• 제목/요약/키워드: Small sewerage system

검색결과 14건 처리시간 0.031초

하수도 업무추진체계 개선 (Improvement of Sewerage Treatment System)

  • 이찬희
    • 수도
    • /
    • 제24권5호통권86호
    • /
    • pp.5-15
    • /
    • 1997
  • This year the Ministry of Environment(MOE) made a fifth amendment to the Sewerage Act, which was enacted in August 1966. The first objective of this amendment is to introduce small public sewerage system that is designed to treat wastewater produced in rural areas. Before small public sewerage system was introduced to the Act through this amendment, only urban areas were covered by public sewerage system. Because small sewerage system was introduced, wastewater generated in urban areas as well as rural areas can now be treated by public sewage treatment plants. In addition to this, some authorities on sewerage affairs were moved from the MOE to local governments by this amendment in order to enhance the power and responsibility of local governments in relation to sewerage affairs. Also, this amendment enabled local governments to entrust the authority to establish and manage sewage treatment plants to private companies, and enabled the MOE to organize an advisory committee on sewerage to review economic and technical aspects ofsewage treatment plants. This amendment went into effect September 8, 1997.

  • PDF

SBR을 이용한 소규모 오수처리시설에 관한 연구 (A study on the small sewerage system using SBR process)

  • 박민정;김동석
    • 한국환경과학회지
    • /
    • 제12권4호
    • /
    • pp.427-437
    • /
    • 2003
  • An evaluation of the application of SBR and biofilm en small sewerage system was conducted. A newly developed small sewerage system, using SBR, was successfully applied to the nutrient treatment using municipal wastewater. The system was consisted of 6 compartments. Two systems, with SBR (A type) or without SBR (B type), were compared by several parameters (COD, SS, T-N, NH$_4$$\^$+/-N, NO$_3$$\^$-/-N, NO$_2$$\^$ -/-N, alkalinity, pH, DO) in all experimental periods. Also, the time variation of several parameters (DO, pH, NH$_4$$\^$+/-N, NO$_3$$\^$-/-N NO$_2$$\^$-/-N) was examined in a SBR applied sewerage system. T-N removal efficiency of B type Was higher than that Of A type by the effect of nitrification and denitrification even though the COD removal efficiencies were similar. In aeration stage, the pH was decreased from 6.4 to 6.3 within 1 h and increased to 6.65 at the end of aerobic stage, and pH was decreased to 6.2 in non-aeration stage, and these phenomena were explained. The effects of nitrification and denitrification were compared in A type and B type sewerage system, and the typical nitrification and denitrification were observed in B type sewerage system.

우리나라 적합 하수도시설 및 관리방안 (Appropriate Sewerage Systems for Korea)

  • 이상은
    • 환경위생공학
    • /
    • 제7권2호
    • /
    • pp.37-52
    • /
    • 1992
  • Since the first sewage treatment plant was constructed in 1976, the sewerage systems of Korea have been rapidly expanded. As of the end of 1991, 22 sewage treatment plants with total capacity of 5.4 million tons/day are in operation which is equivalent of 3395 total daily sewage generation. Total extension of sewer 39.534 km in 1990 which is 55% of the target extension for the year 2001. However, the most sewage treatment plants employ activated sludge process which may not be suitable for medium and/or small scale plants. The poor existing sewer systems do not effectively collect and transport sewage to adversely affect the function of sewage treatment plant. To select the appropriate treatment system, the cities are classified into 3 categories such as large and medium size inland cities, small size cities and coastal cities. Considering the criteria suggested during this study, appropriate treatment processes were selected for each category. Conventional activated sludge process and step aeration process were found to be the most appropriate for big inland cities while biological nutrient removal processes should be considered for the cities discharge the effluent to lakes or reservoirs. RBC or Oxidation Ditch process might be appropriate for the medium size cities while several processes which do not require skilled operation and maintenance were suggested for the small cities. Ocean discharge after primary treatment can be considered for some east coast cities, Appropriate methodology to rehabilitate the existing sewers and strategy to convert combined sewer system to separate sewer system were proposed. This paper also include the appropriate management system for industrial wastewater, sludge and nightsoil.

  • PDF

농촌 지역에서 유입 유량이 소규모 하수처리장 처리 효율에 미치는 영향 (Effect of sewage flow on treatment efficiency of small scale wastewater treatment plant in rural community)

  • 임지열;길경익
    • 한국습지학회지
    • /
    • 제18권3호
    • /
    • pp.267-274
    • /
    • 2016
  • 농촌 지역 하수도 보급은 하천, 호소 및 습지와 같은 수계 수질 보호를 위해서 반드시 필요하다. 또한 안정적인 소규모 하수처리장 운영을 위해서는 유입 유량과 농도의 변화가 큰 소규모 하수도 특성을 고려해야 한다. 본 연구에서는 봉화군 18개의 소규모 하수처리장 운전 결과를 통해 유입유량비 (유입 유량 / 설계 유량) 특성, 소규모 하수처리장 처리 효율에 미치는 영향과 적정 유입유량비 산정에 관한 연구를 수행하였다. 분석 결과 유입유량비는 여름철에 가장 높은 것으로 나타난 반면, 유입 하수 농도는 가을철과 겨울철에 높은 것으로 나타났다. 유입유량비가 증가할수록 처리 효율이 증가하는 경향을 보였으며, 영양염류 처리 효율이 유기물과 부유물질 처리 효율에 비해 민감한 영향을 받는 것으로 나타났다. 안정적인 소규모 하수처리장 처리 효율을 위해서는 유입유량비 0.8 이상을 유지해야 할 것으로 판단된다.

국내 하수처리시설 에너지 등급 평가를 위한 ENERWATER의 적용 가능성에 관한 연구 (A Study on the Applicability of ENERWATER for Evaluation of the Energy Consumption Label of WWTPs in Korea)

  • 박민오;이호식
    • 한국물환경학회지
    • /
    • 제38권5호
    • /
    • pp.231-239
    • /
    • 2022
  • In this study, we applied ENERWATER to evaluate the energy consumption labeling of wastewater treatment plants in Korea using the Korea sewerage statistics data. The results showed that the energy label status was excellent in the SBR process for small and medium-scale wastewater treatment plants and the A2O process for large-scale wastewater treatment plants. The energy labeling of wastewater treatment plants of 50,000 tons capacity was excellent. The statuses of metropolitan cities and Jeollanam-do province were excellent. We analyzed the effects of renewable energy on wastewater treatment plants' energy consumption and found out that digestion gas for large-scale plants and photovoltaic energy for small-scale plants were effective in improving energy labeling. In addition, we compared the energy labels of four wastewater treatment plants in "Z" city and wastewater treatment plant "X" had the best energy label, and the wastewater treatment plants "V" and "Y" had to be selected as priorities for the energy diagnosis and improvement project. In a comprehensive conclusion, the applicability of ENERWATER was confirmed based on sewage statistics data and labeling can be used to set priorities for the energy diagnosis and improvement project.

소규모 오수처리를 위한 전기화학적 방법에 의한 대장균 소독에 관한 연구 (A Study on Escherichia Coli Disinfection by the Electrochemical Method for Small Sewerage System)

  • 박영식;정노성;김동석
    • 한국환경과학회지
    • /
    • 제16권4호
    • /
    • pp.441-447
    • /
    • 2007
  • This study was carried out to investigate the effect of electrochemical (EC) disinfection of artificial wastewater contaminated by Escherichia coli culture. Circulated batch type electrochemical disinfection system using three plates electrodes was used. Also, the several factors (pH, ORP, DO, temperature, current, conductivity) were measured in order to investigate the fundamental design factor in the EC disinfection system. It was demonstrated that the EC process was highly effective for wastewater disinfection. At the constant voltage, the disinfection efficiency was increased according to time. The disinfection efficiency and current increased as the increase of voltage. The variation of conductivity was a little related to the variation of CFU (colony forming units). The differences in disinfection efficiency according to the ice pack and the variation of electrodes were not occurred. The EC disinfection efficiency and current increased according to the increase of circulating flow rate.

재현기간별 확률 향우강도식 산정에 관한 수문통계학적 고찰-청주 지방을 중심으로- (A Review for Caluculation of the Formula for Probable Rainfall Intensities Following Return Periods in the Hydrological Statistics. -On Cheong-Ju district-)

  • 이순혁
    • 한국농공학회지
    • /
    • 제17권3호
    • /
    • pp.3848-3859
    • /
    • 1975
  • The author attempted to find most suitable formulas for probable rainfall intensities with analysis and consideration for characteristics of rainfall intensities according to the short and long period return periods at Cheong-Joo district. Above mentioned formulas induced by this study can be contributed to the credibility of runoff estimation for urban sewerage system, drainage works in small catchment area and embankment works in the rivers. The results of this study are summarized as follows: 1 Calculation values by Gumbel-Chow method were selected as a mean values for the calculation of probable rainfall intensities according to return periods in the short period. 2. Calculations for probable rainfall intensities for long period are based upon to the result by Iwai's method. Talbot type, {{{{I= {a} over {t+b} }}}} is confirmed as a most suitable formula for probable rainfall intensities among calculation methods in the short periods at Cheong-Joo district. 4. Specific coefficient method, I24=RN24${\beta}$N was selected as a means of calculation for suitable formulas of probable rainfall intensities according to return periods in case of long period. 5. Runoff estimation with high credibility by rational formula can be anticipated by establishment for the most suitable probable rainfall intensities at Cheong-Joo district.

  • PDF

소규모 오수처리를 위한 $A_{2}O$ SBR과 $A_{2}O$ SBBR에서 유입 유기물 농도변화에 따른 염양염류 제거 특성 비교 (A Comparison of Nutrients Removal Characteristics by the Variation of Organics in $A_{2}O$ SBR and $A_{2}O$ SBBR for the Small Sewerage System)

  • 박영식;정노성;김동석
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.451-461
    • /
    • 2006
  • Laboratory scale experiments were conducted to study the conversion of sludge from conventional activated sludge to nitrogen-phosphorus removal sludge using two types of sequencing batch reactor (SBR) systems, a conventional SBR and sequencing batch biofilm reactor (SBBR). The nitrogen and phosphorus removal characteristics were similar between SBR and SBBR and the removal efficiencies were very low when the influent TOC concentrations were low. The nitrogen and phosphorus removal efficiencies in SBR were 96% and 77.5%, respectively, which were higher than those in SBBR (88% and 42.5%) at the high influent TOC concentration. In SBBR, the simultaneous nitrification-denitrification was occurred because of the biofilm process. The variations of pH, DO concentration and ORP were changed as the variation of influent TOC concentration both in SBR and SBBR and their periodical characteristics were cleary shown at the high influent TOC concentration. Especially, the pH, DO concentration and ORP inflections, were cleary occurred in SBR compared with SBBR.

未完工干拓地의 定住生活 實態分析 (III) - 部落의 生活環境 - (Analysis on the Settlement Conditions in the Troubled Reclaimed Areas Under State Control (III) - Living Conditions in Rural communities -)

  • 최수명;황한철
    • 한국농공학회지
    • /
    • 제33권3호
    • /
    • pp.73-80
    • /
    • 1991
  • In Korea, small-scale reclaimed areas have been suffering from many problems because of the lack of comprehensive developing strategy although considerable investments have been inputed by the public sector since 1970's. For 3 reclaimed sites in Chonnam Province chosen as case study areas, the analysis, the third attempt of widely-spanned studies on areal conditions, concentrated on their living conditions. Its results were as follows : 1. Although rural residents have increased their concern on health and medical services, the public sector can only serve basic and emergent level of them, and therefore, the private sector, which is mostly placed in urban areas and costed much higher than public one, has the dominant share of those services. So, because those costs are a great expense to rural residents, their supplying system should be planned with special reference to lightening the economic burden of them. 2. By the development of locally fitted programs and innovative systems, the rural education should be qualitatively improved to deal successfully with its small scale. That will result in increasing the schooling rate to schools in rural communities, lightening the economic burden of rural residents on education services and finally activating them to contribute the betterment of rural education. 3. Servicing level of water supply, sewerage and garbage disposal in the reclaimed areas has been remaining at the lower order even in other rural areas. In the design of rural water supply, average daily consumption per capita should be changed according to the composition rate of fishing households and variety of the source of water supply. 4. Most of rural residents in the reclaimed areas want to establish the welfare facilites for the infant, youth, aged and public bath However in the long-term basis, the cooperative production and processing facilities should be considered for modernized efficient farming.

  • PDF

경기도의 2개 시.군 사례를 통한 농어촌지역 하수도 정비 추진 방안 (A Strategy for Improving the Sewerage Systems of Two Rural Areas in Gyeonggi Province)

  • 문철환;안지훈;장미정;이상협;조영무;김연제
    • 대한환경공학회지
    • /
    • 제32권6호
    • /
    • pp.563-580
    • /
    • 2010
  • 2009년 환경부는 '농어촌지역 하수도정비 종합계획'을 발표하면서 도시지역과 농촌지역의 하수도 서비스 격차를 줄이고 농어촌지역의 생활환경을 개선하기 위하여 2015년까지 약 4조 7천억 원의 예산을 투입하여 농어촌지역의 하수도 보급률을 75%까지 향상하겠다고 밝혔다. 하지만 이번 종합계획은 소규모하수도의 문제점을 정확히 파악하지 못하고 있어 하수도 보급률 증가에 따른 수질개선 효과는 기대하기 어려울 것이다. 따라서 본 연구에서는 경기도의 2개 지역 마을하수도 정비 사례를 중심으로 마을하수도의 문제점과 해결방안에 대해서 알아보고, 종합계획을 추진하는데 고려되어야 할 사항들에 대해서 논의하고자 한다. 현장조사를 통하여 하수의 불균등 유입, 저유량, 저부하 등의 문제가 공통적으로 발생하고 있는 것을 파악하였다. 유입되는 부하량에 맞게 처리시설의 운전 방법을 개선해야 하지만 대부분의 시설들이 설계시 제시된 운전인자로 운전되고 있어 처리효율이 저하되는 것으로 조사되었다. 정밀진단에서는 문제점에 대한 해결방안으로 유량균등화, 포기/ 비포기 비율 조절 등을 검토하여 현장에 적용하였으며, 그 결과 유기물 및 탈질산화 반응에 의한 T-N의 처리효율 개선되는 것을 확인할 수 있었다.