• Title/Summary/Keyword: Soft Surface

Search Result 970, Processing Time 0.042 seconds

A Study of Ultrastructure on attachment of Soft Contact Lens Surface of Incubated Pseudomonas aeruginosa (배양된 Pseudomonas aeruginosa의 소프트 콘택트 렌즈 표면부착에 대한 미세구조적 연구)

  • Kim, Douk Hoon;Park, Yong Tae;You, Hae Byung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.11-14
    • /
    • 2000
  • The soft contact lens was very simple technique in handling, good sensation in fitting, good effect of a beauty, and good attachment state on the cornea in physical movement. So that, the subjects have used the correct of visual acuity. If the contact lens handling have not skill, they have acquired the side effect on eye. To analysis of a study of ultrastructure on soft contact lens surface of incubated P. aeruginosa. We have observed the soft contact lens surface by SEM. We have founded the good technical method. On the method of sample process of manufacture, the best observation of samlpe tissue was $OsO_4$ postfixation and tannic acid treatment. In this case, P. aeruginosa was a rod shape and one cilia in ultrastructure and the identification was very good. But, On the process of manufacture have not used the $OsO_4$ and tannic acid treatment, this tissue sample appeared the foreign body materials and artifacts, and the identification of the P. aeruginosa was very difficult.

  • PDF

Proposed surface modeling for slip resistance of the shoe-floor interface

  • Kim, In-Ju
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1995.04a
    • /
    • pp.515-528
    • /
    • 1995
  • Slips and falls are the major causes of the pedestrian injuries in the industry and the general community throughout the world. With the awareness of these problems, the friction coefficients of the interface between floorings and footwear have been measured for the evaluation of slip resistant properties. During this measurement process, the surface texture has been shown to be substantially effective to the friction mechanism between shoe heels and floor surfaces under various types of walking environment. Roughness, either of the floor surface or shoe heels, provides the necessary drainage spaces. This roughness can be designed into the shoe heel but this is inadequate in some cases, especially a wear. Therefore, it is essential that the proper roughness for the floor surface coverings should be provided. The phenomena that observed at the interface between a sliding elastomer and a rigid contaminated floor surface are very diverse and combined mechanisms. Besides, the real surface geometry is quite complicate and the characteristics of both mating surfaces are continuously changing in the process of running-in so that a finite number of surface parameters can not provide a proper description of the complex and peculiar shoe - floor contact sliding mechanism. It is hypothesised that the interface topography changes are mainly occurred in the shoe heel surfaces, because the general property of the shoe is soft in the face of hardness compared with the floor materials This point can be idealized as sliding of a soft shoe heel over an array of wedge-shaped hard asperities of floor surface. Therefore, it is considered that a modelling for shoe - floor contact sliding mechanism is mainly depended upon the surface topography of the floor counterforce. With the model development, several surface parameters were measured and tested to choose the best describing surface parameters. As the result, the asperity peak density (APD) of the floor surface was developed as one of the best describing parameters to explain the ambiguous shoe - floor interface friction mechanism. It is concluded that the floor surface should be continuously monitored with the suitable surface parameters and kept the proper level of roughness to maintain the footwear slip resistance. This result can be applied to the initial stage of design for the floor coverings.

  • PDF

The Effect of Circle Lens and Soft Contact Lens with Identical Material in Clinical Application on the Eyes (써클 및 동일 재질 콘택트렌즈의 임상 적용시 눈에 미치는 영향)

  • Park, Sang Hee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.147-157
    • /
    • 2011
  • Purpose: The present study was conducted to investigate the actual condition of circle lens wear and the differences caused by the pigmentation in blinking rate, non-invasive tear break-up time (NIBUT), and lens surface between circle and soft contact lens wear during clinical application. Methods: Eighty subjects were surveyed to know the actual condition of wearing circle lens. Blink rate, NIBUT of 20 subjects in twenties were measured after separately wearing soft contact lens and circle lens for 5 days. Their lens surfaces were also observed by scanning electron microscope. Results: Fifty percent of circle lens wearers answered that major reason for changing circle lens was discomfort and 67% of answerers wore circle lens more than 6 hours a day. The tendency of increased blink rates in both wearers of circle and soft contact lens at 30 minutes later when tear film stabilized and 3 hour after lens wearing was shown on the 1st, 3rd and 5th day with expanding wearing time. Especially at 3 hours after lens wearing on the 3rd and 5th day, the difference of blink rates was statistically different in circle lens wear and soft contact lens wear. The NIBUTs of soft contact lens wearers and circle lens wearers were 6.0 and 3.7 secs, respectively, at 30 min later on 1st day and were significantly different. NIBUTs of soft contact lens wearers and circle lens wearers were also statistically different 3 hrs after lens wearing on the 1st day and the similar pattern of NIBUTs was shown on the 3rd and 5th day. The roughness of both surfaces in soft contact lens and front surface in circle lens was same. However, pigmented front surface of circle lens was rougher and uneven. Conclusions: As the results, the circle lens wearers might feel discomfort in clinical application since the difference in lens surface of circle lens would change lens wettability during wearing. The difference by tinting contact lens was shown from the result, which could help better wearing circle lens.

THE EFFECTS OF DIETARY CONSISTENCY ON THE TRABECULAR BONE ARCHITECTURE IN GROWING MOUSE MANDIBULAR CONDYLE : A STUDY USING MICRO-CONFUTED TOMOGRAPHY (성장 중인 쥐에서 음식물의 경도가 하악 과두의 해면골에 미치는 영향 : 미세전산화 단층촬영을 이용한 연구)

  • Youn, Seok-Hee;Lee, Sang-Dae;Kim, Jung-Wook;Lee, Sang-Hoon;Hahn, Se-Hyun;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.228-235
    • /
    • 2004
  • The development and proliferation of the mandibular condyle can be altered by changes in the biomechanical environment of the temporomandibular joint. The biomechanical loads were varied by feeding diets of different consistencies. The purpose of the present study was to determine whether changes of masticatory forces by feeding a soft diet can alter the trabecular bone morphology of the growing mouse mandibular condyle, by means of micro-computed tomography. Thirty-six female, 21 days old, C57BL/6 mice were randomly divided into two groups. Mice in the hard-diet control group were fed standard hard rodent pellets for 8 weeks. The soft-diet group mice were given soft ground diets for 8 weeks and their lower incisors were shortened by cutting with a wire cutter twice a week to reduce incision. After 8 weeks all animals were killed after they were weighed. Following sacrifice, the right mandibular condyle was removed. High spatial resolution tomography was done with a Skyscan Micro-CT 1072. Cross-sections were scanned and three-dimensional images were reconstructed from 2D sections. Morphometric and nonmetric parameters such as bone volume(BV), bone surface(BS), total volume(TV), bone volume fraction(BV/TV), surface to volume ratio(BS/BV), trabecular thickness(Tb. Th.), structure model index(SMI) and degree of anisotropy(DA) were directly determined by means of the software package at the micro-CT system. From directly determined indices the trabecular number(Tb. N.) and trabecular separation(Tb. Sp.) were calculated according to parallel plate model of Parfitt et al.. After micro-tomographic imaging, the samples were decalcified, dehydrated, embedded and sectioned for histological observation. The results were as follow: 1. The bone volume fraction, trabecular thickness(Tb. Th.) and trabecular number(Tb. N.) were significantly decreased in the soft-diet group compared with that of the control group (p<0.05). 2. The trabecular separation(Tb. Sp.) was significantly increased in the soft-diet group(p<0.05). 3. There was no significant differences in the surface to volume ratio(BS/BV), structure model index(SMI) and degree of anisotropy(DA) between the soft-diet group and hard-diet control group (p>0.05). 4. Histological sections showed that the thickness of the proliferative layer and total cartilage thickness were significantly reduced in the soft-diet group.

  • PDF

The Change of Lordosis according to Plantar Surface Compliance in Patients with Chronic Low Back Pain (만성요통환자에서 족저 접촉면의 경도에 따른 요추전만도의 변화)

  • Kong Hee-Kyung;Cho Hyun-Rae;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.4
    • /
    • pp.13-23
    • /
    • 2003
  • The purpose of this study was to evaluate the change of lordosis according to plantar surface compliance in patients with chronic low back pain. Thirty patients with chronic low back pain aged between 20 and 40 were assigned to 3 groups: control group, experimental groups (FHRS group, FSRH group). The lordosis was examined before and after adaptation with corresponding foam types. The results were as follows : 1. As the result of comparing lordosis before and after test of the control group which any change did not exist in plantar surface compliance, there was not a significant difference(p>0.05). 2. As the result of comparing lordosis before and after test of the FHRS group which forefoot part of plantar surface is hard and rear foot part is soft, there was the significant increase(p<0.05). 3. As the result of comparing lordosis before and after test of the FSRH group which forefoot part of plantar surface is soft and rear foot part is hard, there was the significant decrease(p<0.05). 4. As the result of comparing lordosis of the FHRS group and FSRH group, there was not a significant difference before test(p>0.05). But, there was a significant difference after test(p<0.05).

  • PDF

Electrochemical Study of Three Stainless Steel Alloys and Titanium Metal in Cola Soft Drinks

  • Peralta-Lopez, D.;Sotelo-Mazon, O.;Henao, J.;Porcayo-Calderon, J.;Valdez, S.;Salinas-Solano, G.;Martinez-Gomez, L.
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.294-306
    • /
    • 2017
  • Stainless steels and titanium alloys are widely used in the medical industry as replacement materials. These materials may be affected by the conditions and type of environment. In the same manner, soft drinks are widely consumed products. It is of interest for dental industry to know the behavior of medical-grade alloys when these are in contact with soft drinks, since any excessive ion release can suppose a risk for human health. In the present study, the electrochemical behavior of three stainless steel alloys and pure titanium was analyzed using three types of cola soft drinks as electrolyte. The objective of this study was to evaluate the response of these metallic materials in each type of solution (cola standard, light and zero). Different electrochemical techniques were used for the evaluation of the alloys, namely potentiodynamic polarization, linear polarization, and open-circuit potential measurements. The corrosion resistance of the stainless-steel alloys and titanium in the cola soft drinks was provided by the formation of a stable passive film formed by metal oxides. Scanning electron microscopy was used as a complementary technique to reveal corrosion phenomena at the surface of the materials evaluated.

Behavior of Variable Cross-Section Soft Ground Reinforced Foundation in Soft Grounds (연약지반에 적용된 변단면 연약지반보강기초의 거동분석)

  • Kim, Khi-Woong;Kim, Dong-Wook;Jo, Myoung-Su
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.4
    • /
    • pp.89-96
    • /
    • 2016
  • Compressive axial behavior of the variable cross-section soft ground reinforced foundation is investigated from the field load test results at ${\bigcirc}{\bigcirc}$ construction site in Incheon city. Variable cross-section soft ground reinforced foundation is a type of partial-displacement pile formed by mixing bidding material with in situ soils to obtain a rigid and strong variable cross-section column in a relatively soft ground. The foundations are usually constructed as a group; however in this study, only single foundation was installed and tested under compressive axial load on foundation head. For the comparison of the variable cross-section soft ground reinforced foundation axial behavior, behavior of typical Pretensioned spun high strength concrete (PHC) pile constructed on a relatively soft ground near the surface was analyzed. It was concluded that variable cross-section soft ground reinforced foundation efficiently resists against axial load with sufficient stiffness and strength within a considerable range of axial load magnitude.

The Influence of Charged Static Electricity on LCD Glass and Neutralization Characteristic by Soft X-ray

  • Choi, Chang-Hoon;Han, Sang-Ho;Park, Sun-Woo;Yun, Hae-Sang
    • Journal of Information Display
    • /
    • v.1 no.1
    • /
    • pp.52-58
    • /
    • 2000
  • We observed that static electricity has an influence on the etching unformity of dry etching process. When the static electricity was applied from-200[V]to-1000[V] on glass substrates, the etching rate uniformity was changed to 1.5%-15%. In this experiment, the soft X-ray to neutralize static electricity was adopted as ore of neutralization methods. As an experimental result, soft X-ray irradiation improved neutralization capability on the surface of LCD glass substrate within the short time, about 15-30sec. The difference of etching rate uniformity was below 0.5%.

  • PDF

An Experimental Study on the Roofing Waterproofing Method Combined Soft and Hard Rapid Hardening Membrane (연질 및 경질 초속경도막방수재를 복합화한 옥상노출방수공법에 관한 실험적 연구(균열 대응성))

  • Choi, Eun-Gyu;Seo, Hyun-Jae;Lee, Jung-Hun;Lee, Sun-Gyu;Song, Je-Young;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.177-178
    • /
    • 2018
  • In the case of conventional ultra-fast hardness membrane waterproofing material (polyurea, etc.), damage such as breakage or tearing occurred frequently at the time of cracking of the surface after waterproofing. In this study, it is suggested that a waterproof layer can not cope with the occurrence of cracks at the same time by applying the soft type waterproofing material of soft type at the lower part of the construction method (securing of elongation) To minimize the possibility of water resistance.

  • PDF