• 제목/요약/키워드: Soft-tissue conditioning

검색결과 9건 처리시간 0.025초

임시 연성 의치상 이장재의 충격 흡수에 관한 연구 (SHOCK-ABSORBING BEHAVIOR OF TEMPORARY SOFT DENTURE LINERS)

  • 천용석;조인호
    • 대한치과보철학회지
    • /
    • 제34권1호
    • /
    • pp.151-167
    • /
    • 1996
  • Temporary soft liners can be used to prevent chronic soreness from dentures or to aid in its treatment are as adjuncts in tissue conditioning, for temporary obturators, and to stabilize baseplate or surgical stent. The purpose of this study was to evaluate the shock absorption properties of several temporary soft denture liners using a free drop test with an accelerometer. The materials tested inclued Coe-comfort, Softone, Tissue conditioner and Viscogel. The specimens were fabricated with the thickness of 1, 2, 3mm and were stored in distilled water at $37^{\circ}C$ for a day, 1, 2, and 3 weeks. Six samples were made with each material for each test condition and the shock-absorbing behavior was evaluated according to material, thickness and duration. The results were as following : 1. Softone of 3mm thickness stored for a day showed the most excellent shock absorbability. 2. The shock absorbing behavior of duration according to materials and thickness showed a day to be the highest and decreased in 1 week, 2 weeks and 3 weeks in that order(p<0.05). And there was no significant difference between durations in Tissue conditioner. 3. The shock absorbability of thickness according to materials and duration showed 3mm to be highest and decreased in the order of 2mm, 1mm(p<0.05). 4. In comparison of the shock absorbability of temporary soft denture liners according to thickness, there was statistically significant difference between Softone and Visocgel, Tissue conditioner, Coe-comfort / Viscogel and Tissue conditioner, Coe-comfort in 1,2mm thickness, and between Softone, Viscogel and Tissue conditioner, Coe-comfort in 3mm thickness (p<0.05).

  • PDF

A STUDY ON THE ADHESION OF A SOFT LINER CONTAINING 4-META TO THE BASE METAL ALLOY AND ITS VISCOELASTIC PROPERTY

  • Park Hyun-Joo;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제41권6호
    • /
    • pp.732-746
    • /
    • 2003
  • Statement of problem. Soft lining materials, also referred to as tissue conditioning materials, tissue heating materials, relining materials, soft liners or tissue conditioners, were first introduced to dentistry by a plastic manufacturer in 1959. Since the introduction of the materials to the dental field, their material properties have been continually improved through the effort of many researchers. Soft lining materials have become widely accepted, particularly by prosthodontists, because of their numerous clinical advantages and ease of manipulation. Unfortunately, few reports have been issued upon the topic of increasing the bond strength between the base metal alloy used in cast denture bases and PMMA soft liner modified with 4-META, nor upon the pattern of debonding and material change in wet environment like a intra oral situation. Purpose. The purposes of this study were comparing the bond strength between base metal alloy used for the cast denture bases and PMMA soft liner modified with 4-META, and describing the pattern of debonding and material property change in wet environment like the intraoral situation. Material and Methods. This study consisted of four experiments: 1. The in vitro measurement of shear bond strength of the adhesive soft liner. 2. The in vitro measurement of shear bond strength of the adhesive soft liner after 2 weeks of aging. 3. A comparison of debonding patterns. 4. An evaluation the Relation time of modified soft liner. The soft liner used in this study was commercially available as Coe-soft (GC America.IL.,USA), which is provided in forms of powder and liquid. This is a PMMA soft liner commonly used in dental clinics. The metal primer used in this study was 4-META containing primer packed in Meta fast denture base resin (Sun Medical Co., Osaka, Japan). The specimens were formed in a single lap joint desist which is useful for evaluating the apparent shear bond strength of adhesively bonded metal plate by tensile loading. Using the $20{\times}20mm$ transparent grid, percent area of adhesive soft liner remaining on the shear area was calculated to classify the debonding patterns. To evaluate the change of the initial flow of the modified adhesive soft liner, the gelation time was measured with an oscillating rheometer (Haake RS150W/ TC50, Haake Co., Germany). It was a stress control and parallel plate type with the diameter of 35mm. Conclusion. Within the conditions and limitations of this study, the following conclusions were drawn as follows. 1. There was significant increase of bond strength in the 5% 4-META, 10% 4-META containing groups and in the primer coated groups versus the control group(P<0.05). 2. After 2 weeks of aging, no significant increase in bond strength was found except for the group containing 10% 4-META (P<0.05). 3. The gelation times of the modified soft liner were 9.3 minutes for the 5% 4-META containing liner and 11.5 minutes for the 10% 4-META liner. 4. The debonding patterns of the 4-META containing group after 2 weeks of aging were similar to those of immediaely after preparation, but the debonding pattern of the primer group showed more adhesive failure after 2 weeks of aging.

치료적 방법을 연부조직 손상단계에 따라 사용하기 위한 지침에 관한 연구 (Study on Guidelines for Using Therapeutic Modalities According to Injury Phases of Soft Tissue)

  • 권원안;김식현;전경희
    • The Journal of Korean Physical Therapy
    • /
    • 제12권3호
    • /
    • pp.497-507
    • /
    • 2000
  • This study was performed to understanding on guidelines for using therapeutic modalities according to injury phases of soft tissue. Clinical decisions on how and when therapeutic modalities may be used should be based on recognition of signs and symptoms. as well as some awareness of the time frames associated with the various phases of the Healing process. The physical therapist must have a sound understanding of that process in terms of the sequence of the various process of healing stage. The results of this study are as follows: 1. Once an acute injury has occured, the healing process consists of the imflammatory response phase, the fibroblastic-repair phase, and the maturation-remodeling phase and can impede by various pathologic factors. 2. Modality use in the initial acute injury phase and the inflammatory response phase should be directed toward limiting the amount of swelling and reducing pain. 3. Modality use in the Fibroblastic repair phase may be change from cold to heat. The purpose of heat is to increase circulation to the injured area to promote healing. 4. During the Maturation-Remodeling phase, some type of heating modalities, ultrasound, or short wave and microwave diathermy should be used to increase circulation to the deeper tissue. In this phases, physical therapists must control training and conditioning habits to allow the injury to heal sufficiently.

  • PDF

All-ceramic versus titanium-based implant supported restorations: Preliminary 12-months results from a randomized controlled trial

  • Weigl, Paul;Trimpou, Georgia;Grizas, Eleftherios;Hess, Pablo;Nentwig, Georg-Hubertus;Lauer, Hans-Christoph;Lorenz, Jonas
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권1호
    • /
    • pp.48-54
    • /
    • 2019
  • PURPOSE. The aim of the present randomized controlled study was to compare prefabricated all-ceramic, anatomically shaped healing abutments followed by all-ceramic abutments and all-ceramic crowns and prefabricated standard-shaped (round-diameter) titanium healing abutments followed by final titanium abutments restored with porcelain-fused-to-metal (PFM) implant crowns in the premolar and molar regions. MATERIALS AND METHODS. Forty-two patients received single implants restored either by all-ceramic restorations (test group, healing abutment, final abutment, and crown all made of zirconia) or conventional titanium-based restorations. Immediately after prosthetic incorporation and after 12 months of loading, implant survival, technical complications, bone loss, sulcus fluid flow rate (SFFR) as well as plaque index (PI) and implant stability (Periotest) were analyzed clinically and radiologically. RESULTS. After 12 months of loading, an implant and prosthetic survival rate of 100% was observed. Minor prosthetic complications such as chipping of ceramic veneering occurred in both groups. No statistical significant differences were observed between both groups with only a minimum of bone loss, SFFR, and PI. CONCLUSION. All-ceramic implant prostheses including a prefabricated anatomically shaped healing abutment achieved comparable results to titanium-based restorations in the posterior region. However, observational results indicate a benefit as shaping the peri-implant soft-tissue with successive provisional devices and subsequent compression of the soft tissue can be avoided.

구연산, 테트라싸이클린, 섬유소 전색제로 처리된 상아질면에 대한 결체조직의 조기부착 (EARLY CONNECTIVE TISSUE ATTACHMENT ON DENTIN SURFACE TREATED WITH CITRIC ACID, TETRACYCLINE AND FIBRIN SEALANTS)

  • 이혜자;한수부;고재승
    • Journal of Periodontal and Implant Science
    • /
    • 제23권2호
    • /
    • pp.283-299
    • /
    • 1993
  • The purpose of this study was to observe early connective tissue attachment on dentin surface treated with citric acid, tetracycline, and fibrin sealants and compare their conditioning effects on dentin surface. Experimental dentin blocks conditioned with citric acid, tetracycline or fibrin sealant, and only root planned control block were surgically implanted in the pouch under buccal mucoperiosteal flaps of left mandible, right maxilla, left maxilla, right mandible of 18 male rabbits. Rabbits were sacrificed after 1 and 6 hours, 1, 3, 7 and 14 days after implantation and then specimens including dentin block and surrounding soft tissue were obtained, and prepared for light and transmission electron microscopic examination. 1 and 6 hours after dentin block implantation, there was plasma proteins adsorption followed by fibrin clot formation and no differences among specimens. At the 1-day observation interval, delicate fibrin network was observed in the all groups, and there were proliferative fibroblasts, angiogenesis and macrophage in the all 3-day specimens. Cellular aggregates and abundant connective tissue adhered dentin surface and tetracycline or citric acid treated group showed much proliferative fibroblast and abundant collagen fibers at 1 week. But at 2 week, citric acid treated group showed much proliferative fibroblast and abundant collagen fibers. These observations suggested that new connective tissue attachment to dentin was initiated by the adsorption of plasma proteins to the dentin surface and followed by fibrin clot formation. Tetracycline and citric acid seemed to make dentin surface more biologically favorable for the connective tissue attachment.

  • PDF

치근파절로 변위된 상악 중절치의 디지털을 이용한 즉시 임플란트 식립 및 심미 수복 증례 (Digital immediate implantation and aesthetic immediate loading on maxillary incisor displaced due to root fracture: a case report)

  • 송지은;박송이;박찬;윤귀덕;임현필;박상원
    • 구강회복응용과학지
    • /
    • 제39권4호
    • /
    • pp.267-275
    • /
    • 2023
  • 디지털 자료를 이용한 진단 및 즉시 임플란트 식립, 그리고 보철 수복 방법은 전통적인 방법에 비하여 비교적 간단한 자료 채득을 통해 치료 과정을 간소화하고 정확도를 개선하며 데이터의 다양한 활용이 가능하다는 장점이 있다. 임플란트 즉시 식립 시 더 나은 심미적 결과를 얻기 위해서는 발치와의 치유 중에 임플란트 주변 연조직을 개선해야 한다. 이를 위하여 임시 보철물의 즉시 수복을 통해 출현윤곽의 형태를 적절하게 유도할 수 있으며, 향후 최종 수복시에 좋은 임상결과를 얻을 수 있어 환자 만족도가 높다. 본 증례는 상악 좌우 중절치에 외상 후 수평 치근파절이 발생함에 따라 심미성과 치조골 상태를 고려한 발치 후 임플란트 즉시 식립 및 부하를 계획하였다. 디지털 구강 스캐너를 이용한 인상 채득을 통해 외상 치아에 외력을 가하지 않으면서 보다 심미적인 보철물의 제작을 위한 디지털 진단 왁스업을 시행하였으며, 이를 토대로 이상적인 식립 위치를 결정하고 3D 프린팅 수술용 가이드를 이용한 임플란트 즉시 식립을 시행하였다. 식립 5일 후 임시 보철물을 수복하였으며, 3개월 동안 임시 보철물의 형태를 이용한 연조직 개선 및 형태 유도 과정을 거쳐 최종 지르코니아 보철물 수복하였다.

치석제거 및 치근활택술 시에 테트라싸이클린 젤의 국소적 도포 (TOPICAL APPLICATION OF TETRACYCLINE GEL IN SCALING AND ROOT PLANING)

  • 한수부;이재일;허정미;장미경;심창구;이철우
    • Journal of Periodontal and Implant Science
    • /
    • 제23권3호
    • /
    • pp.647-658
    • /
    • 1993
  • The purpose of this study is to examine the influence of 5% tetracycline(Tc) gel on healing of gingival tissue and change of diseased root surface when used with nonsurgical procedure. 7 patients with advanced periodontitis were received thorough scaling and root planning, followed by saline irrigation on 10 randomly selected control teeth and Tc gel application for 5 minutes with specifically designed plastic instrument of 10 test teeth in contralateral side. At 0, 1, 7, 14, and 21 days after treatment, biopsy and extraction were carried out. At day 7, Tc group showed decreased inflammation and delayed proliferation of pocket epithelium in comparison with control group which was continued for all experimental days. Scanning electron microscopic finding revealed demineralized and cleaned root surface with exposed dentinal tubules in Tc gel group. In the present study, clinically successful result is expected with combined use of nonsurgical periodontal therapy and intrapocket application of Tc gel.

  • PDF

THE EFFECTS OF SURFACE CONTAMINATION ON THE SHEAR BOND STRENGTH OF COMPOMER

  • Heo, Jeong-Moo;Lee, Su-Jong;Im, Mi-Kyung
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.577-577
    • /
    • 2001
  • The lastest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not blown dry but left moist before application of the bonding primer. Ideally, the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during preparation of a restoration. The aim of this study was to evaluate the effect of contamination by hem-ostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were cleaned from soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive paper on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows: Group 1 : Dentin surface was not etched and not contaminated by hemostatic agents. Group2 : Dentin surface was not etched but was contaminated by Astringedent (Ultradent product Inc., Utah, U.S.A.). Group3 : Dentin surface was not etched but was contaminated by Bosmin (Jeil Phann, Korea.). Group4 : Dentin surface was not etched but was contaminated by Epri-dent (Epr Industries, NJ, U.S.A.). Group5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6 : Dentin surface was etched and contaminated by Astringedent. Group7 : Dentin surface was etched and contaminated by Bosmin. Group8 : Dentin surface was etched and contaminated by Epri-dent. Group9 : Dentin surface was contaminated by Astringedent. The contaminated surface was rinsed by water and dried by compressed air. Group10 : Dentin surface was contaminated by Bosmin. The contaminated surface was rinsed by water aud dried by compresfed air. Group 11 : Dentin surface was contaminated by Epri-dent. The contaminated surface was rinsed by water and dried by compresfed air. After surface conditioning, F2000 was applicated on the conditoned dentin surface. The teeth were thermocycled in distilled water at $5^{\circ}C\;and\;55^{\circ}C$ for 1000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the lmife-edge shearing rod of the Universal testing machine(Zwick 020, Germany) running at a cross head speed of 1.0mmimin. There were no significant differences in shear bond strength between groups 1 and group 3 and 4, but group 2 showed significant decrease in shear bond strength compared with group 1. There were no significant differences in shear bond strength between group 5 and group 7 and 8, but group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

  • PDF

지혈제 오염이 콤포머의 전단결합강도에 미치는 영향 (THE EFFECTS OF SURFACE CONTAMINATION BY HEMOSTATIC AGENTS ON THE SHEAR BOND STRENGTH OF COMPOMER)

  • 허정무;곽주석;이황;이수종;임미경
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.150-157
    • /
    • 2002
  • One of the latest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not dry but left moist before application of the bonding primer Ideally the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically, contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during cavity preparation. The aim of this study was to evaluate the effect of contamination by hemostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were removed soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive papers on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows : Group 1: Dentin surface was not etched and not contaminated by hemostatic agents. Group 2: Dentin surface was not etched but was contaminated by Astringedent$^{\circledR}$(Ultradent product Inc., Utah, U.S.A.) Group 3: Dentin surface was not etched but was contaminated by Bosmin$^{\circledR}$(Jeil Pharm, Korea.). Group 4: Dentin surface was not etched but was contaminated by Epri-dent$^{\circledR}$(Epr Industries, NJ, U.S.A.). Group 5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6: Dentin sorface was etched and contaminated by Astringedent$^{\circledR}$. Group 7 : Dentin surface was etched and contaminated by Bosmin$^{\circledR}$. Group 8: Dentin surface was etched and contaminated by Epri-dent$^{\circledR}$. Group 9: Dentin surface was contaminated by Astringedent$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. Group 10: Dentin surface was contaminated by Bosmin$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. Group 11 : Dentin surface was contaminated by Epri-dent$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. After surface conditioning, F2000$^{\circledR}$ was applicated on the conditoned dentin surface The teeth were thermocycled in distilled water at 5$^{\circ}C$ and 55$^{\circ}C$ for 1,000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the knife-edge shearing rod of the Universal Testing Machine(Zwick Z020, Zwick Co., Germany) running at a cross head speed or 1.0 mm/min. Group 2 showed significant decrease in shear bond strength compared with group 1 and group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.