• Title/Summary/Keyword: Socket Joint

Search Result 38, Processing Time 0.024 seconds

Influence on amputee gait by the ankle joint alignment (발목관절 조절각도가 절단환자의 보행에 미치는 영향)

  • Kim, Y.H.;Yang, G.T.;Lim, S.H.;Chang, Y.H.;Mun, M.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.369-372
    • /
    • 1997
  • Socket pressure distributions with gait analyses of a transfemoral and a transtibial prostheses were measured in order to assess an optimal socket fitting and unction. Ankle joint was aligned by the neutral and the dorsi/plantar flexed positions. Compared to dorsi and plantar flexed positions of ankle joint, cadence and walking speed increased with the neutral ankle joint alignment. Other gait parameters were close to the normative data with the neutral ankle joint alignment. For the transfemoral amputee, dorsiflexed alignment of the ankle joint created high pressure on the lateral aspect of the socket, on the other hand, plantarflexed alignment resulted in increased pressure on the medial aspect of the socket. For the transtibial amputee, dorsiflexed alignment of the ankle resulted in high pressure on the antero-lateral aspect of the socket during mid-stance, but plantarflexion of the ankle joint showed slight increases in pressure at the same location in the socket. The present study clearly demonstrated that malalignment of a prosthesis results in localized increasing pressure within the socket. Proper alignment of the prosthesis is required in order to acquire an appropriate socket-limb interface as well as the proper gait.

  • PDF

Broström Procedure and Fibula Periosteal Turn Down Augmentation for the Ball-and-Socket Ankle Accompanying Lateral Ankle Instability: A Case Report (Broström 술식과 비골 골막 젖힘 보강술로 치료한 구상 발목관절에 동반된 족근관절 외측 불안정증: 증례 보고)

  • Shin, Woojin;Cho, Hong Man;Park, Jiyeon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.24 no.2
    • /
    • pp.98-101
    • /
    • 2020
  • We report on the case of a patient with chronic instability of the ball-and-socket ankle joint. The patient, a 21-year-old male, was diagnosed 10 years previously with chronic instability of the ball-and-socket ankle joint. He underwent Broström procedure and augmentation using a periosteal turn down from the fibula for this chronic instability despite having received conservative treatment since the diagnosis. After the procedure, the clinical symptoms of ankle instability were improved and the patient is being periodically followed-up. We report on this case of using a Broström procedure as a treatment option for patients with instability of the ball-and-socket ankle joint with normal range of foot and normal ankle joint alignment without damage in the joint and cartilage.

A Study on Safe Permanent Joint Type Multiple Socket-Outlets Development without Soldering Crimped Connection (안전형 비납땜 틀고정 영구 접속형 멀티콘센트 개발에 관한 연구)

  • Cho, Won-Seok;Lee, Wi-Ro
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.47-54
    • /
    • 2015
  • Normally, multiple socket-outlet is manufactured with soldered, welded permanent connection (termination). Because this procedure is very non-environmental and requires many labor forces, many companies skip this process. To solve this these problems, this research had to design permanent joint type multiple socket-outlet, develop safer multiple socket-outlet than is sold in markets. Progressing this research, we took 3 steps. First, we had to design device for fixing a frame suitable for multiple socket-outlet. Second, this multiple socket-outlet must pass fundamental standards through international standard (IEC 60884-1) and Korean standard (K 60884-1) tests. Third, it had to pass both several mechanical and electrical tests which is more strict than fundamental standards and vibration and impact tests following KS standards for enhancing its safety. After finishing 3 steps, we could obtain objective and fair data, develop environmental permanent joint type multiple socket-outlet without soldering crimped connection.

Nonunion in Bilateral Ball and Socket Ankle Joint (양측성 절구공이 족관절에서의 불유합 -1예 보고-)

  • Park, Hong-Gi;Lee, Kyung-Chan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.2
    • /
    • pp.231-233
    • /
    • 2005
  • Ball-and-socket deformity of the ankle joint is a rare entity that is usually associated with inequality of leg length, fibular hyperplasia, coalition of the ankle, and ray deficiency. Etiology is unknown, congenital itself or secondary to congenital conditions in the ankle. Nonunion of medial malleolar is rare in bilateral ball and socket ankle joint without lower leg deformity. We report upon this case, and include brief reviwe of the literature.

  • PDF

Influence on Amputee Gait by the Ankle Joint Alignment (발목관절 조절각도가 절단환자의 보행에 미치는 영향)

  • Jang, Yun-Hui;Yang, Gil-Tae;Im, Song-Hak;Mun, Mu-Seong;Kim, Yeong-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.403-416
    • /
    • 1998
  • Socket pressure distributions with gait analysis of a trnsfemoral and a transtibial prostheses were measured in order to assess an optimal socket fitting and function. Ankle joint was aligned by the neutral and the dorsi/plantar flexed positions. Compared to dorsi and plantar flexed positions of ankle joint, cadence and walking speed increased with the neutral ankle joint alignment. Other gait parameters were close to the normative data with the neutral ankle joint alignment. For the transfemoral amputee, dorsiflexed alignment of the ankle joint created high pressure on the lateral aspect of the socket, on the other hand, plantarflexed alignment resulted in increased pressure on the medial aspect of the socket. For the transtibial amputee, dorsiflexed alignment of the ankle resulted in high pressure on the antero-lateral aspect of the socket during mid-stance, but apltarflexion of the ankle joint showed slight increases in pressure at the same location in the socket. The present study clearly demonstarted that malalignment of a prosthesis results in localized increasesing pressure within the socket. Proper slignment of the prosthesis is required in order to acquire an appropriate socket-limb interface as well as the proper gait.

  • PDF

Structural Performance Evaluation of Prestressed Concrete Trapezoidal Girders Using Socket Joint System (소켓연결 방식을 이용한 프리스트레스트 콘크리트 제형 거더의 구조성능 평가)

  • Shim, Won-Bo;Min, Kyung-Hwan;Choi, Hong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7244-7249
    • /
    • 2015
  • In this study, in order to asses the structural performance of trapezoidal PSC girder using a socket joint system and it is possible to calculate the optimized cross-section of the web element tests were carried out for each specimens. we conducted a socket joint performance test, web bending and shear performance tests and all tests were performed at 4 point loading method. The initial crack load of socket joint specimen was significantly lower than the reference specimen but post peak behavior was no significant differences. And the length of the loop joint of the reinforcing bars had no significant effect on the maximum load. As a web shear tests, to obtain a maximum load of the specimen has a prestressing rod reinforced at tension side. As a web flexural tests, to obtain higher diagonal cracking load in specimen of reinforced using prestressing rod than reference specimen.

Intelligent High-Precision Warm Forging Process (지능형 고정밀 온간단조 기술)

  • Lee J. Y;Bae M. H.;Jeong S. C.;Seo S. Y.;Lee Y. S.;Lee J. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.10a
    • /
    • pp.321-325
    • /
    • 2001
  • This paper describes the basic structure of high-precision warm forging process for ball joint socket. If this research is successfully finished, We expect that productivity improvement, reduction of material cost and machining process, and cost down than conventional warm forging process.

  • PDF

A Study on Life Estimation of a Forging Die (단조 금형의 수명 평가에 관한 연구)

  • Choi, C.H.;Kim, Y.J.
    • Transactions of Materials Processing
    • /
    • v.16 no.6
    • /
    • pp.479-487
    • /
    • 2007
  • Die life is generally estimated taking failure life and wear amount into consideration. In this study, the forging die life was investigated considering both of these two factors. The fatigue life prediction for the die was performed using the stress-life method, i.e. Goodman's and Gerber's equations. The Archard's wear model was used in the wear life simulation. These die life prediction techniques were applied to the die used in the forging process of the socket ball joint of a transportation system. A rigid-plastic finite element analysis for the die forging process of the socket ball was carried out and also the elastic stress analysis for the die set was performed in order to get basic data for the die fatigue life prediction. The wear volume of the die was measured using a 3-dimensional measurement apparatus. The simulation results were relatively in good agreement with the experimental measurements.

Seismic performance of precast assembled bridge piers with hybrid connection

  • Shuang, Zou;Heisha, Wenliuhan;Yanhui, Liu;Zhipeng, Zhai;Chongbin, Zhang
    • Structural Engineering and Mechanics
    • /
    • v.85 no.3
    • /
    • pp.407-417
    • /
    • 2023
  • Precast assembled bridge piers with hybrid connection (PASP) use both tendons and socket connections. To study the seismic performance of PASP, a full-scale in-situ test was performed based on an actual bridge project. The elastic-plastic fiber model of PASP was established using finite element software, and numerical analyses were performed to study the influence of prestress degree and socket depth on the PASP seismic performance. The results show that the typical failure mode of PASP under horizontal load is bending failure dominated by concrete cracking at the joint between the column and cushion cap. The cracking of the pier concrete and opening of joints depend on the prestress degree and socket depth. The prestressing tendons and socket connection can provide enough ductility, strength, restoration capability, and bending strength under small horizontal displacements. Although the bearing capacity and post yield stiffness of the pier can be improved to some extent by increasing the prestressing force, ductility is reduced, and residual deformation is increased. Overall, there are reasonable minimum socket depths to ensure the reliability of the socket connection.