• 제목/요약/키워드: Sodium-cooled Fast Reactor

검색결과 154건 처리시간 0.026초

PGSFR 소듐냉각고속로 원자로용기 설계 및 구조건전성 평가 (Structural design and integrity evaluations for reactor vessel of PGSFR sodium-cooled fast reactor)

  • 구경회;김성균
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.70-77
    • /
    • 2016
  • In this paper, the structural design and integrity evaluations for a reactor vessel of PGSFR sodium-cooled fast reactor(150MWe) are carried out in compliance with ASME BPV III, Division 5 Subsection HB. The reactor vessel is designed with a direct contact of primary sodium coolant to its inner surface and has a double vessel concept enclosing by containment vessel. To assure the structural integrity for 60 years design lifetime and elevated operating temperature of $545^{\circ}C$, which can invoke creep and creep-fatigue damage, the structural integrity evaluations are carried out in compliance with the ASME code rules. The design loads considered in this evaluations are primary loads and operation thermal cycling loads of normal heat-up and cool-down. From the evaluations, the PGSFR reactor vessel satisfies the ASME code limits but it was found that there is a little design margin of creep damage for inner surface at the region of cold pool free surface.

Robust technique using magnetohydrodynamics for safety improvement in sodium-cooled fast reactor

  • Lee, Jong Hui;Park, Il Seouk
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.565-578
    • /
    • 2022
  • Among Generation IV reactors, the sodium-cooled fast reactor (SFR) is attracting attention as a system having great potential for commercial use. Gas entrainment is a thermal-hydraulic issue related to the safety problem of the reactor core in the SFR. Typically, a dipped plate or baffles are installed under the free surface to suppress gas entrainment. However, these approaches can cause gas entrainment in other locations and require many trial-and-error and verifications. In this study, a new strategy using magnetohydrodynamics to suppress gas entrainment in the SFR is proposed. In a counter-flow model, a judgment criterion of gas entrainment occurrence was developed for both water and liquid metal. Moreover, the gas entrainment can be completely suppressed by applying a magnetic field.

Remote NDT for Inspection of Reactor Vessel Components of fast Breeder Test Reactor

  • Anandapadmanaban, B.;Srinivasan, G.;Kapoor, R.P.
    • 비파괴검사학회지
    • /
    • 제23권5호
    • /
    • pp.520-525
    • /
    • 2003
  • Fast Breeder Test Reactor (FBTR) is a 40MW (thermal) / 13.2MW (electrical), Plutonium - Uranium mixed carbide fuelled, sodium cooled, loop type nuclear reactor operating at Indira Gandhi Centre for Atomic Research (IGCAR), Kalpakkam. Its main aim is to generate experience in operation of fast reactors and sodium systems and to serve as an irradiation facility for development of fuels and structural materials fur fast reactors. Nuclear reactors pose difficulties to the NDT techniques used to monitor the conditions of the internal components. Sodium cooled fast breeder reactors have their own typical difficulties in using the NDT techniques. These are due to the need for operation in aggressive environment of nuclear radiation and sodium (molten/vapour), as well as the need to maintain leak tightness of a very high order during all states of reactor operation and shutdown for fuel handling, maintenance and remote inspection. This paper discusses the following NDT techniques, which have been successfully used for the past 15 years in FBTR: (i) Periscope and Projector, (ii) Core Co-ordinate Measuring Device and, (iii) Optical fiberscope. The inspection using these techniques have given confidence for further reactor operation at high power by giving useful data on the conditions of the components inside the reactor vessel.

Dynamic data validation and reconciliation for improving the detection of sodium leakage in a sodium-cooled fast reactor

  • Sangjun Park;Jongin Yang;Jewhan Lee;Gyunyoung Heo
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1528-1539
    • /
    • 2023
  • Since the leakage of sodium in an SFR (sodium-cooled fast reactor) causes an explosion upon reaction with air and water, sodium leakages represent an important safety issue. In this study, a novel technique for improving the reliability of sodium leakage detection applying DDVR (dynamic data validation and reconciliation) is proposed and verified to resolve this technical issue. DDVR is an approach that aims to improve the accuracy of a target system in a dynamic state by minimizing random errors, such as from the uncertainty of instruments and the surrounding environment, and by eliminating gross errors, such as instrument failure, miscalibration, or aging, using the spatial redundancy of measurements in a physical model and the reliability information of the instruments. DDVR also makes it possible to estimate the state of unmeasured points. To validate this approach for supporting sodium leakage detection, this study applies experimental data from a sodium leakage detection experiment performed by the Korea Atomic Energy Research Institute. The validation results show that the reliability of sodium leakage detection is improved by cooperation between DDVR and hardware measurements. Based on these findings, technology integrating software and hardware approaches is suggested to improve the reliability of sodium leakage detection by presenting the expected true state of the system.

소듐냉각고속로 원형로 소듐-물 반응 압력완화계통 성능 해석 연구 (Investigation on Performance Analysis of Sodium-Water Reaction Pressure Relief System of Prototype Generation-IV Sodium-Cooled Fast Reactor)

  • 박선희;한지웅
    • Korean Chemical Engineering Research
    • /
    • 제57권1호
    • /
    • pp.28-41
    • /
    • 2019
  • 본 연구는 소듐냉각고속로 원형로 소듐-물 반응 압력완화계통의 성능 해석을 목적으로 한다. 증기발생기의 전열관 파단에 의한 대규모 물 누출 사고 발생 시, 증기발생기 전열관 내측의 물을 급수덤프탱크로 배출하고 전열관 외측의 소듐 및 반응생성물을 소듐덤프탱크로 배출 할 때 유체의 거동을 해석하여 계통 설계요건의 적절성을 평가하였다. 증기발생기 쉘 측의 액체와 중간열전달계통 내 소듐이 모두 배출되는데 소요되는 시간은 약 50초이고, 증기발생기 전열관 측의 급수가 모두 배출되는데 소요되는 시간은 약 2.5초로 계산되었다. 증기발생기와 중간열전달계통 내 유체가 덤프탱크로 배출되는 동안 전열관 측의 압력은 쉘 측의 압력보다 높게 유지되어 쉘 측의 소듐이 전열관 측으로 역류하는 현상은 없는 것으로 해석되었다. 본 연구의 결과는 SFR 원형로 소듐-물반응압력완화계통의 성능 평가에 대한 기초자료로 활용할 예정이다.

On the Particle Swarm Optimization of cask shielding design for a prototype Sodium-cooled Fast Reactor

  • Lim, Dong-Won;Lee, Cheol-Woo;Lim, Jae-Yong;Hartanto, Donny
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.284-292
    • /
    • 2019
  • For the continuous operation of a nuclear reactor, burnt fuel needs to be replaced with fresh fuel, where appropriate (ex-vessel) fuel handling is required. Particularly for the Sodium-cooled Fast Reactor (SFR) refueling, its process has unique challenges due to liquid sodium coolant. The ex-vessel spent fuel transportation should concern several design features such as the radiation shielding, decay-heat removal, and inert space separated from air. This paper proposes a new design optimization methodology of cask shielding to transport the spent fuel assembly in a prototype SFR for the first time. The Particle Swarm Optimization (PSO) algorithm had been applied to design trade-offs between shielding and cask weight. The cask is designed as a double-cylinder structure to block an inert sodium region from the air-cooling space. The PSO process yielded the optimum shielding thickness of 26 cm, considering the weight as well. To confirm the shielding performance, the radiation dose of spent fuel removed at its peak burnup and after 1-year cooling was calculated. Two different fuel positions located during transportation were also investigated to consider a functional disorder in a cask drive system. This study concludes the current cask design in normal operations is satisfactory in accordance with regulatory rules.

Evaluation of a Sodium-Water Reaction Event Caused by Steam Generator Tubes Break in the Prototype Generation IV Sodium-cooled Fast Reactor

  • Ahn, Sang June;Ha, Kwi-Seok;Chang, Won-Pyo;Kang, Seok Hun;Lee, Kwi Lim;Choi, Chi-Woong;Lee, Seung Won;Yoo, Jin;Jeong, Jae-Ho;Jeong, Taekyeong
    • Nuclear Engineering and Technology
    • /
    • 제48권4호
    • /
    • pp.952-964
    • /
    • 2016
  • The prototype generation IV sodium-cooled fast reactor (PGSFR) has been developed by the Korea Atomic Energy Research Institute. This reactor uses sodium as a reactor coolant to transfer the core heat energy to the turbine. Sodium has chemical characteristics that allow it to violently react with materials such as a water or steam. When a sodium-water reaction (SWR) occurs due to leakage or breakage of steam generator tubes, high-pressure waves and corrosive reaction products are produced, which threaten the structural integrity of the components of the intermediate heat-transfer system (IHTS) and the safety of the primary heat-transfer system (PHTS). In the PGSFR, SWR events are included in the design-basis event. This event should be analyzed from the viewpoint of the integrities of the IHTS and fuel rods. To evaluate the integrity of the IHTS based on the consequences of the SWR, the behaviors of the generated high-pressure waves are analyzed at the major positions of a failed IHTS loop using a sodium-water advanced analysis method-II code. The integrity of the fuel rods must be consistently maintained below the safety acceptance criteria to avoid the consequences of the SWR. The integrity of the PHTS is evaluated using the multidimensional analysis of reactor safety-liquid metal reactor code to model the whole plant.

Seismic modeling and analysis for sodium-cooled fast reactor

  • Koo, Gyeong-Hoi;Kim, Suk-Hoon;Kim, Jong-Bum
    • Structural Engineering and Mechanics
    • /
    • 제43권4호
    • /
    • pp.475-502
    • /
    • 2012
  • In this paper, the seismic analysis modeling technologies for sodium-cooled fast reactor (SFR) are presented with detailed descriptions for each structure, system and component (SSC) model. The complicated reactor system of pool type SFR, which is composed of the reactor vessel, internal structures, intermediate heat exchangers, primary pumps, core assemblies, and core support structures, is mathematically described with simple stick models which can represent fundamental frequencies of SSC. To do this, detailed finite element analyses were carried out to identify fundamental beam frequencies with consideration of fluid added mass effects caused by primary sodium coolant contained in the reactor vessel. The calculation of fluid added masses is performed by detailed finite element analyses using FAMD computer program and the results are discussed in terms of the ways to be considered in a seismic modeling. Based on the results of seismic time history analyses for both seismic isolation and non-isolation design, the functional requirements for relative deflections are discussed, and the design floor response spectra are proposed that can be used for subsystem seismic design.

소듐냉각고속로 원형로 소듐-물 반응 압력완화계통의 배출배관 설계요건 연구 (Investigation on Design Requirements of Vent Lines for Sodium-Water Reaction Pressure Relief System of Prototype Generation-IV Sodium-Cooled Fast Reactor)

  • 박선희;한지웅
    • Korean Chemical Engineering Research
    • /
    • 제56권3호
    • /
    • pp.388-403
    • /
    • 2018
  • 본 연구는 소듐냉각고속로 원형로 소듐-물 반응 압력완화계통의 소듐, 물, 가스 배출배관 설계에 필요한 요건 도출을 목적으로 한다. 증기발생기의 전열관 파단에 의한 대규모 물 누출 사고 발생 시, 증기발생기 전열관 측의 물과 전열관 외측의 소듐 및 반응생성물을 물배출조와 소듐배출조로 신속하게 배출하기 위해 증기발생기의 소듐 배출배관 파열판 면적, 소듐배출조의 가스 방출배관 직경, 물배출조의 기체 방출배관 직경, 증기발생기의 물 배출배관 직경 등을 설정하기 위한 계산을 수행하였다. 이를 바탕으로 대규모 물 누출 사고 발생 시 증기발생기 내 유체 배출 소요시간 및 압력거동 해석을 수행하였고, 증기발생기 물 배출배관 격리밸브의 차단 설정압력 등의 설계인자를 도출하였다. 본 연구에서 도출된 설계인자들은 소듐냉각고속로 원형로 소듐-물 반응 압력완화계통 설계에 기초자료로 활용할 예정이다.

FEASIBILITY OF AN INTEGRATED STEAM GENERATOR SYSTEM IN A SODIUM-COOLED FAST REACTOR SUBJECTED TO ELEVATED TEMPERATURE SERVICES

  • Koo, Gyeong-Hoi;Lee, Jae-Han
    • Nuclear Engineering and Technology
    • /
    • 제41권8호
    • /
    • pp.1115-1126
    • /
    • 2009
  • As one of the ways to enhance the economical features in sodium-cooled fast reactor development, the concept of an integrated steam generator and pump system (ISGPS) is proposed from a structural point of view. And the related intermediate heat transfer system (IHTS) piping layout compatible with the ISGPS is described in detail. To assure the creep design lifetime of 60 years, the structural integrity is investigated through high temperature structural evaluation procedures by the SIE ASME-NH computer code, which implements the ASME-NH design rules. From the results of this study, it is found that the proposed ISGPS concept is feasible and applicable to a commercial SFR design.