• 제목/요약/키워드: Small-scale sewage treatment facility

검색결과 6건 처리시간 0.02초

마을하수도 운영실태 및 개선방안 (A study on the management status of public small-scale sewage treatment facilities and the improvement)

  • 신대윤;배철호
    • 환경위생공학
    • /
    • 제23권4호
    • /
    • pp.55-64
    • /
    • 2008
  • In this study, the management and improvement of public small-scale sewage treatment facilities was investigated. In order to improve the effective management of the operation of small-scale sewage treatment facilities, treatment methods and the problems associated with sewage treatment were carefully addressed based on the data and literature. The investigation results showed that sewer pipes in rural areas should be repaired to prevent sewage from leaking and small-scale operations should be required to have effective management for pollutant loads less than 50%. Also, new methods should be developed for low concentrations of sewage. A law associated with FRP treatment facilities should be established and local governments need to supervise these operations to avoid insufficient and faulty construction. It is recommended that new facilities are built with advanced treatment techniques when the old facility can not comply with nitrogen and phosphorous discharge limits. Moreover, the study shows that nutrient and coliform treatment efficiency improves when abandoned facilities are renovated with the installation of nitrification/denitrification and disinfection processes or another advanced process.

산악지역 소규모하수처리시설의 특성 및 동절기 운영방안에 관한 연구 (A Study on the Characteristics of Small-scale Sewage Treatment Plants in Mountain Area and Operation Plan for Winter Season)

  • 채희준;이지원;길경익
    • 한국습지학회지
    • /
    • 제23권2호
    • /
    • pp.183-188
    • /
    • 2021
  • 소규모 하수처리장의 경우 유입수량의 변동폭이 크고 하수관거 노후화로 인한 불명수 유입 등에 의해 하수처리 운영이 어려운 것으로 보고되고 있다. 특히, 동절기 수온저하로 인한 전반적인 운영문제가 많아 본 연구에서는 산악지역에 위치한 소규모 하수처리시설의 운영현황과 온도에 따른 수질변화를 분석하였다. BOD, COD, SS의 경우 온도에 따라 방류수 수질 농도가 크게 변화하는 것으로 나타났으며, 특히 COD가 많은 영향을 받는 것으로 나타났다. 이에 한시적으로 동절기 수온 저하 대책을 적용하고자 생물반응조 수위를 0.4m 상승시켰으며, 생물반응조 덮개를 설치하고 운영하였을 때 결과를 비교 분석한 결과 유의미한 개선효과가 발생하였다. 이외 동절기 생물반응조 처리효율 저하에 대한 개선방안을 생물반응조 체류시간 연장하는 방안으로 생물반응조 규격을 확대하는 방안, 유량조정조를 신설하고 외부반송하는 방안, 무산소에 산기장치를 설치하여 동절기 비상시 호기조로 사용하는 개선방안을 제시하였다. 본 연구결과는 동절기 소규모 하수처리시설 운영방안에 대한 기초자료로 활용될 수 있을 것으로 판단된다.

재정사업과 민간투자사업의 하수처리장 하수유입률 특성분석 (Comparing the Inflow Rate of Sewage Treatment Plants Invested by the Public Funds or Public-Private Partnership (PPP) Projects)

  • 이원석;조은주;손영규;김지형
    • 한국물환경학회지
    • /
    • 제25권5호
    • /
    • pp.778-784
    • /
    • 2009
  • The purpose of this study is to figure out the differences of the inflow rates of Sewage Treatment Plants (STP), invested by public fund or public-private partnership (PPP). This paper finds that the average ratio of sewage inflow according to facility capacities (medium and small scale STP) was either nearly below 30% or above 100% in the first year. As the size of STP increased, there was decrease in the accuracy of demand assumption. This was because the operation time when the ratio of sewage inflow was uniform was different according to the size of STP, whereby the time was short when the STP were small. The design average ratio of sewage inflow was 10% larger than the real average ratio; this was considered overdesigned. In the case of a plant built by the PPP scheme, the average ratio of inflow of the STP before an abolition of MRG was larger than after the abolition of MRG. This may be explained by moral hazard from too much reliance on MRG. After the abolition of MRG, the demand risk of PPP was shifted from a PPP project to a conventional project.

MSBR 공정에서 전기전도도를 이용한 인 제거 자동제어시스템 - 현장 적용 중심 - (Automatic T-P Coagulation Control System using an EC in the MSBR Process - Full Scale Study -)

  • 장희선;이호식
    • 한국물환경학회지
    • /
    • 제33권1호
    • /
    • pp.90-96
    • /
    • 2017
  • Many sewage treatment plants have applied the advanced technology of chemical coagulant system to remove phosporus in Korea. However there are some problems for the injection of optimum coagulant dosage. In order to solve these problems, the research related to the more cost-effective automatic total phosphorus coagulation control system using an EC(Electrical Conductivity) have been in progress. This study was conducted by the same process and operation method as the Lab-scale for public small town sewage treatment plant. First, it confirmed the correlation among the EC, PO4-P and coagulant dosage in the Lab-scale MSBR(Membrane Sequencing Batch Reactor) process. Next, it analyzed that correlation coefficient of EC and the coagulant dosage was 0.92 in the Full-scale MSBR process. As a result, not only T-P removal efficiency was doubled but also it satisfied the effluent water quality standard in a stable manner. In addition, by applying the automatic control system using the EC, compared to the fixed coagulant injection system the coagulant dosage could be reduced by 28%.

Pilot 규모의 상향류식 충전탑 반응기를 이용한 생활오수의 유기물 및 질소, 인 처리에 관한 연구 (A Study on Removal of Organics, Nitrogen and Phoschorus of Domestic Wastewater in Pilot-Scale Upflow Packed Bed Column Reactor)

  • 선용호
    • KSBB Journal
    • /
    • 제22권4호
    • /
    • pp.191-196
    • /
    • 2007
  • 본 연구는 급속한 산업 발전으로 인해 일어난 많은 수질오염 문제 중 생활하수의 처리방법에 관심을 기울여 생물막 공법을 이용하였는데, 이는 소규모 오폐수 처리장치에서 운전과 유지가 간단하고 활성슬러지 공정보다 넓은 부지를 필요로 하지 않기 때문이다. 생물막 공법 중 생물여상법의 변법을 적용한 Pilot 규모의 상향류식 충전탑형 반응기로 내부의 담체로는 폐토기와 폐비닐을 넣어 혐기조와 호기조를 구성하였고, 생활 오수로는 식당 오수를 이용하여 Lab.-Scale 실험 후 Pilot-Scale로 Scale-up하여 100여일 간에 걸쳐 실험을 수행하였다. 실험은 연속 포기시 일정 HRT에서 유기물과 질소, 인 제거율을 살펴보았다. 실험결과 $BOD_5$와 SS의 평균 제거율은 각각 94.33%와 87.77%로 높은 제거율을 보였으나, $COD_{Cr}$은 81.46%로 목표 제거율 90% 이상에 미치지 못하였고, T-N과 T-P도 각각 71.92%와 21.10%로 예상보다 약간 낮았다. 특히 $COD_{Cr}$와 T-N의 제거율은 지난 Lab.-Scale 때보다 약 10% 정도의 감소를 하여 Pilot-scale에 내외적인 문제가 작용한 것으로 보였다.

수평흐름식 여과기술의 CSOs 적용을 위한 공정 최적화 연구 (A Study on Process Optimization for CSOs Application of Horizontal Flow Filtration Technology)

  • 김재학;양정하;이영신
    • 한국산학기술학회논문지
    • /
    • 제19권2호
    • /
    • pp.56-63
    • /
    • 2018
  • 강우사상이 발생함에 따라 시설용량을 초과하여 미처리된 상태로 방류수계에 직접 배출되는 합류식 관거 월류수(Combimed Sewer Overflows, CSOs) 및 분류식 관거 월류수(Separated Sewer Overflows, SSOs)의 관리는 집중호우가 잦아지는 근래에 들어 그 관리가 더욱 중요해지고 있다. 밀집도가 높은 도심지에 적용성이 유리한 여과기술은 지속적인 개발이 이루어지고 있음에도 불구하고 CSOs에 적용된 사례가 거의 전무한 실정이다. 따라서 본 연구에서는 로프형 섬유여재가 적용된 Pilot 규모의 수평흐름식 여과장치를 CSOs에 적용하기 위해 공정최적화를 목적으로 수행되었다. 연구방법은 인공시료를 적용한 사전연구와 하수를 적용한 현장연구로 구분하여 수행하였다. 인공시료를 적용한 사전연구에서 여재 자체의 손실수두는 약 1.1cm정도로 분석되었고, 선속도 10m/hr 증가에 따라 약 0.1cm 정도의 손실수두 증가를 유발하는 것으로 나타났다. 또한, SS 제거효율은 81.4% 정도로 안정적이었고, 여과지속시간은 6시간 이상 유지되었으며, 공기역세척만으로도 98% 정도의 손실수두 평균 회복율을 보였다. 하수를 적용한 현장평가에서는 여재의 조기폐색을 방지하기 위한 전처리공정으로 벨트 형 미세스크린(450mesh 이상)를 적용했을 때 2시간 내외의 여과지속시간을 확보할 수 있었고, 평균 83.9%의 SS 제거효율을 나타내었다. CSOs 및 SSOs에 여과공정 적용을 위해서는 효율적 측면보다 여과지속시간의 안정적 유지를 위한 수리적 측면을 보완하기 위해서 전처리공정과의 조합이 중요하다는 결론을 얻을 수 있었다. 건기와 비교하여 우기의 유입하수 수질은 다소 낮은 보였으며, 이는 분류식 관거 비율이 높은 배수구역의 특성 때문인 것으로 추정된다. 또한, 우기와 건기의 유입수질에 따른 제거효율 차이는 미미하였다.