• 제목/요약/키워드: Snubber

검색결과 411건 처리시간 0.022초

저압 중용량 인버터에서의 기생 인덕턴스에 의한 영향 (Effects of stray inductance on low volatge inverter for medium capacity)

  • 최종선;전태원;김지용;김흥근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 추계학술대회 논문집
    • /
    • pp.61-63
    • /
    • 2008
  • An inverter with large capacity has been demanded at a factory automation and diffusion of the energy saving work. As the capacity of inverter is larger, the stary inductance has much influence on both the di/dt of IGBT current, and voltage stress across IGBT. Also, the life of the snubber capacitor may be shortened due to overheating of the snubber capacitor. In this paper, a planar busbar which consists of two layers is applied to N700-series inverter in order to minimize stray inductance. The voltage stress across IGBT is changed by both the DC busbar structure and the capacity of snubber capacitor.

  • PDF

개선된 소프트 스위칭 Two-transistor forward converter (An Improved Soft Switching Two-transistor Forward Converter)

  • Kim, Marn-Go
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.137-140
    • /
    • 2000
  • This paper proposes an improved soft switching two-transistor forward converter which uses a novel lossless snubber circuit to effectively control the turn-off dv/dt rate of the main transistors. In the proposed soft switching implementation the turn-off voltage traces across the main two transistors are almost the same contributing to reduce the total capacitive turn-on loss and the snubber current is divided into the two transistors resulting in distributed thermal stresses

  • PDF

Planar 변압기와 무손실 스너버를 사용한 포워드 컨버터 (Forward Converter using Planar transformer and Lossless Snubber)

  • 박경수;이재학;김춘삼;김윤호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.480-484
    • /
    • 1999
  • In this paper, a design technique of SMPS using plannar transformer is described. The application of plannar transformer can solve the space problem which occurs when it is installed on PCB since plannar transformer has low profile. In addition a lossless snubber circuit added to reduce the device stress and to improve the system efficiency. The designed system is verifed by simulation and experiment with comparison of efficiency between the system using conventional transformer and the system using plannar transformer.

  • PDF

스너버 에너지를 이용한 IGBT 구동 회로 (IGBT gate drive circuit using snubber energy)

  • 김성철;전성즙
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2112-2114
    • /
    • 1998
  • A gate driver suitable for forced switch-mode power converters such as UPS and motor drive system is presented. The proposed gate driver uses regenerated snubber power and requires no separate power supply. This does not impose any additional complexity on the main switch. Experimental results show that the proposed circuit is valid.

  • PDF

PFC와 무손실 스너버를 이용한 Two-Transistor Forward Converter의 특성해석 (Characteristics Analysis of Two-Transistor Forward Converter using PFC and Lossless Snubber Circuit)

  • 배진용;김용;백수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.176-179
    • /
    • 2005
  • This paper proposed the two-transistor forward circuit using PFC, lossless snubber and synchronous rectifier for low voltage and high current output. The principle of operation, feature and design considerations is illustrated and verified through the experiment with a 200W(5V, 40A) 100kHz MOSFET based experimental circuit.

  • PDF

스너버의 마찰을 고려한 하부지지형 세탁기의 진동 해석 (Vibrational analysis of the base supported washing machine considering the frictional effect in snubber)

  • 최상현;김주호;한창소;한동철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1993년도 추계학술대회논문집; 반도아카데미, 26 Nov. 1993
    • /
    • pp.99-105
    • /
    • 1993
  • 본 연구에서는 세탁통 및 감속장치가 스너버(Snubber)와 지지 스프링에 의 해서 지지되는 하부지지형 세탁기를 모델로 선택하였으며, 시스템의 동특성 해석을 위하여 세탁기를 회전체를 갖는 강체 현가 시스템으로 모델링하고 운동방정식을 구하여 수치 해법을 적용하여 진동 특성을 계산하였다. 세탁기 의 진동 형태를 예측하기 위해서 밑판의 마찰 계수, 스터버의 곡률 반경, 지지 스프링 계수 및 위치 등을 진동량에 영향을 미치는 설계 변수로 선정하여 결과를 구하였으며, 이 자료들을 설계 변경시에 이용할 수 있게 하였다.

  • PDF

액티브 보조 공진 스너버를 이용한 ZVT-PWM AC-DC 컨버터의 실험적 고찰 (The Experimental Consideration of ZVT-PWM AC-DC Converter using Active Auxiliary Resonant Snubber)

  • 서기영;문상필;김주용;박진민
    • 조명전기설비학회논문지
    • /
    • 제18권2호
    • /
    • pp.75-82
    • /
    • 2004
  • 본 논문에서 액티브 스너버 회로를 가진 영전압 변환 펄스 폭 변조(ZVT-PWM) 컨버터를 제안하였다. 제안된 컨버터는 경부하 상태에서도 동작하며, 영전압 스위칭과 영전류 스위칭 부근에서 온-오프 되며, 주 스위치와 주다이오드에 전압과 전류의 스트레스가 추가적으로 발생하지 않는다. 그리고 보조 스위치와 보조 다이오드의 전압과 전류 허용 레벨을 제시하였다. 제안된 750[W], 80[KHz] PWM 부스터 컨버터는 전 출력 전력에서 소프트 스위칭 컨버터를 적용하여 실행한 결과 주 스위치에서의 손실은 하드 스위칭과 비교해서 약 27[%], 전체 회로 손실은 약 36[%] 저감되었으며, 전체 효율은 기존의 컨버터보다 보다 6{%] 정도 향상됨을 확인하였다.

Dual Utility AC Line Voltage Operated Voltage Source and Soft Switching PWM DC-DC Converter with High Frequency Transformer Link for Arc Welding Equipment

  • Morimoto Keiki;Ahmed NabilA.;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권4호
    • /
    • pp.366-373
    • /
    • 2005
  • This paper presents two new circuit topologies of the dc busline side active resonant snubber assisted voltage source high frequency link soft switching PWM full-bridge dc-dc power converters acceptable for either utility ac 200V-rms or ac 400V-rms input grid. These high frequency switching dc-dc converters proposed in this paper are composed of a typical voltage source-fed full-bridge PWM inverter, high frequency transformer with center tap, high frequency diode rectifier with inductor input filter and dc busline side series switches with the aid of a dc busline parallel capacitive lossless snubber. All the active switches in the full-bridge arms as well as dc busline snubber can achieve ZCS turn-on and ZVS turn-off transition commutation with the aid of a transformer leakage inductive component and consequently the total switching power losses can be effectively reduced. So that, a high switching frequency operation of IGBTs in the voltage source full bridge inverter can be actually designed more than about 20 kHz. It is confirmed that the more the switching frequency of full-bridge soft switching inverter increases, the more soft switching PWM dc-dc converter with a high frequency transformer link has remarkable advantages for its power conversion efficiency and power density implementations as compared with the conventional hard switching PWM inverter type dc-dc power converter. The effectiveness of these new dc-dc power converter topologies can be proved to be more suitable for low voltage and large current dc-dc power supply as arc welding equipment from a practical point of view.

왕복동식 압축기의 스너버내 맥동압 분포 (Pulsatile Pressure Distribution on the Snubber of Reciprocating Compressor)

  • 이경환;;정한식;정효민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.606-611
    • /
    • 2007
  • Pulsation is an inherent phenomenon in reciprocating compressors. It interacts with piping to cause vibrations and performance problems. Indiscriminately connecting to a compressor can be dangerous and cost money in the form of broken equipment and piping, poor performance, inaccurate metering, unwanted vibration, and sometimes noise. Piping connected to a compressor can materially affect the performance and response. To minimize these detrimental effects, reciprocating compressor system should be equipped by pulsation suppression system. This study discusses pressure pulsation phenomena occurred in a reciprocating compressor system. An experiment applied air compressor unit, as pulsating pressure generator, has been done. The compressor was connected sequentially to a snubber model and pressure tank. Sensor probes were placed on the inlet and outlet pipes of snubber. Compressor was driven by a motor controlled by a frequency regulator. The experiment was conducted by adjusting the regulator at 40Hz. General information about an internal gas flow can be achieved by numerical analysis approach. Information of the velocity, pressure and turbulence kinetic energy distribution are presented in this paper. Based on this result, the design improvement might be done.

  • PDF

ZVS-PWM Boost Chopper-Fed DC-DC Converter with Load-Side Auxiliary Edge Resonant Snubber and Its Performance Evaluations

  • Ogura, Koki;Chandhaket, Srawouth;Ahmed, Tarek;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제4권1호
    • /
    • pp.46-55
    • /
    • 2004
  • This paper presents a high-frequency ZVS-PWM boost chopper-fed DC-DC converter with a single active auxiliary edge resonant snubber in the load-side which can be designed for power conditioners such as solar photovoltaic generation, fuel cell generation, battery and super capacitor energy storages. Its principle operation in steady-state is described in addition to a prototype setup. The experimental results of ZVS-PWM boost chopper-fed DC-DC converter proposed here, are evaluated and verified with a practical design model in terms of its switching voltage and current waveforms, the switching v-i trajectory, the temperature performance of IGBT module, the actual power conversion efficiency and the EMI of radiated and conducted emissions. And then discussed and compared with the hard switching scheme from an experimental point of view. Finally, this paper proposes a practical method to suppress parasitic oscillation due to the active auxiliary resonant switch at ZCS turn off mode transition with the aid of an additional lossless clamping diode loop, and reduced the EMI conducted emission in this paper.