• Title/Summary/Keyword: Small Plant

Search Result 2,225, Processing Time 0.03 seconds

Case report of Johne's disease in Korean black goat (Capra hircus aegagrus) (흑염소에서의 요네병 발생 증례)

  • Rhyoo, Moon-Young;Jung, Ji-Youl;Lee, Kyung-Hyun;Her, Ji-Woong;Bae, You-Chan;Lee, Hyun-Kyoung;Baek, Kang-Hyun;Lee, Bo-Ram;Jean, Young-Hwa;Kim, Jae-Myung;Lee, Myoung-Heon;Yoon, Soon-Seek
    • Korean Journal of Veterinary Research
    • /
    • v.53 no.4
    • /
    • pp.273-276
    • /
    • 2013
  • Two Korean black goat (approx. 2 and 3 years old) showing diarrhea and chronic weight loss were submitted to Animal and Plant Quarantine Agency. At necropsy, there were thickening of small intestine and enlargement of mesenteric lymph nodes. Microscopically, they had granulomatous enteritis in the small and large intestine and granulomatous lymphadenitis. By polymerase chain reaction (PCR) and acid fast stain, strong positive reaction and acid-fast rod bacteria were detected. According to the result of histopathology and PCR, we confirmed this case as Johne's disease. As far as we know, this is the first report of Johne's disease in Korean black goat.

The Optimum Control Study for Improving Efficiency of the small hydropower generation in water pipe (수도관로 소수력발전 운영효율 향상을 위한 최적제어 방안)

  • Hong, Jeong-Jo;Rim, Dong-Heui;Kim, Soo-Sang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.126-129
    • /
    • 2008
  • Using a surplus head in presented water supply pipes, we have studied to improve the operating efficiency of small hydro generator, which was chosen for a test model with Sung-Nam and Bo-Ryong small hydro power plant. With regard to power control and countermeasure of water hammer impact, Finally we have represented the optimal control method through the synthetical analysis of existing system symptoms, operation efficiency, the effect of water hammer impact and system configuration.

  • PDF

Hydrologic Performance Change of Small Scale Hydro Power Plant with Rainfall Condition Change (강우형태변화에 의한 소수력발전소 수문학적 성능의 변화)

  • Park, Wan-Soon;Lee, Chul-Hyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.56-61
    • /
    • 2009
  • The effects of design parameters for small scale hydro power(SSHP) plants due to climate change have been studied. The model to predict hydrologic performance for SSHP plants is used in this study. The results from analysis far rainfall conditions based on KIER model show that the capacity and load factor of SSHP site had large difference between the period. Especially, the hydrologic performance of SSHP site due to rainfall condition of recent period varied in design flowrate sensitively. However climate change gave small effect in load factor of existing SSHP plant. And also, the methodology represented in this study can be used to decide the primary design specifications of SSHP sites.

Identification and Etiological characteristics of Anthracnose Fungi Isolated from Soybean, Small Red Bean and Green Bean (콩, 팥 및 녹두에서 분리한 탄저병균류의 동정과 병원학적 특징)

  • 한경숙;이두형
    • Korean Journal Plant Pathology
    • /
    • v.11 no.1
    • /
    • pp.30-38
    • /
    • 1995
  • Anthracnose fungi associated with soybean (Glycine max), small red bean (Vigna angularis), and green bean (Phaseolus radiatus var. aurea) were compared with respect to cultural characteristics, morphological aspects, and pathogenicity. From the legumes, four different species of Colletotrichum were identified based on their morphological characters : C. truncatum, C. destructivum, C. trifolii and C. gloeosporioides. Colonies of Colletotrichum spp.on culture media varied in colour and growth habits depending upon the media and isolates. In general, formation of conidia, setae, and perithecia on water agar leaf medium was better than that on potato dextrose agar medium under near ultraviolet light. In cross inoculation tests, isolates of C. truncatum, c. destructivum, C. trifolii and C. gloeosporioides could infect soybean, small red bean, and green bean at different growth stages. There were some differences in pathogenicity or susceptibility depending on crops tested. C. truncatum was the most virulent and major pathogenic species among the four species.

  • PDF

AN ANALYSIS OF PERFORMANCE CHARACTERISTICS FOR SMALL HYDRO POWER PLANTS

  • Park, Wan-Soon;Lee, Chul-Hyung;Jeong, Sang-Man
    • Water Engineering Research
    • /
    • v.2 no.1
    • /
    • pp.11-19
    • /
    • 2001
  • A performance prediction model for Small Hydro Power(SHP) sites has been studied and developed. Twelve SHP sites were selected and the performance characteristics were analyzed by using the developed model. Also, primary design specifications such as design flowrate, plant capacity, operational rate were suggested and feasibility for small hydro power sites were estimated. It was found that the design flowrate is most important parameter to exploit SHP plant and the methodology developed in this study can be a useful tool to analyze the performance of SHP sites.

  • PDF

A Study on the Optimal Reactive Power Calculation Method of Induction Generator for Marine Small Hydraulic Power (해양 소수력발전용 유도발전기의 최적 무효전력 산정방식에 관한 연구)

  • Lee, Won-Jae;Oh, Yong-Taek
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.100-107
    • /
    • 2013
  • Since the West Sea experiences a big difference in tides, the output power of the small marine hydroelectric power plant varies with the tide. When an induction generator is used here for small hydroelectric power, the reactive power capacitor should be installed at the generator main bus to compensate for the changes in power. As such, the sizing method for the power compensation of the induction generator is reviewed and an optimal method for compensation is suggested. The self-excitation minimum capacitor capacity method, which prevents high voltages, and the power factor automatic control method, which retains a power factor of greater than 90% are reviewed. The compensation effect of reactive power is confirmed through a case study.

Performance Prediction of Tunnel-Type Small Hydro Power Plants with Diversion Dam

  • Lee, Chul-Hyung;Park, Wan-Soon
    • Solar Energy
    • /
    • v.20 no.2
    • /
    • pp.67-73
    • /
    • 2000
  • This study represents the methodology of performance prediction for small hydro power(SHP) sites. Nine tunnel type SHP sites with diversion dam were selected and the performance characteristics were analyzed by using a developed model. Also, primary design specifications such as design flowrate, plant capacity, and operational rate were suggested and feasibility for tunnel-type SHP sites were estimated. It was found that the design flowrate was most important parameter to exploit SHP plant and the methodology developed in this study was useful tool to analyze the performance of SHP sites.

  • PDF

Experimental Study on Optimal Generation of Methane Hydrate (가스하이드레이트 생성조건 최적화에 관한 실험적 연구)

  • Yoon, Seok-Ho;Lee, Jung-Ho;Lee, Kong-Hoon;Park, Sang-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1317-1321
    • /
    • 2009
  • Natural gas liquefaction plant and LNG carrier needs large capital investment. Therefore a lot of small or middle scale natural gas fields aren't developed due to poor profitability. If natural gas is made to gas hydrate instead of liquefaction, developing small-scale natural gas field can be profitable because building cost of gas hydrate plant and carrier are economical. Because the process of making gas hydrate consumes much energy, the gas hydrate formation process has to be optimized for energy consumption. In this study, gas hydrate formation process was investigated experimentally. Experimental apparatus consists of reactor, pressure regulator, chiller, and magnetic stirrer. 99.95% methane was used to make gas hydrate. Tests were conducted at variable pressure and temperature condition.

  • PDF