• Title/Summary/Keyword: Sn$Cl_2$

Search Result 255, Processing Time 0.024 seconds

On the $SnO_2$ Semiconductor Gas Sensor ($SnO_2$ 소결체 반도체 Gas Sensor에 관한 연구)

  • 박순자;이재열
    • Journal of the Korean Ceramic Society
    • /
    • v.20 no.2
    • /
    • pp.93-98
    • /
    • 1983
  • The sensitivity characteristics of $SnO_2$-based gas sensor prepared by sintering method have been studied at the presence of CO and Propane gas. Samples mixed with 1wt% $La_2O_3$ and 1wt% $PdCl_2$ showed highest sensitivity to CO and propane gas at 250$^{\circ}$C but the addition of $CeO_2$ did not enhance the sensitivity. For slectivity for gas a $SnO_2-La_2O_3$ (1wt%) sample without $PdCl_2$ showed better results. A sample sintered sintered at 115$0^{\circ}C$ has shown the optimum condition in sensitivity and electroding

  • PDF

Deposition Behaviors and Electrical Properties of Sb-doped $SnO_2$ Films by Plasma Enhanced Chemical Vapor Deposition (PECVD법에 의해 제조된 Sb-doped $SnO_2$ 박막의 증착거동 및 전기적 특성)

  • 김근수;서지윤;이희영;김광호
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.2
    • /
    • pp.194-200
    • /
    • 2000
  • Sb-doped tin oxide films were deposited on Corning glass 1737 substrate by plasma enhanced chemical vapor deposition(PECVD) technique using a gas mixture of SnCl4/SbCl5/O2/Ar. The deposition behaviors of tin oxide films by PECVD were compared with those by thermal CVD, and effects of deposition temperature, r.f. power and Sb doping on the electrical properties of tin oxide films were investigated. PECVD technique largely increased the deposition rate and smoothed the surface of tin oxide films compared with thermal CVD. Electrical resistivity decreased with doping of Sb due to the increase of carrier concentration. However, large doping of Sb diminished carrier concentration and mobility due to the decrease of crystallinity, which resulted in the increase of electrical resistivity. As the deposition temperature and r.f. power increased, Cl content in the film decreased.

  • PDF

Dependency of SnO2 System Carbon Monoxide Gas Sensor on the Atmospheric Temperature & Humidity ($SnO_2$계 일산화탄소 가스 감지 소자의 주위온도, 습도 의존성에 관한 연구)

  • 정형진;김종만;이전국
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.8
    • /
    • pp.1004-1010
    • /
    • 1990
  • SnO2-ThO2-PdCl2-In2O3 gas sensing ceramic systems were studied in order to lowr the operating temperatures and reduce the dependence of ambient temperatures and humidities. Sensing materials were coated by brush on the alumina tube followed by the impregnation of solidfier(ethylsilicate). Coated species were dried and sintered at 75$0^{\circ}C$ for 30min. carbon monoxide gas detecting sensitiviteis were measured in various ambinet temperatures and humidities. In the composition of 94SnO2-5ThO2-PdCl2 system carbon monoxide gas detecting sensors showed the highest detecting sensitivities and the lowest operating temperature(15$0^{\circ}C$). As the ambient temperatures and humidities were increased, sensitivities were decreased. Because the oscillation effects were observed at high humidities, it was suggested that the sensitivities of sensors depend greatly on the humidities.

  • PDF

The Enhancement of Selectivity in Thick Film SnO2 Gas Sensors by Additives and Pattern Recognition (첨가제 및 패턴인식에 의한 후막 SnO2 가스센서의 선택성 향상)

  • 정해원;김종명;박희숙;윤기현
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.11
    • /
    • pp.1073-1077
    • /
    • 2003
  • The Sn $O_2$-based gas sensors can detect inflammable and toxic gases of low concentration by the modulation of surface resistance, but they lack in selectivity on the whole. To give selectivity to the Sn $O_2$-based gas sensors, studies on the sensing mechanism, selective gas sensing materials and signal processing techniques are demanded. Ethanol (C$_2$ $H_{5}$OH) and acetonitrile ($CH_3$CN) were confirmed to undergo catalytic oxidation on Sn $O_2$ by gas chromatography. PdCl$_2$-doped Sn $O_2$ showed excellent sensitivity to ethanol and acetonitrile, while La$_2$ $O_3$-doped Sn $O_2$ showed excellent sensitivity to ethanol, but poor sensitivity to acetonitrile. Using these two sensors and pattern recognition, the selectivity to acetonitrile is greatly enhanced. The minimum detection level of acetonitrile was 15 ppm in air and 20 to 100 ppm when exposed to interfering gases together with acetonitrile.

Preparation of SnO and SnO, SnO2 fine powder by hydrazine method (Hydrazine법에 의한 SnO, SnO2 미분말의 합성)

  • Kim, Kang-Min;Kim, Ki-Won;Cho, Pyeong-Seok;Lee, Jong-Heun
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.297-301
    • /
    • 2005
  • Nanocrystalline SnO and $SnO_{2}$ powder have been prepared by hydrazine method. Sn-Hydrazine complex was formed by the reduction between aqueous $SnCl_{2}$ solution and hydrazine monohydrate. $SnO_{2}$ nano powder was prepared by the decomposition of Sn-Hydrazine complex at $450^{\circ}C$. When NaOH was added to Sn-hydrazine complex, SnO powder with nano-sheet morphology could be prepared. This can be attributed to the role of $OH^{-}$ ion as a reducing agent.

Effects of Pd Addition Amount and Method on the Characteristics of SnO2 Semiconductor Thick Films for Alcohol Gas Sensors (Pd 첨가량 및 첨가방법이 알코올 센서용 SnO2 반도체 후막 특성에 미치는 영향 연구)

  • Kim, Jun-Hyung;Kim, Hyeong-Gwan;Lee, Ho-Nyun;Kim, Hyun-Jong;Lee, Hee-Chul
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.5
    • /
    • pp.411-420
    • /
    • 2017
  • In this paper, two methods of making the Pd-added $SnO_2$ ($Pd-SnO_2$) powder with pure tetragonal phase by the hydrazine method were suggested and compared in terms of crystal structure, surface morphology, and alcohol gas response. One of the addition methods is to use $PdCl_2$ as a Pd source, the other is to use Pd-based organic with oleylamine (OAM). When Pd concentration was increased from 0 to 5 wt%, the average grain size of $Pd-SnO_2$ made with Pd-OAM were decreased from 32 to 12 nm. In the case of using with $PdCl_2$, grain size of the $PdCl_2$ fell to less than 10 nm. However, agglomerated and extruded surface morphology was observed for the films with Pd addition over 4 wt%. The crack-free $Pd-SnO_2$ thick films were able to successfully fill the $30{\mu}m$ gap of patterned Pt electrodes by optimized ink dropping method. Also, the 2 wt% $Pd-SnO_2$ thick film made with PdCl2 showed gas responses ($R_{air}/R_{gas}$) of 3.7, 5.7 and 9.0 at alcohol concentrations of 10, 50 and 100 ppm, respectively. On the other hand, the prepared 3 wt% $Pd-SnO_2$ thick film with Pd-OAM exhibited very excellent responses of 3.4, 6.8 and 12.2 at the equivalent measurement conditions, respectively. The 3 wt% $Pd-SnO_2$ thick film with Pd-OAM has a specific surface area of $31.39m^2/g$.

Investigation of Liposomes Labelled with Tc-99m Added EDTA, DTPA and NTA for Tumor Seeker ($^{99m}Tc-Liposomes$과 킬레이트제 표지반응의 효과)

  • Ryu, Yong-Wun;Kim, Jang-Hwi;Kang, Tae-Woong;Yu, Ju-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.19 no.1
    • /
    • pp.137-143
    • /
    • 1985
  • Using chelating agents such as Nitrilotriaceticacid(NTA), ticacid(DTPA) and Ethylenediaminenitrilotetraceticacid(EDTA), with TC-99m were determined in vitro and in vivo. Methods.of separation and determination of TC-99m-liposomes added chelating agents were practiced by thin layer chromatogram scan and gel filtration. Biodistributions of Tc-99m-liposomes in normal and sarcoma 180 cells bearing mice were observed. The results were as follows: 1) Maximum amount of $Sn^{+2}$ to reduction from pertechnetium$(10\sim20{\mu}ci)$ by adding 0, 1, 10 and $100{\mu}g$ of $SnCl_2$ in 0.2 ml of oxygen free water was $10{\mu}g$. 2) The large amounts of $SnCl_2$ were not changed but the small amounts of $SnCl_2$ were much changed by labeling with TC-99m to add chelating agents. EDTA in small amounts of $SnCl_2$ were reduced more strongly than DTPA or NTA. Using a hydrophilic chelate, DTPA, the uptake of liposomes could not accumulated in liver and spleen by a lipophilic chelate NTA were significant in vivo. 3) Uptake by tumor was achived 1.14% of injected dose per gram tissue and tumor to organ ratios were measured in low with TC-99m-NTA-liposomes(+).

  • PDF

Syntheses of Cu2SnSe3 and Their Transformation into Cu2ZnSnSe4 Nanoparticles with Tunable Band Gap under Multibubble Sonoluminescence Conditions

  • Park, Jongpil;Lee, Won Young;Hwang, Cha Hwan;Kim, Hanggeun;Kim, Youngkwon;Shim, Il-Wun
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.8
    • /
    • pp.2331-2334
    • /
    • 2014
  • $Cu_2SnSe_3$ (CTSe) and $Cu_2ZnSnSe_4$ (CZTSe) nanoparticles were synthesized by sonochemical reactions under multibubble sonoluminescence (MBSL) conditions. First, $Cu_2SnSe_3$ nanoparticles were synthesized by the sonochemical method with an 85% yield, using CuCl, $SnCl_2$, and Se. Second, ZnSe was coated on the CTSe nanoparticles by the same method. Then, they were transformed into CZTSe nanoparticles of 5-7 nm diameters by heating them at $500^{\circ}C$ for 1 h. The ratios between Zn and Sn could be controlled from 1 to 3.75 by adjusting the relative concentrations of CTSe and ZnSe. With relatively lower Zn:Sn ratios (0.75-1.26), there are mostly CZTSe nanoparticles but they are believed to include very small amount of CTS and ZnSe particles. The prepared nanoparticles show different band gaps from 1.36 to 1.47 eV depending on the Zn/Sn ratios. In this sonochemical method without using any toxic or high temperature solvents, the specific stoichiometric element Zn/Sn ratios in CZTSe were controllable on demand and their experimental results were always reproducible in separate syntheses. The CZTSe nanoparticles were investigated by using X-ray diffractometer, a UV-Vis spectrophotometer, scanning electron microscope, Raman spectroscopy, and a high resolution-transmission electron microscope.

Development of Methane Gas Sensor by Various Powder Preparation Methods

  • Min, Bong-Ki;Park, Soon-Don;Lee, Sang-Ki
    • The Korean Journal of Ceramics
    • /
    • v.5 no.2
    • /
    • pp.125-130
    • /
    • 1999
  • After $SnO_2$ fine powder by precipitation method, Ca as crystallization inhibitor and Pd as catalyst were added to $SnO_2$ raw material by various methods. Thick film device was fabricated on the alumina substrate by mixing ethylene glycol and such mixed powders. The sensing characteristics of the device for methane gas were investigated. The most excellent gas sensing property was shown by the thick film device fabricated by Method 3 in which Ca and Pd doped $SnO_2$ powder is prepared by mixing $SnO_2$ powder, 0.1 wt% Ca acetate and 1 wt% $PdCl_2$ in deionized water and by calcining the mixture, after $Sn(OH)_4$ is dried at $110^{\circ}C$ for 36h. The sensitivity of the sensor fabricated with $SnO_2$-0.1 wt%Ca acetate-1wt%$PdCl_2$ powder heat-treated at $700^{\circ}C$ for 1h was about 86% for 5,000 ppm methane in air at $350^{\circ}C$ of the operating temperature. Response time and recovery were also excellent.

  • PDF