• Title/Summary/Keyword: Small Scale Grid

Search Result 133, Processing Time 0.031 seconds

DEVELOPMENT OF 2-D UNSTRUCTURED HYBRID GRID GENERATION PROGRAM USING JAVA APPLET (자바 애플릿을 이용한 2차원 혼합형 비정렬 격자 생성 프로그램의 개발)

  • Lee, J.H.;Cho, K.W.;Kim, B.S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.65-70
    • /
    • 2009
  • In this paper a hybrid grid generation program for general 2-D region is introduced. The program is developed by using JAVA programming language, and it can be used either as an application program on a local computer or as an applet in the network environment. The hybrid grid system for a 2-D problem means a combination of triangular cells and quadrilateral cells, and it can offer both of the high flexibility of triangular cells and the high accuracy and efficiency of structured-type quadrilateral cells. To accommodate a quadrilateral-cell region and a triangular-cell region into one computational domain, it is importance to take good care of the interface between two different regions so that overall good grid quality can be maintained. In this research advancing layer method(ALM) augmented by elliptic smoothing method is used for the quadrilateral-cell region and advancing front method(AFM) is used for the triangular-cell region. A special treatment technique for the interface between those two regions is also developed. The interface treatment technique is basically to prevent the propagation of small cell size due to ALM method into the triangular region and maintain the smooth transition of cell-size scale between two different regions. By applying current technique high-quality hybrid grids for general 2-D regions can be easily generated, and typical grid generation results and flow solutions are demonstrated.

  • PDF

Resource Management Scheme in Proxy-Based Mobile Grid (프록시기반 모바일 그리드에서 자원관리 기법)

  • Cho, InSeock;Lee, DaeWon;Lee, HwaMin;Gil, JoonMin;Yu, HeonChang
    • The Journal of Korean Association of Computer Education
    • /
    • v.11 no.5
    • /
    • pp.67-76
    • /
    • 2008
  • Grid computing has a large scale virtual computing environment that enables a collaborative processing through sharing resources of geographically distributed organizations. In recent year, the development of wireless networks and mobile devices enables mobile devices to consider as a resource of the grids. However, there are some problems such as low performance of processors, small capacity of storages, limited capacity of battery, and low bandwidth. In this paper, to overcome these limitations occurred in mobile grid environments, we proposed a proxy-based mobile grid system. Our proposed system enables mobile devices to play roles as a resource consumer and a resource provider and to collaborate with wired grids through a mobile router. Also, we propose an adaptive job scheduling scheme to cope with context changes of mobile devices and compare our scheduling scheme with other scheduling schemes using a simulation tool, SimGrid, to verify the validity of our job scheduling scheme.

  • PDF

Design and Control of Grid-connected Photovoltaic system using the state space Modeling (상태공간 모델링을 이용한 계통연계 태양광발전시스템의 설계 및 제어)

  • Hwang, In-Ho;Kim, Si-Kyeong;Seong, Se-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.431-433
    • /
    • 1996
  • It is expected that utility interactive small scale dispersed PV system will be widely diffused in the future. This paper discussed the design and control method of single phase PV inverter system with compensation capability of reactive power including harmonic distortion, based on state space modelling. As the results, compensation effects were suggested by simulation and experiment.

  • PDF

CFD investigation of a JAEA 7-pin fuel assembly experiment with local blockage for SFR

  • Jeong, Jae-Ho;Song, Min-Seop
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3207-3216
    • /
    • 2021
  • Three-dimensional structures of a vortical flow field and heat transfer characteristics in a partially blocked 7-pin fuel assembly mock-up of sodium-cooled fast reactor have been investigated through a numerical analysis using a commercial computational fluid dynamics code, ANSYS CFX. The simulation with the SST turbulence model agrees well with the experimental data of outlet and cladding wall temperatures. From the analysis on the limiting streamline at the wall, multi-scale vortexes developed in axial direction were found around the blockage. The vortex core has a high cladding wall temperature, and the attachment line has a low cladding wall temperature. The small-scale vortex structures significantly enhance the convective heat transfer because it increases the turbulent mixing and the turbulence kinetic energy. The large-scale vortex structures supply thermal energy near the heated cladding wall surface. It is expected that control of the vortex structures in the fuel assembly plays a significant role in the convective heat transfer enhancement. Furthermore, the blockage plate and grid spacer increase the pressure drop to about 36% compared to the bare case.

A Basic Study on the Standard Scale of Architecture in the Late Joseon Dynasty (조선후기 건축의 표준척도 운용에 관한 기초연구)

  • Lee, Kang Min
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.6
    • /
    • pp.105-116
    • /
    • 2018
  • This study deals with 8-cheok(ch"), equivalent to 2.4m as the standard scale of architectural module in Korea. 8ch" of Korean module was a unique dimensions compared to other East-Asian architecture. It is inferred that it spread in Joseon Dynasty by the effects of the law which limited the size of buildings and materials according to social rank. 8ch" module was applied to the Palace architecture and the highest grade mansions rather than common and small houses. The application of 8ch" module changed the process of architectural planning, and bred the essential characteristics of Korean architecture in terms of appearance and techniques. In addition, it developed to gain multiformity of composition by combination of other modules.

A Study on the Comparison of Air Pollutants Emissions according to Three Averaging Methods of Vehicular Travel Speed (자동차 평균통행속도 적용방식에 따른 대기오염 배출량 비교 연구)

  • Cho Kyu-Tak
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.4
    • /
    • pp.401-411
    • /
    • 2005
  • This study was conducted to develop a method to be able to estimate the vehicular emissions according to spatial scales-Seoul province, 25 counties and hundreds of grids $(1km{\times}1km)$. First, the emissions at each spatial scale was calculated by using the road network and the travel volume and speed of each link modeled by travel demand model (TDM). Second, the emission at each spatial scale was calculated on the basis of average speeds estimated by using three kinds of averaging method. These are called the provincial, volume-delay function (VDF) and zonal method, respectively. Third, three kinds of emissions and those by TDM are compared each other at three spatial scales. In Seoul (provincial scale), three kinds of emissions are less than those by TDM, but the differences of TDM from three speed averaging methods (SAMs) are small. The relative ratios of three SAMs to TDM are $88\~90\%\;in\;CO,\;99\~100\%\;in\;NOx,\;84\~85\%$ in VOCs. At county scale, NOx among three pollutants showed the highest correlation between TDM and three SAMs and the zonal method among three SAMs was proven to be the highest correlation with TDM. NOx showed the coefficients $(R^2)$ greater than 0.9 in all three SAMs but CO and VOC showed the coefficients $(R^2)$ greater than 0.9 in only zonal method. Slopes of co..elations of all pollutants showed the values close to '1' in zonal method. In the other two SAMs, slopes of NOx showed the values close to '1', but those of CO and VOC showed the values less than 0.85. At grid scale, correlations between TDM and three SAMs were not high. CO showed $0.68\~0.77\;in\;R^2s\;and\;58\~0.68$ in slopes. NOx showed $0.90\~0.94\;in\;R^2s\;and\;0.86\~0.94$ in slopes. VOC showed $0.56\~0.70\;in\;R^2s\;and\;0.48\~0.57$ in slopes. There are not high correlations between TDM and three SAMs in grid scale. This study showed that there is the most suitable method for calculating the average travel speed at each spatial scale and it is thought that the zonal method is more suitable than the VDF or provincial method.

A Study of a Novel Wind Turbine Concept with Power Split Gearbox

  • Liu, Qian;Appunn, Rudiger;Hameyer, Kay
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.4
    • /
    • pp.478-485
    • /
    • 2013
  • This paper focuses on the design and control of a new concept for wind turbines with a planetary gearbox to realize a power split. This concept, where the generated wind power is split into two parts, is to increase the utilization of the wind power and may be particularly suitable for large scale off-shore wind turbines. In order to reduce the cost of the power electronic devices, a synchronous generator, which is driven by the planetary gear, is directly connected to the power grid without electronic converter. A servo drive, which functions as the control actuator, is connected to the power grid by a power electronic converter. With small scale power electronic device, the current harmonics can also be reduced. The speed of the main shaft is controlled to track the optimal tip speed ratio. Meanwhile the speed of the synchronous generator is controlled to stay at the synchronous speed. The minimum rated power of the servo motor and the converter, is studied and discussed in this paper. Different variants of the wind turbine with a planetary gear are also compared. The controller for optimal tip speed ratio and synchronous speed tracking is given.

Implementation of Two TMS320F28335 based BESS Controllers for Microgrid and Control Performance Test in the Hardware-in-the-Loop Simulation System (마이크로그리드용 2기의 TMS320F28335 기반 BESS 제어기 구현 및 Hardware-in-the-Loop Simulation 시스템을 이용한 제어 성능 테스트)

  • Kim, Nam-Dae;Yoo, Hyeong-Jun;Kim, Hak-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.559-564
    • /
    • 2014
  • A microgrid as a small scale power system is operated by the grid-connected mode and islanded mode. It is anticipated that the battery energy storage system (BESS) is able to be applied to the microgrid for stable power control, such as tie-line and smoothing control in the grid-connected mode and voltage and frequency control in the islanded mode. In this paper, a digital signal processor (DSP), Two BESS controllers based on TMS320F28335 of a microgrid are implemented and are tested to show control performance in the hardware-in-the loop simulation (HILS) system.

Vortex Particle Turbulence for Fluid Simulation (유체 시뮬레이션의 격자 내 상세도 향상을 위한 와류 입자 혼합 기법)

  • Yoon, Jong-Chul;Hong, Jeong-Mo;Kim, Chang-Hun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.14 no.4
    • /
    • pp.1-5
    • /
    • 2008
  • In this paper, we propose an efficient technique for improving the grid based fluid simulation by sub-grid visuals. The detailed turbulency generated efficiently by Vortex Particle Method are blended with the flow fields coming from the traditional incompressible Navier-Stokes solver. The algorithm enables large- and small- scale detail to be edited separately.

  • PDF

Advanced Railway Power Quality Detecting Algorithm Using a Combined TEO and STFT Method

  • Yoo, Je-Ho;Shin, Seung-Kwon;Park, Jong-young;Cho, Soo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2442-2447
    • /
    • 2015
  • Because an electric railway vehicle is a large scale moving load, it can cause various kinds of power quality problems in the railroad power system. The power quality impacts are considered as the strong instantaneous stresses to the related power systems and can cause an accelerating aging and a malfunction of the power supplying components. Therefore, it is necessary to detect the small and intermittent symptoms mixed in the voltage waveform. However, they cannot be detected by the triggering functions of the existing power analyzers installed in the railway systems. This paper will examine the drawback of some fast detection tools and propose an advanced detecting and analyzing method based on a combined TEO and STFT algorithm.