• Title/Summary/Keyword: Software V&V

Search Result 727, Processing Time 0.039 seconds

AC transport current loss analysis for a face-to-face stack of superconducting tapes

  • Yoo, Jaeun;Youm, Dojun;Oh, SangSoo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.2
    • /
    • pp.34-38
    • /
    • 2013
  • AC Losses for face to face stacks of four identical coated conductors (CCs) were numerically calculated using the H-formulation combined with the E-J power law and the Kim model. The motive sample was the face to face stack of four 2 mm-wide CC tapes with 2 ${\mu}m$ thick superconducting layer of which the critical current density, $J_c$, was $2.16{\times}10^6A/cm^2$ on IBAD-MgO template, which was suggested for the mitigation of ac loss as a round shaped wire by Korea Electrotechnology Research Institute. For the calculation the cross section of the stack was simply modeled as vertically aligned 4 rectangles of superconducting (SC) layers with $E=E_o(J(x,y,t)/J_c(B))^n$ in x-y plane where $E_o$ was $10^{-6}$ V/cm, $J_c$(B) was the field dependence of current density and n was 21. The field dependence of the critical current of the sample measured in four-probe method was employed for $J_c$(B) in the equation. The model was implemented in the finite element method program by commercial software. The ac loss properties for the stacks were compared with those of single 4 cm-wide SC layers with the same critical current density or the same critical current. The constraint for the simulation was imposed in two different ways that the total current of the stack obtained by integrating J(x,y,t) over the cross sections was the same as that of the applied transport current: one is that one fourth of the external current was enforced to flow through each SC. In this case, the ac loss values for the stacks were lower than those of single wide SC layer. This mitigation of the loss is attributed to the reduction of the normal component of the magnetic field near the SC layers due to the strong expulsion of the magnetic field by the enforced transport current. On the contrary, for the other case of no such enforcement, the ac loss values were greater than those of single 4cm-wide SC layer and. In this case, the phase difference of the current flowing through the inner and the outer SC layers of the stack was observed as the transport current was increased, which was a cause of the abrupt increase of ac loss for higher transport current.

Customizable Global Job Scheduler for Computational Grid (계산 그리드를 위한 커스터마이즈 가능한 글로벌 작업 스케줄러)

  • Hwang Sun-Tae;Heo Dae-Young
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.7
    • /
    • pp.370-379
    • /
    • 2006
  • Computational grid provides the environment which integrates v 따 ious computing resources. Grid environment is more complex and various than traditional computing environment, and consists of various resources where various software packages are installed in different platforms. For more efficient usage of computational grid, therefore, some kind of integration is required to manage grid resources more effectively. In this paper, a global scheduler is suggested, which integrates grid resources at meta level with applying various scheduling policies. The global scheduler consists of a mechanical part and three policies. The mechanical part mainly search user queues and resource queues to select appropriate job and computing resource. An algorithm for the mechanical part is defined and optimized. Three policies are user selecting policy, resource selecting policy, and executing policy. These can be defined newly and replaced with new one freely while operation of computational grid is temporarily holding. User selecting policy, for example, can be defined to select a certain user with higher priority than other users, resource selecting policy is for selecting the computing resource which is matched well with user's requirements, and executing policy is to overcome communication overheads on grid middleware. Finally, various algorithms for user selecting policy are defined only in terms of user fairness, and their performances are compared.

Design and Implementation of Wireless Device Management Agent based on OMA DM (OMA DM을 기반으로 한 무선이동통신 단말기 관리 에이전트 설계 및 구현)

  • Pak, Ju-Geon;Park, Kee-Hyun;Jang, Dae-Jin;Jang, Myung-Sook
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.4
    • /
    • pp.363-368
    • /
    • 2008
  • Mobile devices become more complex and harder to manage due to the advance of technologies. In this paper, we designed and implemented the DM Agent based on OMA(Open Mobile Alliance) DM(Device Management) which is a standard for mobile device management. The proposed DM Agent basically can manage parameter configuration through the commands ADD, DELETE, REPLACE and GET currently. Each module of the agent was designed and implemented separately for additional functions such as error reporting and software management. So the additional functions can be added by modifying Adaptor part which processes the management commands instead of modifying other modules which analyze or generate management commands. The DM Agent proposed in this paper is implemented based on WIPI(Wireless Internet Platform for Interoperability), therefore portability of the agent can be improved. In addition, this research can give a development example for dissenminating OMA DM as well as verify functional compatibility of WIPI platform. SK WIPI SDK and a Funambol DM test server are used to test operations of the implemented DM Agent.

Effect of Stopping Drinking, Using Alcoholic Liver Disease Questionnaire, DSOM and SF-36 (알코올성 간질환 변증 설문, DSOM, SF-36을 이용한 알코올성 간질환 환자의 금주 효과 연구)

  • Lee, Jae-Wang;Hong, Sang-Hoon;Park, Sang-Eun;Son, Ho-Young;Kim, Do-Gyoung;Lee, Seung-Yeon;Lee, Su-Young;Kim, Bo-Kyoung;Kang, Chang-Wan;Lee, In-Sun
    • The Journal of Internal Korean Medicine
    • /
    • v.31 no.2
    • /
    • pp.356-364
    • /
    • 2010
  • Objectives : This study was done to evaluate the effect of stopping drinking, using alcoholic liver disease questionnaire, Diagnosis System of Oriental Medicine (DSOM) and Health Related Quality of Life (HRQOL). Methods : 49 men who satisfied the requirement participated in this trial. They stopped drinking for 6 weeks. They were analyzed using DSOM, alcoholic liver disease questionnaire and SF-36. The data were classified by age (<47,$\geq$48) and alcoholic intake per day (<100g,$\geq$100g). For HRQOL, the SF-36v2 Health Survey was used and Quality Metric Health Outcomes Scoring Software 2.0 (QualityMetric, Lincoln, RI, USA) was applied for the analysis. Results : The alcoholic liver disease questionnaire had a partial correlation with DSOM. Generally stopping drinking decreased Heat (熱). Especially in the group drinking over 100g per day, the correlation was high. In the group over 48 years old, spleen (脾) was improved comparatively. In the group with low HRQOL (PCS<31.43, MCS<23.33) deficiency (虛) was improved. Conclusions : We found that stopping drinking can improve pathogenic factors of alcoholic liver disease and the alcoholic liver disease questionnaire be a useful diagnostic method on alcoholic liver disease by comparison with DSOM.

CT Number Measurement of Residual Foreign Bodies in Face (안면부에 잔류된 다양한 이물질을 측정한 CT 계수)

  • Wee, Syeo Young;Choi, Hwan Jun;Kim, Mi Sun;Choi, Chang Yong
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.423-430
    • /
    • 2008
  • Purpose: Computed tomography theoretically should improve detection of foreign bodies and provide more information of adjacent soft tissues. And the CT scanner and PACS program proved to be an excellent instrument for detection and localization of most facial foreign bodies above certain minimum levels of detectability. The severity of injury in penetrating trauma to the face, it is often underestimated by physical examination. Diagnosis of a retained foreign object is always critical. Methods: From March, 2005 to February 2008 a study was done with 200 patients who had facial trauma. Axial and coronal CT images were obtained with a General Electric(Milwaukee, Wis) 9800 CT scanner at 130 kV, 90 mA, with a 2-mm section thickness and a $512{\times}512$ matrix. Results: Axial and coronal CT images at various window widths should be used as the first imaging modality to detect facial foreign bodies. The attenuation coefficients for the metallic and nonmetallic foreign bodies ranged from -437 to +3071 HU. As a general rule, metallic foreign bodies produced more Hounsfield artifacts than nonmetallic foreign bodies, thus providing a clue to their composition. All of the metallic foreign bodies were represented by a single peak and had a maximum attenuation coefficient of +3071 HU. Of the nonmetallic foreign bodies, glass had an attenuation coefficient that ranged from +105 to +2039, while plastic had a much lower coefficient that ranged from -62 to -35. wood had the lowest range of attenuation coefficients: -491 to -437. Conclusion: The PACS program allows one to distinguish metallic from nonmetallic foreign bodies and to individually identify the specific composition of many nonmetallic foreign bodies. This program does not, however, allow identification of the specific composition of a metallic foreign body. We recommend this type of software program for CT scanning of any patient with an injury to the face in which a foreign body is suspected.

The Comparative Kinematic Analysis of a Volleyball Spike Serve (배구 스파이크 서브 동작의 운동학적 비교 분석)

  • Park, Jong-Chul;Back, Jin-Ho;Lee, Jin-Taek
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.4
    • /
    • pp.671-680
    • /
    • 2009
  • We performed a study to obtain kinematic data on the characteristics of spike serving techniques used by volleyball players, including other basic data that will be useful for in-field applications. We used three-dimensional videography to compare good tough serves and serve errors. The subjects were 3 left attackers whose spike serves were videographed (60 fileds/s). The three-dimensional coordinates were calculated using the direct linear transformation method and then analyzed using the Kwon 3D software program version 3.1. There was no difference in time elapsed. However, the vertical displacement of the center of body mass(CM) differed between the 2 types of serves: in successful serves, the CM tended to be lower, as did the maximum ball height at the time of hitting. Further, the higher the level of the hitting hand was at the moment of impact, the higher was the likelihood of scoring points. In good serves, the players tended to accelerate their CM movement just before jumping to hit the ball and descend rapidly at the moment of hitting. The hand speed along with ball velocity during the impact was proven to be higher in successful serves. Moreover, in successful serves, the shoulder angles increased to a greater extent while the elbow angles were maintained constant. This possibly resulted in faster and more precise serves. An important observation was that the angle of trunk inclination during the jump did not increase with the swing of the shoulders, muscle tendon complex.

Development of Thermoluminescence and Optical Stimulated Luminescence Measurements System (열자극발광 및 광자극발광 측정장치의 개발)

  • Park, Chang-Young;Chung, Ki-Soo;Lee, Jong-Duk;Chang, In-Su;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.46-54
    • /
    • 2015
  • The thermoluminescence (TL) and optically stimulated luminescence (OSL) are commonly used to measure and record the expose of individuals to ionization radiation. Design and performance test results of a newly developed TL and OSL measurement system are presented in this paper. For this purpose, the temperature of the TL material can be controlled precisely in the range of $1{\sim}1.5^{\circ}C$ by using high-frequency (35 kHz) heating system. This high-frequency power supply was made of transformer with ferrite core. For optical stimulation, we have completed an optimal combination of the filters with the arrangement of GG420 filter for filtering the stimulating light source and a UG11 filter at the detecting window (PMT). By using a high luminance blue LED (Luxeon V), sufficient luminous intensity could be obtained for optical stimulation. By using various control boards, the TL/OSL reader device was successfully interfaced with a personal computer. A software based on LabView program (National Instruments, Inc.) was also developed to control the TL/OSL reader system. In this study, a multi-functional TL/OSL dosimeter was developed and the performance testing of the system was carried out to confirm its reliability and reproducibility.

Intracameral Epinephrine Injection after Phacoemulsification on Pupil Dilation during Phacovitrectomy for Proliferative Diabetic Retinopathy (유리체절제술과 수정체유화술 동시 수술 시 백내장수술 후 앞방내 에피네프린 주입과 동공 확대)

  • Kim, Sangbum;Park, Jongyeop;Shin, Jaeryung;Lee, Seungwoo
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1137-1141
    • /
    • 2018
  • Purpose: We explored the mydriatic effects of injected intracameral epinephrine after phacoemulsification (PE) combined with phacovitrectomy to treat proliferative diabetic retinopathy (PDR). Methods: We enrolled 96 patients (96 eyes) who underwent phacovitrectomy to treat PDR; we used ImageJ software to measure pupil sizes and the ratios of pupil to cornea area (PCA) before and after PE and after pars plana vitrectomy (PPV). We compared pupil sizes between those who received intracameral epinephrine (0.001% w/v) after PE but before PPV (study group, 46 eyes) and patients not so treated (control group, 50 eyes). Results: The PCA ratios of the study group were $0.52{\pm}0.11$ before PE, $0.43{\pm}0.12$ after PE, and $0.51{\pm}0.11$ after PPV, respectively. Changes in pupil size were significant (p < 0.001, p < 0.001 respectively). The PCA ratios of the control group were $0.52{\pm}0.10$ before PE, $0.39{\pm}0.15$ after PE, and $0.43{\pm}0.15$ after PPV, respectively. Changes in pupil size after PE were significant (p = 0.011) but the change after PPV was not (p = 0.056). Conclusions: Intracameral epinephrine given after PE but before PPV effectively dilates the pupils during phacovitrectomy to treat PDR.

Application of single-step genomic evaluation using social genetic effect model for growth in pig

  • Hong, Joon Ki;Kim, Young Sin;Cho, Kyu Ho;Lee, Deuk Hwan;Min, Ye Jin;Cho, Eun Seok
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.12
    • /
    • pp.1836-1843
    • /
    • 2019
  • Objective: Social genetic effects (SGE) are an important genetic component for growth, group productivity, and welfare in pigs. The present study was conducted to evaluate i) the feasibility of the single-step genomic best linear unbiased prediction (ssGBLUP) approach with the inclusion of SGE in the model in pigs, and ii) the changes in the contribution of heritable SGE to the phenotypic variance with different scaling ${\omega}$ constants for genomic relationships. Methods: The dataset included performance tested growth rate records (average daily gain) from 13,166 and 21,762 pigs Landrace (LR) and Yorkshire (YS), respectively. A total of 1,041 (LR) and 964 (YS) pigs were genotyped using the Illumina PorcineSNP60 v2 BeadChip panel. With the BLUPF90 software package, genetic parameters were estimated using a modified animal model for competitive traits. Giving a fixed weight to pedigree relationships (${\tau}:1$), several weights (${\omega}_{xx}$, 0.1 to 1.0; with a 0.1 interval) were scaled with the genomic relationship for best model fit with Akaike information criterion (AIC). Results: The genetic variances and total heritability estimates ($T^2$) were mostly higher with ssGBLUP than in the pedigree-based analysis. The model AIC value increased with any level of ${\omega}$ other than 0.6 and 0.5 in LR and YS, respectively, indicating the worse fit of those models. The theoretical accuracies of direct and social breeding value were increased by decreasing ${\omega}$ in both breeds, indicating the better accuracy of ${\omega}_{0.1}$ models. Therefore, the optimal values of ${\omega}$ to minimize AIC and to increase theoretical accuracy were 0.6 in LR and 0.5 in YS. Conclusion: In conclusion, single-step ssGBLUP model fitting SGE showed significant improvement in accuracy compared with the pedigree-based analysis method; therefore, it could be implemented in a pig population for genomic selection based on SGE, especially in South Korean populations, with appropriate further adjustment of tuning parameters for relationship matrices.

Simulation study on effects of loading rate on uniaxial compression failure of composite rock-coal layer

  • Chen, Shao J.;Yin, Da W.;Jiang, N.;Wang, F.;Guo, Wei J.
    • Geomechanics and Engineering
    • /
    • v.17 no.4
    • /
    • pp.333-342
    • /
    • 2019
  • Geological dynamic hazards during coal mining can be caused by the failure of a composite system consisting of roof rock and coal layers, subject to different loading rates due to different advancing velocities in the working face. In this paper, the uniaxial compression test simulations on the composite rock-coal layers were performed using $PFC^{2D}$ software and especially the effects of loading rate on the stress-strain behavior, strength characteristics and crack nucleation, propagation and coalescence in a composite layer were analyzed. In addition, considering the composite layer, the mechanisms for the advanced bore decompression in coal to prevent the geological dynamic hazards at a rapid advancing velocity of working face were explored. The uniaxial compressive strength and peak strain are found to increase with the increase of loading rate. After post-peak point, the stress-strain curve shows a steep stepped drop at a low loading rate, while the stress-strain curve exhibits a slowly progressive decrease at a high loading rate. The cracking mainly occurs within coal, and no apparent cracking is observed for rock. While at a high loading rate, the rock near the bedding plane is damaged by rapid crack propagation in coal. The cracking pattern is not a single shear zone, but exhibits as two simultaneously propagating shear zones in a "X" shape. Following this, the coal breaks into many pieces and the fragment size and number increase with loading rate. Whereas a low loading rate promotes the development of tensile crack, the failure pattern shows a V-shaped hybrid shear and tensile failure. The shear failure becomes dominant with an increasing loading rate. Meanwhile, with the increase of loading rate, the width of the main shear failure zone increases. Moreover, the advanced bore decompression changes the physical property and energy accumulation conditions of the composite layer, which increases the strain energy dissipation, and the occurrence possibility of geological dynamic hazards is reduced at a rapid advancing velocity of working face.