Analysis of Performance Characteristic for Small Scale Hydro Power Plant with Long Term Inflow Condition Change (장기유입량 변화에 의한 소수력발전소 성능특성분석)

  • Park, Wan-Soon;Lee, Chul-Hyung
    • New & Renewable Energy
    • /
    • v.5 no.4
    • /
    • pp.39-43
    • /
    • 2009
  • The variation of inflow at stream and hydrologic performance for small scale hydro power(SSHP) plants due to climate change have been studied. The model, which can predict flow duration characteristic of stream, was developed to analyze the variation of inflow caused from rainfall condition. And another model to predict hydrologic performance for SSHP plants is established. Monthly inflow data measured at Andong dam for 32 years were analyzed. The existing SSHP plant located in upstream of Andong dam was selected and analyzed hydrologic performance characteristics. The predicted results from the developed models show that the data were in good agreement with measured results of long term inflow at Andong dam and the existing SSHP plant. Inflow and ideal hydro power potential had increased greatly in recent years, however, these did not lead annual energy production increment of existing SSHP plant. As a results, it was found that the models represented in this study can be used to predict the primary design specifications and inflow of SSHP plants effectively.

  • PDF

Bacterial Common Blight and Fuscous Blight of Small Red Bean caused by Xanthomonas axonopodis pv. phaseoli and X. axonopodis pv. phaseoli var. fuscans (Xanthomonas axonopodis pv. phaseoli와 X. axonopodis pv. phaseoli var. fuscans에 의한 팥의 세균성잎마름병)

  • Lee Seung-Don;Lee Jung-Hee;Moon Jung-Kyung;Heu Sung-Gi;Ra Dong-Soo
    • Research in Plant Disease
    • /
    • v.12 no.2
    • /
    • pp.129-133
    • /
    • 2006
  • A bacterial disease of small red bean (Phaseolus angularis) was observed on field-grown plants in Suwon in year 2003. Leaf symptoms initially appeared as water-soaked spots that gradually enlarged, became flaccid and necrotic and were often bordered by a small zone of lemon yellow tissue. In the case of severe infection, dead leaves were defoliated. Pod symptoms consisted of the lesions that were generally circular, slightly sunken and dark reddish brown. Isolation made from diseased leaves on yeast extract dextrose calcium carbonate agar yielded nearly pure cultures of a yellow-pigmented bacterium typical of a xanthomonad. Three bacterial strains were purified and used for further tests. Pathogenicity of strains was confirmed on 3-week-old small red bean plants sprayed with bacterial suspensions containing $10^8 cfu/ml$ of phosphate buffered saline. The representative Xanthomonas strains isolated from small red bean were compared with X. axonopodis pv. phaseoli and X. axonopodis pv. phaseoli var. fuscans type strains for fatty acid profiles, biochemical tests and metabolic fingerprints using Biolog GN2 microplate, showing that all outcomes were indistinguishable between our isolates and reference strains. Two of three strains produced a melanin-like brown pigment extracellularly on King's medium B agar. These results suggest that this new small red bean disease observed in Suwon is bacterial fuscous blight caused by X. axonopodis pv. phaseoli and X. axonopodis pv. phaseoli var. fuscans.

A Study on the Performance Prediction Methodology of Small Hydropower Plant (소수력발전소의 성능예측 기법에 관한 연구)

  • Park, Wan-Soon;Lee, Chul-Hyung;Jeong, Sang-Man
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.894-898
    • /
    • 2006
  • A model, which can analyze the hydrological performance for small hydropower(SHP) plants having no flow duration characteristics has been studied and developed. System performance of existing SHP plant under operating was analyzed by using the developed model. The annual operational rate of SHP plant showed that the data were in good agreement with predicted results from the model. Based on these results, several SHP sites to be exploited were selected and the performance characteristics were analyzed by using the developed model. Also, primary design values such as design flow rate, plant capacity, and operational rate were suggested. As a result, it was found that the methodology used in this study is useful tool to predict the hydrological system performances of SHP sites.

  • PDF

A Study on the Performance Prediction Methodology of Small Hydropower Plant (소수력발전소의 성능예측기법에 관한 연구)

  • Lee, C.H.;Park, W.S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.742-747
    • /
    • 2005
  • A model, which can analyze the hydrological performance for small hydropower(SHP) plants having no flow duration characteristics has been studied and developed. System performance of existing SHP plant under operating was analyzed by using the developed model. The annual operational rate of SHP plant showed that the data were in good agreement with predicted results from the model. Based on these results, several SHP sites to be exploited were selected and the performance characteristics were analyzed by using the developed model. Also, primary design values such as design flow rate, plant capacity, and operational rate were suggested. As a result, it was found that the methodology used in this study is useful tool to predict the hydrological system performances of SHP sites.

  • PDF

A Research and Analysis on the Actual Condition of Safety Management at Small-Medium Chemical Plant (중소기업 화학 사업장의 안전관리 실태 조사 분석)

  • 이태우
    • Journal of the Korea Safety Management & Science
    • /
    • v.1 no.1
    • /
    • pp.183-195
    • /
    • 1999
  • Most of chemical plant are using toxic and dangerous materials, inflammable and poisonous. There are many accidental dangers by escaping of fire, explosive and poisonous materials in case of high temperature and pressure. The accidents lead to taking employer's and local people's life and environmental contamination. Therefore, 27 small-medium chemical plant, which size is 30 ∼ 200 employees out of safety management agent ill the area of A was selected in this study. The problems of safety management and several countermeasures at the chemical plants was indicated through the analyzed data. Prior to this analysis, top managers' concerns, equipment maintenance for the safety management are needed. For the future, calamity prevention countermeasures by industrial disaster analysis are needed and active safety management programs are investigated for the industrial disaster prevention and productivity enhancement at the chemical plant.

  • PDF

A Research and Analysis on the Actual Condition of Safety Management at Small-Medium Chemical Plant (중소기업 화학 사업장의 안전관리 실태 조사 분석)

  • 이태우;강경식
    • Proceedings of the Safety Management and Science Conference
    • /
    • 1999.11a
    • /
    • pp.97-108
    • /
    • 1999
  • Most of chemical plant are using toxic and dangerous materials, inflammable and poisonous. There are many accidental dangers by escaping of fire, explosive and poisonous materials in case of high temperature and pressure. The accidents lead to taking employer's and local people's life and environmental contamination. Therefore, 27 small-medium chemical plant, which size is 30∼200 employees out of safety management agent in the area of A was selected in this study. The problems of safety management and several countermeasures at the chemical plants was indicated through the analyzed data. Prior to this analysis, top managers' concerns, equipment maintenance for the safety management are needed. For the future, calamity prevention countermeasures by industrial disaster analysis are needed and active safety management programs are investigated for the industrial disaster prevention and productivity enhancement at the chemical plant.

  • PDF

A study on the efficiency of ESS installed in a small solar power plant based on actual data (실측데이터 기반 소규모 태양광발전소 연계용 ESS 효율 분석에 관한 연구)

  • Youn, Geum-Ran;Lee, Tae-kyu;Kim, Jeong-Uk
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.350-357
    • /
    • 2019
  • We analyzed the system efficiency of small solar power plants with 80% of total solar power plants. The data of the solar power plant with installed capacity of 100kW was collected and the correlation of the ESS efficiency according to the capacity of the PCS and the battery of each power plant was deduced. As a result, the higher the C-rate value affecting the discharge rate of the battery, The discharge efficiency of the plasma display panel is increased.