• Title/Summary/Keyword: Small-Disturbance

Search Result 330, Processing Time 0.029 seconds

Stability of the K rm n Boundary Layer Flow (Karman 경계층 유동의 안정성에 관한 연구)

  • 황영규;이윤용
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.771-781
    • /
    • 2000
  • The Karman boundary-layer, has been numerically investigated for the disturbance wave number, wave velocity, azimuth angle and radius (Reynolds number, Re). The disturbed flow over rotating disk can lead to transition at a much lower Re than that of the well-known Type 1 mode of instability. This early transition is due to the excitation of the Type II mode. Presented are the neutral stability results concerning these modes by solving new formulated vorticity equations with consideration of whole convective terms. When the present numerical results are compared with the previously known results, the value of critical Re corresponding to Type I is moved from Rec,! =285.3 to 270.2 and the value corresponding to Type II is from $Re_{c,2}$=69.4 to 36.9, respectively. Also, the corresponding wave number is moved from $k_1$ =0.378 to $k_1$ =0.389 for Type I; from $k_2$ =0.279 to $k_2$=0.385 for Type II. For Type II, the upper limit of wave number and azimuth angle is $k_U$=0.5872,$varepsilon_U=-18^{\circ}$ , while its lower limit is$k_L$ =0.05, $varepsilon_L=-27^{\circ}$ This implies that the disturbances will be relatively fast amplified at small Re and within narrow bands of wave number compared with the previous results.

  • PDF

Development of Integrated Simulation Tool for Jitter Analysis

  • Lee, Dae-Oen;Yoon, Jae-San;Han, Jae-Hung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.1
    • /
    • pp.64-73
    • /
    • 2012
  • Pointing stability of high precision observation satellites must satisfy the stringent requirements to perform at a designed level. As even a small vibrational disturbance can result in severe degradation of the optical performance, the effects of inorbit vibrational environment on the performance of optical payload must be predicted and analyzed in the design phase in order to ensure that the requirements imposed on the payload are fully met. In this paper, an integrated framework for the evaluation of the performance of optical payloads is developed. The developed simulation tool comprises of the reaction wheel induced disturbance model, state space model of a structure in modal form and Cassegrain reflector model. The performance degradation of the optical system due to jitter is expressed by using modulation transfer function (MTF) and image simulation. Moreover, vibration isolator model is also added to show the effectiveness of using a vibration isolator for the elimination of the effects of jitter in the acquisition of an image.

Two case of Stroke patients assume an aspect of Cheiro-oral Syndrome (수구증후군 양상을 보인 뇌졸중 환자 2례)

  • Kang, Gu-Hyeng;Yong, Hyung-Soon;Jung, Yong-Soo;Ko, Seong-Gyu;Park, Kyoung-Hoon
    • The Journal of Internal Korean Medicine
    • /
    • v.22 no.2
    • /
    • pp.257-262
    • /
    • 2001
  • Cheiro-oral syndrome is characterized by a partial sensory disturbance in one hand and the ipsilateral oral comer. Its lesion is on the sensory track, and it is comparatively small. Most studies are case studies. These studies reported less than 10 cases. We studied two cases. In one, we observed intracranial hemorrhage involving left thalamus, posterior limb of internal capsule about 5cc in brain computed tomographic scan. The case was shown paresthesia of the right hand and ipsilateral comer of the mouth. The patient also complained about disturbing dysstereognosis and disorder of graphaesthesia. In the other case, we observed nodular calcification at the left basal ganglia external capsule in brain computed tomographic scan. The patient also complained about dysesthesia of the right thumb and index finger, fatigue and verbal disturbance. These cases appeared to be typical strokes in the acute phase, but after acute phase, they had dysethesia in the hand and periord for three months.

  • PDF

Variation of Eigenvalues of the Multi-span Fuel Rod due to Periodic Flow Disturbance by the Flow Mixer (혼합날개의 주기적 유동교란에 따른 다점지지 연료봉의 고유치변화)

  • Lee, Kang-Hee;Woo, Ho-Kil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.3
    • /
    • pp.215-222
    • /
    • 2010
  • Long and slender body, like a fuel rod, oscillating in axial flow can be unstabilized even by the small cross flow which can be activated by the flow mixer or turbulent generator. It is important to include these effects of flow disturbance in dynamic stability analysis of nuclear fuel rod. This work shows how eigen frequency of a multi-span fuel rod can be changed by the swirl flow, which is discretely generated by a flow mixer. By solving a state-space form of the eigenvalue equation for a multi-span fuel rod system, the critical velocity at which a fuel rod becomes unstable was calculated. Based on the simulation results, we evaluated how stability of a multi-spanned nuclear fuel rod with mixing vanes can be affected by the coolant flow in an operating reactor core.

An Experimental Research of Servo Valve Offset Correction Method of Hydraulic Actuator (유압식 구동장치의 서보밸브 오프셋 보정 방법에 관한 실험적 연구)

  • Ban, Joon Hyeok
    • Journal of Drive and Control
    • /
    • v.16 no.2
    • /
    • pp.72-79
    • /
    • 2019
  • Despite the development of electronic components and microprocessors, hydraulic actuators are still being applied in various applications. In some applications, there is a desire to apply a hydraulic actuator with a relatively small position error to the system. Various studies have been conducted to reduce the position error of hydraulic actuators. In this paper, the position error of the hydraulic actuator when the hydraulic oil pressure is supplied is defined as the offset generated by the servo valve, and the method for correcting the servo valve offset has been studied. A method for compensating the servo valve offset was proposed and it was verified through experiments that the position error of the hydraulic actuator was reduced. We also compared the servo valve offset correction method and controller using the PID control and disturbance observer used to reduce the position error of the hydraulic actuator. No-load test and load test were performed to confirm the performance of the servo valve offset correction method. The results of the study were compared with those obtained by using the disturbance observer and PID control.

Low Speed Thrust Characteristics of a Modified Sonic Arc Airfoil Rotor through Spin Test Measurement

  • Lee, Jang-Chang
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.3
    • /
    • pp.317-322
    • /
    • 2012
  • The low speed aerodynamic characteristics for a modified sonic arc airfoil which is designed by using the nose shape function of sonic arc, the shape function of NACA four-digit wing sections, and Maple are experimentally investigated. The small rotor blades of a modified sonic arc and NACA0012 airfoil are precisely fabricated with a commercially available light aluminum(Al 6061-T6) and are spin tested over a low speed range (3000rpm-5000rpm). In a consuming power comparison, the consuming powers of NACA0012 are higher than that of modified sonic arcs at each pitch angle. The measured rotor thrust for each pitch angle is used to estimate the rotor thrust coefficient according to momentum theory in the hover state. The value of thrust coefficients for both two airfoils at each pitch angle show almost constant values over the low Mach number range. However, the rotor thrust coefficient of NACA0012 is higher than that of the modified sonic arc at each pitch angle. In conclusion, the aerodynamic performance of NACA0012 is better than that of modified sonic arcs in the low speed regime. This test model will provide a convenient platform for improving the aerodynamic performance of small scale airfoils and for performing design optimization studies.

The Generative Mechanism of Cloud Streets

  • Kang Sung-Dae;Kimura Fujio
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.1 no.2
    • /
    • pp.119-124
    • /
    • 1997
  • Cloud streets were successfully simulated by numerical model (RAMS) including an isolated mountain near the coast, large sensible heat flux from the sea surface, uniform stratification and wind velocity with low Froude number (0.25) in the inflow boundary. The well developed cloud streets between a pair of convective rolls are simulated at a level of 1 km over the sea. The following five results were obtained: 1) For the formation of the pair of convective rolls, both strong static instability and a topographically induced mechanical disturbance are strongly required at the same time. 2) Strong sensible heat flux from the sea surface is the main energy source of the pair of convective rolls, and the buoyancy caused by condensation in the cloud is negligibly small. 3) The pair of convective rolls is a complex of two sub-rolls. One is the outer roll, which has a large radius, but weak circulation, and the other is the inner roll, which has a small radius, but strong circulation. The outer roll gathers a large amount of moisture by convergence in the lower marine boundary, and the inner roll transfers the convergent moisture to the upper boundary layer by strong upward motion between them. 4) The pair of inner rolls form the line-shaped cloud streets, and keep them narrow along the center-line of the domain. 5) Both by non-hydrostatic and by hydrostatic assumptions, cloud streets can be simulated. In our case, non-hydrostatic processes enhanced somewhat the formation of cloud streets. The horizontal size of the topography does not seem to be restricted to within the small scale where non-hydrostatic effects are important.

  • PDF

A Study of Transonic Premixed Combustion in a Diverging Channel Using Asymptotic Analysis (점근해석을 이용한 확대형 채널 내의 천음속 예혼합 연소에 관한 연구)

  • Lee, Jang-Chang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.8
    • /
    • pp.75-83
    • /
    • 2005
  • A steady transonic dilute premixed combustion in a diverging channel is investigated by using asymptotic analysis. This model explores the nonlinear interactions between the near-sonic speed of the flow, the small changes in geometry from a straight channel, and the small heat release due to the one-step first-order Arrhenius chemical reaction. The reactive flow is described by a nonhomogeneous transonic small-disturbance (TSD) equation coupled with an ordinary differential equation for the calculation of the reactant mass fraction in the combustible gas. Also the asymptotic analysis reveals the similarity parameters that govern the reacting flow problem. The results show the complicated nonlinear interaction between the convection, reaction, and geometry effects and its effect on the flow behavior.

Clinical Usefulness of Digital ECG Recorder in Dogs : 4 Cases (디지털 심전도기의 임상적 적용 예 : 4 증례)

  • Moon, Hyeong-Sun;Lee, Seung-Gon;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.218-224
    • /
    • 2007
  • Digital electrocardiogram (ECG) recorders are rapidly replacing to conventional paper ECG recorders. Digital ECG recorders have several advantages over conventional type ECG recorders, including better capability for data storage, better portability and better applicability in clinical settings. In this study, we presented 4 case studies related to cardiac rhythm disturbances, which were diagnosed and managed using a digital ECG recorder.

A syudy on the correlativity of EAV (Electroacupuncure acc.Voll)'s measurement and symptoms of a disease (EAV의 측정치(測定値)와 병증유형(病症類型)의 상관성(相關性)에 관(關)한 연구(硏究))

  • Han, Ju-Seok;Song, Il-Byung
    • The Journal of Internal Korean Medicine
    • /
    • v.15 no.2
    • /
    • pp.383-417
    • /
    • 1994
  • By making use of the EAV(Electroacupuncture acc. Voll) combined meridian theory of oriental medicine with electronics which was contrived to recognize the physiological and pathological changes of human body, the following conclusions were made in comparison with EAV measurements and types of symptoms(anxiety & headache, fatigue, palpitation, dizzness, abdominal distension. nausea, gastric disturbance. constipation & diarrhea, fatty liver, cva), QSCC, and blood type test. 367 patients including 124 with nervous gastrointestinal problems were selected for this research. 1. From the point of variance of the tested patients 124 nervous gastrointestinal patients, Liver meridian and Spleen meridian showed hyperenergia and Large intestine meridian, Circulation meridian, Triple warmer meridian showed hypoergia 2. In each symptom as the nervous gastrointestinal symptom Liver meridian showed hyperenergia, Large intestine meridian, Circulation meridian and Triple warmer meridian showed hypoergia . 3. In an objective comparison with other symptoms, firstly among the headache & anxiety group left Gall Bladder, Triple warmer and Stomach meridian showed remarkable hypoergia, secondly among fatigue group showed hypoergia in Triple warmer meidian and hyperenergia of Stomach meridian. and thirdly among palpitation group showed hypoergia of Kidney meridian, and lastly among dizzness group showed hypoergia of Gall Bladder, Stomach, Circulation and Small intestine meridian. 4. All of gastric disturbance, nausea, abdominal distention, constipation and diarrhea group showed hyperenergia in Stomach meridian and Spleen meridian. gastric disturbance group showed remarkably hypoergia in Circulation. Small intestine, Lung and Large intestine meridian. Nausea group showed hypoergia in Gall bladder and Urinary bladder meridian. Abdominal distenton group showed hypoergia of Large intestine. Constipation and diarrhea group showed hypoergia of Kidney and left Circulation meridian. 5. Fatty liver group showed hyperenergia of Liver meridian of 83.3%, Gall Bladder, Stomach and Spleen meridian. Urinary bladder and Kidney meridian showed hypoergia 6. CVA group showed hyperenergia in Liver and Circulation meridian. 7. Blood type in typical classification had no significant bearings on each other. 8. QSCC for the attempt of objective materials of constitutional diagnosis had no correlativity in comparison with EAV measurements. In conclusion EAV is thought be used as a diagnostic method in oriental medicine and further research is needed regarding it can be used as a useful method for verifying the characteristics and early finding of symptoms.

  • PDF