• Title/Summary/Keyword: Soil-remediation

Search Result 794, Processing Time 0.022 seconds

The counter-ion effect in surfactant-based remediation

  • 이달희;손양래;서창일;전권호;유순영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.89-91
    • /
    • 2002
  • 본 연구는 소수성 유기물로 오염된 지하수를 복원할경우, 식품등급의계면활성제와 NaOH 또는 NaCl 의 효과를 연구하기 위하여 주상실험을 실시하였다. 실험결과 게면활성제와 NaOH의 혼합 사용이 가장 효과적이었으며, $Na^{+}$의 counter-ion 효과보다는 OH-의 pH효과가 더욱 중요한 인자가 됨이 밝혀졌다.

  • PDF

Environmental Assessment and Decision of Remediation Scope for Arsenic Contaminated Farmland Soils and River Deposits Around Goro Abandoned Mine, Korea (토양 정밀 조사에 의한 고로폐광산 주변 비소오염 토양 및 하천퇴적토의 오염도 평가 및 오염 토양 복원 규모 설정)

  • 차종철;이정산;이민희
    • Economic and Environmental Geology
    • /
    • v.36 no.6
    • /
    • pp.457-467
    • /
    • 2003
  • Soil Precise Investigation(SPI) for river deposits and farmland soils around Goro abandoned Zn-mine, Korea was performed to assess the pollution level of heavy metals(As. Pb, Cd, Cu) and to estimate the remediation volume for contaminated soils. Total investigation area was about 950000 $m^2$, which was divided into each section of 1500 $m^2$ corresponding to one sampling site and 545 samples for surface soil(0-10cm in depth) and 192 samples for deep soil(10-30cm in depth) from the investigation area were collected for analysis. Concentrations of Cu, Cd, Pb at all sample sites were shown to be lower than Soil Pollution Warning Limit(SPWL). For arsenic concentration, in surface soils, 20.5% of sample sites(104 sites) were over SPWL(6mg/kg) and 6.7%(34 sites) were over Soil Pollution Counterplan Limit(SPCL: 15mg/kg) suggesting that surface soils were broadly contaminated by As. For deep soils, 10.4% of sample sites(18 sites) were over SPWL and 0.6%(1 site) were over SPCL. Four pollution grades for sample locations were prescribed by the Law of Soil Environmental Preservation and Pollution Index(PI) for each soil sample was decided according to pollution grades(over 15.0 mg/kg, 6.00-15.00 mg/kg, 2.40-6.00 mg/kg, 1.23-6.00 mg/kg). The pollution contour map around Goro mine based on PI results was finally created to calculate the contaminated area and the remediation volume for contaminated soils. Remediation area with over SPWL concentration was about 0.3% of total area between Goro mine and a projected storage dam and 0.9% of total area was over 40% of SPWL. If the remediation target concentration was determined to over background level concentration, 1.1% of total area should be treated for remediation. Total soil volume to be treated for remediation was estimated on the assumption that the thickness of contaminated soil was 30cm. Soil volume to be remediated based on the excess of SPWL was estimated at 79,200$m^3$, soil volume exceeding 40% of SPWL was about 233,700 $m^3$, and soil volume exceeding the background level(1.23 mg/kg) was 290,760 TEX>$m^3$.

A study on Surfactants for Electrokinetic Soil Remediation (동전기적 토양복원에 적합한 계면활성제의 선정)

  • 이현호;박지연;김상준;이유진;양지원
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 2003
  • Three different surfactants, APG, Brij30, and SDS, were tested to study the characteristics of sorption on soil surfaces, washing ability, biodegradability, and electrokinetic removal. Kaolinite and phenanthrene were selected as a model soil and a representative HOC, respectively. Phenanthrene was sorbed on kaolinite up to 2,200 mg/kg dry soil. The APG, Brij30, and SDS were sorbed on soil to 40, 7, and 4g/kg soil, respectively. The washing ability of phenanthrene was in order of Brij30>SDS>APG. The biodegradability tested with sludge was in order of APG>Brij30>SDS. In the electrokinetic test, the highest removal efficiency was obtained with APG that exhibited the highest electroosmotic flow. To increase the removal efficiency of HOC in the electrokinetic remediation, the most important factor was the selection of surfactant which maximized the electroosmotic flow.

Soil-Vapor Survey on Soil-Remediation by EMPLEX Collector (EMPLUX Collector에 의한 토양 오염 가스 조사)

  • Kim, Jung-Sung
    • Journal of Environmental Science International
    • /
    • v.17 no.1
    • /
    • pp.119-128
    • /
    • 2008
  • Laboratory analytical results of 22 sets of hydrophobic adsorbent coils containing surface soil-vapor and two soil samples collected by conventional intrusive method from each boring location at two active dry cleaning facilities in the State of Illinois, U.S.A, were presented to evaluate the performance of soil-vapor survey. The most critical factor to determine the effectiveness of soil-vapor survey is the distance from the soil-vapor sampling device to the actual contamination, which is a function of soil porosity, permeability, primary lithology, and other geological and hydrogeological site-specific parameters. Also this factor can be affected by the history of contaminant-generating operations. The laboratory analytical results in this study showed longer dry cleaning operation history (i.e., 50 years) and presence of fine sand at the beneath Site B allow the contaminants to migrate farther and deeper over a fixed time compared to Site A(i.e., 35 years and silty clay) so that the soil-vapor survey is not likely the most effective environmental site investigation method alone for Site B. However, for Site A, the soil-vapor survey successfully screened the site to identify the location reporting the highest soil concentration of chlorinated solvents.

Effect of Acid Buffering Capacity and Soil Component Remediation of Soil Contaminated with Phenanthrene using Electrokinetic-Fenton Process (산 완충능력과 토양 성분이 동전기-펜톤 공정에 의한 phenanthrene 오염토양 정화에 미치는 영향)

  • Kim, Jung Hwan;Na, So Jeong;Park, Joo Yang;Byun, Young Deog
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.1
    • /
    • pp.129-136
    • /
    • 2013
  • This research was conducted to investigate effects of acid buffering capacity and soil component in treatment of phenanthrene using electrokinetic-Fenton process. In Hadong clay of high acid buffering and low iron oxide content, it was difficult to oxidize phenanthrene due to shortage of iron catalyst and scavenger effect of carbonate minerals. The desorbed phenanthrene conductive to Fenton oxidation was transported toward cathode by electroosmotic flow. However, in Youngdong illitic clay, oxidation of phenanthrene near anode readily occurred compared to Hadong clay due to high iron content and low acid buffering capacity.

초음파동전기세척 복합기법에 의한 오염부지 복원기술

  • 정하익;김상근;송봉준;강동우;이경국
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.183-185
    • /
    • 2004
  • In this study, the combined electrokinetic and ultrasonic remediation technique, ultrasonically enhanced electrokinetic technique, was studied for the removal of heavy metal and organic substance in contaminated soils. The electrokinetic technique has been applied to remove mainly the heavy metal and the ultrasonic technique has been to remove mainly organic substance in contaminated soil. The laboratory soil flushing tests combined electrokinetic and ultrasonic technique were conducted using specially designed and fabricated devices to determine the effect of these both techniques. A series of laboratory experiments involving the simple, electrokinetic, ultrasonic, and electrokinetic & ultrasonic flushing test were carried out. A soil admixed with sand and kaolin was used as a test specimen, and Pb and ethylene glycol were used as contaminants of heavy metal and organic substance. An increase in out flow, permeability and contaminant removal rate was observed in electrokinetic and ultrasonic flushing tests. Some practical implications of these results are discussed in terms of technical feasibility of in situ implementation of electrokinetic ultrasonic remediation technique.

  • PDF

유류오염 토양의 복원을 위한 열탈착 처리기술

  • 유동준;김영웅;박용규;오방일;구자공
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.111-114
    • /
    • 2001
  • Thermal desorption process is valuable for the remediation of oil contaminated site. The system is physical separation process by volatizing oil contaminants from soil matrixes and is not designed to provide high levels of oil destruction. The process is not incineration, because the decomposition of oil materials is not the desired result, although some decomposition may occur. The physical and chemical properties that influence the design and operation of the system include boiling points, soil sorption characteristics, aqueous phase solubility, thermal stability, contaminating oil concentration, moisture contents, particle size distribution and etc.

  • PDF

The Study of Cd and Pb Characteristics on Electrokinetic Remediation of Mine Deposit (Electrokinetic 기법에 의한 광산퇴적토내 Cd과 Pb의 제거 특성에 관한 연구)

  • 윤삼석;신현무;이창언
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.61-64
    • /
    • 2001
  • In the remediation of contaminated soil by electrokinetic process, transport characteristics of contaminants are major factors. Pb is highly fixed to entire soil and not moved readily. High concentration of Cd was analyzed in the cathodic section but anodic section's concentration was lower than initial concentration. Although the Cd had high treatment effect, 50% of total mass was concentrated in cathodic section and was not flowed out readily. Most of transported Cd may be adsorbed in the cathodic side soil due to increased pH at adjacent to catholyte.

  • PDF

A Study on the New Method by EMPLUX for Soil-Remediation(1) (토양오염 복원을 위한 EMPLUX를 사용한 새로운 방법에 대한 연구)

  • Kim, Jung-Sung
    • Journal of Environmental Science International
    • /
    • v.16 no.12
    • /
    • pp.1325-1335
    • /
    • 2007
  • The utility of soil-gas surveys is directly proportional to their accuracy in reflecting and representing changes in the subsurface concentrations of source compounds. Passive soil-gas vapor-phase is merely a fractional trace of the source, so, as a matter of convenience, the units used in reporting detection values from EMFLUX surveys are smaller than those employed for source-compound concentrations. According to the Leaking Underground Storage Tank(LUST) Program Annual Report, approximately 16 U.S. million dollars were spent for environmental site investigations at over 1,600 Underground Storage Tank(UST) sites and approximately over 1,000 acres of land was characterized and remediated in the State of Illinois in the year of 2003 alone. The main purpose of this study is to propose an idea to significantly reduce the site investigation cost by utilizing a passive soil-gas survey and conventional intrusive drilling method and to fully define the three dimensional characteristics of subsurface contamination from two industrial drycleaning facilities.

토양경작법을 이용한 유류오염 토양 복원시 미생물제제 적용 효과

  • 환경보전협회
    • Bulletin of Korea Environmental Preservation Association
    • /
    • v.26 no.5_6
    • /
    • pp.59-61
    • /
    • 2004
  • Landfarming and a microbial agent were used to treat dilsel-contaminated soil. The microbial agent was applied to the contaminated soil in a concentration of 5$\times$102 cfu/soil(g) and the total amount of microbial agent, 210 l , was sprinkled on the soil four times for 24 days during 50 day-remediation period. The remediation goal, lower than 800mg/kg of TPH, was achieved from 5,707mg/kg of TPH within 50 days. The total number and activity of indigenous microorganisms were increased by 100 times after the microbial agent, Bioil-D, was applied to the contaminated soil.

  • PDF