• 제목/요약/키워드: Small field dosimetry

검색결과 43건 처리시간 0.038초

확장된 쐐기조사야에 의한 조직산란계수의 변화 (The Variation of PSF Induced Enlarged Wedged Fields)

  • 이정우;조화섭;박성렬
    • 대한방사선치료학회지
    • /
    • 제10권1호
    • /
    • pp.97-101
    • /
    • 1998
  • In recent days, although many kinds of beam modifiers are developing and using for clinical purposes in accordance with progressing medical engineering, physical wedges are preferred to use as a beam modifier by a lot of institutions until now because of cost, complexities of dosimetry and mechanical uncertainties. According to progressing technology, available field size of wedge is more enlarger than that of old model LINAC. Because field size dependence of wedged fields increases in new model LINAC, we was trying to know that how much different PSFs are in enlarged wedged fields compared with open fields. In small or middle size of fields($4{\times}4{\sim}15{\times}15cm$), there are only a few percents of PSF variation between open and wedged fields. But there are $2{\sim}8\%\;variations\;in\;relatively\;large\;fields(20{\times}20{\sim}30{\times}40cm)$.

  • PDF

다엽제한기 소조사면의 6 MV 광자선 출력선량계수 (The Output Factor of Small Field in Multileaf Collimator of 6 MV Photon Beams)

  • 이호준;최태진;오영기;전경수;이용희;김진희;김옥배;오세안;김성규;예지원
    • 한국의학물리학회지:의학물리
    • /
    • 제25권1호
    • /
    • pp.15-22
    • /
    • 2014
  • 종양부위의 입체적이고 선택적인 치료가 가능해 임상표적부피(clinical target vlume, CTV)에 높은 선량으로 집중조사하고 부작용을 현저히 줄이는 세기조절방사선치료는 치료예후를 향상시키고 있다. 방사선세기조절 치료는 MLC의 개방면적과 개방시간으로 조사면내 플루언스를 조정하므로 소형조사면의 선량이 누적되어 원하는 선량이 조사하게 된다. 따라서 소형조사면과 계층형 조사면의 출력선량계수의 정확성은 곧 Portal MU 결정에 정확성을 더할 수 있고, 종양에 조사되는 선량의 정확성을 향상할 수 있으므로, 이 연구는 Clinac Ex (Varian) $3{\times}3cm^2$에서 $0.5{\times}0.5cm^2$까지 조사면을 선정하였고 방사선은 6 MVX선의 소형조사면의 출력선량계수를 평가하였다. 조사면은 다엽제한기를 $40{\times}40cm^2$로 개방하고 Collimator jaw를 이용한 것과 Collimator를 $10{\times}10cm^2$로 고정하고 다엽제한기에 의한 조사면으로 구분하여 출력선량계수가 결정되었다. 검출기는 유효체적이 $0.01cm^3$이고 내경 2 mm인 CC01 (Scanditronix-Wellope)이온전리함과 SFD 다이오드 검출기(0.6 mmØ, $500{\mu}m$ 두께, Scanditronix-Wellope)와 다이아몬드 검출기(T60003, PTW)와 X-Omat film을 사용하였다. 결과는 다엽제한기 조사면의 출력선량계수는 $3{\times}3cm^2$에서 $0.899{\pm}0.0106$, $2{\times}2cm^2$에서 $0.855{\pm}0.0106$, $1{\times}1cm^2$에서 $0.764{\pm}0.0082$, $0.5{\times}0.5cm^2$에서 $0.602{\pm}0.0399$를 얻었다. Jaw를 $10{\times}10cm^2$로 고정하고 다엽제한기의 조사면의 출력계수는 MLC를 $40{\times}40cm^2$에 jaw에 의한 소형조사면의 것보다 최대 3.8% 높게 나타남을 확인하였다. 따라서 세기조절방사선치료 TPS에는 collimator jaw 보다 다엽제한기 조사면 크기의 출력선량계수가 설정되는 것이 중요함을 의미한다.

뇌정위적 방사전수술을 위한 소조사면 측정 (Small Field Dosimetry for Stereotacitc Radiosurgery)

  • 최동락;안용찬;이정일;허승재
    • 한국의학물리학회지:의학물리
    • /
    • 제6권1호
    • /
    • pp.59-64
    • /
    • 1995
  • 본 연구의 목적은 뇌정위적 방사선수술을 시행하기 위한 치료계획 수립에 필요한 빔 측정자료를 구하는 것이다. 다이오우드, 필름, 미소전리함 (0.003cc), TL, 그리고 물팬톰용 전리함 (0.125 cc)을 이용하여 빔 자료를 측정하였다. 측정된 결과는 상호비교하였으며 OAR 은 필름, 산란인자와 TMR은 다이오우드로 측정된 자료를 치료계획용 컴퓨터의 기본자료로 사용하였다.

  • PDF

증기발생기 수실의 방사선장 특성 및 작업자 유효선량의 평가 (Characterization of Radiation Field in the Steam Generator Water Chambers and Effective Doses to the Workers)

  • 이춘식;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제24권4호
    • /
    • pp.215-223
    • /
    • 1999
  • PWR 원전 증기발생기 수실의 방사선장 특성과 그곳에서 작업하는 종사자의 유효선량을 몬테칼로 시뮬레이션으로 평가하였다. 선원항으로는 고리1호기 증기발생기 방사화물 분석결과가 사용되었으며 유효선량 평가에는 MCNP4A코드와 MIRD형 성별 수학적 인형 모의피폭체가 사용되었다. 수실 내부 방사선장은 U튜브 영역에서 내려오는 방사선이 지배적이었으며 극각에 대해 근사적으로 코사인 분포를 나타내었다 유효선량률은 표준성인과 체격이 작은 성인(이 목적으로 15세 모의피폭체가 사용되었다.)의 경우 각각 36.22$mSvh^{-1}$와 37.06$mSvh^{-1}$로서 체격의 영향은 경미했다. 한편, 모의피폭체의 머리, 가슴 및 하복부에 해당하는 위치에서 평가된 조사선량률과 에너지스펙트럼에 대해 ICRU47에서 주어진 주위선량당량 환산계수를 이용해 평가한 등가선량률은 각각 119, 71, 및 58 $mSvh^{-1}$로 나타났다. 따라서 개인선량계 판독에서 얻는 심부선량 또는 유효선량은 앞서 계산한 유효선량률의 2배 정도가 될 것으로 보인다. 이 사실은 일반적인 개인선량계의 경사입사 방사선에 대한 과대/과소 평가 특성과 함께 비정규, 고선량률 방사선장에 종사하는 작업자의 선량계측 계획 및 결과의 해석에 매우 신중해야 함을 알려준다.

  • PDF

선형가속기에서 상위조리개와 하위조리개의 교환에 의한 선량 변화의 고찰 (The study on dose variation due to exchange of Upper and Lower jaw in the linear accelerator)

  • 임충근;김회남;송기원
    • 대한방사선치료학회지
    • /
    • 제11권1호
    • /
    • pp.6-10
    • /
    • 1999
  • The field size can be beam output, therefore MonitorUnit can be varied due to field size dependence The purpose of this study is to evaluate and compare the dose variation according to exchange of collimator The measurements were perfomed with Wellhofer dosimetry system(water phantom. ion chamber. electrometer. system controller. build up cap. etc)and two types of linear accerlerator (Mevatron KD, MevatronMX) Scatter can be affected to field size dependence and scatter correction is separated into collimator and phantom components, scatter components can affect by exchanging of collimator Measurements of collimator scatter factor(Sc) was done in air with build up cap. 1)Square field (5cm2 to 40cm2) was measured 2)and then keeping the upper jaw constant at loom and varing lower jaw from 5cm to 40cm, 3)keeping the lower jaw constant at 10cm and varing upper jaw from 5cm to 40cm Measurements of total scatter factor(Scp) was done in water at Dmax as the procedure of collimator scatter factor measurements in water Dmax The total scatter factors were obtained to the following equation(Sp=Scp/Sc) The measured data is normalized to the data of reference field size($10{\times}10$), rectangular field is inverted to equivalent field to compare three field size data As the collimator setting is varied, the output was changed In conclusion, the error was obtained small but it must be eliminated if we intend to reach the common stated goal of $5\%$ overall uncertainty in dose determination

  • PDF

소조사면에서의 불균질 물질 보정 계산의 평가 (Estimation of Inhomogeneity Correction Factor in Small Field Dosimetry)

  • 신헌주;강영남;장지선;서재혁;정지영;최병옥;최일봉;이동준;권수일
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.260-268
    • /
    • 2009
  • 정위방사선수술시 소조사면에서의 불균질 물질에 따른 보정 계수를 구하고, 치료계획 시스템의 선량계산 값과 실제 조사된 선량값을 비교, 분석하여 불균질 물질 보정에 의한 선량계산의 정확성을 평가한다. 본 실험을 위하여 12가지 종류의 불균질 물질과 필름 및 이온 전리함을 장착할 수 있는 팬톰(Inhomogeneity Correction Phantom, ICP)을 제작하였다. 각각의 불균질 물질의 전자밀도값을 치료계획 시스템에 입력하여 치료계획을 수립하고, 선량분포와 임의의 위치에서의 절대선량 측정을 위해 EBT 필름과 0.125 cc 이온전리함을 이용하였으며 불균질 물질 보정 계수 적용과 비적용에 따른 치료계획의 차이와 필름에 조사된 선량값 및 이온 전리함의 절대 선량값의 차이를 분석하였다. 불균질 물질 보정 계수의 적용과 비적용시 각각의 치료계획과 측정값을 비교, 분석한 결과 평균 1.63%, 10.05%이었고, 각 경우의 측정값을 비교한 결과 평균 10.09%이었다. 또한, 임의의 위치에서의 절대선량값을 비교한 결과 불균질 물질 보정 계수의 비적용시에는 평균 2.90%, 적용시에는 평균 0.43%의 차이를 보였다. 본 실험 결과 직경 1 cm의 목표점에 방사선을 조사하였을 때 불균질 물질 보정 계수 적용 전의 선량분포 및 임의의 위치에서의 절대 선량이 적용시보다 큰 차이를 나타냈으며, 본 실험에서 사용된 소조사면의 치료계획시스템은 불균질 물질 보정이 정확하게 수행되는 것을 확인하였다. 결론적으로 1% 이하의 정확도를 가지고 시행하는 소조사면에서의 정위방사선수술의 경우 불균질 물질에 대한 보정이 일반적인 조사면에서의 적용 보다 더 정확하게 수립이 되어야 한다.

  • PDF

마이크로필름과 탄소막 전극을 이용한 소형방사선측정기 개발에 관한 연구 (A Study of Small Radiation Dosimeter by Using Microfilm and Carbon Elecrtode)

  • 신교철;윤형근
    • 한국의학물리학회지:의학물리
    • /
    • 제15권2호
    • /
    • pp.59-62
    • /
    • 2004
  • 본 논문에서는 마이크로필름과 탄소막 전극을 이용하여 개발한 소형 방사선측정기의 특성을 평가하였다. 전극은 5 mm 직경의 고전압전극, 3.3 mm 직경의 수집전극, 그리고 넓이가 0.7 mm인 보호전극으로 구성되었으며, 이온수집 공동의 부피는 0.016 ㎤이었다. 6 MV X-선을 이용하여 제작된 측정기에 대한 전기적 특성을 조사하였는데, 누설전류는 0.1 pA, 재현 오차가 0.1% 이하, 선량률 효과는 1.5% 이하, 분극효과는 2.4% 이하로 나타났다. 개발된 측정기의 전기적 특성은 양호한 것으로 평가되며, 추후 깊이선량률, 빔측면도와 같은 선량분포에 대한 특성의 평가가 요구된다.

  • PDF

작은 블럭을 이용한 판톰 내에서의 판톰 산란 인자(Sp Factor)측정법 (Determination of the Phantom Scatter Factor ($S_P\;Factor$) using a small Block in the Phantom)

  • 이병용;홍석민;김재성;최은경;장혜숙;이명자;전하정
    • Radiation Oncology Journal
    • /
    • 제10권1호
    • /
    • pp.121-123
    • /
    • 1992
  • 판톰 산란 인자($S_{p}$) 측정을 위한 새로운 방법을 소개한다. 측정용 전리함을 가릴 수 있는 블럭을 이용하여 $S_{p}$인자를 구할 수 있음을 이론적으로 증명하였으며, 이의 검증을 위해 $^{60}Co$을 이용하여 실험하였다. 이론값과 실험값과의 차이는 1%를 넘지않았다. 이 새로운 방법을 이용하면 고에너지 광자선측정에서 문제로 대두되고 있는 공기중 측정이 필요 없으며, 작은 블럭 차폐물만을 이용하여 $S_{p}$인자를 구할 수 있음을 확인하였다.

  • PDF

6-MV선형가속기를 이용한 입체방사선수술의 선량측정 및 3차원적 치료계획 (Dosimetry and Three Dimensional Planning for Stereotactic Radiosurgery with SIEMENS 6-MV LINAC)

  • 최동락;조병철;서태석;정수미;최일봉;신경섭
    • Radiation Oncology Journal
    • /
    • 제11권1호
    • /
    • pp.175-181
    • /
    • 1993
  • 방사선수술을 시행하기 위해서는 종양의 위치결정, 흡수선량 계산, 그리고 치료를 위한 특수제작된 기구와 컴퓨터 프로그램이 요구된다. 본 연구의 목적은 선형가속기의 전반적인 기계적 정밀도를 확인하고 선형가속기를 이용한 방사선수술에 있어서의 선량계산 알고리즘을 개발하는 것이다. 치료기계의 정렬과 전반적인 치료체계의 성과에 대한 점검을 행하였고 백분율 심부선량, 중심축외 선량비, 그리고 출력인자와 같은 기본 계산자료를 측정하였다. 또한, 입체방사선수술을 위한 3차원적 치료계획 체계를 개발하였다. 선량분포를 계산하기 위하여 C-언어를 이용한 컴퓨터 프로그램을 작성하였고 하드웨어로는 IBM PS/2 (Intel 80386 SX, 24 MHz)를 사용하였다. 그 결과, 주 병원이 보유한 선형가속기의 겐트리와 테이블 회전에 따른 중심점에 대한 오차는 2 mm 이내로 방사선수술을 시행하기에 충분하였다. 팬톰실험에 따르면, 컴퓨터 단층촬영을 이용한 위치결정을 포함한 표적에의 빔의 일치도는 역시 2mm 이내였다. 끝으로, 본원에서 개발한 3차원적 치료계획의 정확도는 필름을 이용한 선량측정을 통하여 입증되었다.

  • PDF

선형가속기를 기반으로 한 뇌정위 방사선 수술 시 전용 콘과 정방형 소조사면의 선량 특성에 관한 고찰 (Evaluation of Dosimetric Characteristics of Small Field in Cone Versus Square Fields Based on Linear Accelerators(LINAC) for Stereotactic Radiosugery(SRS))

  • 윤준;이귀원;박병문
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권1호
    • /
    • pp.61-66
    • /
    • 2010
  • 선형가속기를 기반으로 하는 뇌정위적 방사선 수술에 있어 전용 콘과 동일한 정방형 조사면에서의 소조사면 선량특성에 관해 알아보고자 6 MV 광자선과 소조사면 전용 검출기를 이용해 측정하였다. 선원 표면간 거리는 100 cm로 하고, 전용 cone ${\Phi}1\;cm$, ${\Phi}2\;cm$, ${\Phi}3\;cm$과 정방형 조사면 $1{\times}1\;cm^2$, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$ 조사면 으로 1.5 cm, 5 cm, 10 cm, 20 cm, 30 cm 지점에서 심부선량을 측정하였고, 최대 선량점에서 각 조사면에서 출력선량을 측정하여 비교하였다. 반음영의 측정을 위한 선량측면도 측정은 ${\Phi}1\;cm$, ${\Phi}3\;cm$ 및 동일한 정방형 조사면에서 선원 표면간 거리 95 cm, 깊이 5 cm에서 SFD를 이용하여 측정하였다. 물리학적 조사면(90%) 내에서는 1 mm 간격으로, 반음영 영역(20~80%)에서는 0.5 mm 간격으로 측정하였다. 전용 콘 과 정방향 조사면의 PDD 변화는 기준조사면을 기준으로 5 cm 깊이에서 4.3~7.9% 낮게 나타났으며, 콘의 크기와 조사면 크기가 커질수록 PDD 변화는 적게 나타났다. 선질 비교를 위해 $PDD_{20,10}$를 비교한 결과 ${\Phi}1\;cm$ 콘과 $1{\times}1\;cm^2$을 제외한 다른 조사면에서는 1% 이내의 변화를 보였다. 출력선량은 콘을 이용한 방법에서 정방형 조사면에서 보다 3.1~4.6% 출력선량이 증가하였다. 반음영 영역은 ${\Phi}1\;cm$, ${\Phi}3\;cm$ 동일한 정방형 조사면에서 콘을 이용한 방법이 반음영 영역이 20% 감소하였다. 뇌정위적 방사선 수술은 소조사면을 이용해 1회 대선량을 조사하는 방법으로 조사면의 선량특성을 고려한 처방이 중요하게 된다. 본 실험을 통해 뇌정위적 방사선 수술에 있어 정방형 소조사면 보다 전용 콘을 이용한 방법이 유효하다고 사료되며, 향후 다양한 측정기를 이용한 소조사면의 선량특성에 관한 연구가 필요하다고 생각된다.