• 제목/요약/키워드: Soil moisture model

검색결과 431건 처리시간 0.031초

Comparison of Remote Sensing and Crop Growth Models for Estimating Within-Field LAI Variability

  • Hong, Suk-Young;Sudduth, Kenneth-A.;Kitchen, Newell-R.;Fraisse, Clyde-W.;Palm, Harlan-L.;Wiebold, William-J.
    • 대한원격탐사학회지
    • /
    • 제20권3호
    • /
    • pp.175-188
    • /
    • 2004
  • The objectives of this study were to estimate leaf area index (LAI) as a function of image-derived vegetation indices, and to compare measured and estimated LAI to the results of crop model simulation. Soil moisture, crop phenology, and LAI data were obtained several times during the 2001 growing season at monitoring sites established in two central Missouri experimental fields, one planted to com (Zea mays L.) and the other planted to soybean (Glycine max L.). Hyper- and multi-spectral images at varying spatial. and spectral resolutions were acquired from both airborne and satellite platforms, and data were extracted to calculate standard vegetative indices (normalized difference vegetative index, NDVI; ratio vegetative index, RVI; and soil-adjusted vegetative index, SAVI). When comparing these three indices, regressions for measured LAI were of similar quality $(r^2$ =0.59 to 0.61 for com; $r^2$ =0.66 to 0.68 for soybean) in this single-year dataset. CERES(Crop Environment Resource Synthesis)-Maize and CROPGRO-Soybean models were calibrated to measured soil moisture and yield data and used to simulate LAI over the growing season. The CERES-Maize model over-predicted LAI at all corn monitoring sites. Simulated LAI from CROPGRO-Soybean was similar to observed and image-estimated LA! for most soybean monitoring sites. These results suggest crop growth model predictions might be improved by incorporating image-estimated LAI. Greater improvements might be expected with com than with soybean.

수치해석과 모형실험을 통한 매립배관에서의 유도초음파 L(0,2) 모드의 감쇠 특성 평가 (Attenuation Characterization of L(0,2) Guided Wave Mode through Numerical Analyses and Model Experiments with Buried Steel Pipe)

  • 이주원;나원배
    • 한국해양공학회지
    • /
    • 제27권1호
    • /
    • pp.16-23
    • /
    • 2013
  • By carrying out numerical analyses and model experiments, this paper presents the attenuation characterization of an L(0,2) guided ultrasonic wave propagating in a buried steel pipe. From this investigation, we first find that the L(0,2) mode has a better attenuation property. Second, it is shown from the numerical analyses that the attenuation increases with increases in the soil embedment length (0, 500, 1000, and 1500 mm) and degrees of saturation (0, 50, 99, and 100%). Third, it is also shown from the model experiment that the attenuation increases as the embedment lengths and soil moisture quantities (0, 10, 20, and 30 kg) increase. Finally, we find that an exponential extrapolation gives a better attenuation prediction because the extrapolation gives similar attenuation patterns between the numerical and experimental results.

선행토양함수조건(AMC)을 고려한 L-THIA WWW 직접유출 모의 정확성 평가 (Evaluation of L-THIA WWW Dimet Runoff Estimation with AMC Adjustment)

  • 김종건;박윤식;전지홍;;안재훈;박영곤;김기성;최중대;임경재
    • 한국물환경학회지
    • /
    • 제23권4호
    • /
    • pp.474-481
    • /
    • 2007
  • With population growth, industrialization, and urbanization within the watershed, the hydrologic response changed dramatically, resulting in increases in peak flow with lesser time to peak and total runoff with shortened time of concentration. Infiltration is directly affected by initial soil moisture condition, which is a key element to determine runoff. Influence of the initial soil moisture condition on hydrograph analysis should be evaluated to assess land use change impacts on runoff and non-point source pollution characteristics. The Long-Term Hydrologic Impact Assessment (L-THIA) model has been widely used for the estimation of the direct runoff worldwide. The L-THIA model was applied to the Little Eagle Creek (LEC) watershed and Its estimated direct runoff values were compared with the BFLOW filtered direct runoff values by other researchers. The $R^2$ value Was 0.68 and the Nash-Sutcliffe coefficient value was 0.64. Also, the L-THIA estimates were compared with those separated using optimized $BFI_{max}$ value for the Eckhardt filter. The $R^2$ value and the Nash-Sutcliffe coefficient value were 0.66 and 0.63, respectively. Although these higher statistics could indicate that the L-THIA model is good in estimating the direct runoff reasonably well, the Antecedent Moisture Condition (AMC) was not adjusted in that study, which might be responsible for mismatches in peak flow between the L-THIA estimated and the measured peak values. In this study, the L-THIA model was run with AMC adjustment for direct runoff estimation. The $R^2$ value was 0.80 and the Nash-Sutcliffe coefficient value was 0.78 for the comparison of L-THIA simulated direct runoff with the filtered direct runoff. However there was 42.44% differences in the L-THIA estimated direct runoff and filtered direct runoff. This can be explained in that about 80% of the simulation period is classified as 'AMC I' condition, which caused lower CN values and lower direct runoff estimation. Thus, the coefficients of the equation to adjust CN II to CN I and CN III depending on AMC condition were modified to minimize adjustments impacts on runoff estimation. The $R^2$ and the Nash-Sutcliffe coefficient values increase, 0.80 and 0.80 respectively. The difference in the estimated and filtered direct runoff decreased from 42.44% to 7.99%. The results obtained in this study indicate the AMC needs to be considered for accurate direct runoff estimation using the L-THIA model. Also, more researches are needed for realistic adjustment of the AMC in the L-THIA model.

열펌프에 의한 그린하우스 난방시스템의 열특성과 시뮬레이션 모델개발 (Thermal Characteristics and Simulation Model Development for Greenhouse Heating System with Heat Pump)

  • 노정근;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제26권2호
    • /
    • pp.155-162
    • /
    • 2001
  • The greenhouse heating system with heat pump was built for development of simulation model and validation. The computer simulation model for the system to predict temperature of air and soil and moisture content of soil in the greenhouse were developed, and its validity was justified by actual data. From the analysis of experimentally measured data and the simulation output, following results were obtained. 1. The expected values of inside air temperature for the heating system with heat pump were very much close to the experimental values. 2. In the heating system with heat pump, the expected values of day time surface temperature of soil by computer simulation were very much similar to the measured values, but those of night time were higher than the measured value by at most 2.0$\^{C}$. 3. The simulation model predicted temperature of greenhouse film as of 1$\^{C}$ below than the mean value of ambient air and greenhouse air temperature. 4. Heat loss value of daytime was found to be larger than that of nigh as much as 1.3 to 2.3 times for the heating system with heat pump. 5. In the heating system with heat pump, when the lowest ambient temperature was -8$\^{C}$∼-7$\^{C}$ the air temperature of greenhouse was 5$\^{C}$∼6$\^{C}$, thus the heat pump heating system contributed in greenhouse heating by 13$\^{C}$.

  • PDF

Bentonite에 근입된 앵커의 Creep 특성 (Creep of Plate Anchors Embedded in Bentonite)

  • 신방웅;이준대;신진환;이봉직
    • 한국안전학회지
    • /
    • 제10권4호
    • /
    • pp.3-8
    • /
    • 1995
  • Anchors find their use in providing tie-back resistance for submerged footings, transmission towers, tunnels and ocean structures. Laboratory model teats were performed for the short-term net ultimate uplift capacity of a circular anchors with respect to various embedment depths and moisture content in saturated bentonite. The tests have been conducted with the anchor at two different moisture contents. Based an the model test results, empirical relationships between the net load, rate of strain, and time have been developed. Test results are as follows. 1) In creep tests for load versus ultimate uplift capacity, the displacement of plate anchors rapidly increases during the primary stage but thereafter becomes constant over a period of time. 2) Displacement increased with the increase of the sustain load and embedded ratio in soil. 3) If the load is less than or equal to 75% of the short-term ultimate uplift capacity, a complete pullout does not occur due to creep.

  • PDF

낙동강 수계 유출분석을 위한 강우-유출 모형의 매개변수 산정 (Estimation and Analysis of Parameters for Rainfall-Runoff Model on the Nakdong River)

  • 맹승진;이순혁;류경식;송기헌
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.266-271
    • /
    • 2005
  • In this study, following works have been carried out : division of Nakdong River Basin into 25 sub basins, development of a technique to evaluate spatial distribution of rainfall and analysis of rainfall data of 169 stations, selection of control points, and selection of a hydrologic model(SSARR). The runoff analysis showed that the surface-subsurface separation and soil moisture index parameters are the most important two to the simulation result.

  • PDF

불포화토의 거동예측을 위한 구성식 개발(I) -불포화토의 거동특성 연구- (Development of Constitutive Model for the Prediction of Behaviour of Unsaturated Soil(I) -Study of Characteristics of Unsaturated Soil-)

  • 송창섭;장병욱
    • 한국농공학회지
    • /
    • 제36권4호
    • /
    • pp.87-94
    • /
    • 1994
  • The aim of the work descrihed in this paper is to study a characteristics of an unsaturated soil for the different matric suctions. To this end, a series of suction controlled isotropic and triaxial compression tests is conducted on silty sands. Matric suction is controlled by the axis translation technique using high air entry ceramic disk. Total volume change, air and water volume changes are measured by the device made for the experiment. The specimens are compacted using a half of Proctor compaction energy and with the water contents of 5% drier than the optimum moisture contents. Isotropic compression and triaxial compression tests are conducted on the specimen at each equilibrium state of matric suction. From test results, volume changes and deviator stresses are analyzed at each state and their relationships are formulated.

  • PDF

유역 공간 강우 산정방법에 따른 VfloTM 분포형 강우-유출 모형의 매개변수 평가 - 금호강 동촌 유역을 대상으로 - (Parameter Estimation of VfloTM Distributed Rainfall-Runoff Model by Areal Rainfall Calculation Methods - For Dongchon Watershed of Geumho River -)

  • 김시수;정충길;박종윤;정성원;김성준
    • 한국농공학회논문집
    • /
    • 제55권1호
    • /
    • pp.9-15
    • /
    • 2013
  • This study is to evaluate the parameter behavior of VfloTM distributed rainfall-runoff model by applying 3 kinds of rainfall interpolation methods viz. Inverse Distance Weighting (IDW), Kriging (KRI), and Thiessen network (THI). For the 1,544 $km^2$ Dongcheon watershed of Nakdong river, the model was calibrated using 4 storm events in 2007 and 2009, and validated using 2 storm events in 2010. The model was calibrated with Nash-Sutcliffe model efficiency of 0.97 for IDW, 0.94 for KRI, and 0.95 for THI respectively. For the sensitive parameters, the saturated hydraulic conductivity ($K_{sat}$) for IDW, KRI, and THI were 0.33, 0.31, and 0.43 cm/hr, and the soil suction head at the wetting front (${\Psi}_f$) were 4.10, 3.96, and 5.19 cm $H_2O$ respectively. These parameters affected the infiltration process by the spatial distribution of antecedent moisture condition before a storm.

입지환경인자를 바탕으로 한 편백의 지위지수 추정에 관한 연구 (The Effects of Site Environmental Factors on Estimation of Site Index Function for Chamaecyparis obtusa Endlicher Stands)

  • 김대현;김의경;이성기;정영교;정진현
    • 한국환경과학회지
    • /
    • 제17권8호
    • /
    • pp.891-898
    • /
    • 2008
  • This study was conducted to develop the effects of site environmental factors on estimation of site index function for Chamaecyparis obtusa Endlicher stands. We derived nonlinear growth equation and the draw site index curves by applying this estimated equation. This study with Chapman-Richards function showed significant P-value which was less then 0.0001 and $R^2$ value 0.5947. This study was conducted to develop the feasible site index equation of Chamaecyparis obtusa Endlicher. For the table, the data of 82 sample areas that were thought to be without errors among the data of Chamaecyparis obtusa Endlicher sample area located on the value-oriented forest location chart were used and estimated. After analyzing the quantification method I based on 13 environmental factors to develop the score table for the site-index estimation of Chamaecyparis obtusa Endlicher, $R^2$ value of the model was 0.7555. It has been analyzed that the scope value of Soil moisture in horizon A was 7.5045, that of total soil depth was 6.3896, that of topography was 5.3471, that of slope was 4.7000 and that of aspect was 3.2038. After analyzing the partial correlation to examine the factors that affected most the site-index of Chamaecyparis obtusa Endlicher, it has been noted that the partial correlation of climatic zone was 0.4987, which was highest, and it was followed by Soil moisture in horizon A (0.4592), slope (0.4537), topography (0.3299) and total soil depth (0.1035). As a result of conducting the significance test for partial correlation, it has been found that topography, climatic zone, parent rock, slope, altitude, aspect, Soil moisture in horizon A, soil hardness in horizon A and total soil depth were recognized significant with 1% of significance level and sedimentary type and soil texture in horizon A were recognized significant with 5% of significance level.

병렬 PEST를 이용한 분포형 수문모형의 매개변수 추정: 레이더 및 지상 강우 자료 영향 비교 (Parameter Estimation of a Distributed Hydrologic Model using Parallel PEST: Comparison of Impacts by Radar and Ground Rainfall Estimates)

  • 노성진;최윤석;최천규;김경탁
    • 한국수자원학회논문집
    • /
    • 제46권11호
    • /
    • pp.1041-1052
    • /
    • 2013
  • 본 연구에서는 범용 매개변수 최적화 모형인 PEST를 이용하여 분포형 수문모형인 GRM(grid based rainfall-runoff model) 모형의 매개변수 및 불확실성 범위를 추정하였다. 특히, 레이더 강우 및 지상 관측 강우를 각각 적용하여, 입력자료 차이가 매개변수 추정에 미치는 영향을 분석하였다. 자동 보정 모형은 GUI (graphic user interface)에 대한 접근 없이 모형구동이 가능하도록 개선된 GRM-MP (multiple projects) 버전과 병렬 PEST 버전을 결합하여 매개변수 추정에 소요되는 시간을 단축시켰다. 이를 낙동강 수계 금호강 유역과 감천 유역에 대해 적용하여, 초기 포화도, 지표면 조도계수 및 토양 투수계수의 보정계수에 대해 매개변수 최적화 및 불확실성 추정을 수행하였다. 강우자료 분석 결과, 레이더와 지상 강우의 유역평균 누적시계열은 비슷하거나 지상 강우가 조금 큰 경향을 보였으나, 공간분포에 있어서는 지상 강우에 비해 레이더 강우에서 큰 변동성이 확인되었다. 보정된 수문모의 결과는 레이더 강우 적용 시, 지상 강우에 비해 비슷하거나 더 나은 정확도를 보였다. 추정된 매개변수는 레이더 강우 적용 시, 토양 투수계수의 보정계수가 일관되게 1보다 작은 경향을 보였으며, 이는 강우강도가 강한 격자가 상당수 존재하기 때문으로 판단되었다. 초기 포화도 및 지표면 조도계수의 보정계수는 레이더 및 지상 강우에서 일정한 경향성을 보이지 않았다. 본 연구의 대상 유역 및 호우사상에 대한 PEST의 최적화 모의 결과, 동일 유역 및 호우사상에 대해서도 강우 추정 방법에 따라 서로 다른 최적 매개변수 값을 갖는 것을 알 수 있었으며, 이는 향후 레이더 강우 자료의 수문 모의 활용 시 유의해야할 점으로 판단된다.