• 제목/요약/키워드: Soil decontamination

검색결과 56건 처리시간 0.03초

불포화토의 동전기정화 특성에 관한 실험적 연구 (The Characteristics of Electrokinetic Remediation for Unsaturated Soil)

  • 김병일;김익현;한상재;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.641-646
    • /
    • 2003
  • In this study, a series of electrokinetic(EK) remediation experiments are carried out under the different degree of saturation for contaminated soil with lead. for constant electrical potential, the final current of all the sample represents the similarity to steady-state value of 5∼7mA. Under conditions of all the degree of saturation the anode reservoir becomes acidic(pH as low as 3) while the cathode reservoir is basic(pH as high as 12). But pH changes in the sample is a little and decontamination efficiency is the low.

  • PDF

한국원자력연구원의 해체기술 개발 현황 및 향후 전망 (The Status and Prospect of Decommissioning Technology Development at KAERI)

  • 문제권;김선병;최왕규;최병선;정동용;서범경
    • 방사성폐기물학회지
    • /
    • 제17권2호
    • /
    • pp.139-165
    • /
    • 2019
  • 한국원자력연구원에서 개발 중인 해체기술 현황 및 전망에 대해 기술하였다. 특히, 해체의 핵심기술인 제염, 원격절단, 해체 폐기물처리 및 부지 복원 분야를 중점적으로 다루었다. 제염기술로는 부품제염과 원자력시스템제염 부분을 고찰하였고, 원격절단기술 관련해서는 절단기술, 원격제어 및 해체공정 모사기술이 다루어졌다. 해체 폐기물처리기술 관련해서는, 비록 해체 후 다양한 폐기물이 발생하지만, 주 폐기물인 금속, 가연성폐기물과 난처리성 특수 폐기물인 고염 고방사성 폐액, 유기혼성폐기물 및 우라늄 복합폐기물 처리기술 등을 주로 기술하였다. 마지막으로, 해체부지 복원 분야에서는 방사선 측정, 부지재이용의 안전성평가 그리고 부지 복원기술 등을 중점적으로 기술하였다.

동전기제염장치에서 발생한 폐액의 재사용을 위한 개선된 처리기술 (Improved Treatment Technique for the Reuse of Waste Solution Generated from a Electrokinetic Decontamination System)

  • 김완석;김승수;김계남;박욱량;문제권
    • 방사성폐기물학회지
    • /
    • 제12권1호
    • /
    • pp.1-6
    • /
    • 2014
  • 우라늄으로 오염된 토양을 복원하기 위해 실규모의 동전기제염장치로 제염하는 과정에서 많은 산폐액이 발생한다. 발생한 산폐액에 CaO를 가해 우라늄수산화물을 침전시켜 여과한 다음, 방사성 폐액을 줄이기 위하여 이 용액을 재사용하였다. 그러나 이 용액을 동전기에 재사용할 경우, 높은 농도의 칼슘 때문에 양극실에서 음극실로 용액이동 속도가 감소하여 여과포의 약화, 전선 부식, 음극면에 산화물 부착 등의 문제점이 발생하였다. 이 문제들을 해결하기 위하여 재생액에 황산을 넣어 $CaSO_4$로 침전시켜 칼슘을 제거하였다. 칼슘이 제거된 재생액을 사용하여 소형 동전기 장치에서 20 일간 토양제염 실험을 수행한 결과는 세척후 토양내 우라늄 잔류 농도가 0.35 Bq/g로 감소하였으며, 이는 증류수 제염한 결과와 유사하게 나타났다.

EVALUATION OF FERROCYANIDE ANION EXCHANGE RESINS REGARDING THE UPTAKE OF Cs+ IONS AND THEIR REGENERATION

  • Won, Hui-Jun;Moon, Jei-Kwon;Jung, Chong-Hun;Chung, Won-Yang
    • Nuclear Engineering and Technology
    • /
    • 제40권6호
    • /
    • pp.489-496
    • /
    • 2008
  • Ferrocyanide-anion exchange resin was prepared and the prepared ion exchange resins were tested on the ability to uptake $Cs^+$ ion. The prepared ion exchange resins were resin-KCoFC, resin-KNiFC, and resin-KCuFC. The three tested ion exchange resins showed ion exchange selectivity on the $Cs^+$ ion of the surrogate soil decontamination solution, and resin-KCoFC showed the best $Cs^+$ ion uptake capability among the tested ion exchange resins. The ion exchange behaviors were explained well by the modified Dubinin-Polanyi equation. A regeneration feasibility study of the spent ion exchange resins was also performed by the successive application of hydrogen peroxide and hydrazine. The desorption of the $Cs^+$ ion from the ion exchange resin satisfied the electroneutrality condition in the oxidation step; the desorption of the $Fe^{2+}$ ion in the reduction step could also be reduced by adding the $K^+$ ion.

토양세척폐액 부피감소를 위한 재생방법 연구 (Methods of Recycling Soil Washing Wastewater for Volume Reduction)

  • 김계남;원휘준;오원진
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제8권1호
    • /
    • pp.17-26
    • /
    • 2003
  • TRIGA원자로 주변 토양을 인공적으로 오염시킬 때, 오염용액 내의 코발트농도가 작아짐에 따라 코발트의 흡착평형 계수는 증가했고, 이 오염토양 질량 대 Citrc acid용액 부피 비율률 1:5로 하였을 때 토양제염효율이 높았다. 0.01M, 0.01M, 0.0001M코발트용액으로 오염된 TRIGA토양을 0.01M Citric acid로 Washing한 후의 토양세척액의 코발트 농도는 각각 136.0, 14.0, 1.5 ppm이었다. 화학침전법에 의해 토양세척폐액 내의 코발트농도가 낮아질수록 제거율은 저하했다. 그러나 다량의 NaOH가 첨가되어야 하고 최종침전폐기물의 부피가 오염토양부피의 약 10%정도나 되었다. 이온교환수지법에 의한 재생실험결과 강산성수지를 많이 넣을수록 코발트제염 효율은 증가했고 pH는 감소했다. 코발트농도가 다른 세 종류의 토양세척폐액에 강산성수지를 넣고 흡착실험을 한 결과 일정한 코발트 제거효율을 얻기 위해 필요한 강산성수지의 질량은 모두 거의 일정했다. 즉, 95%이상의 제거효율을 얻기 위해 0.625 g 이상의 강산성수지가 필요했다. 한편, 토양부피의 약9.2%의 다량의 강산성수지 폐기물이 발생하는 것이 문제점이다.

마이크로이멀젼을 이용한 유기오염물로 오염된 지반의 정화 (Remediation of Contaminated Soil with Organic Contaminants using Microemulsion)

  • Park, Ki-Hong;Kwon, Oh-Jung;Park, Jun-Boum
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.597-604
    • /
    • 2003
  • In the soil washing process, the contaminants are usually removed by abrasion from soil particles using mechanical energy and water However, organic contaminants with low water solubility like polycyclic aromatic hydrocarbons (PAH) are remained on soil particles. Previous studies have shown that surfactant possessing amphipathic activity enhances the solubility of organic materials. For this reason solutions with surfactants have been used to improve removal of organic contaminants on soil washing process. But, in this manner, many problems were found like complete loss of surfactants and additional contamination by surfactant. The remediation method using microemulsion has been introduced to overcome these disadvantages. In this case, surfactants are recycled by phase separation of microemulsion after remediation. In microemulsion process, the surfactant will be recycled by phase separation of the microemulsion into a surfactant-rich aqueous phase and an oil phase after extraction. That is why remediation concept applying microemulsion as washing media has been Introduced. Suitable microemulsion have to be used in order to have the chance of refilling the soil after decontamination and to avoid any risk due to toxicity. The purpose of this research is to evaluate effect of microemulsion to remediation of contaminated soil. We performed test with various organic contaminants like Pyrene and BTEX, also compared efficiency of remediation in microemulsion process with soil washing

  • PDF

전기장과 이온교환막을 이용한 토양에서의 중금속 제거에 대한 연구 (A study on the removal of heavy metals from soils using electrokinetic soil processing and ion exchange membrane)

  • 김순오
    • 자원환경지질
    • /
    • 제32권1호
    • /
    • pp.43-51
    • /
    • 1999
  • In order to remediate hazardous waste site, a process of electrokinetically purging chemicals from saturated soil is examined by laboratory experiments. Electrokinetic soil remediation is one of the most promising soil decontamination processes that habe igh removal efficiency and time-effectiveness in low-permeability soils such as clay. Being combined with several mechanisms-electromigration, elec troosmosis, diffusion and electrolysis of water, electrokinetic soil processing can remove non-polar organics as well as ionic contaminants. The objectives of this study are; 1) the exploration of the feasibility of electrokinetic soil processing on the removal of heavy metals, 2) the investigation of applicability to the tailing-soils in aban doned mining area, 3) the examination of effects of soil pH and conductivity on the transport phenomena of elements in soils, and 4) the investigation of the applicability of the ionexchange membrance to the efficient collection of heavy metals removed from contaminated soils. With the result of this study, it is suggested that the removal efficiency is significantly influenced by applied voltage & current, type of purging solutions, soil pH, permeability and zeta potentials of soil. Although further study should be needed, it is possible to collect removed heavy metals with ion-exchange membrance in cathode compartment.

  • PDF

Electrokinetic정화시 토질의 완충능을 고려한 시료내의 pH변화 (pH Variation In Soils Considering Buffer Capacity during Electrokinetic Extraction)

  • 오승록;한상재;김수삼;조성호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.585-590
    • /
    • 2001
  • Physicochemical phenomena in soils are dependent upon pH when using electrokinetic extraction for the contaminants removal especially for heavy metals. pH variation in soils is affected on H$\^$+/ and OH ̄ ions produced by electrolysis reaction and buffer capacity of soil. High amount of heavy metals are retained in the soils if the soil buffer capacity remains high enough to resist a change in pH. Therefore, accurate pH estimation of soil is important in the application of electrokinetic mechanism for decontamination and understanding of subsurface physicochemical characteristics is also required as well as considering buffer capacity for the enhanced methods application. For these, buffer capacity and pH distribution were measured for the four soils, and also compared with modeling results. The results of buffer modeling were good agreement with experimental data. It is showed that four soils were effected by buffer capacity

  • PDF

후쿠시마 원전 사고 이후 일반인의 방사선학적 안전성 확보를 위한 제염폐기물 임시저장시설 이격거리 평가 (Evaluation of Separation Distance from the Temporary Storage Facility for Decontamination Waste to Ensure Public Radiological Safety after Fukushima Nuclear Power Plant Accident)

  • 김민준;고아라;김광표
    • 방사성폐기물학회지
    • /
    • 제14권3호
    • /
    • pp.201-209
    • /
    • 2016
  • 후쿠시마 원전사고 이후 광역의 방사성 오염부지가 발생되었으며, 이에 대한 제염작업으로 인하여 다량의 제염폐기물이 발생하였다. 일본에서는 이를 보관하기 위하여 각 지역에 임시저장시설이 운영되고 있으며, 이들 시설들은 피난지시해제가 이루어진 지역의 일반인에 대하여 방사선학적 영향을 미칠 것으로 판단된다. 본 연구에서는 임시저장시설 인근에 거주하는 일반인의 방사선학적 안전성 확보를 위하여 임시저장시설 특성에 따른 거리별 공간 방사선량률 및 선량제한치를 만족하는 임시저장시설로부터의 이격거리를 평가하였다. 이를 위해 임시저장시설의 형태 및 크기, 복토 두께 등을 고려하였으며, MCNPX를 이용하여 방사선량률을 평가하였다. 복토에 의한 차폐효과는 두께가 10 cm일 때 68.9%, 30 cm일 때 96.9%, 50 cm 일 때 99.7%로 나타났다. 임시저장시설 형태에 따른 공간 방사선량률은 지상 보관형일 때 가장 높게 나타났으며, 이어서 반지하 보관형, 지하 보관형일 순으로 나타났다. 임시저장시설 크기에 따른 공간 방사선량률은 $5{\times}5{\times}2m$ 시설을 제외한 시설에 대하여 유사하게 나타났다. 이는 임시저장시설 내 적재된 제염폐기물에 의하여 자기차폐가 이루어지기 때문이다. 최종적으로 크기가 $50{\times}50{\times}2m$이고, 복토가 없는 임시저장시설의 경우, 지상 보관형의 평가된 이격거리는 14 m(최소농도), 33 m(최빈농도), 57 m(최대농도)이며, 반지하 보관형의 이격거리는 9 m(최소농도), 24 m(최빈농도), 45 m(최대농도), 지하보관형의 이격거리는 6 m(최소농도), 16 m(최빈농도), 31 m(최대농도)로 나타났다.