• 제목/요약/키워드: Soft Surface

검색결과 970건 처리시간 0.025초

지면환경이 크로스핏 선수의 프론트 스쿼트에 미치는 영향 (Effect of Surface Environment on Front Squat of Crossfit Athletes)

  • Jang, Yootae;Yoon, Sukhoon
    • 한국운동역학회지
    • /
    • 제32권2호
    • /
    • pp.49-55
    • /
    • 2022
  • Objective: This study aims to verify the front squat motions using by two different surfaces, thereby elucidating the grounds for effective training environment that can minimize the risk of injury. Method: Total of 10 healthy male crossfit athletes were recruited for this study (age: 32.30 ± 3.05 yrs., height: 173.70 ± 5.12 cm, body mass: 82.40 ± 6.31 kg, 1RM: 160 ± 13.80 kg). All participants are those who know how to do front squats well with more than five years of crossfit athlete experience. All participants have sufficient experience in front squats on two types of surface which are soft surface (SS) and hard surface (HS). In each surface, participant perform 10reps of the front squat with 80% of the pre-measured 1RM. A 3-dimensional motion analysis with 8 infrared cameras and 2 channels of EMG was performed in this study. Paired sample t-test was used for statistical verification between two surfaces. The significant level was set at α=.05. Results: The significantly decreased rectus femoris muscle activation was found in SS compared with that of HS on phase 1 (p<.05). Also, ROM of ankle joint was significantly increased in the SS compare with that of HS on phase 1 (p<.05). The muscle activity ratio of gluteus maximus/rectus femoris showed a significant difference only in SS compared with that of HS on phase 1 (p<.05). Conclusion: In conclusion, Korean crossfit boxes should consider the use of hard surface, which has a relatively less risk of injury than soft surface, in selecting flooring materials. For the Crossfit athletes, they are also considered appropriate to train on a relatively hard surface.

소프트닙 캘린더의 닙 압력 프로파일 평가와 닙 내 열전달 현상에 대한 해석 (Evaluation of the Nip Pressure Profile and Analysis of Heat Transfer in Soft Nip Calender)

  • 이사용;이학래;박선규
    • 펄프종이기술
    • /
    • 제32권2호
    • /
    • pp.26-34
    • /
    • 2000
  • Understanding the nip geometry and heat transfer phenomena of soft nip calenders, which has been used in the production of newsprint and coated papers for many years, is very important since improper setting of soft nip calendering conditions causes deterioration of paper quality and productivity. In this study theoretical analysis on nip pressure and heat transfer phenomena in the nip of soft nip calenders has been made. The variables examined were calendering pressure, surface temperature of the heating roll, nip residence time and ingoing sheet moisture, By measuring nip widths and maximum nip pressure with Prescale film at a normal temperature, accurate line load has been obtained. With this line load, nip pressures at different temperature and nip widths were calculated. Results showed that as temperature increased, nip widths increased and nip pressures decreased. Equations derived for the heat conduction phenomena in soft nip calender nip were derived based on the semi-infinite plate and finite difference method and were used for the analysis of heat transfer within the nip. Temperature profiles in z-direction of paper within the nip were obtained. Finite difference method allowed more accurate analysis of the heat transfer in the calender nip. In this study newsprint and coated paper were considered as a single plate and two-layer plate consisted of sheet and coating layers, respectively. Heat trans-fer to paper increased as heated roll surface temperature and nip residence time were increased.

  • PDF

Plantar Soft-tissue Stress states in standing: a Three-Dimensional Finite Element Foot Modeling Study

  • Chen, Wen-Ming;Lee, Peter Vee-Sin;Lee, Tae-Yong
    • 한국운동역학회지
    • /
    • 제19권2호
    • /
    • pp.197-204
    • /
    • 2009
  • It bas been hypothesized that foot ulceration might be internally initiated. Current instruments which merely allow superficial estimate of plantar loading acting on the foot, severely limit the scope of many biomechanical/clinical studies on this issue. Recent studies have suggested that peak plantar pressure may be only 65% specific for the development of ulceration. These limitations are at least partially due to surface pressures not being representative of the complex mechanical stress developed inside the subcutaneous plantar soft-tissue, which are potentially more relevant for tissue breakdown. This study established a three-dimensional and nonlinear finite element model of a human foot complex with comprehensive skeletal and soft-tissue components capable of predicting both the external and internal stresses and deformations of the foot. The model was validated by experimental data of subject-specific plantar foot pressure measures. The stress analysis indicated the internal stresses doses were site-dependent and the observation found a change between 1.5 to 4.5 times the external stresses on the foot plantar surface. The results yielded insights into the internal loading conditions of the plantar soft-tissue, which is important in enhancing our knowledge on the causes of foot ulceration and related stress-induced tissue breakdown in diabetic foot.

A Development of High Power Activated Carbon Using the KOH Activation of Soft Carbon Series Cokes

  • Kim, Jung-Ae;Park, In-Soo;Seo, Ji-Hye;Lee, Jung-Joon
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권2호
    • /
    • pp.81-86
    • /
    • 2014
  • The process parameter in optimized KOH alkali activation of soft carbon series coke material in high purity was set with DOE experiments design. The activated carbon was produced by performing the activation process based on the set process parameters. The specific surface area was measured and pore size was analyzed by $N_2$ absorption method for the produced activated carbon. The surface functional group was analyzed by Boehm method and metal impurities were analyzed by XRF method. The specific surface area was increased over 2,000 $m^2/g$ as the mixing ratio of activation agent increased. The micro pores in $5{\sim}15{\AA}$ and surface functional group under 0.4 meq/g were obtained. The contents of the metal impurity in activated carbon which is the factor for reducing the electrochemical characteristics was reduced less than 100 ppm through the cleansing process optimization. The electrochemical characteristics of activated carbon in 38.5 F/g and 26.6 F/cc were checked through the impedance measuring with cyclic voltammetry scan rate in 50~300 mV/s and frequency in 10 mHz ~100 kHz. The activated carbon was made in the optimized activation process conditions of activation time in 40 minutes, mixing ratio of activation agent in 4.5 : 1.0 and heat treatment temperature over $650^{\circ}C$.

An elastoplastic bounding surface model for the cyclic undrained behaviour of saturated soft clays

  • Cheng, Xinglei;Wang, Jianhua
    • Geomechanics and Engineering
    • /
    • 제11권3호
    • /
    • pp.325-343
    • /
    • 2016
  • A total stress-based bounding surface model is developed to predict the undrained behaviour of saturated soft clays under cyclic loads based on the anisotropic hardening modulus field and bounding-surface theories. A new hardening rule is developed based on a new interpolation function of the hardening modulus that has simple mathematic expression and fewer model parameters. The evolution of hardening modulus field is described in the deviatoric stress space. It is assumed that the stress reverse points are the mapping centre points and the mapping centre moves with the variation of loading and unloading paths to describe the cyclic stress-strain hysteresis curve. In addition, by introducing a model parameter that reflects the accumulation rate and level of shear strain to the interpolation function, the cyclic shakedown and failure behaviour of soil elements with different combinations of initial and cyclic stresses can be captured. The methods to determine the model parameters using cyclic triaxial compression tests are also studied. Finally, the cyclic triaxial extension and torsional shear tests are performed. By comparing the predictions with the test results, the model can be used to describe undrained cyclic stress-strain responses of elements with different stress states for the tested clays.

디젤엔진 실린더 라이너-피스톤 링의 코팅 층 강도에 따른 마모특성 연구 (Effect of Coating Layer Hardness on the Wear Characteristics of Diesel Engine Cylinder liner-Piston Ring)

  • 장정환;김정훈;김창희;문영훈
    • 소성∙가공
    • /
    • 제17권5호
    • /
    • pp.343-349
    • /
    • 2008
  • The wear between piston ring face and cylinder liner is an extremely unpredictable and hard-to-reproduce phenomenon that significantly decreases engine performance. This study will discuss characteristics of wear between hard and soft piston ring coatings with running surface of cylinder liner. Detailed tribological analysis by using Pin-on-Disk(POD) testing machine describes the lubricity mechanism between piston ring coatings and cylinder liner at different temperature with and without oil. The effect of surface roughness of the cylinder liner on the friction coefficient and wear amount of piston ring coatings will also be analyzed. To simulate scuffing mechanism between piston ring and cylinder liner, accelerated lab testing was performed. This study will provide the data from tribological testing of hard and soft piston ring coatings against cylinder liner. Furthermore, the microstructures and morphological features of the surface and the near-surface materials during wear will be investigated. From the scuffing test by using POD testing machine, scuffing mechanisms for the soft and hard coating will be analyzed and experimentally confirmed.

X선을 이용한 표면 및 계면의 전자구조 측정방법 소개 (The introduction of X-ray spectroscopy for surface and interface electronic structures)

  • 조상완
    • 진공이야기
    • /
    • 제1권1호
    • /
    • pp.17-20
    • /
    • 2014
  • This article introduces the basic concepts of various soft X-ray spectroscopies in the study of surface and interface electronic structures. Especially, recent results of X-ray photoelectron spectroscopy experiments on organic/inorganic thin films and a lead-free solder alloys will be discussed. Soft X-ray spectroscopies to understand the chemical and electrical properties would be of broad interest in the vacuum science communities.

실리카 졸-겔 공정에 의한 연자성 복합체 분말 성형 (Compaction of Soft Magnetic Composites via Silica Sol-Gel Process)

  • 김호형;곽정근;이흥렬
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2015년도 추계학술대회 논문집
    • /
    • pp.263-263
    • /
    • 2015
  • 절연층이 코팅된 연자성복합체(Soft magnetic composites) 분말 성형 시 발생하는 밀도와 강도 저하의 문제를 개선하기 위해 금속산화물 전구체로 표면 개질된 자성분말을 성형 후 경화시키는 방법으로 분말 자심을 제조하였다. 이를 통해 공정이 단순화 되면서 자심의 물리적 내구성을 향상시킬 수 있음을 확인하였다.

  • PDF

하퇴부와 족관절 및 족부의 피부 결손에 대한 역행성 표재 비복동맥 피판을 이용한 재건의 장점 (Advantage of Distally Based Superficial Sural Artery Flap in the Soft Tissue Defect of the Lower Leg, Ankle, Foot)

  • 하대호;김상수;전철홍;김동철;최유선;김경진
    • Archives of Reconstructive Microsurgery
    • /
    • 제10권2호
    • /
    • pp.118-123
    • /
    • 2001
  • Introduction : We report advantages of distally based superficial sural artery flap in the soft tissue defect in lower leg, ankle and foot. They are easier and less complicated technique than others. Material & Method : Total 26 patients were operated and their soft tissue defect site were 10 cases of anterior tibial surface, 6 cases of Achilles tendon area, 3 cases of lateral and medial surface of tibia, 3 cases of foot dorsum surface, 3 cases of sole, 1 case of medial aspect of ankle. Average pedicle distance was 12.8 cm(range $8{\sim}21cm$) and follow up period was mean 18 months. Result : We obtained 24 cases of excellent and good results. The two cases were reported low complication rate, which were one case of skin necrosis covered full thickness skin graft, and the other case of infection. Conclusion : The advantage of distally based superficial sural artery flap in soft tissue defect are long distant pedicle, short operation time, easy elevation of pedicle, constant and reliable blood supply and good cosmetic result with thin-thickness flap.

  • PDF

Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan

  • Julie Tilly Deferm;Frank Baan;Johan Nijsink;Luc Verhamme;Thomas Maal;Gert Meijer
    • Imaging Science in Dentistry
    • /
    • 제53권1호
    • /
    • pp.21-26
    • /
    • 2023
  • Purpose: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This validation study aimed to evaluate the reproducibility of 1) intraoral scanning and 2) soft tissue-based registration of an intraoral scan with a cone-beam computed tomography (CBCT) scan for a fully edentulous upper jaw. Materials and Methods: Two observers independently performed intraoral scans of the upper jaw in 14 fully edentulous patients. The palatal vault of both surface models was aligned, and the inter-observer variability was assessed by calculating the mean inter-surface distance at the level of the alveolar crest. Additionally, a CBCT scan of all patients was obtained and a soft tissue surface model was generated using patient-specific gray values. This CBCT soft tissue model was registered with the intraoral scans of both observers, and the intraclass correlation coefficient(ICC) was calculated to evaluate the reproducibility of the registration method. Results: The mean inter-observer deviation when performing an intraoral scan of the fully edentulous upper jaw was 0.10±0.09 mm. The inter-observer agreement for the soft tissue-based registration method was excellent(ICC=0.94; 95% confidence interval, 0.81-0.98). Conclusion: Even when teeth are lacking, intraoral scanning of the jaw and soft tissue-based registration of an intraoral scan with a CBCT scan can be performed with a high degree of precision.