• Title/Summary/Keyword: Small bridge

Search Result 537, Processing Time 0.031 seconds

The Suitable Types and Measures of Wildlife Crossing Structures for Mammals of Korea (국내 포유동물에 적합한 생태통로의 유형과 규격)

  • Choi, Tae Young;Yang, Byeong Gug;Woo, Dong Geol
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.1
    • /
    • pp.209-218
    • /
    • 2012
  • In this study, suitable types and measures of Wildlife Crossing Structures (WCS) for mammals of Korea were analyzed to suggest basic information for design guidelines of WCS. In order to find the types and measures, we conducted field surveys on 79 WCS and literature reviews on 159 WCS. The results of our study were as follows; Small-medium sized carnivores usually use all measures of wildlife underpass, meanwhile large sized herbivores as water deer need lager measures than 0.7 Openness Index(OI). Furthermore, we found that wildlife overpasses were usually used at the measure of 6.8 m width by every mammal. Therefore, we concluded that the proper measures should be lager than 0.7 OI for underpass and 7 m width for overpass.

A Novel Circuit Configuration of UPS with Auxiliary Inverter and Its Specific Control Implementations

  • Hirachi, Katsuya;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.224-229
    • /
    • 2003
  • The rapid expansion of small computers over the last 10-odd years has brought about great changes in the circumstances affecting UPSs. There are strong demands that UPSs become much smaller and lighter, and more economical, which has resulted in the wide application of the circuit topology without transformer. A disadvantage of such UPS topology is that the DC link voltage is very high, which invites decreased reliability and increased cost of battery bank. Some circuit configurations were proposed to eliminate this disadvantage, but they still had problems. In this paper, a novel circuit configuration which eliminates these problems is proposed and evaluated by the experimental results of prototype UPS.

A 3-Bridge LLC Resonant Converter with Wide Input/Output Voltage Gain Characteristics (넓은 입·출력 전압이득 특성을 갖는 3 브리지 LLC 공진컨버터)

  • Yoo, Sang-Jae;Jang, Ki-Chan;Kim, Eun-Soo;Jeon, Yong-Seog;Kook, Yoon-Sang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.2
    • /
    • pp.142-151
    • /
    • 2020
  • This paper presents a DC/DC LLC resonant converter with wide input/output voltage gain characteristics and its control method for efficiency improvement. For a wide input/output voltage gain characteristics without designing small transformer magnetization inductance, the proposed converter changes the topology into three modes of operation according to the main switch switching pattern. In each operating mode, variable LINK voltage modulation and frequency modulation were performed to control output voltage and improve operating efficiency. A prototype of a 5-kW DC/DC LLC resonant converter was built and tested to verify the validity and applicability of the proposed converter.

A Study on The Development of small System using the High-Frequency Resonant Inverter Of 1.5[kW] class (1.5[kW]급 고주파 공진형 인버터를 이용한 유도가열 가정용 시스템에 관한 연구)

  • Yoo, Jae-Hoon;Shin, Dae-Cheul;Kwon, Hyuk-Min;Park, Hee-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1527-1529
    • /
    • 2005
  • 고주파 유도가열은 무공해 에너지 절약을 기본으로 하는 전기가열의 한 방법으로 환경친화 및 에너지 절감의 요구에 부응하기 위한 것으로 고주파 공진형 인버터 기술과 충진 발열체의 열 교환 기술을 적용한 새로운 시스템이다. 본 논문에서는 1.5[kW]급 Half-Bridge 고주파 공진형 인버터를 이용한 유도가열 시스템의 동작해석, 특성분석 및 본 시스템을 이용한 가정용 시스템의 응용과 이동유체의 순시가열 시스템의 성능평가에 대하여 논한다.

  • PDF

High Resolution Patterning Method by Using Water-mediated Nanotransfer Molding

  • Hwang, Jae-Kwon;Dang, Jeong-Mi;Sung, Myung-Mo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.83-83
    • /
    • 2010
  • We report a new direct printing method, called liquid-mediated nanotransfer molding (LB-nTM), that uses a polar liquid-mediated transfer process. LB-nTM is based on the direct transfer of various materials from a stamp to a substrate via a liquid- bridge between the stamp and the substrate. This procedure can be adopted in automated printing machines that generate various material patterns with a wide range of feature sizes (as small as 60 nm) on diverse substrates. To demonstrate its usefulness, the LB-nTM method was applied to prepare ZnO-nanowire and TIPS-pentacene transistors.

  • PDF

Vibration Control of Flexible Structures using ER Fluid Dampers (ER댐퍼를 이용한 유연 구조물의 진동제어)

  • 이재홍;최승복
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.243-247
    • /
    • 1996
  • This paper presents a vibration control of a flexible structure using a controllable ER fluid damper. A clamped-clamped flexible structure system supported by two short columns mimicking a small-sized bridge system is considered. An ER fluid damper which is operated in shear mode is designed and attached to the middle of the flexible structure. The governing equation of motion and associated boundary conditions are derived from Hamilton's principle. A sliding mode control is formulated in order to actively suppress the vibration of the structure due to external excitations. Experimental control results are presented in the frequency domain.

  • PDF

A study on the improvement of efficiency in the light railway vehicle system using IPT (유도 급전을 이용한 경전철 시스템의 효율 개선에 대한 연구)

  • Choi, Seung-Cheol;Lee, Byung-Song;Mok, Hyung_Soo
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.62-63
    • /
    • 2010
  • This paper presents a potential for application of Inductive Power Transfer(IPT) to the light railway vehicle system. IPT system allows for a vehicle fitted with existing or new generation batteries to park over a small charging unit and commence charging immediately. Regular charging will allow for smaller batteries to be used in vehicles. In this paper, IPT system uses a full-bridge LLC resonant converter and is possible for the regenerative braking which is an energy recovery mechanism.

  • PDF

Eringen's nonlocal model sandwich with Kelvin's theory for vibration of DWCNT

  • Hussain, Muzamal;Naeem, Muhammad N.;Asghar, Sehar;Tounsi, Abdelouahed
    • Computers and Concrete
    • /
    • v.25 no.4
    • /
    • pp.343-354
    • /
    • 2020
  • In this paper, vibration characteristics of chiral double-walled carbon nanotubes entrenched on Kelvin's model. The Eringen's nonlocal elastic equations are being combined with Kelvin's theory to observe small scale response. A nonlocal model has been formulated to explore the frequency spectrum of chiral double-walled CNTs along with diversity of indices and nonlocal parameter. Wave propagation is proposed technique to establish field equations of model subjected to four distinct end supports. The significance of scale effect in relevance of length-to-diameter and thickness- to- radius ratios are discussed and displayed in detail.

Effective Application Method for Pollution Mitigation Facility of Highway Runoff (고속도로 비점오염저감시설의 효율적 적용 방안)

  • Lee, Yong-Bok;Choi, Sang-Il;Jung, Hyun-Gyu;Bae, Sei-Dal;Jung, Sun-Kook
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.6
    • /
    • pp.1264-1271
    • /
    • 2011
  • To build environmentally friendly highways, we testes suitability for unique characteristics of pollution mitigation facility around the highways by evaluating optimal selections and implementation methodologies to minimize loan of non-point pollution substances into water-ways. To do this we categorized EIA target highways into three types ; big drainage basin, small drainage basin, and bridge section as to minimize non-point pollution of highway runoff. The terms of selected facility test based on the Natural and Manufactured Treatment Device were removal efficiency of TSS, BOD, COD, T-N, T-P, compatibility of site selection, economic feasibility, maintenance convenience, and the final mitigation facility.

STM Observation of Pt{111}(3$\times$3)-CI and c(4$\times$2)-CI Structures

  • Song, M.B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.3
    • /
    • pp.267-270
    • /
    • 2001
  • The adsorption of chlorine on a Pt(111) surface at 90 K has been studied using scanning tunneling microscopy (STM) in ultra-high vacuum environments. The adsorbed chlorine atoms give rise to two different ordered structures, (3${\times}$3)-Cl and c(4${\times}$2)- Cl, depending on the coverage. It has been determined from the STM image that the absolute coverage of (3${\times}$3)-Cl structure is 0.44, which is not in agreement with coverage calibrated by a low energy electron diffraction technique together with an Auger electron spectrometer and a thermal desorption spectrometer. The Cl atoms bound to on-top sites at the Pt(111)(3${\times}$3)-Cl surface appeared to effectively perturb the density of states of Pt atoms, as compared with that bound to bridging sites. The other ordered structure, c(4${\times}$2)-Cl, with small domain sizes, consists of both on-top and bridge-bonded species with a saturation coverage of 0.5.