• Title/Summary/Keyword: Software Reliability Measurement

Search Result 155, Processing Time 0.032 seconds

A Comparison Study between Uniform Testing Effort and Weibull Testing Effort during Software Development (소프트웨어 개발시 일정테스트노력과 웨이불 테스트 노력의 비교 연구)

  • 최규식;장원석;김종기
    • Journal of Information Technology Application
    • /
    • v.3 no.3
    • /
    • pp.91-106
    • /
    • 2001
  • We propose a software-reliability growth model incoporating the amount of uniform and Weibull testing efforts during the software testing phase in this paper. The time-dependent behavior of testing effort is described by uniform and Weibull curves. Assuming that the error detection rate to the amount of testing effort spent during the testing phase is proportional to the current error content, the model is formulated by a nonhomogeneous Poisson process. Using this model the method the data analysis for software reliability measurement is developed. The optimum release time is determined by considering how the initial reliability R($\chi$ 0) would be. The conditions are ($R\chi$ 0)>$R_{o}$ , $P_{o}$ >R($\chi$ 0)> $R_{o}$ $^{d}$ and R($\chi$ 0)<$R_{o}$ $^{d}$ for uniform testing efforts. deal case is $P_{o}$ >($R\chi$ 0)> $R_{o}$ $^{d}$ Likewise, it is ($R\chi$ 0)$\geq$$R_{o}$ , $R_{o}$ >($R\chi$ 0)>R(eqation omitted) and ($R\chi$ 0)<R(eqation omitted)for Weibull testing efforts. Ideal case is $R_{o}$ > R($\chi$ 0)> R(eqation omitted).

  • PDF

An experimental study on the oriented mechanical properties of aluminum micro thin foil material (알루미늄 마이크로 박판소재의 방향성에 관한 실험적 연구)

  • Lee H. J.;Lee N. K.;Choi S.;Lee H. W.;Choi T. H.;Hwang J. H.;Kwag D. G.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.10a
    • /
    • pp.295-298
    • /
    • 2005
  • This paper is concerned with the precision material property measurement of a micro metal thin foil that is used in MEMS technology. Since these MEMS components require great precision and accuracy, evaluation of reliability such as the lift cycle endurance test, impact test, and residual stress test is necessary for these components. However, in practice, real reliability tests are not easy to perform due to consideration of various factors. Rather than actual testing, it would be much easier to evaluate the reliability of components by the analytical approach. Although the analytical method is utilized by software tools, it is obviously necessary to acquire fundamental properties of materials through real test methods. In this paper, the oriented mechanical properties of aluminum thin foil are measured by nano scale material property measurement system.

  • PDF

Strategies for Continuous Transactions with Customers for B2B Software Retailers: Case Study (B2B 소프트웨어 유통 중소기업을 위한 고객과의 지속거래 유지 전략: 사례 연구)

  • Choi, Yong-Jun;Kim, Wan-Ki
    • Journal of Distribution Science
    • /
    • v.16 no.12
    • /
    • pp.81-93
    • /
    • 2018
  • Purpose - The purpose of this study was to propose a specific and empirical continuous transaction strategy through service quality of improvement to small and medium Korean companies whose main business is B2B distribution and sale of general-purpose SW. Research design, data, and methodology - The research procedure is largely divided into two phases. In the first phase, the service quality, the customer satisfaction, and the continuous transaction research hypothesis and the verification are carried out. Experimental data were collected from 450 companies, CEO companies of SMEs innovation institutes, and 510 companies from medium and large enterprises. From September 15 to October 5, 2015, 215 questionnaires were used. And research hypothesis and test were conducted by SPSS SW Ver. 20. Results - The results of the study confirm that service quality has a positive effect on customer satisfaction and continuous transaction: as the detailed items for improving the service quality, 'responsiveness', 'assurance' and 'empathy' have been adopted. Therefore, there are critical factors of a company's survival through continuous transaction. Conclusions - Through this study, we confirmed that the survival of small businesses require continuous improvement in service quality. Among the factors improving service quality, empathy means service satisfaction of customers; so, it is necessary to continuously improve it by evaluating customer satisfaction. Responsiveness means rapid response to customer needs and reliability; it is necessary to enhance customer responsiveness by continuous job training and service training. Finally, assurance is the same as sales product or after service. This means that it is necessary to not only issue the "supply contract," but also improve the reliability of the sales product by securing the competence of the consulting professional. However, because the service quality measurement factors selected in this study are the measurement factors that are mainly applied to large companies or those in the service industries, it is important to consider the type of sales of software distribution companies.

Comparison of Angle Measurements on Hallux Valgus with Two Different Methods Using Digital Images (디지털 영상을 이용한 무지 외반증 변형각 측정에서 서로 다른 두 계측 방법의 비교)

  • Sung, Il-Hoon;Kim, Ki Chun;Sung, Chang-Ho;Seo, Woo-Young;Lee, Doo-Yeon;Cho, Young A
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.1
    • /
    • pp.40-44
    • /
    • 2013
  • Purpose: To study inter- and intra-observer reliabilities of computerized measurements of the angular parameters of hallux valgus deformity, using two different kinds of software tools for angle measurement on the digital radiography. Materials and Methods: On 35 digital radiographies of standing foot anteroposterior view of hallux valgus, two observers (A, B) independently measured hallux valgus angle (HVA) and 1-2 intermetatarsal angle ($IMA_{1-2}$) twice, using two methods. In method I, an angle was determined from duplicated lines to longitudinal axes made for bisecting line on the target bones with software tool. In method II, an angle was calculated automatically and directly from bisecting lines (longitudinal axes) made on the target bones. We compared two methods using paired t-test to determine significance of differences. Inter- and intraobserver reliabilities were evaluated using the intraclass correlation coefficients (ICC). Results: There were no significant differences between measurements of method I and II for each observer (p>0.05) and intraobserver reliability were good. (ICC>0.9) Inter-observer reliability for method I and II was good of the HVA (ICCs, 0.912 and 0.905) and moderate of the $IMA_{1-2}$ (ICCs, 0.505 and 0.537). There were interobserver differences in HVA of method I and II. Conclusion: No significant difference was found statistically between measurements of method I and II. Both methods I and II would be acceptable to measure angular parameters of hallux valgus deformity.

Dental hygienist's knowledge measurement tool for emergency treatment related to systemic disease (치과위생사의 전신질환과 관련된 응급처치 지식 측정도구 개발)

  • Yoon, Yong-Ha;Lee, Jung-Hwa;Noh, Hie-Jin;Han, Sun-Young;Mun, So-Jung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.22 no.2
    • /
    • pp.133-142
    • /
    • 2022
  • Objectives: This study was conducted by clinical dentistry hygienists to develop knowledge measurement tools and evaluate knowledge necessary to cope with emergencies related to systemic diseases occurring in dentistry. Methods: Basic questions were developed on the six most frequently occurring diseases in the dental office: diabetes, syncope, respiratory disease, coronary artery disease, cerebrovascular disease, and epilepsy. Fifty-eight preliminary questions were composed in a survey format through expert validation. The survey was then conducted on 290 dental hygienists to verify the composition validity and reliability. Factor and reliability analyses were performed using the SPSS 23.0 program, and the correct answer rate for each question was calculated. Results: 49 items of a total of 13 factors were adopted as the final items for signs, symptoms, prevention and treatment of five diseases. The question with the highest percentage of correct answers for each question was "Slowly set up the unit chair when raising the patient"(97.9%) during the prevention of unconsciousness and question with the lowest correct answer rate was "soft substances such as cloth should be put in the mouth to prevent trauma while the seizure persists" (16.6%). Conclusions: A total of 49 questions have been developed as tools to measure the knowledge of dental hygienists' first aid related to systemic diseases and it is expected that related curriculum can be operated or evaluated by using them.

Development of a system for measuring inside & outside diameters of automobile hub (자동차 허브 내.외경 측정 시스템 개발)

  • 윤규택;이동주;최만용;박혜원;박정학]
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.363-368
    • /
    • 2002
  • An automobile hub is composed of a hollow cylindrical part with inner and outer diameters. These hub diameters must be precise, as any irregularities in them (diameters) can influence/degrade the motion of an automobile with this problem. Highly accurate and reliable hub inner and outer diameters measurement systems are therefore required for inspection of the diameters. In this research, an automobile hub inner and outer diameters measurement system has been developed and tested. The system consists of measuring heads with LVDT sensors, and associated software for automatic measurement and calibration of the diameters and the sensors respectively. The system has been evaluated in comparison with an existing measurement system, and the following outcomes have been achieved; .Improved and guaranteed quality and reliability .Increased productivity and cost reduction. These results prove the system developed in this research to be suitable for automobile hub inspection.

  • PDF

Characteristics and Fault Analysis of Electric Devices for High-Speed Railway using Control Signal (제어 신호를 이용한 고속철도 전장품의 특성 및 고장 분석)

  • Han, Young-Jae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.12
    • /
    • pp.1128-1133
    • /
    • 2006
  • The most important thing to secure safety and reliability of railway vehicles is to verify performance characteristics of equipments, and related companies or research institutes had many efforts to verify performances and functions of equipments synthetically and efficiently. KHST(Korean High Speed Train) has been developed by KRRI (Korea Railroad Research Institute). An electric railway system is composed of high-tech subsystems, among which main electric equipment such as transformers and converter are critical components determining the performance of rolling stock. We developed a measurement system for on-line test and evaluation of performances of KHST. The measurement system is composed of software part and hardware part. Perfect interface between multi-users is possible. A new method to measure temperature was applied to the ]measurement system. By using the system, fault diagnosis and performance evaluation of electric equipment in Korean High Speed Train was conducted during test running.

Optimal WAMS Configuration in Nordic Power System

  • Mohamed A.M. Hassan;Omar H. Abdalla;Hady H. Fayek;Aisha H.A. Hashim;Siti Fauziah Toha
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.3
    • /
    • pp.130-138
    • /
    • 2023
  • The Smart grids are considered as multi-disciplinary power systems where the communication networks are highly employed. This paper presents optimal wide area measurement system (WAMS) configuration in Nordic power system. The transition from SCADA to WAMS becomes now trend in all power systems to ensure higher reliability and data visibility. The optimization applied in this research considered the geographical regions of the Nordic power system. The research considered all the devices of WAMS namely phasor measurement units (PMUs), phasor data concentrators (PDCs) and communication links. The study also presents two scenarios for optimal WAMS namely base case and N-1 contingency as different operating conditions. The result of this research presents technical and financial results for WAMS configuration in a real power system. The optimization results are performed using MATLAB 2017a software application.

Software Metric for CBSE Model

  • Iyyappan. M;Sultan Ahmad;Shoney Sebastian;Jabeen Nazeer;A.E.M. Eljialy
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.12
    • /
    • pp.187-193
    • /
    • 2023
  • Large software systems are being produced with a noticeably higher level of quality with component-based software engineering (CBSE), which places a strong emphasis on breaking down engineered systems into logical or functional components with clearly defined interfaces for inter-component communication. The component-based software engineering is applicable for the commercial products of open-source software. Software metrics play a major role in application development which improves the quantitative measurement of analyzing, scheduling, and reiterating the software module. This methodology will provide an improved result in the process, of better quality and higher usage of software development. The major concern is about the software complexity which is focused on the development and deployment of software. Software metrics will provide an accurate result of software quality, risk, reliability, functionality, and reusability of the component. The proposed metrics are used to assess many aspects of the process, including efficiency, reusability, product interaction, and process complexity. The details description of the various software quality metrics that may be found in the literature on software engineering. In this study, it is explored the advantages and disadvantages of the various software metrics. The topic of component-based software engineering is discussed in this paper along with metrics for software quality, object-oriented metrics, and improved performance.

Reliability Study of Three-Dimensional Motion Analysis Program for Wrist and Finger Joint Range of Motion Measurement (손목 · 손가락 관절가동범위 측정에 관한 3차원 동작분석 프로그램의 신뢰도 연구)

  • Park, Sun Ha;Park, Ji-Hyuk;Kim, Jong Bae;Jung, Young Jin;Lee, Joo Hyun;Park, Hae Yean
    • Therapeutic Science for Rehabilitation
    • /
    • v.12 no.1
    • /
    • pp.79-92
    • /
    • 2023
  • Objective : This study aimed to assess the reliability of a three-dimensional (3D) motion analysis program for measuring the range of motion (ROM) of wrist and finger joints. Methods : The study recruited 50 people who had no restrictions on wrist and finger movements, understood the purpose of this study, and agreed to participate. Using a goniometer and a 3D motion analysis program, a total of 11 wrist and finger ROM were measured once each. To measure the reliability of the 3D motion analysis program, the degree of agreement and inconsistency of the measured values were compared. Results : Analysis of the degree of agreement of the measured values revealed that 38 out of 44 items showed a very high degree of agreement. Regarding analysis of inconsistency in the measured values, inconsistencies were found in three items. Conclusion : The results of this study confirmed that the ROM of the joint could be measured using the 3D motion analysis program applied in this study. In addition, it might be expected that the 3D motion analysis program would be used in various clinical fields owing to the advantages of measurement convenience and accuracy.