• Title/Summary/Keyword: Soft contact

Search Result 364, Processing Time 0.029 seconds

Tissue integration of zirconia and titanium implants with and without buccal dehiscence defects

  • Lim, Hyun-Chang;Jung, Ronald Ernst;Hammerle, Christoph Hans Franz;Kim, Myong Ji;Paeng, Kyeong-Won;Jung, Ui-Won;Thoma, Daniel Stefan
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.3
    • /
    • pp.182-192
    • /
    • 2018
  • Purpose: The purpose of the present study was to validate an experimental model for assessing tissue integration of titanium and zirconia implants with and without buccal dehiscence defects. Methods: In 3 dogs, 5 implants were randomly placed on both sides of the mandibles: 1) Z1: a zirconia implant (modified surface) within the bony housing, 2) Z2: a zirconia implant (standard surface) within the bony housing, 3) T: a titanium implant within the bony housing, 4) Z1_D: a Z1 implant placed with a buccal bone dehiscence defect (3 mm), and 5) T_D: a titanium implant placed with a buccal bone dehiscence defect (3 mm). The healing times were 2 weeks (one side of the mandible) and 6 weeks (the opposite side). Results: The dimensions of the peri-implant soft tissue varied depending on the implant and the healing time. The level of the mucosal margin was located more apically at 6 weeks than at 2 weeks in all groups, except group T. The presence of a buccal dehiscence defect did not result in a decrease in the overall soft tissue dimensions between 2 and 6 weeks ($4.80{\pm}1.31$ and 4.3 mm in group Z1_D, and $4.47{\pm}1.06$ and $4.5{\pm}1.37mm$ in group T_D, respectively). The bone-to-implant contact (BIC) values were highest in group Z1 at both time points ($34.15%{\pm}21.23%$ at 2 weeks, $84.08%{\pm}1.33%$ at 6 weeks). The buccal dehiscence defects in groups Z1_D and T_D showed no further bone loss at 6 weeks compared to 2 weeks. Conclusions: The modified surface of Z1 demonstrated higher BIC values than the surface of Z2. There were minimal differences in the mucosal margin between 2 and 6 weeks in the presence of a dehiscence defect. The present model can serve as a useful tool for studying peri-implant dehiscence defects at the hard and soft tissue levels.

Late Quaternary Paleoenvironmental Changes in the Western Nakdong River delta (낙동강 삼각주 서부지역의 제4기 후기 고환경 변화)

  • Ryu, Choon-Kil;Kang, Sora;Chung, Sung-Gyo
    • Journal of the Korean earth science society
    • /
    • v.26 no.5
    • /
    • pp.443-458
    • /
    • 2005
  • Late Quaternary deposits of the core in the western area of the Nakdong River delta consist of four sedimentary units: Unit I, II, III and IV, in ascending order, controlled by the sea-level change since the last interglacial period. Unit I unconformable overlying Cretaceous basement rocks is composed of sandy gravel and sand deposited in a fluvial channel before the first marine transgression. Unit II composed of stiff massive mud is interpreted as a shallow marine deposits formed during the last interglacial period (probably MIS 5). The development of the fissures coated with oxidized materials in the upper part of Unit II is a feature of subaerial exposure, which indicates erosional contact with the upper Unit III. Unit III is made up of soft massive mud and soft shelly massive mud deposited in a tidal flat and a inner shelf, respectively, since the Holocene transgression (about 9,000 yr BP). Unit Ⅳ consisted of soft shell bedded mud and yellowish sandy mud was deposited in the delta environments during the regression (after about 5,000 yr BP). The lower shell bedded mud was deposited in a tidal flat and the upper sandy mud was deposited in the floodplain corresponding to present site of the Nakdong River delta.

Interpretation on the subsurface velocity structure by seismic refraction survey in tunnel and slope (탄성파 굴절법 탐사를 이용한 지반 속도분포 해석-터널 및 절토 사면에의 적용 사례)

  • You Youngjune;Cho Chang Soo;Park Yong Soo;Yoo In Kol
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 1999.08a
    • /
    • pp.48-64
    • /
    • 1999
  • For quantitative evaluation of geotechnical engineering properties such as rippability and diggability, clear interpretation on the subsurface velocity structures should be preceded by figuring out top soil, weathered and soft rock layers, shape of basement, fracture zones, geologic boundary and etc. from the seismic refraction data. It is very important to set up suitable field parameters, which are the configuration of profile and its length, spacings of geophones and sources and topographic conditions, for increasing field data quality Geophone spacing of 3 to 5m is recommended in the land slope area for house land development and 5 to 10m in the tunnel site. In refraction tomography technique, the number of source points should be more than a half of available channel number of instrument, which can make topographic effect ignorable. Compared with core logging data, it is shown that the velocity range of the soil is less than 700m/s, weathered rock 700${\~}$1,200m/s, soft rock 1,200${\~}$1,800m/s. And the upper limit of P-wave velocity for rippability is estimated 1,200 to 1,800m/s in land slope area of gneiss. In case of tunnel site, it is recommended in tunnel design and construction to consider that tunnel is in contact with soft rock layer where three lineaments intersecting each other are recognized from the results of the other survey.

  • PDF

Centrifuge Model Tests on Trafficability of Very Soft Ground Treated with Geotextile and Sand Mat (토목섬유와 모래로 처리된 초연약지반의 장비주행성에 대한 원심모형실험)

  • Jun, Sang-Hyun;Lee, Jong-Ho;Yoo, Nam-Jae
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.3
    • /
    • pp.13-23
    • /
    • 2010
  • In this study, centrifuge model tests with 50 g gravitational condition were performed to evaluate the bearing capacity of very soft ground, improved by spreading geotextile and sand on the surface of ground, for the heavy machinery to be able to access. For undrained shear strength of ground model, prepared with the clay sampled from the field, being in the range of 3.1~11.7 kPa, bearing capacity tests were performed with the model footing and the loading system built to simulate the heavy machinery on the ground model treated with geotextile and sand. Test results were compared with theoretically and numerically evaluated ones. Test results about load-settlement curves showed that the bearing capacity increases with the increase of the undrained shear strength of ground. Punching shear or local shear failure was also observed. For a relatively low undrained shear strength of ground, settlement behavior is found to be crucial to evaluating the trafficability of machinery whereas bearing capacity becomes a dominant factor with the increase of undrained shear strength of ground. The method for assessing the bearing capacity of the ground related to trafficability of machinery is presented by acquiring the regression relationship between the contact pressure of machinery and settlements using load-settlement curves with the change of the undrained shear strength. Furthermore, results of numerical analyses about load-settlement relation are in relatively good agreement with those of centrifuge model test.

A Study on Object Attachment in Infant and Early Childhood(I) (유아의 대물애착현상에 관한 연구(I))

  • 서영숙
    • Journal of the Korean Home Economics Association
    • /
    • v.17 no.1
    • /
    • pp.45-55
    • /
    • 1979
  • The purpose of this study is to investigate to what extent and how the infant's Object Attachment occurs. For this purpose, 28 mothers with their infants showing or having shown this phenomenon were interviewed. They were selected by the whole scale smpling method from 310 household -wives living at a delux Apt. in Seoul. The results are summarized as follows : 1. About 27% of the infants aged between 6 months and 6 years turned out to show this phenomenon. 2. Qulits, bed clothes, pillows and blankets, which infants have been closely contacted since their babyhood, were the major source of attachment objects. In general, these objects were proved to have soft, wasm, smooth, and glassy tactile sensation. 3.This phenomenon, in average, appeared since 13 months after birth, About 50% of the whole began to show this phenomenon between 9 and 14 month after birth. 4. Half of the infants didn't show a change of attachment strength, but as for the other half, the attachment strength increased after one year of age, and decreased after three years of age, as the social period commenced. 5. Infants needed attachment objects especially when they were driven by sleep, sense of emptiness, and monotonous or boring feeling. 6. There were little difference between Object Attachment behavior and motherinfant attachment behavior except "babbling", "using her as a base for exploration". Those behaviors did not appear in Object Attachment. 7. mothers said that their children's attachment objects played the role of substitute mother, pacificater, warmer, friend , etc. And they attributed this phenomenon's appearance to lack their physical contact with, ocnstant and warm care toward, their children or bottle feeding.

  • PDF

CLINICAL APPLICATION OF ARGON LASER IN PEDIATRIC DENTISTRY (아르곤 레이저의 소아치과에서의 임상적 적용)

  • Lee, Mi-Na;Lee, Sang-Hoon;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.1
    • /
    • pp.139-147
    • /
    • 1997
  • Argon laser used in this case report, is special in having two wavelength of 488, 514nm blue-green visible light spectrum. Blue light is used for composite resin polymerization and caries detection. Green light is used for soft tissue surgery and coagulation. Maximum absorption of this laser light occurs in red pigmentation such as hemoglobin. The argon laser may be well-suited for selective destruction of blood clots and hemangioma with minimal damage to adjacent tissues. Argon laser light penetrates tissue to the 1 mm depth, so its thermal intensity is lower than $CO_2$ laser light. Also, due to its short wavelength it can be focused in a small spot and even single gene can be excised by this laser and microscopy. After applicating argon laser to 4 patient for surgical procedure and to 1 patient for curing the composite resin, following results were obtained. 1. Improved visibility were gained due to hemostasis and no specific technique were needed according to easy recontouring of the tissue. 2. Ability to use by contact mode, tactile sense was superior but tissue dragability and accumulation of tissue on the tip needed sweeping motion. 3. Additive local anesthetic procedure was needed. 4. No suture and less curing time reduced chair time, this made argon laser available in pediatric dentistry.

  • PDF

Cultural Exchange and Its Externalities on Korea-Africa Relations: How Does the Korean Wave Affect the Perception and Purchasing Behavior of African Consumers?

  • Ochieng, Haggai Kennedy;Kim, Sungsoo
    • East Asian Economic Review
    • /
    • v.23 no.4
    • /
    • pp.381-407
    • /
    • 2019
  • The Korean wave has become a global phenomenon whose effect has been widely studied in Asia, Europe and the US. However the presumption of cultural distance makes it appear unlikely that the Korean wave could gain traction among African consumers of cultural products. As such, a dearth of evidence exists on the effects of the wave in Africa. This paper examines the effect of the wave in East African countries employing both descriptive and Probit model analyses. The results show that, contrary to conventional beliefs, most Africans surveyed perceive value proximity with Korea through the values conveyed in Korean dramas, movies and music. Confucius values, such as filial piety, family love and respect for the elderly are the most appealing to the East African audience. Importantly, contact with Korean wave contents contributes to the respondents' disposition to form favorable attitude towards Korea. The African consumers of Korea's cultural products are equally likely to purchase other Korean commercial products. These results remotely suggest that Hallyu may be a tool for advancing Korea's soft power towards Africa and could generate positive economic externalities.

Anatomy and Biomechanics of the Patellofemoral Joint (슬개대퇴관절의 해부학과 생체역학에 관한 문헌적 고찰)

  • Choi, Byung-Ok
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.2
    • /
    • pp.935-944
    • /
    • 2001
  • The patellofemoral pint is formed by the articulation of the patella and femoral condyles in the trochlear groove. The complexity of the patellofemoral pint is magnified by the fact that the tibiofemoral pint works in conjunction with the patellofemoral pint. Additionally, other pints such as the subtalar pint., hip and sacroiliac pints indirectly contribute to the function of the patellofemoral pint. This pint has little bony stability, Soft tissue surrounds the pint to increase stability. The patellofemoral pint increases the mechanical advantage of the quadriceps muscles and resists mechanical loading. In patellofemoral dysfunction, patellofemoral contact pattern is disrupted. leading to excessive compression at the pint. When you treat the patellofemoral dysfunction, you should evaluate anatomic and biomechanic components and find factors of patellofemoral dysfunction. Hamstring tightness. weakness of VMO and tightness of lateral retinaculum lead to flexed knee and abnormal patella tracking and patellofemoral pint reaction force and patellofemoral dysfunction. A through understanding of the anatomy and biomechanics may assist the clinician in the recognition and treatment of patients with patellofemoral pain. Therefore physical therapists should apply modality as well as therapeutic exercise, stretching and strengthening. In this paper, I will discuss the germane anatomical structures and biomechanics of the patellofemoral pint.

  • PDF

Reconstruction of the Extremity Injury using by Free Rectus Abdoninis Muscle or Myocutaneous Flap (유리 복직근 및 복직근피판술을 이용한 사지의 재건술)

  • Ahn, Ki-Young;Jang, Kyoung-Soo;Han, Dong-Gil
    • Archives of Reconstructive Microsurgery
    • /
    • v.4 no.1
    • /
    • pp.23-32
    • /
    • 1995
  • Severe upper and lower extremity trauma may result in soft tissue loss with exposed bone and the subsequence of risk of chronic osteomyelitis or malunion of fracture fragments. Such injuries present a major reconstructive problem. But Since the introduction of microsugical technique, free muscle and myocutaneous flaps were employed to provide coverage of severely injured defects. Since Tai and Hasegawa(1974) first reported a breast reconstruction using by rectus abdominis myocuraneous flap, the free rectus myocutaneous flap has been widely employed for breast reconstuction, head and neck reconstruction, and extremity reconstruction in these days. The authors present their successful experience with free rectus abdominis muscle and rectus abdominis myocutaneous flaps for upper and low extremity reconstruction. From Nov. 94, to May 95, Five cases of severely injured extremites due to trauma or contact burn were treated with free rectus abdominis muscle flap or free rectus abdominis myocutaneous flap. All flaps except 1 case were survived without severe complications. As free muscle or myocutaneous flap, the free rectus abdominis flap has the advantages of a reliable pedicle, easy dissection, and an acceptable donor site, so it seems logical to apply the free rectus abdominis flap to apply in upper and lower extremity reconstruction.

  • PDF

Lubricating Properties on Tribo-Coating of Soft Metals in Ultra High Vacuum (초고진공중에서 연질금속의 Tribo-Coating에 관한 윤활특성)

  • 김형자;전태옥;가등건가
    • Tribology and Lubricants
    • /
    • v.10 no.3
    • /
    • pp.18-28
    • /
    • 1994
  • Sliding friction between a spherical pin of 8mm in diameter and flat (disk) substrates coated with vacuum-deposited thin film was measured under ultra high vacuum pressure for various materials, various rates of film supply (8~210 nm/min), various sliding velocities (1.5~67.0 mm/s). It was found that the most effective lubrication was obtained when the adhesion between $Si_3N_4$ pin and SUS440C disk was high and that between $Si_3N_4$ pin and $Si_3N_4$ disk was low. When In film was used as a lubricant between $Si_3N_4$ pin and stainless steel disk, the friction coefficient had a value as low as 0.04. In this case, the normal load W and the sliding speed V were expressed as 10N and 24 mm/s for $10^{-6}Pa$. The dependence of $\mu$ on the thickness h of the Ag film, which was used as a lubricant between $Si_3N_4$ pin and SUS440C (Q) disk was expressed as $\mu$=0.12 for W=10N and V=24mm/s when the film was thicker than 100nm. A brief discussion on these relations is presented from the viewpoint of the real contact area.