• Title/Summary/Keyword: Soft contact

Search Result 364, Processing Time 0.028 seconds

The adsorption pattern of protein to the soft contact lens and its effect on the visible light transmission and the contact angle (소프트콘택트렌즈의 단백질 부착 양상 및 가시광선투과도와 접촉각에 미치는 영향)

  • Park, Mijung;Kwon, Mi Jeong;Lee, Sun Hee;Kim, Daesoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.53-68
    • /
    • 2004
  • Protein deposit buildup on soft contact lenses(SCLs) is responsible for discomfort, optical defects and is even damaging to the eye. To better understand protein deposit formation on SCL, we investigated the pattern of protein attachment on patient-worn SCLs and the effect of the protein on the contact angle of SCLs and the transmission of visible light. This study used data from a clinical trial where subjects wore either daily-wear SCL(etafilcon A, N=40) for various period up to 14 days, or extended-wear SCL(balafilcon A, N=40) for 8 h day or night. The adsorption of protein in daily-wear SCLs was significantly increased in patient-worn time-dependent manner although the lenses were cleaned everyday by using the multi-purpose SCL solution. After 2 weeks wearing, the protein on the SCL influenced the contact angle of the lenses. Furthermore, the transmission of visible light of the lenses decreased up to almost 7%. Extended-wear SCLs worn during the closed eye condition were found to deposit significantly more protein than SCLs worn during the open eye condition. The amounts of protein adsorbed both after daily SCL wear and after overnight SCL wear were not affected the contact angle and the transmission of visible light of the lenses. The protein deposit buildup on SCL related to the corneal temperature and pH of tear fluid.

  • PDF

Study of Masking Effect of Soft Contact Lenses on Cornea after Refractive Surgery (각막굴절교정 수술 안에 대한 소프트콘택트렌즈 착용 시 Masking 효과)

  • Moon, Ye-Rim;Park, Hyung-Min;Chu, Byoung-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.91-98
    • /
    • 2016
  • Purpose: This study investigated the masking effect of the hydrogel lens and silicone hydrogel lens on the cornea with refractive surgery and without surgery. Methods: 24 university students (means age: $23.48{\pm}2.89years$) without refractive surgery (12, control group) and with refractive surgery (LASIK: 8, LASEK: 4, experimental group) participated in the study. Mean refractive errors of right eyes were -2.73 D for control group and -0.24 D for experimental group. The differences in the refractive power and corneal topography map between pre- and post-wearing the -3.00 D lenses were compared, and 2 kinds of hydrogel contact lenses (0.89 Mpa, 0.49 Mpa) and 2 kinds of silicone hydrogel lenses (1.5 Mpa, 0.8 Mpa) were used for -3.00 D lenses. NVision-K5001 (Shin nippon, Japan) was used to measure the refractive power and Keratograph 5M (Oculus, Germany) to measure the corneal topography map change. Results: Variations in the refractive power increased to the plus direction in the experimental group after wearing soft contact lenses. The corneal topography map showed significant changes on the both groups after wearing soft contact lenses (p<0.05). However there were no significant differences in the refractive power and corneal topography map variations by lens materials. Conclusions: Wearing soft contact lenses showed corneal topography map changes. Especially wearing soft contact lenses on the flat cornea after corneal refractive surgery showed greater corneal power changes. Therefore, it should pay attention to refractive change in case of prescribing soft contact lenses to patients with corneal refractive surgery.

Numerical Analysis for Evaluation of Bearing Capacity on Soft Ground with Geotextile (Geotextile이 포설된 연약지반 지지력 평가를 위한 수치해석 비교분석)

  • Chae, Yu-Mi;Kim, Jae-Hong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.2
    • /
    • pp.217-223
    • /
    • 2020
  • As construction work on soft ground increases, many researchers have studied to secure the stability of trafficability with interest in construction safety accidents due to reinforcement work. Although the stability of soft ground is evaluated based on the allowable bearing capacity of theoretical equations proposed in the literature such as Yamanouchi and Meyerhof formulas, further numerical verification also requires comparison of the stress increase (Δσz) and deformation of the distributed contact pressure on the soft ground. In this study, the deformation of the soft ground is compared with the increasing the seam tensile strength of geotextile using the finite element analysis program, and the stress increase is investigated by variation of the distributed contact pressure by appling input data of case study.

Adsorption of methyl orange from aqueous solution on anion exchange membranes: Adsorption kinetics and equilibrium

  • Khan, Muhammad Imran;Wu, Liang;Mondal, Abhishek N.;Yao, Zilu;Ge, Liang;Xu, Tongwen
    • Membrane and Water Treatment
    • /
    • v.7 no.1
    • /
    • pp.23-38
    • /
    • 2016
  • Batch adsorption of methyl orange (MO) from aqueous solution using three kinds of anion exchange membranes BI, BIII and DF-120B having different ion exchange capacities (IECs) and water uptakes ($W_R$) was investigated at room temperature. The FTIR spectra of anion exchange membranes was analysed before and after the adsorption of MO dye to investigate the intractions between dye molecules and anion exchange membranes. The effect of various parameters such as contact time, initial dye concentration and molarity of NaCl on the adsorption capacity was studied. The adsorption capacity found to be increased with contact time and initial dye concentration but decreased with ionic strength. The adsorption of MO on BI, BIII and DF-120B followed pseudo-first-order kinetics and the nonlinear forms of Freundlich and Langmuir were used to predict the isotherm parameters. This study demonstrates that anion exchange membranes could be used as useful adsorbents for removal of MO dye from wastewater.

Effects of UV-A Blocking Contact Lenses on the Enzymes Denaturation Induced by UV-A Irradiation (UV-A로 유발된 효소 변성에 대한 콘택트렌즈의 차단 효과)

  • Park, Mijung;Lee, Keum Hee;Lee, Eun Kyung;Park, Sang Hee;Kim, So Ra;Lee, Heum Sook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.43-49
    • /
    • 2008
  • Purpose: The current study was conducted to evaluate the compatibility of UV-A blocking contact lens on eye protection with regular contact lens. Methods: The protective activity of regular contact lens (UV-A blocking: 20%) and UV-A blocking contact lens (UV-A blocking: 85%) on the denaturation of RNase A, catalase, and superoxide dismutase (SOD) induced UV-A irradiation were compared by acrylamide gel electrophoresis. The enzyme solutions were irradiated with UV-A for 1, 3, 6, 24 and 96 hours at the wavelength of 365 nm. Covering area with contact lenses were varied as 50%, 70% and 100% according to the calculation of blocking areas of anterior eye that could be covered with RGP lens, soft contact lens, and eye glasses, respectively. Results: Denaturations of RNase, catalase and SOD were exaggerated when they were exposed to UV-A for a longer period. The denaturation was effectively prevented by UV-A blocking contact lens compared to regular contact lens. The capability of UV-A blocking contact lens was considerably reduced when the covering area with contact lens decreased and exposure time to UV-A extended. Conclusion: Therefore, it would be suggested that wearing contact lens for a long time under sunlight is carefully considered since the activity of UV-A blocking contact lens against UV-A irradiation may not be enough to protect enzymes presented in eyes when exposure time to UV-A increased.

  • PDF

The Comparative Analysis for the Progression of Dry Eyes Caused by Wearing Soft Contact Lenses(SCL) and Cosmetic Soft Contact Lenses(C-SCL) (소프트 콘택트렌즈와 미용 콘택트렌즈의 건성안 진행에 대한 비교분석)

  • Kim, Myoung-Jin;Hwang, Hye-Kyung;Jang, Woo-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.375-381
    • /
    • 2011
  • Purpose: The purpose of this research was to see how wearing either a SCL or a C-SCL effected the dryness of a person's eye depending on how long they wear either type of lens. Methods: This study was carried out on 52 subjects (104 eyes) who were all in their twenties and had previously experienced wearing contact lenses. All of these subjects were required to wear either a SCL or a C-SCL, which were made out of the same material, for three months. Contents such as the McMonnies Questionnaire survey, the blinking rate per min. and the Noninvasive tear break-up time test (NIBUT) were later conducted on the subjects for this study. Results: According to the results of the McMonnies Questionnaire, it was concluded that the longer the subject wore the SCL and C-SCL, the value of the measurements gradually increased. On the other hand, the results from the NIBUT concluded that the longer the subject wore the SCL, the value of the measurements eventually decreased. However, according to the measurements of the blink rate test, it was concluded that neither results had a significant change. Conclusions: It was concluded that long-term wearing of SCL and C-SCL could be the cause of the induction and progression of dry eyes.

Difference in Rotation Pattern of Toric Soft Contact Lenses with Different Axis Stabilization Design (축 안정화 디자인이 상이한 토릭소프트콘택트렌즈의 회전 양상 차이)

  • Park, So Hyun;Kim, Dong Yeon;Choi, Joo Hee;Byun, Hyun Young;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.133-140
    • /
    • 2015
  • Purpose: It was investigated whether two different stabilization designs of toric contact lenses changed the rotational axis and degree of toric lenses according to body posture and gaze direction in the present study. Methods: Toric soft contact lenses with Lo-Torque$^{TM}$ design and ASD design (accelerated stabilized design) were fitted on 52 eyes aged in 20s-30s. Then, rotational degree was measured at the five gaze directions including front gaze and the lying position. Results: When gazing the front and vertical directions in the upright posture, lens was much rotated to nasal side for the Lo-Torque$^{TM}$ design and temporal side for the ASD design. When gazing horizontal direction, both design lenses were rotated against to the gaze direction. Rotation degree was the smallest at superior direction gaze and the largest at nasal gaze. In case of the rotation degree less than $5^{\circ}$, Lo-Torque$^{TM}$ design was more frequent when gazing front and vertical directions, and ASD design was more frequent when gazing horizontal direction. In addition, the lens with Lo-Torque$^{TM}$ design was lesser rotation degree than with ASD design immediately after lying. On the other hand, the lens with ASD design was lesser rotation degree than with Lo-Torque$^{TM}$ design 1 minute later after lying. Conclusions: This study confirmed that axis rotation of the lens induced by gaze direction and posture was different according to axis stabilization design during wearing toric soft contact lens.

Research of Controlled Motion of Dual Fingers with Soft-Tips Grasping (Soft-Tip을 가진 Dual Finger의 파지운동제어에 관한 연구)

  • 박경택;양순용;한현용
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.670-673
    • /
    • 2000
  • This paper attempt analysis and computer simulation of dynamics of a set of dual multi-joint fingers with soft-deformable tips which are grasping. Firstly, a set of differential equation describing dynamics of the fingers and object together with geometric constraint of tight area-contacts is formulated by Euler-Lagrange's formalism. Secondly, problems of controlling both the internal force and the rotation angle of the grasped object under the constraints of area-contacts of tight area-contacts are discussed. The effect of geometric constraints of area-contacts on motion of the overall system is analyzed and a method of computer simulation for overall system of differential-algebraic equations is presented. Finally, simulation results are shown and the effects of geometric constraints of area-contact is discussed.

  • PDF

Microbial Contamination of Contact lens cases in multi - purpose solution care systems (다목적 용액을 사용하는 콘택트렌즈 관리체계에서 렌즈 보관용기의 미생물 오염)

  • Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.95-99
    • /
    • 2000
  • The microbial contamination rate of contact lens cases in multi-purpose solution(MPS) care systems of 80 asymptomatic soft contact lens wearers was investigated. In caring for their lenses 72 patients (90%) used chemical disinfection(include MPS), six patients(7%) used hydrogen peroxide, and two patients(3%) used heat. Fifty-nine percent of patients used MPS in their care systems. Of 80 contact lens cases, contamination was found in 68%(54) of cases. There is a significant relationship between the ages of lens cases and contamination: older cases being more frequently contaminated. Of the contaminated 31 lens cases(57%) in MPS care systems, four contact lens cases(13%) were contaminated by single organism, 15 cases(48%) by two kinds of organisms, and 12 cases(39%) by more than three kinds of organisms. Of the organisms that were contaminated lens cases, Pseudomonas. Serratia, Bacillus, E. coli and Aspergillus were frequently isolated. When considering the high contamination rate of soft contact lens cases in MPS care systems more effective and hygienical lens care system is important, especially frequent and regular disposal of lens cases may prove to prevent the build-up of microbial colonisation in containers.

  • PDF

Study on the Development of Wet Cell Holder for the Measurement of Hydrophilic Contact Lens (친수성 콘택트렌즈 측정용 Wet Cell 홀더 개발에 관한 연구)

  • Song, Kyoung-Sek;Lim, Hyeon-Sun;Joo, Seok-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.455-462
    • /
    • 2015
  • Purpose: To develop more accurate wet measuring system combining the wet cell, automatic lensmeter and the related software for hydrophilic contact lenses and to verify the accuracy of those measuring holder system already available in the market. Methods: Refractive power measurement were done in both a conventional method which has been commonly used in optical shops and a new method which is recently developed in korea. Hydrophilic contact lens of korean brand was chosen as a test material and was tested by water content ratio and by spherical refractive power. Results: When spherical power of -3.00 D contact lens is measured in the newly developed wet cell measurement holder with automatic lensmeter, it reads -3.01 D at water content ratio of 38%. -3.00 D at 45% and -2.98 D at 58%. The same experiment with the Poster soft contact lens wet cell measurement holder maintaining other conditions same resulted in -3.60 D at the water content ratio of 38%, -3.06 D at 45% and -2.46 D at 58%. Conclusions: At the higher water content, the refractive power values measured by both of the wet cell measuring holders are shown lower, and additionally, the new method using the wet cell holder and new software program in a automatic lensmeter showed more accurate readings than conventional Poster soft contact lens wet cell measuring system.