• 제목/요약/키워드: Software as a medical device

검색결과 75건 처리시간 0.024초

2023 Survey on User Experience of Artificial Intelligence Software in Radiology by the Korean Society of Radiology

  • Eui Jin Hwang;Ji Eun Park;Kyoung Doo Song;Dong Hyun Yang;Kyung Won Kim;June-Goo Lee;Jung Hyun Yoon;Kyunghwa Han;Dong Hyun Kim;Hwiyoung Kim;Chang Min Park;Radiology Imaging Network of Korea for Clinical Research (RINK-CR)
    • Korean Journal of Radiology
    • /
    • 제25권7호
    • /
    • pp.613-622
    • /
    • 2024
  • Objective: In Korea, radiology has been positioned towards the early adoption of artificial intelligence-based software as medical devices (AI-SaMDs); however, little is known about the current usage, implementation, and future needs of AI-SaMDs. We surveyed the current trends and expectations for AI-SaMDs among members of the Korean Society of Radiology (KSR). Materials and Methods: An anonymous and voluntary online survey was open to all KSR members between April 17 and May 15, 2023. The survey was focused on the experiences of using AI-SaMDs, patterns of usage, levels of satisfaction, and expectations regarding the use of AI-SaMDs, including the roles of the industry, government, and KSR regarding the clinical use of AI-SaMDs. Results: Among the 370 respondents (response rate: 7.7% [370/4792]; 340 board-certified radiologists; 210 from academic institutions), 60.3% (223/370) had experience using AI-SaMDs. The two most common use-case of AI-SaMDs among the respondents were lesion detection (82.1%, 183/223), lesion diagnosis/classification (55.2%, 123/223), with the target imaging modalities being plain radiography (62.3%, 139/223), CT (42.6%, 95/223), mammography (29.1%, 65/223), and MRI (28.7%, 64/223). Most users were satisfied with AI-SaMDs (67.6% [115/170, for improvement of patient management] to 85.1% [189/222, for performance]). Regarding the expansion of clinical applications, most respondents expressed a preference for AI-SaMDs to assist in detection/diagnosis (77.0%, 285/370) and to perform automated measurement/quantification (63.5%, 235/370). Most respondents indicated that future development of AI-SaMDs should focus on improving practice efficiency (81.9%, 303/370) and quality (71.4%, 264/370). Overall, 91.9% of the respondents (340/370) agreed that there is a need for education or guidelines driven by the KSR regarding the use of AI-SaMDs. Conclusion: The penetration rate of AI-SaMDs in clinical practice and the corresponding satisfaction levels were high among members of the KSR. Most AI-SaMDs have been used for lesion detection, diagnosis, and classification. Most respondents requested KSR-driven education or guidelines on the use of AI-SaMDs.

효과적인 암환자 관리를 위한 개인건강기록 관리 시스템 (Personal Health Record System for Efficient Monitoring of Cancer Therapy)

  • 송제민;서성보;신문선;한혜숙;박정석;류근호
    • 디지털융복합연구
    • /
    • 제14권12호
    • /
    • pp.65-72
    • /
    • 2016
  • 개인건강기록(PHR) 서비스는 기본적인 병원 진료 환경 외에 특수한 통원 치료 관리가 필요한 당뇨나 암환자 관리에 적절한 시스템이다. 본 논문에서는 항암화학요법 진행 중인 암 환자의 치료 과정에 맞춘 PHR 수집 및 분석 시스템을 개발하여 항암 치료 과정의 효율성을 효과적으로 향상할 수 있는 방법을 제안한다. 제안하는 암 PHR 서비스 플랫폼은 스마트 디바이스의 애플리케이션을 활용하여 항암화학요법 진행 중인 환자로부터 치료와 관련성이 가장 높은 통증 및 부작용 데이터를 입력 받고, 실제 병원에서 사용하는 의무 기록 형태로 정리한 통계 자료로 요약하여 의료진에게 제공한다. 의료 차트와의 연계에 적합한 형태로 제공되는 최종 분석 자료로 환자는 빠른 시간 내에 가장 적절한 처방을 받을 수 있다. 또한 통증 및 부작용 상태에 대한 정보를 의사에게 전할 수 있다. 의료진은 약물처방과 요양급여 등에 필요한 주요 객관적 자료들을 확보함으로 환자 진료의 질을 개선하는 효과가 있다.

감마선 검출기를 위한 스펙트럼 분석 소프트웨어 개발 (Development of a Spectrum Analysis Software for Multipurpose Gamma-ray Detectors)

  • 이종명;김용권;박길순;김정민;이기성;정진훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권1호
    • /
    • pp.51-59
    • /
    • 2010
  • NaI(Tl) 섬광 결정과 광전자 증배관를 결합한 형태의 감마선 검출기는 감도와 개발비용 면에서 우수하여 일반적으로 환경 감시용 검출기에 잘 활용된다. 본 연구에서는 보다 조작이 용이하고 다목적으로 활용할 수 있는 지능형 감마선 검출기와 연동되어 동위원소 자동인식이 가능한 분석 소프트웨어를 개발하였다. 개발된 소프트웨어는 크게 네트워크 인터페이스 모듈과 스펙트럼분석 모듈, 그리고 그래픽 유저 인터페이스 모듈의 세부분으로 나누어진다. 이중 핵심부분은 스펙트럼분석모듈로서 네트워크를 통해 수집된 신호로부터 해당 동위원소에 대한 에너지스펙트럼의 피크정보를 추출하고 이를 토대로 입력 동위원소의 종류를 판별해 내는 것이다. 일반적으로 채널과 에너지의 관계는 근사적으로 선형적인 함수관계가 있으므로 피크 정보를 정확히 얻어내면 해당 동위원소의 인식이 가능하다. 본 연구에서 개발된 피크 검출 알고리듬은 두 개의 피크를 가진 표준 동위원소에 대한 라이브러리 구축 및 이를 기준으로 한 미지의 동위원소에 대한 자동인식을 수행하도록 개발되었다. 대상 하드웨어인 뉴캐어메디컬시스템의 GammaPro 1410을 사용하여 연동 실험을 수행한 결과 하나의 미지의 선원에 대한 인식률을 측정할때 1% 이내의 피크 검출오차를 기록하였다. 또한 효율적인 네트워크 연동모듈의 설계를 통하여 세계 수준인 200K CPS의 데이터 처리속도를 달성하였다. 감마선 검출기와 본 소프트웨어에 더하여 선량분석 알고리듬에 대한 개발이 이어진다면 실시간 지능형 검출시스템으로서 의료기관 및 발전소, 연구시설 등 폭넓은 분야에 활용될 것으로 기대된다.

골반 방사선치료 시 소장의 위치변화를 위한 벨리보드의 유용성 (Effectiveness of Bellyboard Device for Displacement of Small Bowel in Pelvic Irradiation)

  • 이레나;이경자;서현숙
    • 한국의학물리학회지:의학물리
    • /
    • 제18권4호
    • /
    • pp.202-208
    • /
    • 2007
  • 골반 방사선치료 시 방사선조사부위에서 소장을 제외하여 방사선에 의한 소장의 독성 감소에 가장 효율적인 방법을 알아보기 위하여 본 연구가 시행되었다. 연구대상은 자궁경부암, 자궁내막암, 직장암, S-결장암과 난소암으로 수술 후 골반에 방사선치료를 받은 환자 14명이다. 환자는 모의치료를 시행하기 1시간 30분 전에 150 ml의 바륨과 방광을 채우기 위해 물 500 ml를 마시고 환자의 자세변화와 벨리보드 사용 유무에 따라 5종류의 조영촬영을 하였다. 첫 번째는 방광을 채운 후 누운 자세로 전 후면과 측면을 촬영한다. 두 번째는 방광을 채운 상태에서 엎드린 자세로, 세 번째는 방광을 비운 후 누운 자세로, 네 번째는 방광을 비운 후 엎드린 자세로, 다섯 번째는 방광을 비운 후 벨리보드를 사용하여 엎드린 자세로 각각의 전 후면과 측면을 촬영한다. 모든 조영촬영 사진에서 방사선조사부위에 포함되는 소장의 용적을 측정하였다. 결과는 방광을 채우거나 비운상태 모두 엎드린 자세가 누운 자세보다 소장의 용적이 감소되었으며 특히 측면사진에서 더욱 감소되었다. 엎드린 자세에서는 방광을 채운 상태의 소장 용적이 방광을 비운상태에 비해 전후면 사진에서 13%, 측면 사진에서 26%가 감소되었다. 방광을 비운 후 벨리보드를 사용한 상태의 소장 용적이 벨리보드를 사용하지 않고 엎드린 자세에 비해 전 후면에서 $62.8{\pm}27.1%$, 측면에서 $63{\pm}32.9%$가 감소되었다. 결론적으로 골반에 방사선치료를 시행할 경우 방광을 비운 후 벨리보드를 사용함으로써 소장의 용적을 최소화시킬 수 있었다.

  • PDF

다중 홀소자를 이용한 맥진기의 3차원 파형 획득 연구 (Achievement of 3-D Pulse Waves of Pulse Diagnostic Apparatus by using Multi-Hall Devices)

  • 최상대;김미선;안명천;최영근;김기왕;박달호;황도근;이상석
    • 한국자기학회지
    • /
    • 제16권4호
    • /
    • pp.216-220
    • /
    • 2006
  • 10개의 다중 홀(Hall)소자를 이용하여 요골동맥에 놓여진 영구자석의 위치 변화에 따른 전압의 변화를 전기적 신호로 얻었다.전기적 신호는 맥의 파형 신호를 의미하며 이들을 다시 회로의 하드웨어를 통해 신호들을 미분하여 자장의 변화 신호만 얻었다.소프트웨어를 통해 위치 변화에 따른 자장 변화의 크기에 따라 그 형태를 3차원 영상을 얻어 착용형 맥진기로서의 개발 가능성을 보여주었다.

Use of a gesture user interface as a touchless image navigation system in dental surgery: Case series report

  • Rosa, Guillermo M.;Elizondo, Maria L.
    • Imaging Science in Dentistry
    • /
    • 제44권2호
    • /
    • pp.155-160
    • /
    • 2014
  • Purpose: The purposes of this study were to develop a workstation computer that allowed intraoperative touchless control of diagnostic and surgical images by a surgeon, and to report the preliminary experience with the use of the system in a series of cases in which dental surgery was performed. Materials and Methods: A custom workstation with a new motion sensing input device (Leap Motion) was set up in order to use a natural user interface (NUI) to manipulate the imaging software by hand gestures. The system allowed intraoperative touchless control of the surgical images. Results: For the first time in the literature, an NUI system was used for a pilot study during 11 dental surgery procedures including tooth extractions, dental implant placements, and guided bone regeneration. No complications were reported. The system performed very well and was very useful. Conclusion: The proposed system fulfilled the objective of providing touchless access and control of the system of images and a three-dimensional surgical plan, thus allowing the maintenance of sterile conditions. The interaction between surgical staff, under sterile conditions, and computer equipment has been a key issue. The solution with an NUI with touchless control of the images seems to be closer to an ideal. The cost of the sensor system is quite low; this could facilitate its incorporation into the practice of routine dental surgery. This technology has enormous potential in dental surgery and other healthcare specialties.

Algorithm of Copulsation Estimation for Counterpulsation using Pressure of VAD Outlet Cannula

  • Kang Jung-Soo;Lee Jung-Joo;Jung Min-Woo;Park Yong-Doo;Sun Kyung
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권2호
    • /
    • pp.78-82
    • /
    • 2006
  • The ventricular assist device(VAD) helps to reduce the overload against the patient's native heart(NH). The pulsatile VAD pumps out the ventricular blood to the aorta with pulsatile flow. If the VAD pulsates simultaneously with the NH, the ventricle of the NH could confronts abnormally elevated aortic pressure, and this could deteriorate the ventricle rather than assist to recover it. Thus counterpulsation algorithms to avoid copulsation have been adopted by many VADs, but these methods utilize electrocardiography or arterial pressure signals, which may have difficulties to acquire consistently for a long period. In this study, the copulsation estimation algorithm for the counterpulsation is developed using the VAD outlet pressure signal. The VAD outlet pressure signal is good to maintain for a long time and the sensor part could be integrated to the VAD as a built-in module. From the VAD outlet pressure signal and its pump rate information calculated with Fast Fourier Transform, pulse peaks by the VAD and the NH were extracted and the next copulsation time at which the VAD and the NH would pulsate simultaneously was estimated. This estimation algorithm was implemented by using PC MATLAB software and tested for various pump rate conditions with mock circulation system. For each condition, the copulsation time was estimated successfully. Consequently, the results showed the possibility to use the outlet cannula pressure signal in the copulsation estimation.

CDMA-Based Ubiquitous $SaO_2$ Monitoring System for Oxygen Therapy Patients

  • Lee, Seung-Yup;Kang, Jae-Min;Shin, Il-Hyeung;Lee, Jae-Ho;Lee, Choon-Taek;Kim, Hee-Chan
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권5호
    • /
    • pp.274-281
    • /
    • 2006
  • In this paper, we propose a ubiquitous $SaO_2$ monitoring system for patients using oxygen therapy. For these patients, the ability to monitor oxygen saturation ubiquitously is very important fur accurate adjustment of ventilator's flow rate to match the patient's time-varying requirements with the shortest lag time possible. We have developed a portable device to measure $SaO_2$ and transmit it to hospital in real-time or in store-and-forward mode through the integration of $Bluetooth^{TM}$ technology and the code division multiple access (CDMA) cellular network. We also developed software for doctors to receive and manage the patients' $SaO_2$ information. Performance of the developed system was evaluated as acceptable by assessing the accuracy of the measured oxygen saturation value and the stability of communication network. Test results in real clinical setting demonstrate that our system is feasible for immediate use in home oxygen therapy.

이동 환자 생체신호의 실시간 전달을 위한 오버레이 네트워크 기반 자율군집형 미들웨어 플랫폼 (Self-Organizing Middleware Platform Based on Overlay Network for Real-Time Transmission of Mobile Patients Vital Signal Stream)

  • 강호영;정설영;안철수;박유진;강순주
    • 한국통신학회논문지
    • /
    • 제38C권7호
    • /
    • pp.630-642
    • /
    • 2013
  • 이동환자의 생체진단신호 원격전달을 위해서는 환자 및 감시자의 이동성, 환자의 이상징후 감지기능과 관련 컴퓨팅 자원들의 자율군집성 동작 서비스 바인딩 기능이 필수적으로 요구된다. 기존의 연구는 이동 환자 생체 신호 전달을 위해 중앙 집중화된 방식으로 중앙 서버 스스로 단일 고장점(Single Point of Failure)이 되어 서버가 다운되면 전체 시스템이 멈추게 되고, 지역적으로 일어나는 서비스에 대해 중앙으로 데이터 트래픽을 발생시킨다. 오버레이 네트워크 기반 자율군집형 미들웨어 플랫폼은 자율군집 메커니즘을 적용하여 구성한 유무선 이기종망 환경하의 오버레이 네트워크를 통해 관리 서버에 의한 중앙 또는 외부의 제어 없이 노드 간 협업에 의해 다양한 센서 장치(생체신호 측정 장비 포함)와 스마트폰, TV, PC 및 외부 시스템 간에 실시간 스트림 데이터를 송수신할 수 있도록 개발된 미들웨어 플랫폼이다. 생체신호 측정 장비로부터 발생한 여러 생체진단신호를 도처에 존재하는 자율군집형 분산 미들웨어 플랫폼인 SoSpR(Self-organizing Software-platform Router)로 관리 서버의 중재없이 자율적으로 실시간 전달 및 저장하고 동시에 복수개의 다양한 수신 단말에서 가까운 SoSpR로부터 실시간 수신 및 재생 시킬 수 있다.

PDA기반 인체동작 무선계측 (Wireless Measurement of Human Motion Based on PDA)

  • 이명호;김남진;이훈재;진계환;이삼열;이준행;이상복;이태수
    • 한국방사선학회논문지
    • /
    • 제1권1호
    • /
    • pp.39-44
    • /
    • 2007
  • 본 연구에서는 환자들의 일상생활 동안 움직임 이상을 관찰하기 위한 인체동작 무선계측 기술을 개발하였다. 기술개발에 사용한 도구는 버클리대학에서 개발한 MICA, TinyOS, nesC를 이용하여 무선신호 감지, 소프트웨어 플랫폼, 그리고 임베디드 프로그래밍을 위한 도구로 사용하였다. 실험을 위해 개발된 장비를 인체의 가슴부위에 부착하고 움직임 동작인 앉기, 서기, 눕기 데이터를 획득하여 PDA로 무선전송하여 저장하고 처리하여 그래프로 보여준다. 보여진 결과는 인체동작을 구속이나 제한 없이 기록할 수 있게 된다. 본 연구의 결과는 환자의 움직임 이상과 일상생활동작을 관찰하는 데 사용될 수 있을 것이다.

  • PDF