• 제목/요약/키워드: Smoke layer

검색결과 119건 처리시간 0.028초

건축화재시 피난대책에 관한 연구 -고층건물의 제연을 중심으로- (A Study on the Smoke Proof Measure of High Rise Buildings.)

  • 이영재;이근영
    • 한국화재소방학회논문지
    • /
    • 제4권1호
    • /
    • pp.3-12
    • /
    • 1990
  • This study is to Present the air Pressurization system of staircase as a way to decrease the injury of human life which is suffocated by smoke when the fire break out in building. 1) The best among an air pressurization system of stairshaft Is multiple air Injection system established to be situated an air injection point in each layer. 2) If the air pressurization system is also applied to the elevator accessory room to use commonly, it can prevent from the smoke spreading and pollution inside building caused by stack effect of elevator shaft. 3) For the reasonable and safe escape and air pressurization system must be carried out from the project of basic shape of building under the close cooperation with architect and fire protection expert.

  • PDF

화재 시뮬레이션(FDS)을 이용한 거실제연설비 개선에 관한 연구 (A Study on Improvenment of Livingroom Smoke-control System using the FDS)

  • 김미선;백은선
    • 한국화재소방학회논문지
    • /
    • 제31권4호
    • /
    • pp.26-34
    • /
    • 2017
  • 본 논문은 거실제연설비의 인접구역 상호제연방식의 성능 확인 및 향상을 위한 논문으로써 국가화재안전기준(NFSC)과 NFPA 연기제어에 관한 규정을 비교 분석하였다. 분석방법은 화재 시뮬레이션(FDS)을 통해 모델링을 실시하여, 급기량 변화, 제연경계의 폭, 화재실내 가연물 변화, 유입공기의 풍속차이를 통해 이루어졌다. 그 결과 청결층 확보를 위해 급기량을 배출량 이하로 하였을때 화재실에서의 청결층 확보에 유리한 것으로 나타났으나 급기실에서는 급기량을 배출량 이상으로 하였을때 청결층 확보에 유리한 것으로 나타났으며, 제연경계의 폭이 길어질수록 성능 확보에 유리한 것으로 나타났다. 또한 가연물의 종류에 따라 급기량과 배출량을 고려해야 하며, 공기유입구 풍속은 급기량을 감소시킴과 동시에 공기유입구 풍속을 낮게 하므로써 화재실의 청결층 확보에 유리한 것으로 나타났다.

터널 내 화재 시 경사에 따른 온도층 및 연기유동 특성 (The dynamic characteristics of upper hot gas layer and smoke propagation along with tunnel slope in case of fire)

  • 이동호;김하영;문성웅;유지오
    • 한국터널지하공간학회 논문집
    • /
    • 제11권3호
    • /
    • pp.223-228
    • /
    • 2009
  • 본 연구는 터널 내 화재 시 온도층 및 연기층의 유동성향을 분석한다. 이를 위해 전산 시뮬레이션을 활용하였다. NIST의 FDS를 통해 국도 및 고속도로 표준단면을 기준으로 화재 시나리오를 설정하였다. 연기층의 이동거리는 터널의 단면적이 증가할수록 내부 풍속에 의한 영향력이 감소하였으며, 내부 풍속이 상승할수록 경사에 의한 영향력이 감소하였다. 온도층의 이동거리는 내부풍속이 상승할수록 경사에 의한 영향력이 감소하였으며, 1 m/s 이상의 풍속에 냉각효과가 나타나 경사에 의한 영향력이 감소하였다

실물터널 화재실험을 통한 터널화재 위험도 평가 (The Risk Assessment of Tunnel Fire Through Real Scale Fire Test)

  • 최준석;최병일;김명배;한용식;장용재;이유환;황낙순;김필영
    • 한국화재소방학회논문지
    • /
    • 제16권3호
    • /
    • pp.71-76
    • /
    • 2002
  • 실제 터널화재에서의 위험성을 평가하기 위하여, 국내에서 최초로 실물터널 화재실험이 수행되었다. 길이 465m의 터널에서 0.25MW에서 2.5MW까지의 가솔린 풀과 1500cc승용차를 화원으로 사용하였으며, 터널내의 유속을 조정하기 위하여 6대의 제트팬을 설치하였다. 터널내의 온도분포와 연기거동을 살펴보기 위하여 총 86곳의 온도를 측정하였다. 다양한 조건에서의 풀화재와 자동차 화재의 성상을 비교하였으며, 실험 결과 각종 화재 조건에서의 연기의 역류, 하강, 터널 내 온도분포 등과 같은 실제 터널 화재상황에서 피해에 영향을 미치는 각종 인자들을 파악하였다.

아트리움 공간에 있어서 연기 유동에 관한 수치해석적 연구 (A Numerical Study of Smoke Movement In Atrium Space)

  • 노재성;유홍선;정연태;김충익;윤명오
    • 한국화재소방학회논문지
    • /
    • 제11권4호
    • /
    • pp.3-14
    • /
    • 1997
  • The smoke filling process for the atrium space containing a fire source is simulated using two types of deterministic fire model : Zone model and Field model. The zone model used is the CFAST(version 1.6) model developed at the Building and Fire Research Laboratories, NIST in the USA. The field model is a self-developed frie field model based on Computational Fluid Dynamic (CFD) theories. This article is focused on finding out the smoke movement and temperature distribution in atrium space which is cubic in shape. For solving the liked set of velocity and pressure equation, the PISO algorithm, which strengthened the velocity-pressure coupling, was used. Since PISO algorithm is a time-marching procedure, computing time si very fast. A computational procedure for predicting velocity and temperature distribution in fire-induced flow is based on the solution, in finite volume method and non-staggered grid system, of 3-dimensional equations for the conservation of mass, momentum, energy, species and so forth. The fire model i.e Zone model and Field model predicted similar results for clear heights and the smoke layer temperature.

  • PDF

표면 자기광 커 효과의 이해 (Understanding the Surface Magneto-optic Kerr Effect)

  • 황찬용
    • 한국자기학회지
    • /
    • 제21권4호
    • /
    • pp.141-146
    • /
    • 2011
  • 지난 20여년간 표면자성 현상의 연구에 가장 도움이 많이 되었던 실험방법중 하나인 표면 자기광 커효과(Surface magneto-optic Kerr effect, SMOKE) 실험 방법을 소개하고자 한다. 예를 들어 단일층의 철막이 강자성이 되는지, 또 큐리(Curie)온도는 bulk와 비교하여 얼마나 떨어져 있는지, 자화 용이축(easy-axis)은 어느 방향인지 등 매우 기본적인 자성박막의 특성은 스핀트로닉스(spintronics) 분야의 연구에 가장 기본적인 정보이다. 표면 자기광 커 효과(SMOKE)는 이러한 물음에 대한 답을 줄 수 있는 매우 효율적인 방법이다.

Magnetic properties of ferromagnetic-antiferromagnetic bi-layers with different spin configuration

  • 김원동;박주상;황찬용;;;박명규;김재영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.304-304
    • /
    • 2011
  • We investigated the effect of different spin direction of anti-ferromagnetic layer on the magnetic properties of ferromagnetic layer in Fe-NiO and Fe-CoO bi-layer systems. For Fe-NiO system, we prepared the clean MgO(001) surface half-covered with 20 nm Ag films as a substrate for magnetic layers. Then we grew NiO wedge layers on the substrate, and added 8 monolayer(ML) Fe layers on the wedge layer. We examined magnetic properties of the bi-layer system using the surface magnetic optical Kerr effect(SMOKE) and X-ray magnetic linear dichroism(XMLD). From SMOKE measurement we observed the coercivity enhancement due to the set-up of anti-ferromagnetic order of NiO films in both of the Fe/NiO/MgO(001) and Fe/NiO/Ag/MgO(001) system. The most remarkable results in our observation is that the coercivity enhancement of Fe/NiO/Ag/MgO(001) is much larger than that of Fe/NiO/MgO(001). XMLD experiments confirmed the out-of-plane spin direction of NiO layers in Fe/NiO/MgO(001) and in-plane spin-direction of NiO layers in Fe/NiO/Ag/MgO(001), and we concluded that the origin of large enhancement of coercivity is due to the strong parallel coupling between Fe layers and NiO layers. We also confirmed that this strong parallel coupling maintained across the thin Ag layer inserted between Fe and NiO layers. For Fe-CoO system, we prepared Fe/CoO/Ag(001) and Fe/CoO/MnO(001) systems and observed much larger coercivity enhancement in Fe/CoO/Ag(001).

  • PDF

경년열화 기간에 따른 원자력발전소용 비안전등급 케이블의 연소특성 분석 (Combustion Characteristics Analysis of a Non-class 1E Cable for Nuclear Power Plants according to Aging Period)

  • 김민호;이석희;이민철;이상규;이주은
    • 한국안전학회지
    • /
    • 제35권5호
    • /
    • pp.22-29
    • /
    • 2020
  • In this study, combustion and smoke release characteristics of a non-class 1E cable for nuclear power plants were investigated according to aging period. The aging was reproduced through an accelerated aging method for interval of 10 years :10, 20, 30 and 40 year, which was applied the Arrhenius equation. The cable was subjected to accelerated aging. In order to understand combustion and smoke release characteristics, the cone calorimeter test was performed according to the standard code of KS F ISO 5660-1. Heat release rate, mass loss rate, average rate of heat emission and smoke production rate were examined through cone calorimeter test. Fire performance index, fire growth index and smoke factor were derived from test results for the comparison of quantitative fire risk. When comparing the fire performance index and the fire growth index, the early fire risk tends to decrease as aging progresses, which might be attributed from the fact that the volatile substances of cables were evaporated. However, when comparing the heat release rate, average rate of heat emission and mass loss rate, which represent the mid and late periods of the fire risk, the values of accelerated aging cables were much higher than those of non-aged cable, which signifies the unstable formation of the char layer resulted in the change in the performance of flame retardants. In addition, the results from the smoke characteristics show that the accelerated aging cables were lager than the non-aged cables in terms of overall fire risk. These results can be used as baseline data when assessing fire risk of cables and establishing fire safety code for nuclear power plants.

장대 수직 환기구를 통한 매연 확산의 모델링 연구 (Modeling of Smoke Dispersion through a Long Vertical Duct)

  • Yoon, Sung-Wook
    • 터널과지하공간
    • /
    • 제13권4호
    • /
    • pp.287-293
    • /
    • 2003
  • 장대 수직 환기구는 지하공간에서 화재 발생시 매연을 지상으로 배출해 내기 위한 필수적 설치물이다. 현재 널리 사용되는 이층 존(zone) 모델은 기본 가정이 제한적임으로 인해 장대 수직 환기구에서의 매연유동을 해석하는데 부적합하다. 그러므로 그 대안으로서 전산유체역학에 기초한 필드 모델의 적용성이 검토되었다. 전산모델의 유효성을 조사하기 위해 이미 발표된 기존의 실험과 유사한 구조를 선택하여 모델링 하였고 그 결과를 서로 비교하였다. 모델링에서 일정한 기준의 질량분율을 일관되게 적용하여 얻어진 매연의 확산 상단면은 실험결과를 바탕으로 구한 매연확산의 경험적 상관관계식과 거의 유사한 속도로 환기구내에서 상승함이 관측되었다. 이것은 다른 연구자들이 수학적 이론으로부터 구한 상관관계식의 결과보다 더 우수한 결과이며 전산유체역학에 기초한 수치모델이 장대형 수직 환기구를 통한 매연확산 연구에 효과적인 도구가 될 수 있음을 보여준다.

WRF-SMOKE-CMAQ(MADRID)을 이용한 한반도 봄철 황사(PM10)의 농도 추정 (An Estimation of Concentration of Asian Dust (PM10) Using WRF-SMOKE-CMAQ (MADRID) During Springtime in the Korean Peninsula)

  • 문윤섭;임윤규;이강열
    • 한국지구과학회지
    • /
    • 제32권3호
    • /
    • pp.276-293
    • /
    • 2011
  • 본 연구에서는 한반도 황사 사례 동안 WRF 기상모델과 SMOKE 배출량모델, CMAQ 및 CMAQ-MADRID 대기질 모델을 이용하여 다양한 황사 발생량 경험식에 대한 $PM_{10}$의 농도를 추정하였다. 특별히 Wang et al.(2000), US EPA 모델, Park and In(2003), GOCART 모델, DEAD 모델의 5가지 황사 발생 경험식이 중국과 몽골 등의 황사 발생량을 추정하기 위해 WRF-SMOKE-CMAQ(MADRID) 모델에 적용되었다. 일기도, 후방궤적 및 위성이미지 분석에 따르면 한반도로의 황사 수송은 절리저기압(위성에서 콤마형 구름)과 관련된 지상 전선의 뒤쪽에서, 그리고 상층 제트류의 발달에 기인한 파의 정체현상과 함께 상층 골에서의 풍속이 하층으로 전이되는 풍하 바람에 의해 생성되었다. 그리고 WRF-SMOKE-CMAQ 모델링 결과, 황사의 시 공간적 분포에 있어서는 Wang et al.(2000)의 경험식이, 평균 편의 및 평균 제곱근 오차에서의 정확도 부분에서는 GOCART 모델의 경험식이 관측값을 보다 잘 모사하는 것으로 나타났다. 또한 Wang et al.의 경험식을 이용한 황사의 연직분포 분석 결과에서 강한 황사 사례(2007년 3월 31에서 4월 1일 $800\;{\mu}g/m^3$ 이상)의 경우는 황사 수송이 한반도 상공 대기 경계층 내를 통과하였기 때문으로, 약한 황사 사례(2009년 3월 16일과 17에 $400\;{\mu}g/m^3$ 이하)의 경우는 황사 수송이 경계층 위를 통과하였기 때문으로 나타났다. 또한 CMAQ 모델과 CAMQ-MADRID 모델에서의 미세먼지($PM_{10}$) 민감도 분석 결과에서는 CMAQ-MADRID 모델이 CMAQ 모델에 비해 한반도를 포함한 동아시아 지역에서 최대 $25\;{\mu}g/m^3$ 정도가 높게 모사되었고, 모델 내 구름 액상과정에 의해서는 최대 $15\;{\mu}g/m^3$ 정도가 제거되는 것으로 나타났다.