, output voltage, current and power of solar module were classified by irradiation and module temperature from data of overall operating characteristics collected for one year in order to manage efficient photovoltaic generation system and deliver maximum power. In addition, from these data, correlations between irradiation, module temperature of photovoltaic cell and amount of power given by photovoltaic cell was quantitatively examined to deduce optimization of the design and construction of photovoltaic generation system. The results of this thesis can be summarized as follows. As I-Y characteristics according to a temperature range of 10$\sim$50[], the area of I-V characteristics were increased with an increase in temperature. Since this area corresponds to the power, output power is thought to have increased with temperature.

  • PDF

태양광 발전시스템의 온도에 따른 출력전력 특성 (Output Power Characteristics According to Temperature for Photovoltaic Systems)

  • 박철웅;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.186-188
    • /
    • 2009
  • In this thesis, output voltage, current and power of solar module were classified by irradiation and module temperature from data of overall operating characteristics collected for one year in order to manage efficient photovoltaic generation system and deliver maximum power. In addition, from these data, correlations between irradiation, module temperature of photovoltaic cell and amount of power given by photovoltaic cell was quantitatively examined to deduce optimization of the design and construction of photovoltaic generation system. The results of this thesis can be summarized as follows. As output power characteristics according to a temperature range of 10$\sim$50[], output power was increased with an increase in temperature. Since output power increases with temperature increase, the result corresponds well to the related equation on temperature and output power.

  • PDF

태양광 발전시스템의 일사량에 따른 출력 특성 (Electric Output Characteristics According to Irradiation for Photovoltaic Systems)

  • 왕강;최용성;김향곤;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.189-191
    • /
    • 2009
  • In this thesis, output voltage, current and power of solar module were classified by irradiation and module temperature from data of overall operating characteristics collected for one year in order to manage efficient photovoltaic generation system and deliver maximum power. In addition, from these data, correlations between irradiation, module temperature of photovoltaic cell and amount of power given by photovoltaic cell was quantitatively examined to deduce optimization of the design and construction of photovoltaic generation system. The results of this thesis can be summarized as follows. As output power characteristics according to a irradiation range of $100{\sim}900[W/m^2]$, output power was increased with increasing irradiation. This result corresponds well to the related equation on irradiation and output power.

  • PDF

태양광 발전시스템의 일사량에 따른 전압-전류 특성 (I-V Characteristics According to Irradiation for Photovoltaic Systems)

  • 조재철;최용성;최충석;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.180-182
    • /
    • 2009
  • In this thesis, output voltage, current and power of solar module were classified by irradiation and module temperature from data of overall operating characteristics collected for one year in order to manage efficient photovoltaic generation system and deliver maximum power. In addition, from these data, correlations between irradiation, module temperature of photovoltaic cell and amount of power given by photovoltaic cell was Quantitatively examined to deduce optimization of the design and construction of photovoltaic generation system. The results of this thesis can be summarized as follows. As I-V characteristics according to a irradiation range of 100$\sim$900 $[W/m^2]$, voltage and current were increased with an increase in irradiation. The result is thought of as an increase in output power with increasing irradiation.

  • PDF

대기온도에 따른 태양전지 모듈의 열적 특성에 관한 연구 (Effects of Ambient Temperature on the Thermal Characteristics of Photovoltaic Modules)

  • 김종필;전충환;장영준
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.48-52
    • /
    • 2008
  • The photovoltaic modules are affected by heat. The hotter the PV module, the lower the power output, then the life time will be short. If the cell temperature rises above a certain limit the encapsulating materials can be damaged, and this will degrade the performance of the PV module. This paper presents that the PV module temperature can be estimated by using thermal analysis programs, and demonstrates the thermal characteristics of the PV module.

  • PDF

View Factor를 고려한 마이크로그리드 적용용 고효율 P-Type Si 양면형 태양광 모듈의 출력량 예측 (Power Prediction of P-Type Si Bifacial PV Module Using View Factor for the Application to Microgrid Network)

  • 최진호;김광순;차혜림;김규광;방병관;박소영;안형근
    • 한국전기전자재료학회논문지
    • /
    • 제31권3호
    • /
    • pp.182-187
    • /
    • 2018
  • In this study, 20.8% of a p-type Si bifacial solar cell was used to develop a photovoltaic (PV) module to obtain the maximum power under a limited installation area. The transparent back sheet material was replaced during fabrication with a white one, which is opaque in commercial products. This is very beneficial for the generation of more electricity, owing to the additional power generation via absorption of light from the rear side. A new model is suggested herein to predict the power of the bifacial PV module by considering the backside reflections from the roof and/or environment. This model considers not only the frontside reflection, but also the nonuniformity of the backside light sources. Theoretical predictions were compared to experimental data to prove the validity of this model, the error range for which ranged from 0.32% to 8.49%. Especially, under $700W/m^2$, the error rate was as low as 2.25%. This work could provide theoretical and experimental bases for application to a distributed and microgrid network.

비정질 실리콘 투과형 태양전지를 적용한 BIPV 시스템 발전 성능에 관한 사례 연구 (A Case Study on the Power Performance Characteristics of Building Integrated PV System with Amorphous Silicon Transparent Solar Cells)

  • 정선미;송종화;이성진;윤종호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.49-52
    • /
    • 2009
  • Practical building integrated photovoltaic system built by Kolon E&C has been monitored and evaluated with respect to power generation, which was installed in Deokpyeong Eco Service Area in Deokpyeong, Gyeonggi, Korea. The amorphous silicon transparent PV module in this BIPV system has 44Wp in power output per unit module and 10% of transmittance with the unit dimension with $980mm{\times}950mm$. The BIPV system was applied as the skylight in the main entrance of the building. This study provided the database for the practical application of the transparent thin-film PV module for BIPV system through 11 month monitoring as well as various statistical analyses such as monthly power output and insolation. Average monthly power output of the system was 52.9kWh/kWp/month which is a 60% of power output of the previously reported data obtained under $30^{\circ}$of an inclined PV module facing south(azimuth=0). This lower power output can be explained by the installation condition of the building facing east, west and south, which was resulted from the influence of azimuth.

  • PDF