• Title/Summary/Keyword: SoC System

Search Result 2,846, Processing Time 0.035 seconds

Magnesium-induced Relaxation in Rat Aorta (Magnesium에 의한 흰쥐 대동맥 이완)

  • Oh, Sung-suck;Lee, Sang-woo;Kang, Hyung-sub;Kim, Jin-shang
    • Korean Journal of Veterinary Research
    • /
    • v.43 no.3
    • /
    • pp.373-382
    • /
    • 2003
  • Magnesium ion ($Mg^{2+}$) is a vasodilator, but little is known about its mechanism of action on vascular system. In vitro, extracellular magnesium sulfate ($MgSO_4$) produced relaxation in phenylephrine (PE) or high KCl-precontracted isolated rat thorocic aorta with (+E) or without (-E) endothelium in a concentration-dependent manner. The $MgSO_4$-induced relaxations were not affected by removal of the endothelium. Pretreatment of +E or -E aortic rings with nitric oxide synthase (NOS) inhibitors ($20{\mu}M$ L-NNA, $100{\mu}M$ L-NAME, $1{\mu}M$ dexamethasone and $400{\mu}M$ aminoguanidine), cyclooxygenase inhibitor ($10{\mu}M$ indomethacin), guanylate cyclase inhibitors ($10{\mu}M$ ODQ and $30{\mu}M$ methylene blue) and $Ca^{2+}$ transport blocker ($10{\mu}M$ ryanodine) did not affect the relaxant effects of $MgSO_4$. $Ca^{2+}$ channel blockers ($0.3{\mu}M$ nifedipine and $0.5{\mu}M$ veropamil) completely decreased the relaxant effects of $MgSO_4$ in +E and -E aortic rings. However, in $Ca^{2+}$-free medium, $MgSO_4$-induced vasorelaxation was potentiated and this response was inhibited by nifedipine. Protein kinase C (PKC) inhibitors ($1.0{\mu}M$ staurosporine, $0.5{\mu}M$ tamoxifen and $0.1{\mu}M$ H7) or PLC inhibitor ($100{\mu}M$ NCDC) markedly decreased the relaxant effects of $MgSO_4$ in +E and -E aortic rings. In vivo, infusion of $MgSO_4$ elicited significant decreases in arterial blood pressure. After intravenous injection of nifedipine ($150{\mu}g/kg$) and NCDC (3 mg/kg), infusion of $MgSO_4$ inhibited the $MgSO_4$-lowered blood pressure markedly. However, after introvenous injection of saponin (15 mg/kg), L-NNA (3 mg/kg), L-NAME (5 mg/kg), indomethacin (2 mg/kg), methylene blue (15 mg/kg) and aminoguanidine (10 mg/kg) failed to inhibit it. These results suggest that endothelial NQ-cGMP or prostaglandin pathway is not involved in vasorelaxant or hypotensive action of $Mg^{2+}$ and that these effects are due to the inhibitory action of $Mg^{2+}$ on the $Ca^{2+}$ channel or PLC-PKC pathway, and are due to the competitive influx of $Mg^{2+}$ and $Ca^{2+}$ through the $Ca^{2+}$ channel.

The Study on The Military Intelligence Architecture Framework by Business Process Reengineering(Centering on the C4I Operational Architecture for the ground tactical C4I system) (군 정보체계 종합구조 작성에 대한 BPR 적용 연구(지상전술 C4I 체계의 운용 구조 작성을 중심으로))

  • 박종운;이문우;박두영;장종환
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.6
    • /
    • pp.747-758
    • /
    • 2001
  • While developing the military intelligence systems, inter-operation problems which are even existed in the advanced countries must be secured. So we intend to contribute the development of concerned theories by suggesting the process and results of the operational architecture(OA) in C4ISR architecture framework that U.S. military researched and setup based on C4ISR architecture framework theory and BPR methodology.

  • PDF

Utilization of Ready-mixed Concrete Recycling Water Mixed with Hot-rolled Slag Containing C12A7 and Application Characteristics of Cement Mortar (C12A7을 함유한 열연슬래그를 혼입한 레미콘 회수수 활용 및 시멘트 모르타르의 적용 특성)

  • Kim, Young-Yeop;Lee, Han-Seung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.1
    • /
    • pp.92-99
    • /
    • 2021
  • CaO-based by-products composed of CaO, SO3, Al2O3, etc. are generally used as raw materials for CaO compounds. When applied to the recovered water of ready-mixed concrete, the hydration reaction of the powder material is accelerated and concrete performance can be improved. In this study, activated sludge was prepared to apply to the recovered water of ready-mixed concrete by mixing CaO-based hot-rolled slag(C12A7) in the recycling water of ready-m ixed concrete. Cem ent paste setting time and mortar compressive strength performance tests confirmed the effect on the hydration reaction. Therefore, the possibility of concrete application using activated sludge was confirmed.

The PWM Speed Control of DC servo Motor for Movable Robot Drives (자립형 이동로보트 구동을 위한 DC서보전동기 PWM속도제어)

  • Hong, S.I.;Kim, C.J.;Jo, C.J.;Kim, C.W.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1185-1187
    • /
    • 1992
  • In this paper, PWM control is applied to the microprcessor-based adjustable speed dc motor drives. The motor drive system is composed of phase locked loop. Main drive circuit of the system is consisted of H-type bridge with switching transistors. PWM drive circuit is linearized by adding flywheeling diodes. And also. We study the optimum PWM data and period time so that it hase a nearly liner relationship between current and torque.

  • PDF

Automated command generation for satellite control

  • Mo, Hee-Sook;Kim, Jae-Hoon;Lee, Ho-Jin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.380-383
    • /
    • 1995
  • Since the generation and transmission of telecommand in satellite monitoring and control system depend on the decisions of operators, it is possible that operators with different levels of knowledge may generate different telecommands in the same situation. Because of this reason, automation technology of satellite operation is being researched and developed to minimize the decision error due to the operator's lack of experience. This paper suggests a method of automated satellite control, which generates telecommands automatically using the knowledge of satellite subsystem engineers or specialists for the ground system. This method provides safe satellite operation and expansion of satellite life time by automatic generation of the telecommands, so that the operator's interrupt is minimized which provides the efficient satellite control.

  • PDF

A Double Band Hysteresis Current Control Method (이중밴드 히스테리시스 전류 제어 방식)

  • Oh W.H.;Yoo C.H.;Shin E.C.;Park S.M.;Noh H.Y.;Yoo J.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.579-583
    • /
    • 2003
  • Hysteresis controllers are intrinsically robust to system parameters, exhibit very high dynamic response and are suitable for simple implementation. But the current control using a conventional hysteresis controller has the disadvantage that high switching frequency may happen due to lack of coordination among individual hysteresis controllers of three phases. This will of course increase the switching loss. In addition, the current error is not strictly limited. So, in this paper to reduce the switching frequency, a double band hysteresis current controller is proposed. The presented control system was tested with digital simulation in the Borland C++ program and demonstrate the advantage of proposed hysteresis current controller.

  • PDF

A Design on the Rhino XR-3 Robot Controller Using TMS320c31 (TMS320c31을 이용한 Rhino XR-3 로봇 제어기 설계)

  • Park, Won-Ki;Lee, Kwae-Hi
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.564-566
    • /
    • 1998
  • A robot manipulator is a nonlinear time varying MIMO system. Therefore, when a robot manipulator operates at high speeds, the performance of pursuing its trace becomes worse due to the increased nonlinearity of system. Several nonlinear control methods are introduced for solving this problem. But, these methods need a large amount of calculations, so it is necessary to use the controller equipped with a faster and more efficient processing ability. In this paper, we designed the Rhino XR-3 Robot Controller which controls five joints concurrently. To reduce the size of the controller and to control 6 dc-servo motors in real time, we use the TMS320c31, the high-speed digital signal processor.

  • PDF

The Study on the Failure Rate Sampling Plan Considering Cost (비용을 고려한 신뢰성 샘플링검사 설계에 관한 연구)

  • 조재립
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.23 no.59
    • /
    • pp.97-103
    • /
    • 2000
  • This study considers the design of life test sampling inspection plans by attributes for failure rate level qualification at selected confidence level. The lifetime distribution of products is assumed to be exponential. MIL-STD-690C and KS C 6032 standards provide this procedures. But these procedures have some questions to apply in the field. The cost of test and confidence level($1-{\beta}$ risk) are the problem between supplier and user. So, we suggest that the optimal life test sampling inspection plans using expected cost model considering product cost, capability, environmental test cost, etc.

  • PDF

Characteristics Analysis of Magnetic Levitation Conroller (자기부상제어기의 특성해석)

  • Kim, Jong-Moon;Kim, Choon-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.735-736
    • /
    • 2006
  • In this paper, the characteristics analysis results of the levitation controller of magnetically-levitated vehicle are presented. To get a good closed-loop system, the observer and controller must be designed to meet the control performance and ride quality requirements. So the transfer functions of the observer filter are described and analysed by using the relative and absolute signal concepts.

  • PDF

Study on the Establishment of Threshold Criteria for Heat Health Watch Warning System in Korea; Part II: Improvement of Criteria (고온건강경보시스템 기준 설정에 관한 연구 ( II ) - 설정 기준 개선 -)

  • Jung, Woo-Sik;Park, Jong-Kil;Kim, Eun-Byul;Song, Jeong-Hui
    • Journal of Environmental Science International
    • /
    • v.18 no.7
    • /
    • pp.781-796
    • /
    • 2009
  • The current standard level of Heat Health Watch Warning System consider both daily maximum temperature and daily maximum heat index(HI), but current standard could not consider daily maximum HI due to the difficulties in forecasting when we consider both daily maximum temperature and daily maximum HI and no considering HI because relative humidity could not observed for some regions. So, Newly established standard level of Heat Health Watch Warning System is based on daily maximum temperature exceeding $30^{\circ}C$ for two consecutive days or daily minimum temperature exceeding $25^{\circ}C$ and daily maximum temperature exceeding $30^{\circ}C$. These days are called "extreme heat days". On extreme heat days, the standard of extreme heat advisory is based on daily maximum temperature among exceeding $32.7^{\circ}C$ and not exceeding $34.8^{\circ}C$, and extreme heat warning is based on daily maximum temperature exceeding $34.8^{\circ}C$. ANOVA analysis was carried out using the data of Seoul Metropolitan City in 1994 to check the robustness of the new standard level of Heat Health Watch Warning System from this study, in particular for mortality variable. The results reveal that the new standard specifies excess mortality well, showing significance level of 0.05 in the difference of excess mortality for each phase.