• Title/Summary/Keyword: Software as Medical Device

Search Result 84, Processing Time 0.024 seconds

Dosimetric Characteristic of Digital CCD Video Camera for Radiation Therapy

  • Young Woo. Vahc;Kim, Tae Hong.;Won Kyun. Chung;Ohyun Kwon;Park, Kyung Ran.;Lee, Yong Ha.
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.147-155
    • /
    • 2000
  • Patient dose verification is one of the most important parts in quality assurance of the treatment delivery for radiation therapy. The dose distributions may be meaningfully improved by modulating two dimensional intensity profile of the individual high energy radiation beams In this study, a new method is presented for the pre-treatment dosimetric verification of these two dimensional distributions of beam intensity by means of a charge coupled device video camera-based fluoroscopic device (henceforth called as CCD-VCFD) as a radiation detecter with a custom-made software for dose calculation from fluorescence signals. This system of dosimeter (CCD-VCFD) could reproduce three dimensional (3D) relative dose distribution from the digitized fluoroscopic signals for small (1.0$\times$1.0 cm$^2$ square, ø 1.0 cm circular ) and large (30$\times$30cm$^2$) field sizes used in intensity modulated radiation therapy (IMRT). For the small beam sizes of photon and electron, the calculations are performed In absolute beam fluence profiles which are usually used for calculation of the patient dose distribution. The good linearity with respect to the absorbed dose, independence of dose rate, and three dimensional profiles of small beams using the CCD-VCFD were demonstrated by relative measurements in high energy Photon (15 MV) and electron (9 MeV) beams. These measurements of beam profiles with CCD-VCFD show good agreement with those with other dosimeters such as utramicro-cylindrical (UC) ionization chamber and radiographic film. The study of the radiation dosimetric technique using CCD-VCFD may provide a fast and accurate pre-treatment verification tool for the small beam used in stereotactic radiosurgery (SRS) and can be used for verification of dose distribution from dynamic multi-leaf collimation system (DMLC).

  • PDF

A Bibliometric Analysis of Global Research Trends in Digital Therapeutics (디지털 치료기기의 글로벌 연구 동향에 대한 계량서지학적 분석)

  • Dae Jin Kim;Hyeon Su Kim;Byung Gwan Kim;Ki Chang Nam
    • Journal of Biomedical Engineering Research
    • /
    • v.45 no.4
    • /
    • pp.162-172
    • /
    • 2024
  • To analyse the overall research trends in digital therapeutics, this study conducted a quantitative bibliometric analysis of articles published in the last 10 years from 2014 to 2023. We extracted bibliographic information of studies related to digital therapeutics from the Web of Science (WOS) database and performed publication status, citation analysis and keyword analysis using R (version 4.3.1) and VOSviewer (version 1.6.18) software. A total of 1,114 articles were included in the study, and the annual publication growth rate for digital therapeutics was 66.1%, a very rapid increase. "health" is the most used keyword based on Keyword Plus, and "cognitive-behavioral therapy", "depression", "healthcare", "mental-health", "meta-analysis" and "randomized controlled-trial" are the research keywords that have driven the development and impact of digital therapeutic devices over the long term. A total of five clusters were observed in the co-occurrence network analysis, with new research keywords such as "artificial intelligence", "machine learning" and "regulation" being observed in recent years. In our analysis of research trends in digital therapeutics, keywords related to mental health, such as depression, anxiety, and disorder, were the top keywords by occurrences and total link strength. While many studies have shown the positive effects of digital therapeutics, low engagement and high dropout rates remain a concern, and much research is being done to evaluate and improve them. Future studies should expand the search terms to ensure the representativeness of the results.

Use of Respiratory Motion Reduction Device (RRD) in Treatment of Hepatoma (간암의 방사선치료 시 호흡운동 감소장치(respiratory motion reduction device, RRD)의 유용성에 관한 연구)

  • Lee Suk;Seong Jinsil;Kim Yong Bae;Cho Kwang Hwan;Kim Joo Ho;Jang Sae Kyung;Kwon Soo Il;Chu Sung Sil;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.19 no.4
    • /
    • pp.319-326
    • /
    • 2001
  • Purpose : Planning target volume (PTV) for tumors in abdomen or thorax includes enough margin for breathing-related movement of tumor volumes during treatment. Depending on the location of the tumor, the magnitude of PTV margin extends from 10 mm to 30 mm, which increases substantial volume of the irradiated normal tissue hence, resulting in increase of normal tissue complication probability (NTCP). We developed a simple and handy method which can reduce PTV margins in patients with liver tumors, respiratory motion reduction device (RRD). Materials and methods : For 10 liver cancer patients, the data of internal organ motion were obtained by examining the diaphragm motion under fluoroscope. It was tested for both supine and prone position. A RRD was made using MeV-Green and Styrofoam panels and then applied to the patients. By analyzing the diaphragm movement from patients with RRD, the magnitude of PTV margin was determined and dose volume histogram (DVH) was computed using AcQ-Plan, a treatment planning software. Dose to normal tissue between patients with RRD and without RRD was analyzed by comparing the fraction of the normal liver receiving to $50\%$ of the isocenter dose. DVH and NTCP for normal liver and adjacent organs were also evaluated. Results : When patients breathed freely, average movement of diaphragm was $12{\pm}1.9\;mm$ in prone position in contrast to $16{\pm}1.9\;mm$ in supine position. In prone position, difference in diaphragm movement with and without RRD was $3{\pm}0.9\;mm$ and 12 mm, respectively, showing that PTV margins could be reduced to as much as 9 mm. With RRD, volume of the irradiated normal liver reduced up to $22.7\%$ in DVH analysis. Conclusion : Internal organ motion due to breathing can be reduced using RRD, which is simple and easy to use in clinical setting. It can reduce the organ motion-related PTV margin, thereby decrease volume of the irradiated normal tissue.

  • PDF

Reimbursement of Digital Therapeutics: Future Perspectives in Korea

  • Jin Han Ju;Boram Sim;Jeongeun Lee;Jin Yong Lee
    • Korean Circulation Journal
    • /
    • v.52 no.4
    • /
    • pp.265-279
    • /
    • 2022
  • Digital health is rapidly growing worldwide and its area is expanding from wellness to treatment due to digital therapeutics (DTx). This study compared DTx in the Korean context with other countries to better understand its political and practical implications. DTx is generally the same internationally, often categorized as software as a medical device. It provides evidence-based therapeutic interventions for medical disabilities and diseases. Abroad, DTx support entailed state subsidies and fundraising and national health insurance coverage. In the case of national health insurance coverage, most cases were applied to mental diseases. Moreover, in Japan, DTx related to hypertension will possibly be under discussion for national health insurance coverage in 2022. In overseas countries, coverage was decided only when the clinical effects were equivalent to those provided by existing technology, and in the UK, real usage data for DTx and associated evaluations were reflected by national health coverage determination. Prices were either determined through closed negotiations with health insurance operating agencies and manufacturers or established based on existing technology. Concerning the current situation, DTx dealing with various diseases including hypertension are expected to be developed near in the future, and the demand for use and compensation will likely increase. Therefore, it is urgent to define and prepare for DTx, relevant support systems, and health insurance coverage listings. Several support systems must be considered, including government subsidies, science/technology funds, and health insurance.

Personal Health Record System for Efficient Monitoring of Cancer Therapy (효과적인 암환자 관리를 위한 개인건강기록 관리 시스템)

  • Song, Je-Min;Seo, Sung-Bo;Shin, Moon-Sun;Han, Hye-Sook;Park, Jeong-Seok;Ryu, Keun-Ho
    • Journal of Digital Convergence
    • /
    • v.14 no.12
    • /
    • pp.65-72
    • /
    • 2016
  • Personal Health Record(PHR) service can be helpful to patients with diseases requiring strict everyday care and medical treatment, such as diabetes or cancer. In this paper, we propose a PHR system specialized in collecting and analyzing health record data of cancer patients, and present the process of how the system can improve the efficiency of cancer treatment process. Through the smart device application, cancer PHR system obtains daily PHR data which is highly related and critical to cancer therapy. The analysis report is provided to the medical staff with an available format suited for Electronic Medical Record used at medical institution. With the final result of PHR analysis which is easily merged with medical chart, most efficient Chemotherapy treatment can be provided for the patients. Also it is possible for the patients to give the information of side-effect and other pain experience during therapy to their doctors without loss of information. The proposed PHR system has the effect of improving the quality of patient care by allowing the medical staff to acquire the main objective data necessary for drug prescription and medical care benefits.

Integrated Power Optimization with Battery Friendly Algorithm in Wireless Capsule Endoscopy

  • Mehmood, Tariq;Naeem, Nadeem;Parveen, Sajida
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.11
    • /
    • pp.338-344
    • /
    • 2021
  • The recently continuous enhancement and development in the biomedical side for the betterment of human life. The Wireless Body Area Networks is a significant tool for the current researcher to design and transfer data with greater data rates among the sensors and sensor nodes for biomedical applications. The core area for research in WBANs is power efficiency, battery-driven devices for health and medical, the Charging limitation is a major and serious problem for the WBANs.this research work is proposed to find out the optimal solution for battery-friendly technology. In this research we have addressed the solution to increasing the battery lifetime with variable data transmission rates from medical equipment as Wireless Endoscopy Capsules, this device will analyze a patient's inner body gastrointestinal tract by capturing images and visualization at the workstation. The second major issue is that the Wireless Endoscopy Capsule based systems are currently not used for clinical applications due to their low data rate as well as low resolution and limited battery lifetime, in case of these devices are more enhanced in these cases it will be the best solution for the medical applications. The main objective of this research is to power optimization by reducing the power consumption of the battery in the Wireless Endoscopy Capsule to make it battery-friendly. To overcome the problem we have proposed the algorithm for "Battery Friendly Algorithm" and we have compared the different frame rates of buffer sizes for Transmissions. The proposed Battery Friendly Algorithm is to send the images on average frame rate instead of transmitting the images on maximum or minimum frame rates. The proposed algorithm extends the battery lifetime in comparison with the previous baseline proposed algorithm as well as increased the battery lifetime of the capsule.

2023 Survey on User Experience of Artificial Intelligence Software in Radiology by the Korean Society of Radiology

  • Eui Jin Hwang;Ji Eun Park;Kyoung Doo Song;Dong Hyun Yang;Kyung Won Kim;June-Goo Lee;Jung Hyun Yoon;Kyunghwa Han;Dong Hyun Kim;Hwiyoung Kim;Chang Min Park;Radiology Imaging Network of Korea for Clinical Research (RINK-CR)
    • Korean Journal of Radiology
    • /
    • v.25 no.7
    • /
    • pp.613-622
    • /
    • 2024
  • Objective: In Korea, radiology has been positioned towards the early adoption of artificial intelligence-based software as medical devices (AI-SaMDs); however, little is known about the current usage, implementation, and future needs of AI-SaMDs. We surveyed the current trends and expectations for AI-SaMDs among members of the Korean Society of Radiology (KSR). Materials and Methods: An anonymous and voluntary online survey was open to all KSR members between April 17 and May 15, 2023. The survey was focused on the experiences of using AI-SaMDs, patterns of usage, levels of satisfaction, and expectations regarding the use of AI-SaMDs, including the roles of the industry, government, and KSR regarding the clinical use of AI-SaMDs. Results: Among the 370 respondents (response rate: 7.7% [370/4792]; 340 board-certified radiologists; 210 from academic institutions), 60.3% (223/370) had experience using AI-SaMDs. The two most common use-case of AI-SaMDs among the respondents were lesion detection (82.1%, 183/223), lesion diagnosis/classification (55.2%, 123/223), with the target imaging modalities being plain radiography (62.3%, 139/223), CT (42.6%, 95/223), mammography (29.1%, 65/223), and MRI (28.7%, 64/223). Most users were satisfied with AI-SaMDs (67.6% [115/170, for improvement of patient management] to 85.1% [189/222, for performance]). Regarding the expansion of clinical applications, most respondents expressed a preference for AI-SaMDs to assist in detection/diagnosis (77.0%, 285/370) and to perform automated measurement/quantification (63.5%, 235/370). Most respondents indicated that future development of AI-SaMDs should focus on improving practice efficiency (81.9%, 303/370) and quality (71.4%, 264/370). Overall, 91.9% of the respondents (340/370) agreed that there is a need for education or guidelines driven by the KSR regarding the use of AI-SaMDs. Conclusion: The penetration rate of AI-SaMDs in clinical practice and the corresponding satisfaction levels were high among members of the KSR. Most AI-SaMDs have been used for lesion detection, diagnosis, and classification. Most respondents requested KSR-driven education or guidelines on the use of AI-SaMDs.

Development of a Spectrum Analysis Software for Multipurpose Gamma-ray Detectors (감마선 검출기를 위한 스펙트럼 분석 소프트웨어 개발)

  • Lee, Jong-Myung;Kim, Young-Kwon;Park, Kil-Soon;Kim, Jung-Min;Lee, Ki-Sung;Joung, Jin-Hun
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.51-59
    • /
    • 2010
  • We developed an analysis software that automatically detects incoming isotopes for multi-purpose gamma-ray detectors. The software is divided into three major parts; Network Interface Module (NIM), Spectrum Analysis Module (SAM), and Graphic User Interface Module (GUIM). The main part is SAM that extracts peak information of energy spectrum from the collected data through network and identifies the isotopes by comparing the peaks with pre-calibrated libraries. The proposed peak detection algorithm was utilized to construct libraries of standard isotopes with two peaks and to identify the unknown isotope with the constructed libraries. We tested the software by using GammaPro1410 detector developed by NuCare Medical Systems. The results showed that NIM performed 200K counts per seconds and the most isotopes tested were correctly recognized within 1% error range when only a single unknown isotope was used for detection test. The software is expected to be used for radiation monitoring in various applications such as hospitals, power plants, and research facilities etc.

The nasoalveolar molding technique versus DynaCleft nasal elevator application in infants with unilateral cleft lip and palate

  • Abdallah Bahaa;Nada El-Bagoury;Noura Khaled;Sameera Mohamed;Ahmed Bahaa;Ahmed Mohamed Ibrahim;Khaled Mohamad Taha;Mohsena Ahmad Abdarrazik
    • Archives of Craniofacial Surgery
    • /
    • v.25 no.3
    • /
    • pp.123-132
    • /
    • 2024
  • Background: The introduction of presurgical nasoalveolar molding represented a significant departure from traditional molding methods. Developed by Grayson and colleagues in 1993, this technique combines an intraoral molding device with a nasal molding stent. This study aimed to compare the Grayson nasoalveolar molding appliance versus DynaCleft appliance as two methods of presurgical nasoalveolar molding. Methods: A single-blinded, randomized, parallel-arm clinical trial was conducted. Sixteen infants with complete unilateral cleft lip and palate were enrolled and divided into two groups of eight. Group 1 was treated with a modified Grayson nasoalveolar molding appliance that included a nasal stent, while group 2 was treated with DynaCleft elastic adhesive tape and an external nasal elevator. Standardized digital photographs of each infant were taken at baseline and post-treatment using a professional camera. Nine extraoral anthropometric measurements were obtained from each image using image measurement software. Results: The modified Grayson nasoalveolar appliance demonstrated a more significant improvement compared to DynaCleft in terms of alar length projection (on both sides), columella angle, and nasal tip projection. Symmetry ratios also showed enhancement, with significant improvements observed in nasal width, nasal basal width, and alar length projection (p< 0.05). Conclusion: Both the modified Grayson nasoalveolar appliance and DynaCleft appear to be effective presurgical infant orthopedics treatment options, demonstrating improvements in nasolabial aesthetics. The modified Grayson appliance, equipped with a nasal stent, improved nasal symmetry more effectively than DynaCleft, resulting in a straighter columella and a more medially positioned nasal tip.

Achievement of 3-D Pulse Waves of Pulse Diagnostic Apparatus by using Multi-Hall Devices (다중 홀소자를 이용한 맥진기의 3차원 파형 획득 연구)

  • Choi, S.D.;Kim, M.S.;Ahn, M.C.;Choi, Y.G.;Kim, G.W.;Park, D.H.;Hwang, D.G.;Lee, S.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.4
    • /
    • pp.216-220
    • /
    • 2006
  • The electric signals for the voltage as a function of distance between Hall devices and permanent magnets over the radial artery were investigated. The electric sgnals, that means signals of arterial pulse wave, were differentiated by the hardware of circuits and then were changed to differential signals as magnetic field. The 3-D images simulated by the software as function fo the intensity of differential signals were achieved. It shows that these system can apply to pulse diagnostic apparatus of porthble type medical instrument.