• Title/Summary/Keyword: Soft contact

Search Result 364, Processing Time 0.022 seconds

A study on structural feature and size distribution of swimming fish using an 3 dimensional pattern laser (3차원 패턴 레이저를 이용한 유영어류의 형태 및 크기 측정)

  • YANG, Yongsu;LEE, Kyounghoon;PYEON, Yongbeom;YOON, Eun-A;LEE, Dong-Gil;JO, Hyun-Su
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.52 no.2
    • /
    • pp.103-110
    • /
    • 2016
  • This study aims to estimate the species, size and shape of fish using a non-contact 3 dimensional pattern laser so that this preliminary test was carried out to understand the structural feature and length of goldfish according to water turbidity and depth in the aquacultural tank. 3-D pattern laser could clearly detect its morphological shape except the caudal fin due to soft tissue. Since the sensing strength of line laser light according to depth has sufficient power, it is possible to measure its depth and structural feature in the detected range. The result showed that the measured error of individual's fork length was less than ${\pm}1%$ in the water using 3-D pattern laser, when compared with the measured value in the air.

EXPERIMENTAL STUDIES ON THE TISSUE RESPONSE OF HA COATED, TPS AND $Al_2O_3$ ARTIFICIAL ROOT IMPLANTS (HA, TPS 및 $Al_2O_3$ 인공치근 매식체의 조직반응에 관한 실험적 연구)

  • Kim, Sun-Young;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.267-284
    • /
    • 1991
  • Since the concept of a direct contact between bone and implants, without interposed soft- tissue layers, was reported by Dr. $Br{\aa}nemark$, there has been increasing necessity for correct under-standing of bone-implant interface and surrounding tissue response. Beside quality of bone, surgical technique, load applied to implants, one must consider implant materials, design and surface characteristics to obtain osseointegration. In this study HA plasma-sprayed implants, TPS implants and $Al_2O_3$ implants were inserted into the alveolar bone of dog and tissue response was observed with radiograph, stereoscope, light microscope, and scanning electron microscope. Results were as follows : 1. There was rapid and active bone formation in the region adjacent to HA plasma-sprayed implants but in the deep supporting bone only slight bone formation was seen. 2. There was considerable lamella bone formation in the region adjacent to TPS implants and the deep supporting bone became more compact. 3. There was some gap and sclerosing bone formation in the adjacent region of $Al_2O_3$ implants, but there was irregular new bone formation in the deep supporting bone. Therefore, it seems that $Al_2O_3$ is not adequate for osseointegrated implants.

  • PDF

Development of a Finite Element Human Neck Model for Neck Injury Analysis - Application to Low Speed Rear-End Offset Impacts - (목상해 분석을 위한 상세 유한요소 목모델 개발 - 저속후방 오프셋 충돌에 따른 분석 -)

  • Kim Young Eun;Jo Hui Chang
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.6 s.237
    • /
    • pp.913-920
    • /
    • 2005
  • Compared to previous in-vitro test, FE model showed reliable motion patterns. A finite element model of a 50th percentile male neck was developed to study the mechanics of whiplash injury while the rear impacts. The model was consisted of the whole cervical vertebrae including part of occipital, intervertebral discs. which were modeled using linear viscoelastic materials and posterior elements. The sliding interfaces were defined to simulate contact phenomena in facet joints and in odontoid process. All ligaments and atlanto-occipital membrane were modeled as nonlinear bar elements. Only muscle elements were not considered. Motion of each cervical vertebra was obtained from the dynamic simulation with a MADYMO model for 15 km/h $40\%$ rear end offset impacts. Soft tissue neck injury(STNI) was investigated with a developed FE model. In FE model analysis, the high stress was appeared at C3/C4 disc in offset impact. Further research is still needed in order to improve the developed neck FE model for many different crash patterns.

Biomimetically Engineered Polymeric Surfaces for Micro-scale Tribology

  • Singh R. Arvind;Kim Hong-Joon;Kong Ho-Sung;Yoon Eui-Sung
    • KSTLE International Journal
    • /
    • v.7 no.1
    • /
    • pp.14-17
    • /
    • 2006
  • In this paper, we report on the replication of surface topography of natural leaf of Lotus onto thin polymeric films using a capillarity-directed soft lithographic technique. PDMS molds were used to replicate the surface. The replication was carried out on poly(methyl methacrylate) (PMMA) film coated on silicon wafer. The patterns so obtained were investigated for their friction properties at micro-scale using a ball-on-flat type micro-tribo tester, under reciprocating motion. Soda lime balls (1 mm diameter) were used as counterface sliders. Friction tests were conducted at a constant applied normal load of $3000{\mu}N$ and speed of 1mm/s. All experiments were conducted at ambient temperature ($24{\pm}1^{\circ}C$) and relative humidity ($45{\pm}5%$). Results showed that the patterned samples exhibited superior tribological properties when compared to the silicon wafer and non patterned sample (PMMA thin film). The reduced real area of contact projected by the surfaces was the main reason for their enhanced friction property.

Abrasive Wear Characteristics of Materials for Diesel Engine Cylinder Liner and Piston Ring (디젤엔진 실린더 라이너-피스톤 링 소재의 연삭 마멸 특성)

  • Jang, Jeong-Hwan;Kim, Jung-Hoon;Kim, Chang-Hee;Moon, Young-Hoon
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.20 no.2
    • /
    • pp.72-77
    • /
    • 2007
  • Abrasive wear between piston ring face and cylinder liner is an extremely unpredictable and hard-to-reproduce phenomenon that significantly decreases engine performance. Wear by abrasion are forms of wear caused by contact between a particle and solid material. Abrasive wear is the loss of material by the passage of hard particles over a surface. From the pin-on-disk test, particle dent test and scuffing test, abrasive wear characteristics of diesel engine cylinder liner-piston ring have been investigated. Pin-on-disk test results indicate that abrasive wear resistance is not simply related to the hardness of materials, but is influenced also by the microstructure, temperature, lubricity and micro- fracture properties. In particle dent test, dent resistance stress decreases with increasing temperature. From the scuffing test by using pin-on-disk tester, scuffing mechanisms for the soft coating and hard coating were proposed and experimentally confirmed.

Vascularisation of Urethral Repairs with the Gracilis Muscle Flap

  • Kua, Ee Hsiang Jonah;Leo, Kah Woon;Ong, Yee Siang;Cheng, Christopher;Tan, Bien-Keem
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.584-588
    • /
    • 2013
  • Background The ability to achieve a long-term, stricture-free urethral repair is one of the ongoing challenges of reconstructive urologic surgery. A successful initial repair is critical, as repeat procedures are difficult, owing to distortion, scarring, and short urethral stumps. Methods We describe a technique in which the gracilis muscle flap is laid on or wrapped around the urethral repair site to provide a well-vascularised soft tissue reinforcement for urethral repair. This technique promotes vascular induction, whereby a new blood supply is introduced to the repair site to improve the outcome of urethral repair or anastomotic urethroplasty. The surface contact between the muscle flap and the repair site is enhanced by the use of fibrin glue to improve adherence and promote inosculation and healing. We employed this technique in 4 patients with different urethral defects. Results After a follow-up period of 32 to 108 months, all of the urethral repairs were successful without complications. Conclusions Our results suggest that the use of a gracilis muscle flap to vascularise urethral repairs can improve the outcome of challenging urethral repairs.

The Flexible Characteristic of Reversible and Robust Nanohair Fastener

  • Park, Seung-Ho;Yoon, Young-Seok;Lee, Dong-Woo;Lee, Dong-Ik;You, Kyoung-Hwan;Pang, Chang-Hyun;Suh, Kahp-Yang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.432-432
    • /
    • 2011
  • Dry adhesion caused by Nanoscale contact comes up to important scientific issue. Herein, we introduce bendable nanohairy locking fastener system with high shear strength and mechanically flexible backing. The polymeric patches like velcro are composed of an array of straight nanohairs with 100 nm diameter and $1{\mu}m$ height. To fabricate high aspect vertical nanohairs, we used UV molding method with appropriately flexible and rigid polyurethane acrylate material on PET substrate. Two identical nanohairy patches are easily merged and locked each other induced by van der Waals force. Because nanohairs can be arrayed with high density ${\sim}4{\times}10^8/cm^2$, we can obtain high shear adhesion force on flat surface (~22 N/$cm^2$). Furthermore, we can obtian nanohairy locking system with maximum shear adhesion ~48 N/$cm^2$ of curved surface due to flexibility of PET substrate. We confirm the tendency that shear adhesion force increases, as radius of curvature increases.

  • PDF

The Changes of Skin Temperature and Subjective Fatigue of the Thoracic Vertebrae by the Chiropractic Adjustments (흉추에 적용한 척추교정이 피부온도와 주관적 피로에 미치는 영향)

  • Yoon, Jung-Gyu;Lee, Geon-Cheol
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.102-108
    • /
    • 2003
  • The purpose of this study was to determine the changes of skin temperature and subjective fatigue of the thoracic vertebrae by the chiropractic adjustments. Stimulation of the sympathetic nervous system will cause the changes in the skin blood flow which can be detected by measuring the skin surface temperature. This study was to see whether chiropractic adjustments could affect the activity of the sympathetic nervous system as reflected by changes in skin temperature of the thoracic. Skin temperature and subjective fatigue on 16 subjects was measured before, within 10 sec, 10min, 20min and 30 min after a thoracic adjustment with Digital Infrared Thermal Imaging(DITI) and Visual Analogue Scale(VAS). The adjustments consisted of a straight posterior-to-anterior high-speed, low-amplitude thrust to the transverse process of T3-T10 using a reinforced hypothenar contact. The average temperature and fatigue changed when the spine was considered as an entire unit. These results illustrate that the blood flow through the soft tissue can be affected by specific adjustments to the spine. This study might be served as an useful baseline data for the changes of the circulation and fatigue after the chiropractic adjustments.

  • PDF

THERMAL POLYMERIZATION OF 2-HYDROXYETHYL METHACRYLATE WITH PHENYLSILANS (PHENYLSILANS와 2-HYDROXYETHYL METHACRYLATE의 열중합)

  • Sung, A Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.87-90
    • /
    • 2000
  • Poly(HEMA)s have been used as the optometric material for the preparation of soft contact lens. The bulk thermal polymerization of 2-hydroxyethyl methacrylate (HEMA) with various hydrosilanes such as $phSiH_3$, $phMeSiH_2$, and $ph2SiH_2$ were performed to produce poly(HEMA)s containing phenylsilyl end moeity. It was found for thermal polymerization that while the polymerization yield and polymer molcular weights decreased as the relative phenylsilane concentration increases, the TGA residue yields and the relative intensities of SiH IR stretching bands increased as the relative hydrosilane concentration increases over HEMA. The polymerization yield, molecular weight, and TGA residue for the thermal polymerization were higher than those for the photo polymerization. Thus, the hydrosilanes significantly influence on the polymerization as both chain-initiation and chain-transfer agents.

  • PDF

Structure-soil-structure interaction in a group of buildings using 3D nonlinear analyses

  • Sharifi, Behroozeh;Nouri, Gholamreza;Ghanbari, Ali
    • Earthquakes and Structures
    • /
    • v.18 no.6
    • /
    • pp.667-675
    • /
    • 2020
  • The current study compares the effect of structure-soil-structure interaction (SSSI) on the dynamic responses of adjacent buildings and isolated structures including soil-structure interaction (SSI) with the responses of fixed-base structures. Structural responses such as the relative acceleration, displacement, drift and shear force were considered under earthquake ground motion excitation. For this purpose, 5-, 10- and 15-story structures with 2-bay moment resisting frames resting on shallow foundations were modeled as a group of buildings in soft soil media. Viscous lateral boundaries and interface elements were applied to the soil model to simulate semi-infinite soil media, frictional contact and probable slip under seismic excitation. The direct method was employed for fully nonlinear time-history dynamic analysis in OpenSees using 3D finite element soil-structure models with different building positions. The results showed that the responses of the grouped structures were strongly influenced by the adjacent structures. The responses were as much as 4 times greater for drift and 2.3 times greater for shear force than the responses of fixed-base models.