• Title/Summary/Keyword: Soft filters

Search Result 35, Processing Time 0.025 seconds

A study on the development of an image processing technique for tracing the movement of heart valves in echocardiograms (I) (심초음파도내에서의 심장 판막 운동 추적을 위한 동영상 처리 기술에 대한 기초 연구 (I))

  • Yook, I.S.;Kim, J.I.;Choi, H.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.88-91
    • /
    • 1997
  • One of the most significant feature of diagnostic ultrasonic instrument is to display information on the soft tissues in the body in real time. In this paper we carried out basic study on the digital moving image processing for tracing the movement of heart valves in echocardiograms. Digital moving image file was made from analog echocardiograms and it was remade as 256 gray-level images on each frame. The ROI(Region of interest) was placed on a heart valve region to process images efficiently. Images were processed by the use of image enhancement filters and morphology filters. The result shows that the processed images were more enhanced than original images. When a moving image is reconstructed by using these enhanced images, we can trace the movement of heart valves more easily. In this study we proposed the availability of the moving image reconstruction using enhancement images.

  • PDF

OBSERVATION SYSTEM OF SOLAR FLARE TELESCOPE (태양플레어망원경의 관측 시스템)

  • Park, Young-Deuk;Moon, Yong-Jae;Jang, Be-Ho;Sim, Kyung-Jin
    • Publications of The Korean Astronomical Society
    • /
    • v.12 no.1
    • /
    • pp.35-45
    • /
    • 1997
  • SOFT($\underline{So}lar\;\underline{F}lare\;\underline{T}elescope$) installed at BOAO(Bohyunsan Optical Astronomy Observatory) is purposed for observing solar active regions using four refractors on single mount with a $400"\times300"$ field of view: Two refractors with a diameter of 15cm(f15) are observe the white light and $H\alpha$, and the other two refractors with a diameter of 20cm(f8) are observe the magnetic field distribution and Doppler shifts at the solar chromosphere. Three Lyot filters, one of the most important observational instruments, are installed on the optical rails for VMG, LMG, and $H\alpha$ that possible to very narrow pass band observation under high precision stability of temperature. From the combination of KD*P and quarter wave plate in the Lyot filter possible observe the magnetic fields strength and doppler shifts by using the characteristics of polarization components. In this paper, we introduce the basic characteristics, optical system, and monitor system of the SOFT.

  • PDF

Nano-granular Co-Fe-Al-Q Soft Ferromagnetic Thin Films for RF Electromagnetic-noise Filters

  • Sohn, Jae-Cheon;Byun, Dong-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.42-50
    • /
    • 2006
  • Co-Fe-Al-O nano-granular thin films with high electrical resistivity, fabricated by radio frequency magnetron sputtering under an $Ar+O_2$ atmosphere, are found to show good soft magnetic properties in the GHz frequency range. The real part value of the relative permeability is 260 at low frequencies and this value is maintained up to the GHz frequency range. A non-integrated type noise filter on a coplanar waveguide transmission line is demonstrated by using the Co-Fe-Al-O nano-granular thin film with the dimensions of $4\;mm(l){\times}4\;mm(w){\times}0.1\;{\mu}m(t)$. The insertion loss is very low being less than 0.3 dB and this low value is maintained up to 2 GHz. At a ferromagnetic resonance frequency of 3.3 GHz, the degree of noise suppression is measured to be 3 dB. This level of noise attenuation is small for real applications, but there is much room for further improvement by increasing the magnetic volume and integrating the magnetic thin film into the CPW transmission line.

The Usage of Copper Slag as The Drainage Materials (동 수매 슬래그의 배수용 재료로써의 이용)

  • 민덕기;황광모;이경준;김현도
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.453-458
    • /
    • 2001
  • Copper slag is produced about 700,000 tons annually though copper refining process in Korea. In the paper, a laboratory investigation was carried out to estimate the geotechnical properties of copper slag and examine the feasibility of using the copper slag as a substitute for conventional construction materials and the improvement of the soft clay deposit. The specific gravity of copper slag is 3.45, and pH is 7.83. And the size distribution of the copper slag is well graded, so usage of copper slag will be extended in Geotechnical engineering fields. Copper slag has the permeability of 3.502${\times}$10 ̄$^2$cm/sec, which is satisfied with the criterion of sand drainage materials.. At the same time, it is thought to be suitable material for sand mat since it meets JIS of grain size distribution. The content of CaO from steel slag is about 40 percent while that of CaO from copper slag is about 5 percent. Based on this fact, copper slag has less hardening property compared to steel slag. Therefore, copper slag can be used as vertical drains, filters, and sand mats for improving the soft deposit.

  • PDF

Image Signal Denoising by the Soft-Threshold Technique Using Coefficient Normalization in Multiwavelet Transform Domain (멀티웨이블릿 변환영역에서 계수정규화를 이용한 Soft-Threshold 기법의 영상신호 잡음제거)

  • Kim, Jae-Hwan;Woo, Chang-Yong;Park, Nam-Chun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.4
    • /
    • pp.255-265
    • /
    • 2007
  • In case of wavelet coefficients have correlation, in image signal denoising using wavelet shrinkage denoising method, the denoising effect for the image signal is reduced when the wavelet shrinkage denoising method is used. The coefficients of multiwavelet transform have correlation by pre-filters. To solve the degradation problem in multiwavelet transform, V Sterela suggested a new pre-filter for the Universal threshold or weighting factors to the threshold. In this paper, to improve the denoising effect in the multiwavelet transform, the coefficient normalizing method that the coefficient are divided by estimated noise deviation is adopted to the transformed multiwavelet coefficients in the course of wavelet shrinkage technique. And the thresholds of universal, SURE and GCV are estimated using normalized coefficients and tried to denoise by the wavelet shrinkage technique. We compared PSNRs of denoised images for each thresholds and confirmed the efficiency of the proposed method.

  • PDF

Bioengineering Approaches to Quantitation of Diagnosis and Treatment Monitoring for Patients with Liver Cancer: Ultrasonic Image Processing by Kalman Filtering (의공학적 기법에 의한 간암의 검진과 치료경과의 정량 : 칼만 필터링 기법에 의한 초음파 영상 처리)

  • 우광방;남상일
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.1
    • /
    • pp.5-12
    • /
    • 1985
  • In this paper Kalman filtering technique is applied to ultrasound signal to improve resolution capability, Ivhlch is in use of diagnostic imaging systems. The main advantage of Kalman filter algorithm for the analysis of reflected ultrasound signal is its recursive structure which can be easily adapted to tlme varing system. Because soft-tissues, such as liver, act as distributed acoustic low-pass filters which continually change the propagating pulse. tIne can put to practical use above advantage to find a suitable signal generallng model. In state-space description of the system, the 6th order system produces tl)e 1)esc spectral approximation to the source pulse As a result of spectrum analysis, 6th order estimator for two closely spaced ((p.5 mm) reflectors enhances resolution by 4dB-lOdB. By using this result, the possibility to detect even minute tumor is demonstrated.

  • PDF

Detection of Pulmonary Nodules' Shadow on Chest X-ray Image (흉부 X선 영상에 있어서 폐 종류 음영의 검출)

  • Kim, Eung-Kyeu;Lee, Do-Kyeom
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.293-294
    • /
    • 2007
  • The purpose of this study is prove the effectiveness of an energy subtraction image for the detection of pulmonary nodules and the effectiveness of multi-resolutional filter on an energy subtraction image to detect pulmonary nodules. Also we study influential factors to the accuracy of detection of pulmonary nodules from viewpoints of types of images, types of digital filters and types of evaluation methods. As one type of images, we select an energy subtraction image, which removes bones such as ribs from the conventional X-ray image by utilizing the difference of X-ray absorption ratios at different energy between bones and soft tissue. Here we select two evaluation methods and make clear the effectiveness of multi-resolutional filter on an energy subtraction image.

  • PDF

The Evaluation of Images with Various Filters in I-131 SPECT/CT (I-131 SPECT/CT에서 Ringing Artifact 감소를 위한 다양한 Filter값의 적용)

  • Kim, Ha Gyun;Kim, Soo Mee;Woo, Jae Ryong;Oh, So Won;Lee, Jae Sung;Kim, Yu Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.62-68
    • /
    • 2014
  • Purpose: After I-131 therapy, SPECT/CT is useful in identifying location of thyroid remnants and metastasis of thyroid cancers. An excessive uptake of thyroid leads to a ringing artifact in the SPECT images. The aim of this study is to investigate and suggest a proper post filters to remove ringing artifact and produce better image quality. Materials and Methods: A low-cost, customized thyroid-mimicking phantom, consisting of an acrylic bottle and a hollow sphere was used for SPECT/CT Discovery (GE Healthcare, USA). It was filled with I-131 solution. The ratio of hollow sphere to background were varied as 50:1, 200:1, 1000:1 and 4000:1. Acquired images were reconstructed by OSEM (2 iterations, 10 subsets) with and without Evolution (resolution recovery correction, GE). Three different post-filters were applied; Butterworth (cut off: 0.38 to 0.58 with intervals of 0.05), Hanning (cut off: 0.8 to 1 with intervals of 0.05) and Gaussian (FWHM: 3 to 5 with intervals of 0.5) filters. Contrast, background variability, air area variability, and full width half maximum (FWHM) were compared. Results: Higher contrasts were obtained from the SPECT images with Evolution than without Evolution. In the case of images without Evolution, image distortion such as star artifact was generated. For all sphere-to-background ratio, the Butterworth filter showed better constrasts and FWHMs than other two filters, but the ringing artifact was still generated in all studies except 50:1 and it was decreased as cutoff value was increased. The ringing artifact didn't appear with Hanning and Gaussian filters at all studies, however constrats and FWHMs with Gaussian was worse than Hanning filter. For the images having ringing artifacts, the background variability and air area variability were increased. Conclusion: In this study, we suggested that it is desirable to use Hanning filter when the ringing artifact is generated and to use Butterworth filter when ringing artifact is not generated in I-131 SPECT.

  • PDF

Prototype Electromagnetic-Noise Filters Incorporated with Nano-Granular Co41Fe38Al13O8 Soft Ferromagnetic Thin Films on Coplanar Transmission Lines

  • Sohn, Jae-Cheon;Byun, Dong-Jin
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.2 s.285
    • /
    • pp.74-78
    • /
    • 2006
  • A non-integrated type noise filter on a Coplanar Waveguide (CPW) transmission line is demonstrated by using a highly resistive $Co_{41}Fe_{38}Al_{13}O_8$ nanogranular thin film with the dimensions of $4\;mm (\iota)\times4\;mm(\omega)\times0.1\;{\mu}m(t)$. The noise suppression characteristics are evaluated without placing an insulating layer between the CPW line and the magnetic thin film. The insertion loss is very low being less than 0.3 dB and this low value is maintained up to 2 GHz. At a ferromagnetic resonance frequency of 3.3 GHz, the power loss is very large and the degree of noise attenuation is measured to be 3 dB. This level of noise attenuation is still small for real applications; however, considering the small magnetic volume used in this work, further improvement is expected by simply increasing the magnetic volume and by integrating the magnetic thin film into the CPW transmission line.

Local Adaptive Noise Cancellation for MCG Signals Based on Wavelet Transform (웨이브릿 변환을 기반으로 한 심자도 신호의 국소 적응잡음제거)

  • 김용주;박희준;원철호;이용호;김인선;김명남;조진호
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.26-30
    • /
    • 2003
  • Magneto-cardiogram(MCG) signals may be highly distorted by the environmental noise, such as power-line interference, broadband white noise, surrounding magnetic noise, and baseline wondering. Several kinds of digital filters and noise cancellation methods have been designed and realized by many researchers, but these methods gave some problems that the original signal may be distorted by digital filter due to the wideband characteristics of background noise. To eliminate noise effectively without distortion of MCG signals, we performed multi-level frequency decomposition using wavelet packets and local adaptive noise cancellation in each local frequency range. In addition to the proposed wavelet filter to eliminate these various non-stationary noise elements, the local adaptive filter using the least mean square(LMS) algorithm and the soft threshold do-noising method are introduced in this paper. The signal to noise ratio(SNR) and the reconstruction square error(RSE) are calculated to evaluate the performance of the proposed method and compared with the results of the conventional wavelet filter and adaptive filter. The experimental results show that the proposed local adaptive filtering method is better than the conventional methods.

  • PDF