• 제목/요약/키워드: Smoke removal

검색결과 72건 처리시간 0.021초

선로부 TES를 갖는 지하철 역사내 화재의 수치 해석 (A NUMERICAL STUDY ON THE FIRE EMERGENCY IN THE UNDERGROUND STATION WITH TRACKWAY EXHAUST SYSTEM (TES))

  • 박종택;원찬식;허남건
    • 한국전산유체공학회지
    • /
    • 제11권4호
    • /
    • pp.26-31
    • /
    • 2006
  • In the present study, a numerical simulation of the subway carriage fire is performed to determine the more effective operation of Trackway Exhaust System(TES) in underground stations. The four types of possible TES operation (OSUS, OSUE, OEUS and OEUE) is simulated and compared their removal capability of smoke and hot temperature for the carriage fire of 2MW. From the results, the distribution of temperature and smoke concentration is more dependent on the operation of fans located at upper side of the platform than those at lower side. It is also found from the results that for more efficient smoke control, the fans at upper side of the platform should be operated as an exhaust system. Whereas the fans at lower side can be operated as a supply system to aid upper exhaust fans.

제품담배 연기성분 분포 특성 조사 및 물리적 특성과의 관련성 구명 (Study of Smoking Component Distribution and the Relation between Chemical Components and Physical Characteristics of Cigarettes)

  • 황건중;이영택
    • 한국연초학회지
    • /
    • 제23권2호
    • /
    • pp.179-184
    • /
    • 2001
  • This study was conducted to determine the smoke component distribution and the relationship between chemical components and physical characteristics of cigarettes. 16 different cigarette brands which were sold in the market were selected for this study. Five kinds of smoke components which have been tar, nicotine, water, carbon monoxide(CO) puff No., and six kinds of physical characteristics which were filter type, leaf weight, filter weight, UPD, EPD, dilution rate were analyzed. The average values in tar, nicotine, water, CO concentration were 6.5 mg/cig. 0.66 mg/cig, 1.12 mg/cig. and 6.32 mg/cig., respectively. The average ratios of nicotine/tar and CO/tar were 0.10, and 1.02 respectively. The distribution of smoke components collected in the cambridge filter and cigarette filter was different. The averages of tar and nicotine removal efficiency by a cigarette filter were 53%, and 48%, respectively. All smoking components were positively correlated with other smoking components. filter types, EPD, and dilution rate were showed high correlation to the changes of smoke components. Especially, dilution rate of cigarette strongly affected on the changes of all smoke components.

  • PDF

A Study on the Smoke Removal Characteristics of the ESP Adopting Resonant dc-dc Converter

  • Kim, Su-Weon;Park, Jong-Woong;Joung, Jong-Han;Chung, Hyun-Ju;Choi, Jin-Young;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권5호
    • /
    • pp.193-200
    • /
    • 2004
  • In this study, we propose a small high voltage power supply, which uses a half-bridge ZCS resonant and Cockroft-Walton circuit as its ESP (Electrostatic Precipitator). This power supply transfers energy from the ZCS resonant inverter to the step-up transformer. The transformer secondary is then applied to the Cockroft-Walton circuit for generating high voltage as a discharging source of electrodes. It is highly efficient because its amount of switching losses are reduced by virtue of the current resonant half-bridge inverter, and also due to the small size, low parasitic capacitance in the transformer stage owing to the low number of winding turns of the step up transformer secondary combined with the Cockroft-Walton circuit. Using this power supply, experiments have been carried out as a function of the switching frequency and duty ratio in order to investigate the smoke removal characteristics. From these results, the best operational condition is obtained at the switching frequency of 9 kHz and the duty ratio of 50% in this ESP.

담배필터용 흡착제에 관한 연구 제1보. 흡착제의 종류와 동공특성이 담배연기성분 제거능에 미치는 영향 (Studies on the Adsorbents for Cigarette Filter I. Effect of Pore Voume Distribution and Specific Area of Adsorbents on the Removal Efficiency of Smoke Components by Triple Filter)

  • 박태무;이영택;김성한;오영일
    • 한국연초학회지
    • /
    • 제10권1호
    • /
    • pp.75-82
    • /
    • 1988
  • Cigarettes were made using a triple filter with several porous materials in its cavity. The removal effect of the adsorbents on carbon monoxide and hydrogen cyanide in cigarette smoke was investigated with the variation of their surface area and pore volume distributions. Several attempts were made to activated coconut shell based char under the fixed steam purging rate. 1. The specific surface area increased in number of micropore. It was found for transitional pore to have a little effect on the total surface area. 2. A Small amount of the particulate matter adsorbed on the adsorbents with transitional pores, Zeolite showed a little effect on the carbon monoxide adsorption though its small pore volume, but there was no significant difference in the adsorption capacity zeolite and the others. 3. In the adsorption for hydrogen cyanide as a vapor phase in cigarette smoke, the adsorption effect of the adsorbents increased remarkably with increasing their surface area and number of micropore. It was considered that the adsorbents with small pore volume like molecular seive 4A, in which the capillary diffusion of adsorbates could not be able, would not be effective for the adsorption of hydrogen cyanide.

  • PDF

실내 공기정화 시스템에 의한 실내 오염입자의 제거특성에 관한 실험적 연구 (An Experimental Study on the Removal Characteristics of Indoor Air Pollutants using an Air Cleaning System)

  • 김성찬;이창건;안영철;이재근;강태욱;이감규;구정환
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.733-737
    • /
    • 2003
  • The purpose of this study is to analyze the particle removal characteristics of a commercial air cleaner based on the electrostatic precipitator. The air cleaner consists of a positive corona precharger to precharge particles and a collector to remove the charged particles. The test for particle removal efficiency is conducted with tobacco smoke particles of 1.27${\mu}{\textrm}{m}$ in mass median diameter. The result of one-pass filtration test shows that the filtration efficiency is more than 90% for the particles larger than 2.5 Um, while the efficiency for the particles of 0.5~1.0${\mu}{\textrm}{m}$ in case of 4.18 CMM is 70%. For the test room of 5,800${\times}$3,400${\times}$2,600㎣, the concentration of tobacco smoke particles decreases up to 30% of initial values within 30 minutes due to natural reduction and up to 90% of initial values within 30 minutes with the air cleaner operation.

실공간에서 공기정화시스템을 이용한 실내 오염 입자 제거 특성에 관한 연구 (A Study on the Removal Characteristics of Indoor Air Pollutants using the Air Cleaning System)

  • 구정환;김성찬;김장우;이주용;이재근;강태욱;이감규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.532-537
    • /
    • 2000
  • The purpose of this study is to determine the performance of a commercial air cleaner in removing tobacco smoke indoors. Following injection of tobacco smoke in a room, decay rates for particle concentrations were obtained far mass concentration at each point. The size distribution of the tobacco smoke particles was approximately $1.266{\mu}m$ in mass median diameter with a geometric standard deviation of 1.313. The air cleaner consisted of an electrostatic filtration unit and a fan operated at a flow rate of 5.98 CMM. The collection efficiency for $>1\;{\mu}m$ was more than 99%. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 30% of initial values within 30 minutes and with air cleaner operation, decreased to 90% of initial values in the test chamber, volume $51.27\;m^3$. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 10% of initial values within 30 minutes and with air cleaner operation, decreased to 30-70% of initial values in the test chamber, volume $149.2\;m^3$.

  • PDF

Hydrazine 첨착 흡착제의 제조 및 담배 주류연 중 카보닐 화합물의 선택 흡착 특성 (Preparation of Hydrazine Impregnated Adsorbents and Selective Adsorption Properties for Carbonyl Compounds in Cigarette Mainstream Smoke)

  • 이존태;박진원;이정민;이문수;황건중;황택성
    • 폴리머
    • /
    • 제30권3호
    • /
    • pp.210-216
    • /
    • 2006
  • 담배 주류연 중 카보닐 화합물의 선택적 감소를 위한 필터 물질을 제조하기 위하여 하이드라존 반응에 있어서 촉진제로 사용되는 과염소산과 인산을 2,4-dinitrophenylhydrazine (2,4-DNPH)와 dansylhydrazine (DAH)과 함께 각각의 흡착제에 첨착시켰다. 제조된 첨착 흡착제의 구조는 FTIR/ATR을 이용하여 확인하였으며 SEM을 이용하여 표면을 관찰하였다. 또한 첨착 시간과 촉진제 그리고 첨착 시약에 따른 첨착량과 담배 주류연 중 카보닐 화합물의 흡착특성을 조사하였다. 첨착량은 첨착 시간에 따라 증가되었으며 2.4-DNPH를 첨착한 흡착제의 경우 다른 흡착제에 비해 카보닐 화합물의 제거 효율이 우수하였다. 또한 폴리아크릴계 흡착제에 2,4-DNPH를 첨착시킬 경우 다른 기재의 흡착제에 비해 우수한 제거 효율을 나타내었는데 이러한 결과들로부터 궐련필터로의 적용 가능성을 확인할 수 있었다.

레이저 혼탁도 모니터링을 통한 공기청정 특성에 관한 연구 (A study on characteristic of the smoke removal of an air cleaner by monitoring of turbidity with laser)

  • 김수원;박종웅;정종한;정현주;이유수;전진안;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1698-1700
    • /
    • 2003
  • The electrostatic precipitator(ESP) is a device for removing particulate pollutants in the form of either a solid (dust or fumes) or a liquid (mist) from a gas using an electrostatic force, Electrostatic precipitation has been widely used for cleaning gas from almost all industrial processes with a medium to large gas volume(>2,000 $m^3/min$), including utility boilers, blast furnaces, and cement kilns. ESP is also in wide use for air cleaning in living environments (home, offices, hospitals, etc.) ESP has large advantages over other particulate control device : a low operating cost, a high collection performance, and ease of maintenance. The purpose of this study is to investigate the characteristics of the smoke removal of an air cleaner by adjusting variable frequency and monitoring of turbidity three results of this research are as follows ;the first is the best efficient switching frequency which is 60Hz, the second is the smoke removal time which is obtained to 9 seconds, third is that the best efficient firing angle is $90^{\circ}$ As a result, the switching trigger frequency and SCR gate firing angle is very important factor to predict the best collection efficiency.

  • PDF

활성탄 첨가에 따른 담배용 필터지의 이화학적 특성 (Physical and Chemical Properties of Charcoal Added Paper for Cigarette Filter)

  • 이문용;전양;김영호;이정일
    • 펄프종이기술
    • /
    • 제31권4호
    • /
    • pp.76-83
    • /
    • 1999
  • This study was carried to investigate optimum conditions of charcoal added paper in making cigarette filter for the removal of smoke contents of cigarettes. We investigated the physical properties of charcoal added paper according to the ratio of pulps, the amounts of characoal , the weight of sheets and crimping conditions in dry method, and then analyzed the smoke contents of cigarettes. The results obtained were as follows. 1. Sw-BKP was higher than Hw-BKP in methylene blue absorption by UV test. 2. Charcoal had an effect on stiffness for decreasing factor greatly , while the addition amounts of Sw-BKP and high weigth of sheets increased it, and the interaction of weight of sheets and charcoal was higher than other factors. 3. Tear index decreased by charcoal addition greatly, on the other hand high weight of sheets and Sw-BKP/Hw-BKP ratio increased ter, and the interaction of pulps and chacoal acted on major factors. 4. We estimated crimp index with sensory evaluation , and charcoal hand an effect on decreasing factor in crimping greatly, while the interaction of weight of sheets and pulp ratio was higher than others. 5. In the case of charcoal added paper filter, tar removal efficiency of smoke contents was higher but about 6% than cigarette filter. Especially vapour phase(aldehyde) in smoke contents was removed greatly.

  • PDF