• Title/Summary/Keyword: Soft-finger tip

Search Result 17, Processing Time 0.03 seconds

Finger Tip Replantation (수지 첨부 절단의 재접합술)

  • Kong, Byeong-Seon;Kim, Yong-Jin
    • Archives of Reconstructive Microsurgery
    • /
    • v.12 no.2
    • /
    • pp.105-111
    • /
    • 2003
  • It has been known that the vessels of the finger tip are very small and have many branches, so the anastomosis of this vessel is very difficult. But when this operation achieves success, the replanted finger tip provides adequate soft tissue, restoration of the length, sensory and nail. The authors describe the result of finger tip replantation in 94 patients, 103 finger tips, from October 1999 to June 2002. We performed the salvage procedure in all cases. The success rate of finger tip replantation was 74.8%. We achieved higher success rate, when we succeeded anastomosis of the central artery. The function of the replanted fingers was good. The average TAM was 80% and patient satisfaction was high. We be live that we can achieve higher success rate by anastomosing central artery and performing delicate salvage procedure.

  • PDF

Review Article Fingertip Replantation (수지첨부 접합수술)

  • Hahn, Hyun Oun
    • Archives of Reconstructive Microsurgery
    • /
    • v.20 no.2
    • /
    • pp.132-138
    • /
    • 2011
  • Although finger tip replantation is popularized nowadays, it is not easy operations even for experienced surgeons. The indication for replantation to treat fingetip amputation is still controversial, but I think replantation for function and cosmetic absolute indication. This paper will discuss about methods of fingertip replantation and unexpected complications on soft tissue after operation.

  • PDF

Research of Controlled Motion of Dual Fingers with Soft-Tips Grasping (Soft-Tip을 가진 Dual Finger의 파지운동제어에 관한 연구)

  • 박경택;양순용;한현용
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.670-673
    • /
    • 2000
  • This paper attempt analysis and computer simulation of dynamics of a set of dual multi-joint fingers with soft-deformable tips which are grasping. Firstly, a set of differential equation describing dynamics of the fingers and object together with geometric constraint of tight area-contacts is formulated by Euler-Lagrange's formalism. Secondly, problems of controlling both the internal force and the rotation angle of the grasped object under the constraints of area-contacts of tight area-contacts are discussed. The effect of geometric constraints of area-contacts on motion of the overall system is analyzed and a method of computer simulation for overall system of differential-algebraic equations is presented. Finally, simulation results are shown and the effects of geometric constraints of area-contact is discussed.

  • PDF

Neurovascular Island Graft for Finger Tip Loss (도서형 신경 혈관 피판을 이용한 수지의 피부 및 연부조직 결손의 재건술)

  • Chung, Duke-Whan;Han, Chung-Soo;Kim, Ki-Bong
    • Archives of Reconstructive Microsurgery
    • /
    • v.10 no.2
    • /
    • pp.99-104
    • /
    • 2001
  • Purpose : Loss of sensibility over the finger tip resents a grave deficit and is an indication for sensible soft tissue reconstruction. This paper was performed to assess the long term results obtained by nerovascular island flap. Material and Methods : We performed neurovascular island graft for defective sensibility of finger tip loss in 94 cases since 1979 to 2000. The recipient sites were the thumb pulp defect in 79 cases, the amputated thumb in 9 cases, the amputated index in 4 cases, and the velar aspect of interphalangeal joint of thumb in 2 cases. The donor flaps were obtained from the radial side of ring finger in 63 cases, the ulnar side of the ring finger in 21 cases, and the ulnar side of the middle finger in 10 cases. A mean follow-up period was 5.7 years. Results : The flap quality was well vascularized and survived in 89 cases. The two-point discrimination was average 8.7mm. Because of scar contracture, the range of motion of the donor finger was decreased 3.5% of the normal finger in the distal interphalangeal joint, 8,2% in the proximal interphalangeal joint. A phenomenon of double sensibility occurred in 66 cases. Conclusion : This technique was excellent both aesthetically and functionally as a reconstruction of the Loss of fingertip.

  • PDF

Bilateral Free 2ndToe Pulp Flap for Reconstruction of Soft Tissue Defect in Traumatic Finger Injuries

  • Oh, Jeongseok;Eun, Seok Chan
    • Journal of Trauma and Injury
    • /
    • v.32 no.3
    • /
    • pp.181-186
    • /
    • 2019
  • Finger reconstruction involves paramount significance of both functional and aesthetic aspects, due to its great impact on quality of life. The options range from primary closure, skin grafts, local flaps, pedicled flaps, and free flaps. The optimal method should consider various circumstances of the patient and surgeon. We would like to report a case of a young woman who initially presented with cellulitis and necrosis of the left second finger-tip who underwent reconstruction with bilateral toe pulp free flap. The patient could successfully return to her job that involves keyboard typing and playing the piano, with acceptable donor site morbidity.

Reconstruction of Distal Phalangeal Soft Tissue Defects with Reverse Homodigital Artery Island Flap

  • Kim, Byung-Gook;Han, Soo-Hong;Lee, Ho-Jae;Lee, Soo-Hyun
    • Archives of Reconstructive Microsurgery
    • /
    • v.23 no.2
    • /
    • pp.65-69
    • /
    • 2014
  • Purpose: Soft tissue reconstruction is essential for recovery of finger function and aesthetics in any traumatic defect. The authors applied a reverse homodigital artery island flap for soft tissue defect on distal part of digits. The aim of this study is to evaluate the efficacy of the procedure. Materials and Methods: Seven cases of soft tissue defects of finger tip were included in this study. There were six male and one female, mean age was 43 years and mean follow-up period was 38 months. The length of flaps ranged from 2.0 to 2.5 cm and width ranged from 1.0 to 2.0 cm. Flap survival, postoperative complications were evaluated. Results: All flaps survived without loss. Donor sites were repaired with primary closure in five cases and skin graft in two cases. None of the patients showed significant complications and their average finger motion was $255^{\circ}$ in total active motion at the last follow-up. Conclusion: The authors suggest that the reverse homodigital artery island flap could be a versatile treatment option for the soft tissue defect on distal part of digits.

Development of a 16 DOF Anthropomorphic Robot Hand with Back-Drivability Joint for Stable Grasping (안정 파지를 위한 16자유도 역구동 관절을 가지는 인간형 로봇 손 개발)

  • Yang, Hyun-Dae;Park, Sung-Woo;Park, Jae-Han;Bae, Ji-Hun;Baeg, Moon-Hong
    • The Journal of Korea Robotics Society
    • /
    • v.6 no.3
    • /
    • pp.220-229
    • /
    • 2011
  • This paper focuses on a development of an anthropomorphic robot hand. Human hand is able to dexterously grasp and manipulate various objects with not accurate and sufficient, but inaccurate and scarce information of target objects. In order to realize the ability of human hand, we develop a robot hand and introduce a control scheme for stable grasping by using only kinematic information. The developed anthropomorphic robot hand, KITECH Hand, has one thumb and three fingers. Each of them has 4 DOF and a soft hemispherical finger tip for flexible opposition and rolling on object surfaces. In addition to a thumb and finger, it has a palm module composed the non-slip pad to prevent slip phenomena between the object and palm. The introduced control scheme is a quitely simple based on the principle of virtual work, which consists of transposed Jacobian, joint angular position, and velocity obtained by joint angle measurements. During interaction between the robot hand and an object, the developed robot hand shows compliant grasping motions by the back-drivable characteristics of equipped actuator modules. To validate the feasibility of the developed robot hand and introduced control scheme, collective experiments are carried out with the developed robot hand, KITECH Hand.

A Study on Control of Stable Grasping Motion for Finger Robot (손가락 로봇의 안정 파지 운동 제어에 관한 연구)

  • Choi, Jong-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.3
    • /
    • pp.428-437
    • /
    • 2006
  • This paper attempts to derive and analyze the dynamic system of grasping a rigid object by means of two multi-degrees-of-freedom robot flngers with soft and deformable tips. It is shown firstly that a set of differential equation describing dynamics system of the manipulators and object together with geometric constraint of tight area-contacts is formulated by Lagrange's equation. It is shown secondly that the problems of controlling both the forces of pressing object and the rotation angle of the object under the geometric constraints are discussed. In this paper. the control method for dynamic stable grasping and enhancing dexterity in manipulating things is proposed. It is illustrated by computer simulation that the control system gives the performance improvement in the dynamic stable grasping of the dual fingers robot with soft tips.

Soft Tissue Reconstruction of Finger and Hand Using Arterialized Venous Free Flap (동맥화 정맥 유리 피판술을 이용한 수부와 수지 연부조직 결손의 재건)

  • Kong, Byeong-Seon;Kim, Yong-Jin;Cho, Kwang-Woo
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.2
    • /
    • pp.107-116
    • /
    • 2004
  • Flaps are necessary, when important structures such as bone, tendon, nerve and vessel are exposed. Arterialized venous free flap is suited to the coverage of finger and hand because the thickness of venous flap is thin. Authors performed 65 cases arterialized venous free flap for the soft tissue reconstruction of the hand and finger. The size of donor defect were from $1{\times}1cm\;to\;7{\times}12cm$. The mean flap area was $9.1cm^2$. The recipient sites were finger tip in 34 cases, finger shaft in 29 cases and hand in 2 cases. The donor sites were volar aspect of distal forearm in 40 cases, thenar area in 17 cases and foot dorsum in 6 cases. The types of arterialized venous free flap were A-A type in 4 cases and A-V type in 61 cases. The length of afferent vein was from 0.5 cm to 3 cm (mean 1.7 cm) and efferent vein was from 1 cm to 10 cm (mean 2.2 cm). 58 flaps(89.2%) survived eventually. 42 flaps(64.6%) survived totally without any complication. 8 flaps(12.3%) showed the partial necrosis but they were healed without any additional operations. 8 flaps (12.3%) showed the partial necrosis requiring the additional skin graft. We had a satisfactory result by using arterialized venous free flap for the soft tissue reconstruction of finger and hand. We believe that volar aspect of distal forearm, thenar area, foot dorsum are suited as a donor site and the short length of the flap pedicle, the strong arterail inflow affect the survival rate of arterialized venous free flaps.

  • PDF

A Study on Stable Grasping Motion Control of Dual-Finger (듀얼-핑거의 안정적 파지 운동 제어에 관한 연구)

  • Um Hyuk;Choi Jong-Hwan;Kim Seung-Soo;Han Hyun-Yong;Yang Soon-Yong;Lee Jin-Gul
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.4
    • /
    • pp.81-88
    • /
    • 2005
  • This paper attempts to derive the dynamic model of handling tasks in finger robot which grasps stable and manipulates a rigid object with some dexterity. Firstly, a set of differential equation describing dynamics of the manipulators and object together with geometric constraint of tight area-contacts is formulated by Lagrange's equation. Secondly, the roblems of controlling both the forces of pressing object and the rotation angle of the object under the geometric constraints are discussed. The effect of geometric constraints of area-contacts between the link's end-effector and the object is analyzed and the model based on the differential-algebraic equations is presented. In this paper, the control method for dynamic stable grasping and enhancing dexterity in manipulating things is proposed. It is illustrated by computer simulation and the experiment that the control system gives the performance improvement in the dynamic stable grasping and nimble manipulating of the dual fingers robot with soft tips.