• Title/Summary/Keyword: Soft tissue reconstruction

Search Result 510, Processing Time 0.027 seconds

Versatility of the Distally-Based Sural Artery Fasciocutaneous Flap on the Lower Leg and Foot in Patients with Chronic Disease

  • Park, Jin-Su;Roh, Si-Gyun;Lee, Nae-Ho;Yang, Kyoung-Moo
    • Archives of Plastic Surgery
    • /
    • v.40 no.3
    • /
    • pp.220-225
    • /
    • 2013
  • Background A recent advancement in microsurgery, the free flap is widely used in the reconstruction of the lower leg and foot. The simple and effective methods of local flaps, including transposition and advancement flaps, have been considered for patients with chronic debilitation who are unable to endure long surgical procedures or general anesthesia. However, the location and size of the wound may restrict the clinical application of a local flap. Under these circumstances, a sural flap can be an excellent alternative, rendering satisfying clinical outcomes in chronically debilitated patients. Methods Between 2008 and 2012, 39 patients underwent soft tissue defect treatment by sural artery flap as a final method. All of the patients had at least one chronic disease or more (diabetes, hypertension, vascular disease, etc.). Also, all of the patients had a history of chronic lower extremity ulceration, which revealed no response to several months of conservative treatment. Results The results of the 39 cases had a success rate of 100% with 39 complete recoveries. Nine cases suffered complications: partial necrosis (n=4), wound dehiscence without necrosis (n=3), hematoma (n=1), and infection (n=1). Conclusions The sural artery flap is not only useful for the lower leg but also for the heel, and other various parts. Furthermore, it is a relatively simple surgical technique for reconstructing the defect area for patients with various chronic conditions with a high surgical risk or contraindications to surgery.

Polyurethane Foam Template for Simple Design of Digital Island Flap (폴리우레탄 폼 드레싱재료를 이용한 간단한 손가락 섬피판 디자인)

  • Kim, Nam-Joong;Choi, Hwan-Jun;Kim, Jun-Hyuk
    • Archives of Reconstructive Microsurgery
    • /
    • v.18 no.1
    • /
    • pp.35-39
    • /
    • 2009
  • Purpose: Various techniques have been attempted for design of the flaps. However, there are some disadvantages. They have thin, pliable, and two dimensional methods. The aim of this study is to report usefulness of polyurethane foam dressing materials for three dimensional design of the digital island flap. Methods: From June of 2007 to september of 2008, 10 patients received digital island flap surgery for soft tissue defect of the finger. After minimal debridement of the wound, size and shape of the defect were measured using polyurethane foam. We used Medifoam-$5^{(R)}$ And then, designed this inset the wound. The flap was designed on the donor site with a arterial pedicle as the central axis according to size and shape. A full thickness skin graft from the groin is applied on the flap donor defect and secured with a tieover bolster dressing. Results: Reviewing sizes of the flaps, the length and width of flaps ranged from 1.5 to 3.3 cm and 1.0 to 2.5 cm. The PACS(Picture Archiving Communication System) program allows identification of the donor depth of finger. The distance for the soft tissue ranged from 4.3 mm to 6.7 mm. Mean depth of donor site was 5.3${\pm}$0.6 mm. Also, the thickness of Medifoam-$5^{(R)}$ ranged nearly 5 mm. On flap insetting, full-thickness skin graft was necessary. We did not experience any problems in the recipient site size either, regardless of the extended flaps. Conclusion: Polyurethane foam has many advantages over the more conventional templates. Refinements in flap design and surgical technique resulted in favorable functional and cosmetic results. Especially, for beginner, Polyurethane foam dressing material is a simple and safe tool and therefore is an excellent choice for design of the island flap.

  • PDF

Analysis of prognostic factors affecting poor outcomes in 41 cases of Fournier gangrene

  • Hahn, Hyung Min;Jeong, Kwang Sik;Park, Dong Ha;Park, Myong Chul;Lee, Il Jae
    • Annals of Surgical Treatment and Research
    • /
    • v.95 no.6
    • /
    • pp.324-332
    • /
    • 2018
  • Purpose: We present our experience involving the management of this disease, identifying prognostic factors affecting treatment outcomes. Methods: The patients treated for Fournier gangrene at our institution were retrospectively reviewed. Data collected included demographics, extent of soft tissue necrosis, predisposing factors, etiological factors, laboratory values, and treatment outcomes. The severity index and score were calculated. Multivariate regression analysis was used to determine the association between potential predictors and clinical outcomes. Results: A total of 41 patients (male:female = 33:8) were studied. The mean age was 54.4 years (range, 24-79 years). The most common predisposing factor was diabetes mellitus (n = 19, 46.3%). Sixteen patients (39.0%) were current smokers. Seven patients had chronic kidney disease. The most frequent etiology was urogenital lesion (41.5%). The mortality rate was 22.0% (n = 9). Multivariate regression analyses showed that extension of necrosis beyond perineal/inguinal area and pre-existing chronic kidney disease were significant and independent predictors of mortality. Extension of necrosis beyond perineal/inguinal area was a significant predictor of increased duration in the intensive care unit and hospital stay. In addition, pre-existing chronic kidney disease was a significant predictor of flap reconstruction in the wound. Conclusion: Fournier gangrene with extensive soft tissue necrosis and pre-existing chronic kidney disease was associated with poor prognosis and complexity of patient management. Early recognition of dissemination and premorbid renal function is essential to reduce mortality and establish a management plan for this disease.

Surgical Management of Comminuted Midshaft Clavicle Fractures Using Reconstruction Plate and Circumferential Wiring: Does the Circumferential Wiring Interfere with the Bone Union? (쇄골 간부 복합 골절에서 재건 금속판 및 환 강선을 이용한 수술적 치료: 환 강선이 골 유합을 방해하는가?)

  • Kim, Kyung-Tae;Shin, Chung-Shik;Park, Young-Chul;Kim, Dong-hyun;Kim, Min-Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.245-252
    • /
    • 2021
  • Purpose: This study examined the radiological and clinical outcomes of internal fixation using a reconstruction plate and 21G circumferential wire in comminuted midshaft clavicular fractures. Materials and Methods: A retrospective cohort study was performed on 51 patients between 2005 and 2019. Thirty-two patients underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and 19 patients underwent surgery without a wire. The patients were assessed with the radiographic parameters, the University of California at Los Angeles (UCLA) score, and the visual analogue scale (VAS) pain score. Based on this, patients who operated without a circumferential wire were set as the control group, and the differences in bone union between the two groups were compared. Results: Thirty-two patients were followed-up for an average of 65 weeks, and 19 patients in the control group were followed-up for an average of 56 weeks. The radiological evaluation confirmed the anatomical reduction and bone union in all 32 patients. No case of nonunion was present. The UCLA score was 32.38 on average and 33.11 in the control group (p=0.395). The VAS score was 1.00 on average and 0.84 in the control group (p=0.668). A significant difference in the bony union time was observed between the group who underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and the control group (p=0.015). On the other hand, there was no statistical significance when other variables were controlled (p=0.107). Conclusion: For displaced midshaft clavicular fractures, internal fixation using a reconstruction plate and 21G circumferential wire maintained accurate anatomical reduction. The satisfactory clinical and radiological results mean that internal fixation using a reconstruction plate and 21G circumferential wire may be a good option for surgical treatment.

Elbow Reconstruction Using Island Flap for Burn Patients

  • Hur, Gi Yeun;Song, Woo Jin;Lee, Jong Wook;Lee, Hoon Bum;Jung, Sung Won;Koh, Jang Hyu;Seo, Dong Kook;Choi, Jai Ku;Jang, Young Chul
    • Archives of Plastic Surgery
    • /
    • v.39 no.6
    • /
    • pp.649-654
    • /
    • 2012
  • Background Deep burns of the elbow lead to soft tissue necrosis and infection, with exposure of deep structures. Adequate wound coverage of this area requires thin, pliable, and durable tissue, while optimal functional recovery requires early coverage and functional rehabilitation. We have found 3 types of island flaps that provide reliable coverage for the elbow. Methods A retrospective study was performed on all patients who underwent flap coverage of an elbow defect at our hospital. The patients' data including age, sex, cause of injury, wound dimensions, timing of flap coverage, postoperative elbow motion, and complications were investigated. Results Between 2001 and 2012, 16 patients were treated at our hospital. The mean age was 53.3 years. Three kinds of flaps were performed: 9 latissimus dorsi flaps, 4 lateral arm flaps, and 4 radial forearm flaps. The average defect size was 183.5 $cm^2$ (range, 28 to 670 cm2). Wound coverage was performed at mean duration of 45.9 days (range, 14 to 91 days). The mean postoperative active elbow flexion was $98^{\circ}$ (range, $85^{\circ}$ to $115^{\circ}$). Partial flap failure occurred in 1 latissimus dorsi flap. Minor complications included partial flap loss (11.8%), hematoma (23.5%), seroma (35.3%), and wound infection (5.9%). Conclusions Flap selection for elbow reconstruction is determined by the defect size and the extent of the adjacent tissue injury. Elbow reconstruction using an island flap is a single-staged, reliable, and relatively simple procedure that permits initiation of early rehabilitation, thereby improving a patient's functional outcome.

TISSUE-ENGINEERED RECONSTITUTION OF ORAL MUCOSA USING POLYDIOXANONE MESH (Polydioxanone mesh를 이용한 구강점막의 조직 공학적 재건)

  • Moon, Seon-Jae;Joo, So-Yeon;Kim, Jin;Kim, Hak-Yong;Park, Jung-Keug;Cha, In-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.4
    • /
    • pp.249-256
    • /
    • 2003
  • The lack of sufficient oral mucosa available for intra-oral reconstruction has been dealt with by the use of skin or oral mucosa grafts harvested from donor sites but grafts requires more than one surgical procedures and could cause donor site morbidity. Many investigators have attempted to increase available soft tissue by tissue engineered skin or oral mucosa replacements for clinical applications. But, reconstructed mucosa by several methods have low physical properties such as rolling and contraction. The aims of this study were to develope an in vitro experimental model that maintains an epithelial-mesenchymal interaction by organotypic raft culture, and to characterize biologic properties of three-dimensionally cultured oral mucosa embedded with Polydioxanone mesh by histological and immunohistochemical analysis. The results were as follows; 1. Oral mucosa reconstructed by three-dimensional organotypic culture revealed similar morphologic characteristics to equvalent normal oral mucosa in the point that they show stratification and differentiation. 2. The expression of cytokeratin 10/13 and involucrin in the cultured tissue showed the same pattern with normal oral mucosa suggesting that organotypic co-culture condition is able to induce cellular differentiation. 3. After insertion of polydioxanone mesh, increased tensile strength were observed. These results suggest that three-dimensional organotypic co-culture of the oral mucosa cell lines with the dermal equvalent consisting type I collagen and fibroblasts reproduce the morphologic and immunohistochemical characteristics similar to those in vivo condition. And increased physical properties by use of polydioxanone mesh will helpful for clinical applications.

Experimental In-Vivo Models Used in Fat Grafting Research for Volume Augmentation in Soft Tissue Reconstruction

  • Lujan-Hernandez, Jorge;Appasani, Raghu;Sullivan, Kylee;Siegel-Reamer, Leah;Lalikos, Janice F.
    • Archives of Plastic Surgery
    • /
    • v.44 no.5
    • /
    • pp.361-369
    • /
    • 2017
  • As the popularity of fat grafting research increases, animal models are being used as the source of pre-clinical experimental information for discovery and to enhance techniques. To date, animal models used in this research have not been compared to provide a standardized model. We analyzed publications from 1968-2015 to compare published accounts of animal models in fat grafting research. Data collected included: species used, graft characteristics (donor tissue, recipient area, amount injected, injection technique), time of sacrifice and quantification methods. Mice were most commonly used (56% of studies), with the "athymic nude" strain utilized most frequently (44%). Autologous fat was the most common source of grafted tissue (52%). Subcutaneous dorsum was the most common recipient site (51%). On average, $0.80{\pm}0.60mL$ of fat was grafted. A single bolus technique was used in 57% of studies. Fat volume assessment was typically completed at the end of the study, occurring at less than 1 week to one year. Graft volume was quantified by weight (63%), usually in conjunction with another analysis. The results demonstrate the current heterogeneity of animal models in this research. We propose that the research community reach a consensus to allow better comparison of techniques and results. One example is the model used in our laboratory and others; this model is described in detail. Eventually, larger animal models may better translate to the human condition but, given increased financial costs and animal facility capability, should be explored when data obtained from small animal studies is exhausted or inconclusive.

Laser Resurfacing after Facial Free Flap Reconstruction

  • Kim, Beom-Jun;Lee, Yun-Whan;You, Hi-Jin;Hwang, Na-Hyun;Kim, Deok-Woo
    • Medical Lasers
    • /
    • v.8 no.1
    • /
    • pp.7-12
    • /
    • 2019
  • Background and Objectives Skin and soft tissue defects can be treated according to a range of strategies, such as local flap, skin graft, biological dressing, or free flap. On the other hand, free tissue transfer usually leaves a distinct scar with an inconsistency of color or hypertrophy. This problem is highlighted if the defect is located on the face, which could have devastating effects on a patient's psychosocial health. Materials and Methods The authors used an erbium : yttrium-aluminum-garnet (Er:YAG) laser to resurface the free flap skin and match the color with the surrounding facial skin. This study evaluated the effectiveness of laser skin resurfacing on the harmonious color matching of transferred flap. Patients who had undergone laser resurfacing on facial flap skin between January 2014 and December 2018 were reviewed retrospectively. An ablative 2,940-nm fractional Er:YAG laser treatment was delivered to the entire flap skin at 21 J/cm2 with the treatment end-point of pinpoint bleeding. Several months later, the clinical photographs were analyzed. The L*a*b* color co-ordinates of both the flap and surrounding normal skin were measured using Adobe Photoshop. The L*a*b* color difference (ΔE) for the scar and normal surrounding skin were calculated using the following equation: ${\Delta}E=\sqrt{({\Delta}L)^2+({\Delta}a)^2+({\Delta}b)^2}$ Results All five patients were satisfied with the more natural appearance of the flaps. The ΔE values decreased significantly from the pre-treatment mean value of 19.64 to the post-treatment mean value of 11.39 (Wilcoxon signed-rank test, p = 0.043). Conclusion Ablative laser resurfacing can improve the aesthetic outcome of free tissue transfer on the face.

Sensory Reconstruction in Sensate Radial Forearm Flap Transfer (요측 전완부 감각 피판을 이용한 감각 재건)

  • Lee, Kwang-Suk;Han, Seung-Bum;Suh, Dong-Won;Kim, Hyung-Sik
    • Archives of Reconstructive Microsurgery
    • /
    • v.10 no.2
    • /
    • pp.131-136
    • /
    • 2001
  • Purpose : The sensory radial forearm flap is used to recover the soft tissue defect of hand and foot. The aim of this study is to evaluate the results after sensory reconstruction using sensate radial forearm flaps. Materials and Methods : There were 9 cases of 8 patients (6 males and 2 females). The 7 cases of 6 patients were donated to foot, the 2 cases of 2 patients to hand. At operation, the ages of them ranged from 18 to 63 years (mean: 37.9 years). Sensory evaluation was performed using percentage(%) of responding area to the pinprick test and the static and moving two-point discrimination test (s-2PD and m-2PD). Results : The mean percentage of responding area to the pin prick test was 48.5%. The mean s-2PD and m-2PD of recipient hands were 37.2 mm and 28.8 mm. The mean s-2PD and m-2PD of recipient feet were 46.7 mm and 45.0 mm. The mean s-2PD and m-2PD of controls were 23.5 mm and 19.7 mm. Conclusion : All the recipients were less sensitive than the control, but the recipient hands more sensitive than the recipient feet. Although the small numbers were studied, the results suggested that the recovery of sensation in the innervated flaps was influenced by the recipient nerve. So the donor nerve seems to be selected as more sensitive and more distal nerve of donor site for better outcome.

  • PDF

Reconstruction of the Extended Region of the Upper Auricle Using the Superior Auricular Artery Island Flap (상이개동맥 도상피판을 이용한 이개상부 및 그 주변부의 재건)

  • Kyung, Hyun Woo;Oh, Sang-Ha;Seo, Young Joon;Kim, Dong-Woon
    • Archives of Plastic Surgery
    • /
    • v.36 no.3
    • /
    • pp.289-293
    • /
    • 2009
  • Purpose: The retroauricular flap has many advantages for facial reconstruction and is being performed by many surgeons. However, it is difficult for the retroauricular flap to perform reconstruction of the upper region of the auricle and its surroundings, due to limited rotation arc and length of pedicle. We successfully reconstructed the upper region of the auricle and its surroundings with retroauricular flap by using the superior auricular artery as a supplying pedicle. The purpose of this study is to present an anatomic study about the superior auricular artery and its clinical application. Methods: We investigated the relationship between the superior auricular artery and its surrounding structures through anatomic studies with 7 fresh cadavers and then applied the findings clinically. From February to December 2008, we performed 7 cases of the superior auricular artery island flap to reconstruct the defects in patients operated on skin cancer. Sizes of the defects varied form $0.8{\times}0.8cm$ to $3.5{\times}3.0cm$. Results: We found that the superior auricular artery is a reliable pedicle for the retroauricular flap, based on anatomical studies. All wounds of the patients were successfully closed. The flap donor site was primary closed except in one patient with a large defect. The aesthetic outcomes of the donor and recipient sites were satisfying. Conclusions: The superior auricular artery island flap has several advantages. Therefore, we suggest that the superior auricular artery island flap is a treatment of choice for reconstructing soft tissue defect at the upper region of the auricle and its surrounding area.