• 제목/요약/키워드: Small wind turbine system

검색결과 150건 처리시간 0.027초

과풍속 출력 제한형 소형 풍력 발전장치 개발 (Development of the Furling Control Type Small Wind Turbine System)

  • 최영철;김철호;이현채;서영택;한용운;송정일
    • 한국정밀공학회지
    • /
    • 제29권6호
    • /
    • pp.693-701
    • /
    • 2012
  • In this study, a small wind turbine airfoil specialized for national wind condition was designed in order to develop the furling control type HAWT. And then a flow analysis was carried out based on the blade drawing which was designed to characterize of the developed airfoil. The result of the flow analysis showed that the torque on the 3 blades was 180.23N.m. This is equivalent to an output power of 5.66kw and an output efficiency of 0.44. Then we produced and constructed a 3kW - furling control type HAWT by getting the system unit design technology such as the specialized furling control device. By operating this turbine, we could get 3kW of the rated power at a wind speed of 10.5m/s through the ability test. Cut-in wind speed was 2m/s, generator efficiency was 92% at the rated power output. Sound power level was 87.2dB(A). Also we observed that the output power was limited to 10.5m/s with furling system operation.

소형 풍력발전 시스템을 위한 CRIO 기반의 실시간 제어 시스템 설계 및 다양한 형태의 MPPT 알고리즘 성능 비교 분석 (Design of CRIO-based real-time controller for small-sized wind turbine generating system and comparative study on performance of various MPPT algorithms)

  • 김수진;김병문;김성호
    • 한국지능시스템학회논문지
    • /
    • 제21권1호
    • /
    • pp.55-61
    • /
    • 2011
  • 10KW 이하의 소형 풍력 발전 시스템은 언덕이나, 공원, 도시와 같은 협소한 지역에 유연하게 설치될 수 있다는 장점으로 인해 신재생에너지 분야에서 지속적인 연구/개발이 이루어지고 있다. 소형 풍력 발전기는 낮은가격, 고신뢰도 및 고성능이 중요시되기 때문에 최대 전력을 추종하기 위한 다양한 기법이 요구된다. 일반적으로 제어기의 출력은 DC 부하에 전원을 공급하기 때문에 48V 배터리에 연결되어 동작된다. 본 논문에서는 소형 풍력 발전 시스템을 위한 FPGA 기반 MPPT 제어기를 제안하고자하며, 제안된 시스템에서의 다양한 MPPT 알고리즘의 성능을 검증하기 위해 NI 사에서 제작된 Compact-RIO 컨트롤러를 사용하였다.

사보니우스 소형풍력터빈 수치해석용 격자시스템 평가 (Evaluation of a Grid System for Numerical Analysis of a Small Savonius Wind Turbine)

  • 김철규;이상문;전석윤;윤준용;장춘만
    • 한국수소및신에너지학회논문집
    • /
    • 제27권5호
    • /
    • pp.547-553
    • /
    • 2016
  • This paper presents the effect of a grid system on the performance of a small Savonius wind turbine installed side-by-side. Turbine performance is compared using three different grid systems; tetrahedral grid having a concentrated circular grid around turbine rotors, the tetrahedral grid having a concentrated rectangular grid around turbine rotors and the symmetric grid having a concentrated tetrahedral grid near the turbine rotor blades and a hexahedral grid. The commercial code, SC/Tetra has been used to solve the three-dimensional unsteady Reynolds-averaged Navier-Stokes analysis in the present study. The Savonius turbine rotor has a rotational diameter of 0.226m and an aspect ratio of 1.0. The distance between neighboring rotor tips keeps the same length of the rotor diameter. The variations of pressure and power coefficient are compared with respect to blade rotational angles and rotating frequencies of the turbine blade. Throughout the comparisons of three grid systems, it is noted that the symmetric grid having a concentrated tetrahedral grid near the turbine rotor blades and a hexahedral grid has a stable performance compared to the other ones.

케이블 지지된 풍력발전기 타워 진동계의 변수 분석 (Parametric Study of a Wind Turbine Tower Vibration System Supported by Guy Cables)

  • 박무열;김석헌
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1165-1169
    • /
    • 2006
  • Vibration characteristics of a small stand alone W/T(wind turbine) system are experimentally and theoretically investigated. Vibration resonance of the tower-cable system is monitored and the data are analysed with the analytical results. To predict the resonance speed of the cable supported WIT. Rayleigh-Ritz method is applied to the tower-guy cable coupled system. Parametric study on the relation of the cable tension. cable elasticity and resonance frequency is carried out. Results of the study are utilized to design the stable structure of small size wind turbines which consist of a pivoted tower and guy cables.

  • PDF

풍력발전기 주축 및 날개 부하 측정시스템의 보정 및 불확실성 해석 (A Calibration and Uncertainty Analysis on the Load Monitoring System for a Low Speed Shaft and Rotor Blade of a Wind Turbine)

  • 박무열;유능수;남윤수
    • 대한기계학회논문집A
    • /
    • 제30권5호
    • /
    • pp.560-567
    • /
    • 2006
  • The exact load measurements for the mechanical parts of a wind turbine are important step both fur the evaluation of a specific wind turbine design and for a certification process. A common method for a mechanical load measurement is using a strain gauge sensing. Two main problems ought to be answered in order for this method to be applied to the wind turbine project. These are strain gauge calibration and non-contact signal transmission from the strain gauge output to a load monitoring system. This paper suggests reliable solutions fer these two problems. A Bluetooth, a short range wireless data communication technology, is used to solve the second problem. The first one, the strain gauge calibration methodology for a load measurement in a wind turbine application, is fully explained in this paper. Various mechanical loadings for a strain gauge calibration in a wind turbine load measurement are introduced and analyzed. Initial experimental results which are obtained from a 1 kW small size wind turbine are analyzed, and the uncertainty problem in estimating mechanical loads using a calibration matrix is fully covered in this paper.

6kW 풍력발전기의 출력곡선 측정 (Power Curve Measurements on the 6kW Wind Turbine)

  • 유능수;남윤수;이정완;조주석
    • 산업기술연구
    • /
    • 제25권B호
    • /
    • pp.149-157
    • /
    • 2005
  • The power performance monitoring system for a small class of wind turbine is established. The wind turbine power performance characteristics are determined by measured power curve and the estimated annual energy production (AEP). The measured power curve is determined by collecting simultaneous measurements of wind speed and power output at the test site under varying wind conditions. In order to determine the power performance characteristics of the wind turbine accurately, the data are of sufficient quantity and quality shall be corrected according to defined criteria. In this study, the 6kW wind turbine made by Germany Inventus GmbH is examined.

  • PDF

50kW 풍력발전기의 출력 성능에 관한 연구 (A study of Power Performance for 50kW Wind Turbine)

  • 김형길;공정식;권기진;오진훈;문채주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1068-1069
    • /
    • 2015
  • Wind turbines have an enormous potential for decentralized electricity generation. In recent years, there has been an increasing worldwide interest in small/medium wind systems. This paper presents the results of power performance testing conducted on a 50 kW turbine located in Yeonggwang test-bed. The turbine system is a pitch, active yaw, variable speed, upwind, three blade with a direct drive PMSG. This thesis covers the operation of variable speed wind turbines with pitch-yaw control. The system considered is controlled to generate maximum energy while minimizing loads. The data include power, wind speed, and direction from meteorological towers, and nacelle anemometer readings and output from turbine. The analysis concentrates on the effect of the load on the power-wind speed curve of the turbine.

  • PDF

공동주택에서의 소형풍력발전시스템 적용에 관한 연구 (A Study on the Application of Small Wind Power System in Apartment Housing)

  • 박진철;경남호
    • 한국태양에너지학회 논문집
    • /
    • 제23권2호
    • /
    • pp.21-34
    • /
    • 2003
  • This study aims to present the applicability of wind turbine generator system to urban buildings for the utilization of clean renewable energy. The results are as follows; According to the wind resource analysis, it has been found that small sized wind power system can be viable for buildings application due to the amplification of wind velocity around buildings or building clusters, in spite of low mean velocity of 2-3m/s in Seoul and Kyunggi urban areas. But planners must perform micrositing analysis around building so that wind turbine can be located at high velocity zones. The system must be designed to avoid obstacles preventing prevailing wind in buildings. It should be recognized that wind speeds are changing depending on the height and length from buildings. The wind power system can be used as a symbol of landmark which shows a sustainable architecture from the scenary Itself A case study for apartment building in urban showed that wind power systems can be applicable in two kinds of place, rooftops and ground levels. Especially, the wind power systems must be carefully positioned so that wind resources do not decrease when it is installed at ground levels. and according to life cycle cost analysis, adaption of new small win4 power systems to buildings were proved to produce a profit if it is considered the expense of environment improvement and the wind speed increasing according to rise of building height. This research will ultimately achieve green architecture that preserves nature and at the same time provides pleasant environment to humans, and will play a great role in establishing the environment-preserving sustainable architecture of the 21th century.

소형 풍력발전 시스템용 복합재 블레이드의 설계 및 시험에 관한 연구 (A Study on Design and Test for Composite Blade of Small Scale Wind Turbine System)

  • 공창덕;방조혁;박종하;오경원
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 추계학술발표대회 논문집
    • /
    • pp.125-130
    • /
    • 2004
  • This study proposes a development for the l-kW class small wind turbine system, which is applicable to relatively low wind speed region like Korea and has the variable pitch control mechanism. In the aerodynamic design of the wind turbine blade, parametric studies were carried out to determine an optimum aerodynamic configuration which is not only more efficient at low wind speed but whose diameter is not much larger than similar class other blades. A light composite structure, which can endure effectively various loads, was newly designed. In order to evaluate the structural design of the composite blade, the structural analysis was performed by the finite element method. Moreover both structural safety and aerodynamic performance were verified through the prototype test.

  • PDF

도시형 풍력발전 시스템의 효율적 에너지 관리를 위한 인공신경망 기반 최대 전력점 추종 알고리즘 개발 (Design of Neural Network based MPPT(Maximum Power Point Tracking) Algorithm for Efficient Energy Management in Urban Wind Turbine Generating System)

  • 김승영;김성호
    • 한국지능시스템학회논문지
    • /
    • 제19권6호
    • /
    • pp.766-772
    • /
    • 2009
  • 일반적으로 풍력발전은 광범위한 영역에 지속적인 바람을 요구하는 대형 시스템 위주로 개발이 되어왔다. 그러나 소형 풍력발전 시스템은 사용자에게 보다 친숙하고, 대형에 비해 보다 광범위한 적용이 가능하다는 점 때문에 최근 이에 대한 관심이 증가되고 있는 실정이다. 이에 본 연구에서는 배터리 충전에 효과적으로 도입될 수 있는 도시형 풍력발전을 위한 프로토타입 시스템에 대해 기술하며, 프로토타입 시스템에 효과적으로 도입될 수 있는 인공신경망 기반의 최대 전력점 추종 알고리즘을 제안하고자 한다. 또한 Matlab기반의 다양한 시뮬레이션 및 실제 시스템 설계를 통해 제안된 기법의 유용성을 확인하고자 한다.