• 제목/요약/키워드: Small hydro

검색결과 243건 처리시간 0.029초

회전속도 변화에 따른 유도발전기의 특성 해석 (Characteristics Analysis of Induction Generator with a Change in Rotor Speed)

  • 김종겸;박영진;김일중;김영국
    • 전기학회논문지
    • /
    • 제60권12호
    • /
    • pp.2225-2229
    • /
    • 2011
  • Squirrel cage induction motor is the main driving system of industrial field and familiar with its use in a large variety of applications. However, many engineer are unfamiliar with the induction generator, even though no difference exists between both machines except for the mode of operation. But an induction generator is commonly used for micro & small hydro power applications due to its simplicity, reliability, low cost and robustness. Input and output of induction motor has turned against at the induction generator operation. Rotation speed of induction generator is small faster than induction motor. As output of induction machines increases with the increasement of speed, so loss is same. Actually, generator efficiency is lower than motor at this condition. If induction generator is connected with mechanical load, total efficiency is decreased. In this paper, we analyzed that input, output, torque and efficiency is different from each other above and below synchronous speed.

리액터 기동 유도발전기의 동작 특성 해석 (Operating Characteristic Analysis of the Induction Generator by the Reactor Starting)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제63권3호
    • /
    • pp.138-142
    • /
    • 2014
  • In general, the voltage stability of induction generator is lower than synchronous generator. However, induction generator has many advantages rather than a synchronous generator in terms of price and maintenance. So Induction generator is used little by little in small hydroelectric power station rather than 1000kW recently. Squirrel cage induction generator generates a high inrush current at the grid-connection. This high inrush current causes a voltage drop on the grid. In order to increase the penetration of the induction generator, it is necessary to present a method of reducing inrush current. In this study, we suggested that it is possible to present a reactor startup method, by applying the parameter to reduce the voltage drop.

농형 유도 발전기의 소프트 기동 특성 해석 (Soft Start-up Characteristics Analysis of Squirrel Cage Induction Generator)

  • 김종겸;박영진
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.103-107
    • /
    • 2016
  • In general, the voltage stability of induction generator is lower than synchronous generator. Induction generator has a number of advantages over the synchronous generator on the side of price and maintenance. So Induction generator has been applied to the small hydroelectric power of low output. Induction generator usually generates a high current during grid connection. The high current that occurs during grid connection can cause a voltage drop in the system. In order to increase the supply of the induction generator, it is necessary to propose a method of reducing high current. This paper proposes some method of the soft start to reduce voltage drop caused by the large starting current. soft-start method has high voltage drop effect than direct start method, control of firing angle can be increased the voltage drop effect.

소용량 EHD 발전에 관한 실험적 연구 (An Experimental Study on the Small Capacity EHD Power Generation)

  • 전춘생;이재복;임응춘
    • 태양에너지
    • /
    • 제9권2호
    • /
    • pp.58-68
    • /
    • 1989
  • This paper describes an experimental study that was performed to determine the limiting factors on the power output in the closed cycle Electro-Hydro-Dynamic generator of small capacity. A corona discharge for producing unipolar charged particles used as the charging method. The experiment demonstrated that the corona method of charging was an efficient and effective means of producing unipolar charged particles. Four factors having an effect on the power output characteristics of EHD generator are discussed and examined experimentally, using methyl alcohol and kerosene as working fluides; a. The conversion length between attractor and collector. b. The corona current of Emitter. c. The flow velocity of working fluids. d. Load resistance. This results are as follows; 1) There in a critical value in conversion length for its maximum power output. 2) Power output increases almost linearly with corona current and flow velocity. 3) There is the critical value of load resistance producing a maximum power output. 4) Kerosene is known better working fluid than Methyl alcohol in this EHD generator.

  • PDF

분포형 유역모델을 이용한 유사 운반과정의 시·공간적 변동 해석 (Estimating Temporal and Spatial Variation of Sediment Transport Processes using a Distributed Catchment Model)

  • 구본경;조재현
    • 한국물환경학회지
    • /
    • 제23권6호
    • /
    • pp.872-880
    • /
    • 2007
  • For effective management of sediment-related diffuse pollution, it is of utmost importance to estimate spatial variation of sediment transport processes within a catchment. A mathematical model can play a critical role in estimating sediment transport processes at the catchment scale provided that the model structure is appropriate for representing major sediment transport processes of the catchment of interest. This paper introduces a distributed catchment model River Basin Water Quality Simulator (RBWQS) and presents some results of its application to a small rural catchment in Korea. The model has been calibrated and validated for a wet period using hourly hydrographs and sediment concentrations observed at the catchment outlet. Based on the model simulation results, the spatial variation of sediment transport processes across the catchment and the effects of paddy fields and small reservoirs on hydrology and sediment transport have been analyzed at the catchment scale.

리액터 탭 설정값에 따른 유도발전기의 돌입전류와 전압강하 분석 (Analysis for the Inrush Current and Voltage Drop of Induction Generator by the Reactor Tap Change)

  • 김종겸
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1202-1206
    • /
    • 2015
  • The induction generator has many advantages compared to the synchronous generator in terms of cost and maintenance. So squirrel cage induction generator has been recently supplied in small hydroelectric power station. Squirrel cage induction generator generates a high inrush current at the grid-connection. This high inrush current causes a voltage drop on the grid. In order to increase the supply of the induction generator, it is very important to find the method of reducing inrush current and voltage drop.

카프란수차의 성능특성 (Performance Characteristics of Kaplan Turbine)

  • 이철형;주영철;박완순
    • 한국태양에너지학회 논문집
    • /
    • 제21권1호
    • /
    • pp.27-31
    • /
    • 2001
  • The Kaplan turbine model has been tested and analized. The blade angle and the guide vane opening of the turbine model were designed to be varied according to the best combination of guide vane and runner blade opening. When the changes in head and output were comparatively large, the efficiency drop were small, so the efficiency characteristics and stability of the entire operating condition were maintained in good condition. These results showed that the developed model in this study will be suitable for small hydro power stations with large changes in head and load.

  • PDF

Cosmological Information from the Small-scale Redshift Space Distortions

  • Tonegawa, Motonari;Park, Changbom;Zheng, Yi;Kim, Juhan;Park, Hyunbae;Hong, Sungwook
    • 천문학회보
    • /
    • 제44권2호
    • /
    • pp.52.3-52.3
    • /
    • 2019
  • We present our first attempt at understanding the dual impact of the large-scale density and velocity environment on the formation of very first astrophysical objects in the Universe. Following the recently developed quasi-linear perturbation theory on this effect, we introduce the publicly available initial condition generator of ours, BCCOMICS (Baryon Cold dark matter COsMological Inital Condition generator for Small scales), which provides so far the most self-consistent treatment of this physics beyond the usual linear perturbation theory. From a suite of uniform-grid simulations of N-body+hydro+BCCOMICS, we find that the formation of first astrophysical objects is strongly affected by both the density and velocity environment. Overdensity and streming-velocity (of baryon against cold dark matter) are found to give positive and negative impact on the formation of astrophysical objects, which we quantify in terms of various physical variables.

  • PDF

초소수력 발전 잠재량의 가시화를 위한 앱 개발 (Development of App. for Visualization of Micro Hydro Power Potential)

  • 김동현;양창욱;이승오
    • 한국콘텐츠학회논문지
    • /
    • 제17권4호
    • /
    • pp.1-11
    • /
    • 2017
  • 신재생에너지에 대한 관심이 증가하고 있지만 부정적인 여론으로 인해 초소수력 발전소 개발이 부진한 실정이다. 그러나 다른 신재생에너지에 비해 에너지 변환효율이 높고 이산화탄소를 배출하지 않아 대체에너지로써 개발 및 확대에 대한 관심이 필요하다. 이에 본 연구는 이클립스(Eclipse)를 이용하여 초소수력 발전량을 가시화하는 지도를 담는 애플리케이션을 개발하였다. 이를 통해 먼저 대상지점을 선택하고 미 공병단에서 제공하는 HEC-HMS으로 산출한 확률 설계유량으로 발전용량을 산정한 후 경제성 분석을 수행할 수 있다. 시범지역으로 강수량이 풍부한 강원도 영월군을 선정한 후, 국가수자원관리종합정보에서 제공하는 기초자료를 이용하여 초소수력 발전 잠재량 분석을 수행하였다. 본 연구 결과로 대상지점의 예상발전량, 연간전기생산량, 경제성분석 등을 단시간에 평가할 수 있고, 전국을 대상으로 잠재되어 있는 초소수력 발전 가능지역을 선별하는데 활용될 것으로 기대된다. 또한 간편하게 발전 가능지역을 선별할 수 있기 때문에 초기 투자비용을 줄일 수 있을 것으로 판단된다.

지점 강수량과 내삽기법을 이용한 면적평균 강수량 산정의 오차 분석 (Error analysis of areal mean precipitation estimation using ground gauge precipitation and interpolation method)

  • 황석환;강나래;윤정수
    • 한국수자원학회논문집
    • /
    • 제55권12호
    • /
    • pp.1053-1064
    • /
    • 2022
  • 현행 면적평균 강수량 산정 방법인 티센 방법은 정확한 유역평균 강수량 산정에 있어 심각한 구조적 한계가 존재한다. 강수량계의 관측 정확도 외에, 강수량계 배치와 호우의 이동 방향에 따라서도 면적평균 강수량 산정에 오차가 발생할 수 있다. 유역이 작고 관측소 밀도가 희박한 경우 시뮬레이션 및 관측 사상 모두에서 티센 방법은 첨두 전후로 10분 사이에 유역평균 강수량이 계속 급격히 증감이 반복되는 특이한 경향 보였다. 그리고 티센 유역평균 강수량은 첨두 시점이 강우레이더와 다르게 나타났다. 유역이 작지만 관측소 밀도 비교적 높은 경우에는 전반적으로 티센 방법에 의해 톱니모양의 과대 첨두치의 경향은 나타나지 않았고 시간에 따른 변동이 유사하게 나타났다. 그러나 강우레이더 관측치와 지상 강수량계 관측치 유역평균 강수량 사이에 약 10분 정도의 연속적인 시차가 발생하였다. 강우레이더 유역평균 강수량의 지상보정 효과를 검토한 결과, 보정 후 면적평균 강수량이 보정 전 면적평균 강수량에 비해 오히려 상관이 낮게 나타나, 현행 강우레이더 지상보정 알고리즘 보정 효과가 높지 않은 것을 알 수 있었다.