• Title/Summary/Keyword: Small animal PET

Search Result 54, Processing Time 0.034 seconds

Development of Position Encoding Circuit for a Multi-Anode Position Sensitive Photomultiplier Tube (다중양극 위치민감형 광전자증배관을 위한 위치검출회로 개발)

  • Kwon, Sun-Il;Hong, Seong-Jong;Ito, Mikiko;Yoon, Hyun-Suk;Lee, Geon-Song;Sim, Kwang-Souk;Rhee, June-Tak;Lee, Dong-Soo;Lee, Jae-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.469-477
    • /
    • 2008
  • Purpose: The goal of this paper is to present the design and performance of a position encoding circuit for $16{\times}16$ array of position sensitive multi-anode photomultiplier tube for small animal PET scanners. This circuit which reduces the number of readout channels from 256 to 4 channels is based on a charge division method utilizing a resistor array. Materials and Methods: The position encoding circuit was simulated with PSpice before fabrication. The position encoding circuit reads out the signals from H9500 flat panel PMTs (Hamamatsu Photonics K.K., Japan) on which $1.5{\times}1.5{\times}7.0\;mm^3$ $L_{0.9}GSO$ ($Lu_{1.8}Gd_{0.2}SiO_{5}:Ce$) crystals were mounted. For coincidence detection, two different PET modules were used. One PET module consisted of a $29{\times}29\;L_{0.9}GSO$ crystal layer, and the other PET module two $28{\times}28$ and $29{\times}29\;L_{0.9}GSO$ crystal layers which have relative offsets by half a crystal pitch in x- and y-directions. The crystal mapping algorithm was also developed to identify crystals. Results: Each crystal was clearly visible in flood images. The crystal identification capability was enhanced further by changing the values of resistors near the edge of the resistor array. Energy resolutions of individual crystal were about 11.6%(SD 1.6). The flood images were segmented well with the proposed crystal mapping algorithm. Conclusion: The position encoding circuit resulted in a clear separation of crystals and sufficient energy resolutions with H9500 flat-panel PMT and $L_{0.9}GSO$ crystals. This circuit is good enough for use in small animal PET scanners.

Biodistribution and PET imaging of [18F]FMISO in mousecolon cancer xenografted mice

  • Seelam, Sudhakara Reddy;Lee, Ji Youn;Kim, Young Joo;Lee, Yun-Sang;Jeong, Jae Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.2
    • /
    • pp.137-144
    • /
    • 2015
  • Hypoxia is an important adverse prognostic factor for tumor progression and is a major cause of failure of radiation therapy. In case of short-term hypoxia, the metabolism can recover to normal, but if hypoxia persists, it causes irreversible cell damage and finally leads to death. So a hypoxia marker would be very useful in oncology. In particular, 2-nitroimidazole can be reduced to form a reactive chemical species, which can bind irreversibly to cell components in the absence of sufficient oxygen, thus, the development of radiolabeled nitroimidazole derivatives for the imaging of hypoxia remains an active field of research to improve cancer therapy result. 2-nitroimidazole based hypoxia marker, [$^{18}F$]FMISO holds promise for the evaluation of tumor hypoxia by Positron emission tomography (PET), at both global and local levels. In the present study, [$^{18}F$]FMISO was synthesized using an automatic synthesis module with high radiochemical purity (>99%) in 60 min. Immunohistochemical analysis using pimonidazole confirmed the presence of hypoxia in xenografted CT-26 tumor tissue. A biodistribution study in CT-26 xenografted mice showed that the increased tumor-to-muscle ratio and tumor-to-blood ratios from 10 to 120 min post-injection. In the PET study, [$^{18}F$]FMISO also showed increased tumor-to-muscle ratios from 10 to 120 min post-injection. In conclusion, this study demonstrates the feasibility and utility of [$^{18}F$]FMISO for imaging hypoxiain mouse colon cancer model using small animal PET.

Development of a Bio-mimetic Entertainment Robot with Autonomous Feeding Functionality

  • Cho, Ik-Jin;Choi, Byoung-Jun;Jeong, Kil-Woong;Lee, Yun-Jung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1525-1529
    • /
    • 2004
  • Most of the recently developed robots are human friendly robots which imitate an animal or human such as entertainment robot, bio-mimetic robot and humanoid robot. Interest in these robots are increasing since the social trend is focused on health, welfare, and graying. By these social backgrounds, robots become more human friendly and suitable for home or personal environment. The more bio-mimetic robots resemble living creature, the more human feels familiarity. People feel close friendship not only when they feed a pet, but also when they watch a pet having the food. Most of entertainment robots and pet robots use internal-type batteries and have a self-recharging function. Entertainment robots and pet robots with internal-type batteries are not able to operate during charging the battery. So far there have been a few robots that do not depend on a battery. However, they need a bulky energy conversion unit and a slug or foods as an energy source, which is not suitable for home or personal application. In this paper, we introduce a new bio-mimetic entertainment robot with autonomous feeding functionality, called ELIRO-1(Eating LIzard RObot version 1). The ELIRO-1 is able to find a food (a small battery), feed by itself and evacuate. We describe the design concept of the autonomous feeding mechanism of the ELIRO-1, characteristics of sub-parts of the manufactured mechanism and the control system.

  • PDF

Age-related digestibility of nutrients depending on the moisture content in aged dogs

  • Kim, Ki Hyun;Seo, Kangmin;Cho, Hyun-Woo;Jeon, Jung-Hwan;Kim, Chan Ho;Jung, Jiyeon;Chun, Ju Lan
    • Journal of Animal Science and Technology
    • /
    • v.63 no.6
    • /
    • pp.1355-1361
    • /
    • 2021
  • Digestibility of pet food can affect the health of dog, especially of aged animals. To maintain the health of dogs in an overall good status it is necessary to provide nutritionally balanced food. For example, the digestibility of dogs was known to be decreased along aging. In addition, losing teethes is an often event in aged dogs that could induce a problem to eat a large size dry pet food. Nonetheless, few detailed information is available on the most suited feeding for aged dogs. As part of the nutritional study of food for aged dogs, in this study, we tested whether food type impacts on digestibility on adult versus senior dogs. The methodology to measure the digestibility of nutrients was chosen the index method using chromium oxide. Dogs were fed the same commercial dry or wet diets, which were supplemented with 0.5% chromium oxide. The wet food was prepared by adding twice volume of water in the dry food prior to incubated overnight (14-16 hours) at room temperature. After five days, their feces were collected up to a total weight of > 200 g which was the amount to analyze undigested nutrients in feces as 3 repeats. In the apparent total tract digestibility analysis of the experimental breed, no difference in the digestibility of crude protein, crude fat, crude fiber, ash, and energy was observed regarding the moisture content of the food. Noteworthy, the digestibility of nitrogen free extract was significantly increased in senior dogs fed dry dog food compared with adult dogs fed the same diet, whereas no difference was observed between senior and adult dogs fed wet food. The small breed dogs showed similar results to the experimental breed dogs. However, the digestibility of crude fat was additionally affected by age and food type unlike the experimental breed dogs. This finding suggests that the food moisture content affects the digestibility of nutrients in dogs with aging. Hence, it may be helpful to determine the nutrient contents in foods for senior dogs depending on the food type.

Analysis of the Influence of Street Trees on Human Thermal Sensation in Summer (여름철 인간 열환경지수에 미치는 가로수의 영향 분석)

  • Jo, Sang-man;Hyun, Cheol-ji;Park, Soo-kuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.5
    • /
    • pp.105-112
    • /
    • 2017
  • In order to analyze the effect of street trees on human thermal sensation(thermal comfort) in summer, microclimatic data were measured and analyzed at sunny and shaded locations of two deciduous broadleaf and three broadleaf evergreen species of street trees. As a result, the mean differences by species in air temperature, relative humidity and wind speed were small: $0.2{\sim}1.5^{\circ}C$, 0.9~5.3% and $0.1{\sim}0.5 ms^{-1}$, respectively, but the mean difference in the mean radiant temperature was great, $27.1^{\circ}C$. In the results of physiological equivalent temperature(PET) and universal thermal climate index(UTCI), which are human thermal sensation(thermal comfort) indexes, the shaded locations by the trees showed mean reduction rates of 21.2~31.3% in the PET compared with the sunny location, which are equivalent to 1.5~2.5 levels of thermal perception. Also, 12.7~20.0% in the UTCI was reduced by the trees' shadows, which is equivalent to 1~1.5 levels of heat stress. In addition, although the broadleaf evergreen trees had 5% greater mean reduction in PET than that of the deciduous broadleaf trees, the Zelkova serrata that belonged to the deciduous broadleaf trees showed the equivalent thermal reduction effect as the broadleaf evergreen trees because of the high density of branches and leaves. Therefore, the mean radiant temperature and the density of the crown(branches and leaves) were the main influences in thermal modification by these street trees in summer.

List-event Data Resampling for Quantitative Improvement of PET Image (PET 영상의 정량적 개선을 위한 리스트-이벤트 데이터 재추출)

  • Woo, Sang-Keun;Ju, Jung Woo;Kim, Ji Min;Kang, Joo Hyun;Lim, Sang Moo;Kim, Kyeong Min
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.309-316
    • /
    • 2012
  • Multimodal-imaging technique has been rapidly developed for improvement of diagnosis and evaluation of therapeutic effects. In despite of integrated hardware, registration accuracy was decreased due to a discrepancy between multimodal image and insufficiency of count in accordance with different acquisition method of each modality. The purpose of this study was to improve the PET image by event data resampling through analysis of data format, noise and statistical properties of small animal PET list data. Inveon PET listmode data was acquired as static data for 10 min after 60 min of 37 MBq/0.1 ml $^{18}F$-FDG injection via tail vein. Listmode data format was consist of packet containing 48 bit in which divided 8 bit header and 40 bit payload space. Realigned sinogram was generated from resampled event data of original listmode by using adjustment of LOR location, simple event magnification and nonparametric bootstrap. Sinogram was reconstructed for imaging using OSEM 2D algorithm with 16 subset and 4 iterations. Prompt coincidence was 13,940,707 count measured from PET data header and 13,936,687 count measured from analysis of list-event data. In simple event magnification of PET data, maximum was improved from 1.336 to 1.743, but noise was also increased. Resampling efficiency of PET data was assessed from de-noised and improved image by shift operation of payload value of sequential packet. Bootstrap resampling technique provides the PET image which noise and statistical properties was improved. List-event data resampling method would be aid to improve registration accuracy and early diagnosis efficiency.

Development of Brown Hair-Dye using The Extracts of Boehmeria tricuspis Grown Wild in Korea (한국 자생 거북꼬리 추출물을 이용한 갈색 염모제 개발)

  • Kim Hyun-Ju;Heo Buk-Gu;Park Yun-Jum
    • Korean Journal of Plant Resources
    • /
    • v.19 no.2
    • /
    • pp.243-247
    • /
    • 2006
  • To develop the natural brown hair-dye, we investigated the dyeability of hairs dyed with the extracts of Boehmeria tricuspis and chemical hair-dye and the changes in its colors as affected by the number of washing frequencies. When dyed with the extracts of Boehmeria tricuspis, ${\Delta}E$ values was increased over 11 compared with control and dyed an order of descent YR. ${\Delta}E$ values treated the ashing juice of Japanese cleyera with a mordant was mostly increased about 15.52. Hairs was dyed with the extracts of Boehmeria tricuspis and we investigated L, a, b and ${\Delta}E$ values as affected by the number of washing frequencies. When treated the ashing juice of Japanese cleyera with a mordant, L values was mostly decreased, however, a, b and ${\Delta}E$ values was increased significantly. L values of hairs dyed with the extracts of Boehmeria tricuspis and washed over thirty times became low compared with that dyed with chemical hair-dye and changes in a, b and ${\Delta}E$values of that was small.

A Record of Ornithonyssus bacoti from Pet Rabbit (Lionhead rabbits, Oryctologus cuniculus) in Korea (애완토끼 (Lionhead rabbit, Oryctologus cuniculus)의 집쥐응애 기생 증례)

  • Son, Hwa-Young;Kim, Sang-Hun;Kim, Duck-Hwan;Kim, Nam-Soo;Kim, Hyeon-Cheol;Woon, Jae-Ho;Cho, Jeong-Gon;Park, Bae-Keun
    • Journal of Veterinary Clinics
    • /
    • v.26 no.6
    • /
    • pp.600-602
    • /
    • 2009
  • Ornithonyssus bacoti or so-called tropical rat mite has a wide host range which includes wild rodents and small mammals. The mite is known to bite humans and cause irritation. But the case reports are few in pet rabbits. Two Lionhead rabbits (Oryctologus cuniculus) were referred to the local animal hospital, and many mites were detected on the body. Mites were identified as O. bacoti by the scanning electron microscopical study. This communication describes the first record of pet rabbits affected with O. bacoti in Korea.

Design of a Depth Encoding Detector using Light Guides with Different Reflector Patterns for Each Layer (각 층별 반사체 패턴이 서로 다른 광가이드를 사용한 반응 깊이 측정 검출기 설계)

  • Seung-Jae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.31-36
    • /
    • 2023
  • Among imaging and treatment devices for small animals, positron emission tomography(PET) causes a change in spatial resolution within a field of view. This is a phenomenon caused by using a small gantry and a thin and long scintillation pixel, and detectors that measure the interaction depth are being developed and researched to solve this problem. In this study, a detector that measures the interaction depth was designed using several scintillator blocks and light guides with different reflector patterns. The scintillator block composed of 4 × 4 arrays of 3 mm × 3 mm × 5 mm scintillation pixels formed four layers, and a light guide was inserted in each layer to configure the entire detector. In order to check whether the interaction depth was measured, a gamma ray interaction was generated at the center of all scintillation pixels to acquire data and then reconstructed into a flood image. The reflector patterns of the light guides inserted between the layers were all different, so the positions of the scintillation pixels for each layer were formed in different locations. It is considered that even spatial resolution can be achieved over all regions of the field of view if all positions of the scintillation pixels thus formed are separated and used for image reconstruction.

Periocular Myxoma in a Dog

  • Bae, Jae Hyun;Kim, Jury;Kwon, Seungjoo;Plummer, Caryn;Hillers, Kim;Kim, Min-Su
    • Journal of Veterinary Clinics
    • /
    • v.37 no.1
    • /
    • pp.34-37
    • /
    • 2020
  • A 1-year-old castrated male Shih-Tzu dog presented with severe orbital swelling involving the right eye. Physical examination identified a painless swelling of the right periocular tissues and protrusion of the third eyelid. Radiographic examination revealed a well-delineated, spherical (3 × 3 cm) soft tissue mass. Ultrasonography confirmed a hypoechoic, multilobular, tubular cystic structure with hyperechoic foci. Fine needle aspiration was conducted and the cytologic impression revealed copious mucus, increased neutrophilic leucocytes, and foamy macrophages. Th tentative diagnosis was zygomatic sialocele, and the lesion was resected through lateral orbitotomy. Surgical exploration identified a multilobular mass adhering to the zygomatic glands. Both the zygomatic gland and the mass were removed. Histological findings were consistent with those of an inflamed myxoma. No postoperative recurrence occurred within 1 year.