• 제목/요약/키워드: Solar Air Heater

검색결과 50건 처리시간 0.03초

솔라 타워용 공기식 흡수기를 위한 충진재의 열전달 및 압력 강하 특성 (Characteristics of heat transfer and pressure drops of the fills for solar tower volumetric air receivers)

  • 조자현;이주한;김용;전용한;서태범;강용혁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3389-3394
    • /
    • 2007
  • Characteristics of heat transfer and pressure drops of fills for solar tower volumetric air receivers are experimentally investigated with the material and the thickness. The volumetric air receiver considered in this paper consists of a ceramic tube and fills are inserted in the ceramic tube. Air is used as the working fluid. Two materials, which are a honeycomb(diameter: 100mm, thickness: 30mm) and laminated mesh(diameter: 100mm, thickness: 1mm), are considered as the fills. In order to investigate the characteristics of heat transfer of fills, this volumetric air receiver is heated by an electric heater and air temperatures in ceramic tube are measured. Also, the radiative shields are installed to measure the only air temperature. In addition, the pressure losses are measured with the thickness of fills while the air goes through the fills inserted in an acrylic tube. The flow becomes turbulent and fully developed in front of the fills. The results show that the heat transfer and pressure drop characteristics of the laminated mesh are superior to those of the honeycomb.

  • PDF

태양열온수기 적용 냉난방시스템의 CFD를 이용한 실내환경 평가 -제1보 바닥면적과 환기횟수를 중심으로- (Estimation of Indoor Environment using CFD of Multi-Purpose System with a Solar Collector -Part 1, focused on floor area and number of ventilation-)

  • 김종열;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.55-61
    • /
    • 2007
  • This paper has been conducted to estimate cooling capacity of the dehumidification tower using hot water from a solar water heating system as a energy source of regeneration process when the dehumidification and drying system is applied to room cooling. A solar water heating system was operated and indoor temperature distributions were simulated according to weather conditions when the concerned solution was used to dehumidify room air in the dehumidification tower. Through this simulation researches we found th following results ; It was found that air velocity through supply and return diffusers should be controlled because it can cause uncomfort in dwelling area. It was found that in the sunny morning temperatures of dwelling area 1 and 2 are higher than those of dwelling area 3 and 4. In this research all the calculation results of heating and cooling system supported by solar water heater have confirmed that its cooling capacity could not reach PMV 0, thermal comfort.

V 형 rib과 dimple로 구성된 SAH 덕트에서의 총괄 열성능에 대한 수치적 연구 (Numerical study on overall thermal performance in SAH duct with compound roughness of V-shaped ribs and dimples)

  • 아닐 쿠마르;김만회
    • 한국태양에너지학회 논문집
    • /
    • 제35권4호
    • /
    • pp.43-55
    • /
    • 2015
  • This paper presents the thermal hydraulic performance of a three dimensional rib-roughened solar air heater (SAH) duct with the one principal wall subjected to uniform heat flux. The SAH duct has aspect ratio of 12.0 and the Reynolds number ranges from 2000 to 12000. The roughness has relative rib height of 0.045, ratio of dimple depth to print diameter of 0.5 and rib pitch ratio of 8.0. The flow attack angle is varied from $35^{\circ}$ to $70^{\circ}$. Various turbulent flow models are used for the heat transfer and fluid flow analysis and their results are compared with the experimental results for smooth surfaces. The computational fluid dynamics (CFD) results based on the renormalization k-epsilon model are in better outcomes compared with the experimental data. This model is used to calculate heat transfer and fluid flow in SAH duct with the compound roughness of V-shaped ribs and dimples. The overall thermal performance based on equal pumping power is found to be the highest (2.18) for flow attack angle of $55^{\circ}$. The thermo-hydraulic performance for V-pattern shaped ribs combined with dimple ribs is higher than that for dimple rib shape and V-pattern rib shape air duct.

자연순환형 태양열온수기 동파방지기술 (Freeze Protection for Passive Solar Water Heating System)

  • 김종현;홍희기;정재동
    • 설비공학논문집
    • /
    • 제23권5호
    • /
    • pp.327-333
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and shortage of excessive electric power consumption. In the experimental device, hot water in storage tank was used to heat the outlet pipe from the tank if the pipe surface temperature falls lower than a set point. The cold water pipe to the storage tank was installed to directly contact the hot water pipe surface temperature rose by transferred heat.

Analysis on the Effect of Thermal Performance with Various Load Patterns for Solar Hot Water Heating System

  • Kim, Byoung-Gi;Jang, Hwan-Young;Chung, Kyung-Taek;Suh, Jeong-Se
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권3호
    • /
    • pp.108-113
    • /
    • 2007
  • The performance of a solar water heater incorporating evacuated tubes was evaluated using a transient simulation program, TRNSYS. Simulations were performed for $60^{\circ}C$ of hot water load temperature and for 280 liter of daily hot water volumes and three 400 liter of storage tank volumes. Three patterns of daily hot water consumption profile were used in the present study (morning, lunch and evening). The results show that the increase in solar fraction depends on the load profile, as well as the collector efficiency coefficient. Hot water draw profile has a large effect on the performance of the SDHWS, the morning load profile has the highest solar fraction. The annual solar fraction of the system, at the weather conditions of Jinju is approximately 84% at lunch load pattern, the 280 kg of load volume, 400 kg of tank volume and the $60^{\circ}C$ of load temperature.

단독주택용 태양열/지열 융복합시스템의 태양열 급탕성능 평가 (An Evaluation of the Solar Thermal Performance of the Solar/Geo Thermal Hybrid Hot Water System for a Detached House)

  • 백남춘;한승현;이왕제;신우철
    • 설비공학논문집
    • /
    • 제27권11호
    • /
    • pp.581-586
    • /
    • 2015
  • In this study, an analysis was performed on the performance of the solar water heating system with geo-thermal heat pump for a detached house. This system has a flat plate solar collector ($8\;m^2$) and a 3 RT heat pump. The heat pump acts as an auxiliary heater of the solar water heating system. These systems were installed at four individual houses with the same area of $100\;m^2$. The monitoring results for one year are as follows. (1) The average daily operating time of the solar system appeared to be 313 minutes in spring (intermediate season), and 135 minutes and 76 minutes in winter and summer respectively. The reason for the short operating time in summer is the high storage temperature due to low water heating load. The high storage temperature is caused by a decrease in collecting efficiency as well as by overheating. (2) The geothermal heat pump as an auxiliary heater mainly operates on days of poor insolation during the winter season. (3) Despite controlling for total house area, hot water consumption varies greatly according to the number of people in the family, hot water usage habits, etc. (4) The yearly solar fraction was 69.8 to 91.5 percent, which exceeds the maximum value of 80% as recommended by ASHRAE. So the solar collector area of $8\;m^2$ appeared to be somewhat greater for the house with an area of $100\;m^2$. (5) The observed annual efficiency of solar systems was relatively low at 13.5 to 23.6%, which was analyzed to be due to the decrease in thermal efficiency and the overheating caused by a high solar fraction.

강제순환 방식의 공기가열식 태양열 집열기의 성능분석에 관한 수치해석 연구 (A Numerical Study on the Performance Analysis of a Solar Air Heating System with Forced Circulation Method)

  • 박형수;김철호
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.122-126
    • /
    • 2017
  • 태양열 에너지를 이용하여 단순한 형태의 공기가열식 집열기를 이용하여 공기를 가열하고 이를 활용하여 생활공간의 난방문제를 해결하기 위한 장치를 개발하는데 목적을 두고 진행되고 있다. 현 시점에서 연구는 모델로 개발한 공기가열식 태양열에너지 집열기의 크기 변화에 따른 가용한 에너지의 량을 이론적으로 산출해 보고 이를 통해 개발 시스템의 가능성을 판단하고자 한다. 본 연구에서는 공기가열식 태양열 집열기의 공기가열성능을 판단하기 위하여, 특정 크기의 태양열 집열기에 일정한 일사량을 투하하였을 때, 모델 집열기 내부에서의 열전달 특성변화와 이를 통해 생산되는 공기의 온도($^{\circ}C$)와 생산량(kg/h)을, 유한체적법(Finite Volume Method)을 적용한 범용 열유동해석(CFD) 프로그램인 영국 CHAM사의 PHOENICS(1)를 이용하여, 분석한 결과를 구하였다. 분석한 결과에서 알 수 있듯이 집열기의 크기가 ($1.2m{\times}1.1m{\times}0.19m$)의 집열기에서 알루미늄으로 제작하는 내경 0.1m의 공기 가열관을 이용하여 가열할 수 있는 공기의 온도는 약 $40.5^{\circ}C$이며 이때 생산되는 공기의 생산량은 약 $161m^3/h$으로 산출되었다. 본 모델장치는 충분히 태양의 열에너지를 이용하여 실내공간의 온도를 인간이 활동하기에 적합한 활동의 환경을 유지하는데 활용할 수 있다고 판단된다.

태양 복사에너지 충진재 변화에 따른 고온 태양열 공기식 흡수기의 열전달 성능 해석 (Heat transfer performance with different fills as volumetric air receivers for concentrated solar radiative energy)

  • 이주한;김용;전용한;서태범;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제27권2호
    • /
    • pp.71-78
    • /
    • 2007
  • The heat transfer characteristics of solar tower receivers are experimentally investigated with receiver shapes. Generally, these become different according to the shapes and materials of the volumetric air receiver. In order to study these effects, the apparatus adopting laminated mesh and honeycombs as the volumetric air receiver is proposed. The receiver consists of laminated mesh (diameter; 100 mm, thickness; 1 mm), honeycombs (diameter; 100 mm, thickness; 30 mm) inserted into ceramic tube (inside diameter; 100 mm, outside diameter; 120 mm, length: 1000 mm). To apply heat to the receiver, an electric heater is used. To find out the heat transfer characteristics of the laminated mesh, the air temperatures are obtained by installing 3 thermocouples on each layer, dividing ceramic tube into 4 layers. Also, a radiative shield is installed to measure the only air temperature. The data for laminated mesh and honeycomb thickness of 30, 60, 90 mm are obtained. The results show that the temperature of layer 3 is higher than those of layer 2 and layer 1.

태양열 냉방 및 급탕 시스템의 제어 조건에 따른 열성능 (Thermal Performance of Solar Cooling & Hot-water System According to Control Condition)

  • 이호;주홍진;김상진;곽희열
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.214-219
    • /
    • 2008
  • This study is describes thermal performance of solar cooling and hot water for demonstration system with ETSC(Evacuated tubular solar collector) installed at Seo-gu culture center of Kwanju. Control condition for solar cooling and hot water system is changed by connection of auxiliary heater. Demonstration system was connected to central air conditioning system. Demonstration system was operated by two types. First type(A) was operated to cooling and hot water supply in that order. Second type(B) was operated to hot water supply and cooling in that order. As a result. it was indicated that the total solar energy consumption of (A) was 799 MJ and the solar energy consumption rate for the cooling and hot water supply was 70% and 30% respectively. Total solar energy consumption of (b) was 898 MJ and the solar energy consumption rate for the cooling and hot water supply was 31% and 69% respectively.

  • PDF

여름철 냉방/제습시스템 중 태양열 온수기를 적용할 수 있는 액체흡수제의 재생성능에 관한 연구(실험계획법에 의한 요인효과 분석에 관하여) (Study on the Regenerating Performance of Liquid Desiccant in the Cooling/Dehumidification System able to use a Solar Water Heater in Summer(On the Analysis of Source Effect by the Design of Experiments))

  • 최광환;김보철;김영진
    • 한국태양에너지학회 논문집
    • /
    • 제22권1호
    • /
    • pp.1-8
    • /
    • 2002
  • With the possibility of hot water being able to be used as a heating source in a liquid desiccant system, an experimental apparatus for regeneration of the liquid desiccant was set up and series of experiments were conducted in a climate-controlled chamber. This study was performed to ascertain the influences of experimental factors on regenerating performance and to suggest the optimal combination of factors affecting regeneration rate. Furthermore. in order to figure out the contribution ratio of the factors on regenerating performance, a multi-way factorial design among the design of experiments was adopted. According to experimental results, the most influential factor on regenerating performance was temperature of the liquid desiccant and its contribution ratio was about 79.4%. In addition. the optimal operating combination was as follows; $60^{\circ}C$ of solution temperature, $14\ell$/min of solution flow rate, and 190m3/h of air volume.