• Title/Summary/Keyword: Small-size building

Search Result 253, Processing Time 0.027 seconds

A Study on the Beijing hotel's Architectural Characteristics of the Early Reform & Opening times in China - Focusing on the cases of high-rise hotels from 1978 until 1992 - (중국 개혁개방 초기 북경호텔의 건축적 특성에 관한 연구 - 1978년부터 1992년까지의 고층호텔 건축사례를 중심으로 -)

  • Gao, Yong;Kim, Hwan-Sik;Lee, Jeong-Soo
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.2
    • /
    • pp.197-205
    • /
    • 2010
  • This study examines for the processes of making a architectural significant issue of 20 cases form of Beijjng's hotel through analyzing the space composition from early the 1950's to 1992 in China. In the methods of analyzing process, We study the literatures, research reports and architectural drawings including the site survey. We hope to establish the principle in morphological characteristics and space composition of Beijing's high-rise hotels through analyzing the plan of these hotels. Finally, We find out the principles after researching. Firstly, Beijing's hotels in China faced on the being difficulties through the process of national development especially in political and economical conditions of country and peoples. Consequently, size of the Beijing's hotel developed with the fact that is complicated from that is single styles focused on the medium-sized one, modernizing popularity and the high-rise hotel buildings appeared plentifully and the form appeared with tall building putting first. Secondly, there are many immanent and interlocking styles in hotel's architectural block plans, many composition styles in big sized hotels, in opposition immanent styles in small sized ones and there are many trend of concourse style in medium sized hotels. To the layout of hotel's room inside of the linear styles are many in big and medium sized hotels.

A Study of Electronic Vehicle Charging Station Structure System Using PV(Photovoltaic) System (PV 시스템을 이용한 전기자동차 충전소의 구조시스템 연구)

  • Lim, Jae-Hwi;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.1
    • /
    • pp.105-112
    • /
    • 2011
  • Fundamental Electric vehicle charge system is urgently needed for commercialization of electric vehicles. Car parking building is equipped with PV system for providing electricity to charge electric vehicles, because it must be charged at least for 30 minutes. In parking lots abroad, electric car charging stations are installed to charge electric cars by the electricity gained from PV systems which are also installed. Also, charge infrastructure construction plans and electric car charging facility support standards are being set and proposed, but there are no cases like abroad of electric car charging stations using PV systems and only electric car charging stations using ordinary electricity are being proposed. Therefore, this paper prepares establishment of domestic electric car charging networks. By researching inside outside solar parking lots and cases of abroad PV system electric car charging stations, and by analysis and comparative analysis of structural systems, structural material, and etc., many cantilever structure and small-size types were installed in PV system electric car charging stations.

Evaluation of CO2 Reduction Effected by GHG Reduction Policy of Vehicle (자동차 온실가스 저감정책에 따른 이산화탄소 저감 효과 평가)

  • Park, Yeon Jae;Kwon, Sang Il;Lee, Jae Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.3
    • /
    • pp.280-288
    • /
    • 2016
  • Greenhouse gas (GHG) emissions have given rise to climate change which is one of the most serious environmental challenges that the world faces today. In response, Republic of Korea has proposed "Low Carbon, Green Growth" as a new economic paradigm accompanying with the ultimate aim of building a sense of responsibility for the environment. Korean government has set the ambitious national GHG emission reduction target which aims 37% reduction in the business-as-usual (BAU) level of 2030. The transportation sector plays a key role in this target. In the transportation sector, the GHG reduction target of 34.3% in the BAU level by 2020 has been allocated in order to consider the industrial specificity. Furthermore, it is known that the GHG reduction in the transportation sector has relatively minimal side effects compared to those of other sectors. In order to meet this national GHG reduction target, Korean government has set $CO_2$ emission regulation of vehicle for 2020. The purpose of this study is to evaluate the reduction effects by the average GHG regulation of vehicles. $CO_2$ emissions, between 2009 and 2013 were analysed by reduction measure such as technology improvement, light-weight, segment shift, diesel vehicle sales. During this period, $CO_2$ of vehicle was reduced every year by 19.9 g/km (i.e., 3.3% reduction per year). $CO_2$ reduction of imported vehicle is greater than domestic vehicle because of segment shift toward small size vehicle and higher diesel vehicle sales.

Documentation of the History of Ok-Cheon Catholic Church by standardized 2D CAD and 3D Digital Modeling (표준화된 2D CAD와 3D Digital Modeling을 이용한 옥천천주교회의 연혁 기록)

  • Kim, Myung-Sun;Choi, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.523-528
    • /
    • 2011
  • Ok-Cheon catholic church has been changed 4 times since it's first construction in 1955. Prior three changes were small ones of windows, doors, roof finish etc. but the last alteration was the extension of it's plan from 一 shape to long cross shape and along with it the size, structure and form of it changed. This history of the church has not been recorded in drawing but only in text with indistinct features not documented. This study makes a new 2D CAD files using layers matched the changes and 3D digital models, these have not only present information but also change informations of the church. They are useful data for effective management, conservation restoration or possible reuse of it.

A Conceptual Design Study for a Spent Fuel Pyroprocessing Facility of a Demonstration Scale (사용후핵연료 파이로 처리공정 실증시설의 개념설계 연구)

  • Yoo, Jae-Hyung;Hong, Kwon-Pyo;Lee, Han-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.233-244
    • /
    • 2008
  • A conceptual design study for a pyroprocesing facility, has been carried out in this study, which is available for the recovery of uranium and transuranic elemental group(TRU), that is, reusable as a nuclear fuel especially in a next generation-type reactor. The scale of this facility has been chosen as 20 kg HM/batch, comparatively small engineering size in order to collect scale-up data for the design of a commercial facility as well as to get operational experience. The spent fuel to be handled in this process is as follows : 3.5 % enriched uranium fuel, 35,000MWd/tU and 5-year cooled. The major items considered in the conceptual study are a building lay-out including various hot cells, safety management of the process operation in conjunction with material balance control, radiation safety, inert atmosphere control in shielded hot cells, and criticality control of uranium and TRU products.

  • PDF

Indoor Air-Conditioning System in building Using Lower Power Wireless Sensor Network (저전력 무선센서 네트워크를 이용한 빌딩 내 환경공조 시스템)

  • Lee, Seung-Chul;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.397-400
    • /
    • 2007
  • Indoor air-conditioning system(IAS) using wireless sensor network serves to reduce the amount of pollution entering the room from outside and also the pollution that is generated indoor. Small-size and lower power wireless sensor node and sensor interface board was designed for indoor air-conditioning system in buildings of offices and industrial establishments. Many sensor nodes forms Ad-hoc network topology using simple forwarding routing to transmit polluting gas concentration data from different rooms to the indoor air-conditioning system. Sensor node analyzes pollution concentration in the each room and air-conditioning system performs to air-distribution and air-inhalation according to room's pollution by regulating the fan of indoor air-conditioning system. To reduce power consumption electrochemical gas sensor was used in the design. Thus the designed system can optimize state of indoor environment. Graphic user interface displays node sate, gas concentration and temperature of each room.

  • PDF

A case study on perforation under Daejeon station building by Front-Jacking method (Front-Jacking공법에 의한 대전역사 하부 관통사례)

  • Kim, Yong-Il;Hwang, Nak-Yeon;Jeong, Du-Seok;Cha, Jong-Hwi;Lee, Nae-Yong
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2006.03a
    • /
    • pp.195-203
    • /
    • 2006
  • The crossing construction under railroad have two methods which are cut and cover and trenchless method. first, cut and cover method is an extremely limited method concerning non-running time. Whereas, trenchless method is free from restriction such as train speed and running time, and has the strong points of safe and rapid construction. Front Jacking method, one of the trenchless methods, is frequently applied recently due to its stability during construction and vantage of assuring schedule reliability. The procedure is that after minimizing interlocking friction with structure and earth pressure due to jacking the small steel tube, pulling the precast box manufactured at the field in the ground using PC strand and hydraulic Jack. This method is able to be applied regardless of section size and length of box and condition of ground. And that is also pro-environmental. This paper presents the case of Daejeon E. W. perforate Road Project applied with the Front Jacking method.

  • PDF

A Study on Green Space Management Planning Considering Urban Thermal Environment (도시 열환경을 고려한 녹지관리방안 수립 연구)

  • Joo, Chang-Hun;Kim, Jeong-Ho;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.23 no.7
    • /
    • pp.1349-1358
    • /
    • 2014
  • This study suggests plan of green space management based on the result of research apprehending the characteristic through sorting types of city thermal environment targeting summer which thermal pollution is the most serious. Considering anthropogenic heat, development level of wind road, thermal environment, as a result of types of thermal environment process, it is appeared 36 types, and 10 types is relevant of this research subject. Type I-1, size of building is large, artificial covering area is wide, and thermal load of anthropogenic heat is high, type II-1, development condition of wind road is incomplete as IIlevel, entering cold air is difficult and thermal management and improvement is needed area. Type III-1, scale is large and it is area of origin of cold air, development level of wind road is mostly favorable, type III-2 is revealed as smaller scale than III-1, and small area of origin of cold air. Type IV, anthropogenic heat is $81{\sim}150W/m^2$, average, but development function of wind road is very favorable. Type V, large area of thermal load and the origin of cold air are distributed as similar ratio, and level of development function of wind road is revealed as II level. According to standard of type classification of thermal environment, as a result of suggesting plan of green space management and biotops area ratio, type I-1 is buffer green space and waterway creation, goal biotops area ratio 35%, type II-1 afforestation in site and goal biotops area ratio 40%, type III-1, preservation plan to display the current function continuously is requested. Type IV suggests afforestation of stream current, and type V suggests quantitative increase of green space and goal biotops area ratio 45%.

A Study on Analysis of Core-Wall Structure Subjected to Torque (비틀림 하중(荷重)을 받는 심벽구조물(心壁構造物)의 해석(解析)에 관한 연구(研究))

  • Kim, Sung Chil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.2
    • /
    • pp.137-144
    • /
    • 1983
  • Core walls for tall building is one of the structures to support lateral load. Since most structural elements used for resisting which ate relatively weak against torsion, it is important to investigate tosional effects in the analysis and design of tall buildings. Rutenberg proposed a more refined theory on the torsional analysis of core walls which can be used when the stiffness of lintel beams are small or large. In this paper a more refined method to analysis the torsion of core wall structures with variable cross sections and being subjected to arbitrarilly distributed load was suggested. To reduce complex and a great number of calculations and to enhance the generality and flexibility of application of this method, the discrete method using transfer matrix formulation was used. Then this method can be easily applied to irregular and variational sections, has no necessity to get particular solution for each of loading conditions, and the maximum size of matrix calculated is $4{\times}4$, which makes this approach more appropriate for design office calculations using comuters of any sizes or even desk calculators.

  • PDF

Estimation on the Future Traffic Volumes and Analysis on Crossing Situation Risk for Gamcheon Harbor (감천항의 장래 교통량 추정 및 교차상태위험 분석)

  • Kim, Jung-Hoon;Gug, Seung-Gi;Kim, Min-Cheol
    • Journal of Navigation and Port Research
    • /
    • v.30 no.8 s.114
    • /
    • pp.617-622
    • /
    • 2006
  • Gamcheon Harbor was developed to cope with increased freight demand of Busan port and supplement function of the north port. Because container wharf is opened to 1997 as well as general wharf, present maximum 50,000DWT class containerships have been incoming and outgoing. However, In Gamcheon port, small size ships such as fishing boats, miscellaneous boats account for 50 percent of the traffic and a public marine products wholesale market that is building on the north wharf will open in 2008. Therefore, it needs to grasp future year traffic volume before establishing operation plan for port management. Also, analysis on crossing situation risk is required because the breakwater entrance in Gamcheon Harbor is narrow and the crossed passing of ship is ever-present at breakwater front. Thus the traffic volume in the future was presumed and quantitative analysis was achieved on crossing situation though simulations with the traffic volume.