• 제목/요약/키워드: Smart Distribution

검색결과 1,070건 처리시간 0.041초

차단기와 리클로져의 통신을 이용한 루프 배전계통의 보호협조 적용시 신뢰도 비교에 관한 연구 (A Study on the Comparison of Reliability for Protective Coordination of Loop Power Distributions using Communication of Circuit Breaker and Recloser)

  • 이희태;문종필
    • 전기학회논문지P
    • /
    • 제60권3호
    • /
    • pp.133-137
    • /
    • 2011
  • The purpose of smart grid is the low $CO_2$ through expansion of renewable energy. To achieve the purpose of smart grid, typical radial power distribution system will be changed to loop power distribution system. The loop power distribution system have many advantages such as low power loss, low voltage drop, and increase of connection of renewable energy. In this paper, the algorithm for minimization of interrupted section of power distribution system is proposed through communication between circuit breaker and recloser in loop power distribution system. The proposed algorithm is proved through case studies about reliability evaluation

DTS를 활용한 광복합 지중 배전계통 실시간 감시시스템 개발 및 성능평가 (A Development and Performance Assessment of On-Line Monitoring System for Optical Fiber Composite Underground Distribution Network using DTS)

  • 조진태;김주용;이학주;조휘창;최명호
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.115-121
    • /
    • 2011
  • Intelligent distribution equipment is inevitable to realize self-healing which is one of smart grid functions in distribution network. Therefore, most of distribution equipment have been developed with self diagnostic sensors. However, it is not effective to construct on-line monitoring system for underground distribution cable because of high cost and low sensitivity. Recently, optical fiber composite cable is being considered for communication and power delivery in order to cope with increasing communication in distribution network. This paper presents the design and performance assessment results of underground cable on-line monitoring system using DTS(Distributed Temperature Sensing) and optical fiber composite underground cable.

IEC 61968과 61970 기반의 배전운영 시스템 제안 (IEC 61968/61970 based Distribution Management System Suggestion)

  • 김태완;임일형;최면송;이승재;권성철
    • 전기학회논문지
    • /
    • 제60권2호
    • /
    • pp.231-238
    • /
    • 2011
  • A role of Distribution Automation System(DAS) is required to be changed from observing and control to complex and various new system including functions which monitoring, control, prediction, operation and management of EMS type according to be gradually Smart Grid of distribution operation system for development of further power system industrial. IEC(International Electrotechnical Commission) published communication standards which interface and data model of distribution operation system to IEC 61968 and of host system like EMS(Energy Management System) to IEC 61970. So far, each standards are emphasizing themselves, but if they are applied by designed integration of the standards, it could be more efficiency system. So, in this paper, integration application of IEC standards and structure of further distribution operation system to use them are proposed by gradually increasing importance of communication protocols, functions and roles in further distribution management system considering Smart Grid.

저압 직류 배전용 양극성 DC-DC 컨버터에 관한 연구 (A Study on Bipolar DC-DC Converter for Low Voltage Direct Current Distribution)

  • 이정용;김호성;조진태;김주용;조영훈
    • 전력전자학회논문지
    • /
    • 제24권4호
    • /
    • pp.229-236
    • /
    • 2019
  • This study proposes a DC-DC converter topology of solid-state transformer for low-voltage DC distribution. The proposed topology consists of a voltage balancer and bipolar DC-DC converter. The voltage and current equations are obtained on the basis of switching states to design the controller. The open-loop gain of the controller is achieved using the derived voltage and current equations. The controller gain is selected through the frequency analysis of the loop gain. The inductance and capacitance are calculated considering the voltage and current ripples. The prototype is fabricated in accordance with the designed system parameters. The proposed topology and designed controller are verified through simulation and experiment.

스마트 배전시스템의 최적 구성 방안에 관한 연구 (A Study on the Optimal Design for Smart Distribution System)

  • 지성호;손준호;송석환;노대석
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2009년도 추계학술발표논문집
    • /
    • pp.834-836
    • /
    • 2009
  • The authors have been discussed the optimal voltage regulation method and on-line real time method using artificial neural networks in the distribution system interconnected with Distributed Generation and Storage(DSG) systems. However, these methods have difficulty in dealing with the random load variations and operation characteristics of a number of DSG systems. To overcome these problems, this paper shows the basic concepts of smart grid system which is considered as one of the power delivery system in the near future and presents an evaluation method on the impacts of customer voltages by the operation of smart grid system. The smart grid system can change the system configuration in a flexible manner by using the static switches and offer the different power qualities in power services through the power quality control centers.

  • PDF

FBG 센서가 내장된 스마트 앵커를 이용한 앵커와 그라우트의 하중전이 측정 (Measurement of Load Transfer between Anchor and Grout using Optical FBG Sensors embedded in Smart Anchor)

  • 서동남;김영상;김재민
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.505-510
    • /
    • 2008
  • FBG Sensor, which is smaller than strain gauge and has better durability and does not have a noise from electromagnetic waves, was adapted to develope a smart anchor. A series of pullout tests were performed to verify the feasibility of smart anchor and find out the load transfer mechanism around the steel wire fixed to rock with grout. Distribution of shear stresses at steel wire-grout interface is assessed from the measured strain distribution by the optical fiber sensors and compared with stress distributions predicted by Farmer's and Aydan's formulas. It was found that present theoretical formulas may underestimate the failure depth and magnitude of shear stresses when the pullout loads increase.

  • PDF

Optimal Control Approach for a Smart Grid

  • Imen Amdouni;Naziha Labiadh;Lilia El amraoui
    • International Journal of Computer Science & Network Security
    • /
    • 제23권12호
    • /
    • pp.194-198
    • /
    • 2023
  • The current electricity networks will undergo profound changes in the years to come to be able to meet the growing demand for electricity, while minimizing the costs of consumers and producers, etc. The electricity network of tomorrow or even the intelligent « Smart Grids » network will be the convergence of two networks: the electricity network and the telecommunications network. In this context falls our work which aims to study the impact of the integration of energy decentralization into the electricity network. In this sense, we have implemented a new smart grid model where several coexisting suppliers can exchange information with consumers in real time. In addition, a new approach to energy distribution optimization has been developed. The simulation results prove the effectiveness of this approach in improving energy exchange and minimizing consumer purchase costs and line losses.

핸드폰 사용이 목과 어깨 근육의 근육활성도와 피로도에 미치는 영향 (The Effect of Using Smart-Phones on Neck and Shoulder Muscle Activities and Fatigue)

  • 박주희;강선영;전혜선
    • 한국전문물리치료학회지
    • /
    • 제20권3호
    • /
    • pp.19-26
    • /
    • 2013
  • The smart-phone has become a necessity for most people. In this study, we determined that using a smart-phone for 20 minutes can cause increased neck and shoulder muscle activities and fatigue. Seventeen healthy male smart-phone users who attended Yonsei University played a smart-phone game for 20 minutes and changes in their bilateral cervical erector spinae and upper trapezius muscle activities and fatigue were measured. To assess muscle activities and fatigue, we used the following variables: the median frequency, the 50th percentile Amplitude probability distribution function (APDF) value (median load), and the discrepancy in the 90th percentile APDF value and the 10th percentile APDF value (APDF range). A paired t-test was used to compare pre-smart-phone-use status with post-smart-phone-use-status. The median frequency of the bilateral cervical erector spinae and the upper trapezius decreased significantly after 20 minutes of smart-phone use (p<.05). In addition, the 50th percentile APDF value of the bilateral cervical erector spinae and the right upper trapezius increased significantly (p<.05). The APDF range of the bilateral cervical erector spinae and the upper trapezius also increased significantly (p<.05). However, the 50th percentile APDF range of the left upper trapezius was not significantly different (p>.05). These findings suggest that using smart-phones for 20 minutes can induce muscle fatigue and increased neck and shoulder muscle activities.

Smart Grid Cooperative Communication with Smart Relay

  • Ahmed, Mohammad Helal Uddin;Alam, Md. Golam Rabiul;Kamal, Rossi;Hong, Choong Seon;Lee, Sungwon
    • Journal of Communications and Networks
    • /
    • 제14권6호
    • /
    • pp.640-652
    • /
    • 2012
  • Many studies have investigated the smart grid architecture and communication models in the past few years. However, the communication model and architecture for a smart grid still remain unclear. Today's electric power distribution is very complex and maladapted because of the lack of efficient and cost-effective energy generation, distribution, and consumption management systems. A wireless smart grid communication system can play an important role in achieving these goals. In this paper, we describe a smart grid communication architecture in which we merge customers and distributors into a single domain. In the proposed architecture, all the home area networks, neighborhood area networks, and local electrical equipment form a local wireless mesh network (LWMN). Each device or meter can act as a source, router, or relay. The data generated in any node (device/meter) reaches the data collector via other nodes. The data collector transmits this data via the access point of a wide area network (WAN). Finally, data is transferred to the service provider or to the control center of the smart grid. We propose a wireless cooperative communication model for the LWMN.We deploy a limited number of smart relays to improve the performance of the network. A novel relay selection mechanism is also proposed to reduce the relay selection overhead. Simulation results show that our cooperative smart grid (coopSG) communication model improves the end-to-end packet delivery latency, throughput, and energy efficiency over both the Wang et al. and Niyato et al. models.