• Title/Summary/Keyword: Small form Factor

Search Result 283, Processing Time 0.031 seconds

Experimental Study on Various Ramp Profiles during Unloading Process (초소형 HDD의 언로딩 과정에서 램프 형상에 대한 실험 연구)

  • Lee, Young-Hyun;Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.314-317
    • /
    • 2005
  • There are many benefits such as increased areal density, reduced power consumption, applied smaller size and improved shock resistance in Load/Unload(L/UL) mechanism. It has been the key technology of developing small form factor hard disk drive used in portable digital devices. The main objectives of L/UL are no slider-disk contact and faster L/UL process. For realizing those, we must consider many design parameters in L/UL systems. In this paper, we focus on the effects of ramp profile. We can investigate dynamic characteristics of suspension tap and slider on ramp during unloading process experimentally. In special, we examine the effects of vortical velocities, ramp slopes and disk vibrations. As the result of these experiments, we propose design criteria of advanced ramp profile for good unloading performance.

  • PDF

Improved Velocity Control in Ramp Load/Unload HDD (램프 로드/언로드 HDD에서의 향상된 속도 제어)

  • Song, Yeon-Chul;Park, Sung-Won;Jeong, Jun;Park, Tae-Wook;Yang, Hyun-Seok;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.586-591
    • /
    • 2004
  • A load/unload mechanism is applied to most small form factor hard disk drives. Loading velocity is ones of the most important factors to ensure the reliability of the load/unload operations. Especially, the lower the flying height of the head becomes, the more important the accuracy of the loading velocity control becomes. Because there is no sensor during the load/unload operations, BEMF voltage is used to sense the head velocity. To measure BEMF voltage, a simple circuit is added to the load/unload HDD control system. Overall acceptable results are obtained by using the simple PI controller but the errors from the target velocity occur when the head moves along the ramp and then reaches the disk. Feedforward profile and disturbance observer are used to remove those errors effectively.

  • PDF

Prediction of Surface Roughness in Hole Machining Using an Endmill (엔드밀을 활용한 홀 가공 시 표면거칠기 예측에 관한 연구)

  • Chun, Se-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.42-47
    • /
    • 2019
  • Helical machining is an efficient method for machining holes using an endmill. In this study, a surface roughness prediction model was constructed for improving the productivity of hole machining. Experiments were conducted to form holes by the helical machining of AL6061-T4 aluminum sheets and correlation analysis was performed to examine the relationships between the variables based on the measured results. Meanwhile, a regression analysis technique was used to construct and evaluate the prediction model. Through these analyses, the parameter which has the greatest influence on the surface roughness when the hole is formed by the helical machining is the feed, followed by the number of revolutions of the endmill. Moreover, for the axial feed of the endmill, it was concluded that the influence of the surface roughness is small compared to the other two parameters but it is a factor worth considering to improve the accuracy when constructing the predictive model.

A 2.4 GHz Low-Noise Coupled Ring Oscillator with Quadrature Output for Sensor Networks (센서 네트워크를 위한 2.4 GHz 저잡음 커플드 링 발진기)

  • Shim, Jae Hoon
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.121-126
    • /
    • 2019
  • The voltage-controlled oscillator is one of the fundamental building blocks that determine the signal quality and power consumption in RF transceivers for wireless sensor networks. Ring oscillators are attractive owing to their small form factor and multi-phase capability despite the relatively poor phase noise performance in comparison with LC oscillators. The phase noise of a ring oscillator can be improved by using a coupled structure that works at a lower frequency. This paper introduces a 2.4 GHz low-noise ring oscillator that consists of two 3-stage coupled ring oscillators. Each sub-oscillator operates at 800 MHz, and the multi-phase signals are combined to generate a 2.4 GHz quadrature output. The voltage-controlled ring oscillator designed in a 65-nm standard CMOS technology has a tuning range of 800 MHz and exhibits the phase noise of -104 dBc/Hz at 1 MHz offset. The power consumption is 13.3 mW from a 1.2 V supply voltage.

Miniaturized Sensor Interface Circuit for Respiration Detection System (호흡 검출 시스템을 위한 초소형 센서 인터페이스 회로)

  • Jo, Sung-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.8
    • /
    • pp.1130-1133
    • /
    • 2021
  • In this paper, a miniaturized sensor interface circuit for the respiration detection system is proposed. Respiratory diagnosis is one of the main ways to predict various diseases. The proposed system consists of respiration detection sensor, temperature sensor, and interface circuits. Electrochemical type gas sensor using solid electrolytes is adopted for respiration detection. Proposed system performs sensing, amplification, analog-to-digital conversion, digital signal processing, and i2c communication. And also proposed system has a small form factor and low-cost characteristics through optimization and miniaturization of the circuit structure. Moreover, technique for sensor degradation compensation is introduced to obtain high accuracy. The size of proposed system is about 1.36 cm2.

A Study on Low Power Consuming FEC Design for XFP Transceiver System Transmission (XFP 트랜시버 데이터 전송을 위한 저전력 FEC 설계에 관한 연구)

  • Lee, Min Soo;Lee, Kyeong Won;Yoon, Byoung Don;Min, Hyoung Bok
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.11a
    • /
    • pp.973-974
    • /
    • 2010
  • 본 논문에서는 XFP(10 Gb/s Small Form Factor Pluggable) 트랜시버 모듈의 정확한 데이터 전송을 위해 저전력 FEC를 설계하였다. 현재 많이 사용되며 버스트 에러에 강한 Reed-solomon코드를 구현하고 코드의 분산 연산을 통해 저전력 RS코드를 구현하였다. 본 논문에서 제안한 코드는 기존의 RS코드 대비 20% 면적이 감소하는 것을 확인할 수 있었으며, 또한 전력소모가 10% 감소되는 것을 확인 할 수 있었다.

Advancements in Capacitive Touch System and Stylus Technologies

  • Ha-Min Lee;Seung-Hoon Ko
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.5
    • /
    • pp.465-475
    • /
    • 2024
  • Due to changes in the form factor of display panels and touch screen panels in various devices, capacitive touch systems have evolved to address various issues such as low power consumption, noise immunity, and small chip size. Furthermore, some devices have applications that use a stylus. Since the stylus operates similarly to a finger touch, it encounters similar issues. Recent research trends focus on addressing key issues such as noise, which is primarily caused by the self-capacitor formed between the display cathode and the touch screen panel. In this paper, Various research papers discussing methods to eliminate external noise will be reviewed. These advancements enhance noise immunity in touch systems, making it easier to use thinner and more flexible panels. These progress make touch technology more versatile and reliable in various applications.

Breakthroughs in the Systemic Treatment of HER2-Positive Advanced/Metastatic Gastric Cancer: From Singlet Chemotherapy to Triple Combination

  • Sun Young Rha;Hyun Cheol Chung
    • Journal of Gastric Cancer
    • /
    • v.23 no.1
    • /
    • pp.224-249
    • /
    • 2023
  • Gastric cancer is heterogeneous in morphology, biology, genomics, and treatment response. Alterations in human epidermal growth factor receptor 2 (HER2) overexpression, microsatellite instability (MSI) status, programmed death-ligand 1 (PD-L1) levels, and fibroblast growth factor receptor 2 (FGFR2) can be used as biomarkers. Since the combination of fluoropyrimidine/platinum plus trastuzumab that was investigated in the ToGA trial was approved as a standard of care in HER2-positive patients in 2010, no other agents showed efficacy in the first- (HELOISE, LOGiC, JACOB trials) and second- (TyTAN, GATSBY, T-ACT trials) line treatments. Despite the success in treating breast cancer, various anti-HER2 agents, including a monoclonal antibody (pertuzumab), an antibody-drug conjugate (ADC; trastuzumab emtansine [T-DM1]), and a small molecule (lapatinib) failed to translate into clinical benefits until the KEYNOTE-811 (first-line) and DESTINY-Gastri01 (≥second-line) trials were conducted. The incorporation of HER2-directed treatment with immune checkpoint inhibitors in the form of a monoclonal antibody or ADC is now approved as a standard treatment. Despite the promising results of new agents (engineered monoclonal antibodies, bi-specific antibodies, fusion proteins, and small molecules) in the early phase of development, the management of HER2-positive gastric cancer requires further optimization to achieve precision medicine with a chemotherapeutic backbone. Treatment resistance is a complex process that can be overcome using a combination of chemotherapy, targeted agents, and immune checkpoint inhibitors, including novel agents. HER2 status must be reassessed in patients undergoing anti-HER2 treatment with disease progression after the first-line treatment. As a general guideline, patients who need systemic treatment should receive chemotherapy plus targeted agents, anti-angiogenic agents, immune checkpoint inhibitors, or their combinations.

Classification of Upper Torso Somatotype for Development of Senior Men's Dressform (시니어 남성의 기성복 피팅용 드레스폼 개발을 위한 상반신 체형분류)

  • Do, Wolhee;Choi, Eunhee
    • Fashion & Textile Research Journal
    • /
    • v.19 no.6
    • /
    • pp.804-812
    • /
    • 2017
  • This study builds a database that can be reflected in the production of dress form for fitting by typifying the upper body shape of a senior male. This study analyzed the 3D shape data of 405 persons of the 5th Size Korea. The age range is from 50s 210 persons and 60s 205 persons. Analysis items to identify upper body shape of senior males consisted of 51 items. 3D shape data were also measured using a Geomagic Design ${\times}$ program for the analysis of the upper body of the senior male required for the dress form of this study. The reference point was based on the Size Korea 2010 3D measurement standard and created points (Back-protrusion) on shape data. As a result of the senior men type, the senior men's body type was classified into four types:1. Overall, the upper body is a large body type and the most undistorted overall body type 2. Width / Thickness Flatness is the largest and vertical length factor is the smallest abdominal obesity type 3. Severe flexion of the back part type 4. The upper body is small and the scapular bending is severe. The elderly body type showed a high distribution ratio in the type with severe flexion. The development of a dress form that reflects the cause of the finery issue can improve the fit of ready-to-wear.

Lower Body Type Classification by Buttocks Shapes of Korean Women in Their 20's (국내 20대 여성의 엉덩이 형태에 따른 하반신 체형 분류)

  • Choi, Se-Lin;Do, Wol-Hee
    • Fashion & Textile Research Journal
    • /
    • v.18 no.3
    • /
    • pp.327-337
    • /
    • 2016
  • The purpose of this study is for size suitability and fitness improvement for Korean 20's women. This study has classified hip types of 20's women by the 6th Korean Anthropometric Survey(Size Korean), then compared their lower body-type by hip types each other. The results are as follows. Factor analysis in sorting hip types can be explained 77.72% by nine factors. And cluster analysis can be divided into three types. Type 1 is referred to as a general type which has the largest size in the 'Hip circumference', but the buttocks's horizontal sizes are in the middle size besides the hip line. Type 2 is referred to as a protruding type in upper buttocks which is large in protruding volume of upper buttocks, but the buttock's horizontal sizes are small including 'Hip circumference', and buttock's horizontal section form close to circle. Type 3 is referred to as a type which is contrary to Type 2. Type 3 is small in protruding volume of upper buttocks, but large in lower buttocks, and the protrusions in whole buttocks are small, so the side view of Type 3 made gentle fit shape. By these results, the study could classify lower body of 20's women, and it can be basic data for new sizing systems and pattern development of bottoms.