• Title/Summary/Keyword: Small Office Building

Search Result 83, Processing Time 0.027 seconds

Investigation and Estimation of Transformer Load Factor for Rationalization of Transformer's Efficiency (변압기 효율 적정화를 위한 변압기 부하율 조사 및 추정)

  • Kim, Chong-Min;Kim, Young-Seog;Gil, Hyoung-Jun;Shong, Kil-Mok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.96-101
    • /
    • 2016
  • In this paper, We investigate the number of 795 transformer in the private electrical facilities and analyze the annual load factor. The results show that the annual load factor of transformer is 20.16% in manufacturing industry, education services(school) is 9.59%, retail and wholesale services is 19.68%, resort and leisure industry is 10.93%, office building is 13.10%, and apartment houses is 14.69%. Education services, resort and leisure industry are being operated with a very low annual load factor. The relatively small capacity of less than 500kVA transformer also been analyzed that is being operated with a low load factor. Therefore, In order to minimize the power loss of the transformer, it is advisable to complement the Transformer Efficiency Management system to be designed the efficiency is good transformer when the load is low. Analysis results will be used as the basis for the provision of transformer efficiency management system and be used High-efficiency transformers promotion system.

Analysis of Energy Consumption & Environmental Load of Electric Heat Pump and Gas Engine Driven Heat Pump (전기구동 히트펌프(EHP)와 가스엔진구동 히트펌프(GHP)의 에너지소비량 및 환경부하 분석)

  • Kim, Sang-Hun;Lim, Sang-Cae;Chung, Kwang-Seop;Kim, Young-Il
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.933-937
    • /
    • 2006
  • Energy is motive power that makes convenient society. But, our country's energy is depending on most import. Also, energy and environmental issue are important problem in community of nations. The purpose of this study is to analysis the energy consumption and environmental load of EHP and GHP in Medium and small-scaled office building. The annual energy consumption used to cooling and heating by EHP was 10 percent more than GHP. And annual energy cost of EHP was 33 percent more expensive than GHP. But, Compared to the annual $CO_2$ emission, EHP was 6 percent less than GHP. Therefore, equipment selection should be consider environmental load as well as energy consumption and cost.

  • PDF

Design, Deployment and Implementation of Local Area Network (LAN) at BAEC Head Quarter

  • Osman Goni;Md. Abu Shameem
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.4
    • /
    • pp.141-146
    • /
    • 2024
  • A local area network (LAN) is a computer network within a small geographical area such as a home, school, computer laboratory, office building or group of buildings. A LAN is composed of interconnected workstations and personal computers which are each capable of accessing and sharing data and devices, such as printers, scanners and data storage devices, anywhere on the LAN. LANs are characterized by higher communication and data transfer rates and the lack of any need for leased communication lines. Communication between remote parties can be achieved through a process called Networking, involving the connection of computers, media and networking devices. When we talk about networks, we need to keep in mind three concepts, distributed processing, network criteria and network structure. The purpose of this Network is to design a Local Area Network (LAN) for a BAEC (Bangladesh Atomic Energy Commission) Head Quarter and implement security measures to protect network resources and system services. To do so, we will deal with the physical and logical design of a LAN. The goal of this Network is to examine of the Local Area Network set up for a BAEC HQ and build a secure LAN system.

A Basic Study on The Architectural Characteristic of the Group Home in Japan (일본 그룹 홈의 건축적 특징에 관한 기초연구)

  • Yang, Yoon-Sil;Kim, Tae-Il
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.4
    • /
    • pp.248-256
    • /
    • 2014
  • According to data from the national office of Statistics Korea and Ministry of Health and Welfare, as the elderly population increases, the dementia elderly population continues to increase and its future population growth rate is expected to be even faster. In particular, the Dementia Management Act has been in effect since February 2012, and active efforts has been made for a policy for the dementia management. The purpose of this study is to establish standards on building plans based on the appropriate scale and spatial configuration on facilities planning for the elderly with dementia. Specifically, the basic data were collected with a request for a total of 103 points on the basis of a database of group homes in the survey managed by the Japan Association of Group Homes. Specific information of the research includes the management body of facilities operation, scale of the facilities, number of units and configuration of personal living space, and the collected survey data and drawings were statistically proceed and analyzed using the SPSS WIN 20.0. analysis results are summarized as follows. first, most of the group homes come to the small size of the 1-2 story home ; the approximate number of units is one or two per home, and each unit consists of nine rooms. second, a number of group homes with the building area of $300m^2$ have the U-shaped arrangement which is advantageous in the extension and facilities maintenance. In conclusion, this study is to be the fundamental data for judgments that can be used to establish standards for the facilities for the dementia elderly whose population continues to increase. In addition, further study is necessary to establish suitable design conditions of our country.

Critical Review of Global Strategy in Japanese Small- and Medium-sized Companies: A Case of I.S.T Corporation that Dominated the Global Market (일본 중소기업의 글로벌전략과 검토 과제: 세계를 제패한 I.S.T 기업 사례)

  • Kang, Sangmin;Kim, Changju;Tanaka, Mikihiro
    • Journal of East Asia Management
    • /
    • v.1 no.1
    • /
    • pp.29-49
    • /
    • 2020
  • In an intensively competitive global market, small-and medium-sized firms are puzzled about how to develop sustainable competitive advantages against global rivalries, thus leading satisfactory economic performance. However, despite the roles and contributions of such small-and medium-sized firms in the local community and national economies in Japan, little guidance has been offered to the practical issues related to their strategic behaviors toward global management. To fill this notable knowledge gap, this study aims to investigate the conditions in which how Japanese small-and medium-sized could dominates global market, which is one of key challenges in the literature of small business and entrepreneurship. To obtain better insights to this research area, this study undertakes an in-depth interview survey with I.S.T (Industrial Summit Technology) Corporation that shows off the highest global market share (40 per cent) with seamless polyimide tube product widely used in office automation equipment (e.g., copiers and printers). This method of survey is designed to deeply understand historical considerations about how I.S.T Corporation could dominate in the global market of such seamless polyimide tube product. Based on findings drawn from an interview, this study identifies five major factors enabling I.S.T Corporation to be a competitive global hidden company: vision sharing through founder's entrepreneurship, core competence, strategic network, risk management, and employee engagement. Specifically, to become a global hidden champion, sharing the vision motivating employees to partake in shaping company's future will be the first step on the road to global success through founder's entrepreneurship. However, in order to achieve such a vision, the importance of company's core competence cannot be overemphasized, which differentiates your customer solution with those of competitors. As such, a group of experts will be naturally formed and demonstrates your expertise in the global market, thereby building sustainable competitiveness. On the other hand, to maintain sustainable competitiveness, it is necessary to make up for the weaknesses small-and medium-sized firms suffer from competitive resources while strengthening their own strengths through strategic networks with external organizations. Here, every company has to understand the critical role of risk management, which is essential in this process of being global company so as not to lose your own strengths. Last but not least, do not forget the significant effects of employee engagement in firm performance. To enhance employees' engagement, a company has to create an ideal organization culture which fits into company's history and personality. In doing so, such organization culture can allow the vision and strategy to be implemented into detailed business tactics while facilitating employees to challenge the status quo by experimenting with creative ideas.

Evaluation of Reliability of Strain Gauge Measurements for Geosynthetics (토목섬유 보강재에 적용한 스트레인게이지 실측값의 신뢰성 평가)

  • Cho, Sam-Deok;Lee, Kwang-Wu;Li, Zhuang;Kim, Uk-Gie
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.4
    • /
    • pp.87-96
    • /
    • 2015
  • Geosynthetics are widely used in different ways such as reinforcement of structures in road, railway, harbor and dam engineering, drainage, separation and erosion prevention. They are especially applied to reinforced retaining wall and slope or ground reinforcement. Recently, geosynthetics reinforced pile supported (GRPS) embankment was developed to improve stability and construability of embankments in railway engineering. Extension strains are usually measured by strain gauges adhered to geosynthetics to evaluate the stability of geosynthetics. However, the measurements are influenced by manufacturing method and stiffness of geosynthetics and also adherence of strain gauge. In this study, wide-width tensile strength tests were performed on three types of geosynthetics including geogrid, woven geotextile and non-woven geotextile. During the test, strains of geosynthetics were measured by both video extensometer and strain gauges adhered to the geosynthetics and the measured results were compared. Results show that the measured results by strain gauges have high reliability in case of large stiffness geosythetics like geogrid and woven geotextile, whereas they have very low reliability for small stiffness geosythetics like non-woven geotextile.

A Study on Space Planning of Accommodations for Experiential Activities by Remodeling Closed Schools (폐교를 활용한 체험활동 숙박시설의 공간계획 분석)

  • Byun, Kyeonghwa;Kang, Eun-Jung;Yoo, Changgeun
    • Journal of the Korean housing association
    • /
    • v.26 no.2
    • /
    • pp.111-119
    • /
    • 2015
  • This study aims to analyze space planning of accommodations in seven closed schools involved in experiential activity programs on Jeju Island, a famous tourist destination in Korea. The results are as follows. First, 35 schools had been closed down in Jeju between 1982 and 2015. Among them, four closed schools were sold, three are currently used by the Jeju special self-government provincial office of education, and 25 are being leased by individuals, village organizations, and other entities. However, they have not been well-operated, and so strategies for the effective management or operation of these closed schools should be developed. Second, there are distinctive differences in space planning of accommodations based on the correlation between experiential activities and the types of participants. If the experiential activity participants are mainly individuals or small groups, the closed school is likely to plan double-bed accommodations and individual bathrooms rather than large group rooms. Third, in order to operate experiential activity programs, closed schools require four different spaces for experiential activities, lodging, dining, and sanitation. The largest space available in each school building is used for experiential activities, and original classrooms are still in use. According to the standard drawing of school architecture, standard classroom size since 1997 has been $7.5{\times}9$ meters, and lodging rooms have mainly been re-planned based on the module of the standard-sized classroom. School cafeterias are utilized as dinning and kitchen spaces. For sanitation purposes, original school restrooms are still used by experiential program participants, while the shower rooms are newly equipped.

A study of the actual conditions and development plan of the 6th industrialization policy: In the view of agricultural management organizations of Chungnam region

  • Lee, Do-Kyung;Kim, Sounghun;Park, Jeong-il
    • Korean Journal of Agricultural Science
    • /
    • v.43 no.4
    • /
    • pp.670-677
    • /
    • 2016
  • The $6^{th}$ industrialization of agricultural areas, which is the strategy to combine the 2nd industry and the 3rd industry with the 1st industry, is one of the main policy strategies of the inistry of agriculture, food and rural affairs in Korea. This policy strategy focuses on the promotion of small- and medium-size farmers or business firms including agricultural management organizations. Even though various policy programs have been implemented for the $6^{th}$ industrialization of agricultural areas, many agricultural management organizations still claim problems. The purpose of this paper is to analyze the actual conditions of policy programs for the $6^{th}$ industrialization of agricultural areas and to suggest a development plan for the $6^{th}$ industrialization policy for agricultural producers. Especially, we focus on the point of view of agricultural management organizations in Chungnam region. The results of this study present some findings as follows: first, the $6^{th}$ industrialization policy in the agricultural area needs to aim at improving software systems, including human resource systems. Second, the policy programs should focus on improving resident's welfare through building more public facilities and amenities. Third, a strategy of selection and a focus on long-term programs are required to increase the efficiency of policy programs for the $6^{th}$ industrialization of agricultural areas.

Energy-Saving and Environmental Evaluation of Water Supply System on Replacing Water Storage Installed Booster Pump System by Direct Connecting Booster Pump System (저수조 설치 펌프직송방식의 수도직결 증압방식 전환에 관한 에너지절약성 및 환경성 검토)

  • Lee, Chulgoo
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.3
    • /
    • pp.7-12
    • /
    • 2015
  • Currently water supply system with water storage is generally applied except for small building such as single-family houses, and water supply system on replacing water storage installed system by direct connecting system has been increasing because of sanitary and energy-saving aspects. The purpose of this study is to evaluate energy-saving and environmental efficiency of direct connecting booster pump system in comparison with the water storage installed system. The architectural condition of the evaluation subject is ten-story apartment house in which sixty households live. To calculate the power consumption of the pump, the volume of water supply was determined from existing data and other data, such as head, efficiency of the pump, was the value used for general application in design office. The power consumption of the water supply pump for one day was 8.5 kWh for direct connecting booster pump system, and 22.5 kWh for water storage installed system, and the former system showed energy savings of 62% compared to the latter system. Reduced power consumption also leads to reduction of $CO_2$ emission. According to the criteria presented in the Korea Energy Management Corporation, reducing the 2,410 kg $CO_2$ emission is possible per year.

A Study of the Friction Factor Unit Considering the Cost of Energy (에너지비용변화에 따른 경제적 단위마찰저항 값에 대한 고찰)

  • Shin, Dong-Shin;Kim, A-In;Lee, Byung-Hyun;Jung, Hyueong-Mok;Lee, Sung-Goo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.1
    • /
    • pp.29-34
    • /
    • 2016
  • The friction factor unit was studied to find a more economic alternative compared to the conventional 30 mmAq/m. The pipe and pump for cooling water piping used in a failing were selected, and the friction factor unit was changed to calculate the pipe diameter and the brake shaft power. Based on current electric charges, After the brake shaft power was converted into operational costs based on current electric charges, then an economic analysis was conducted considering that incorporated the initial installation costs and operational costs for the pump. We found that the friction factor unit when using 20 mmAq/m is more economical than that with 30 mmAq/m, if the piping is used for more than 4 years. The small friction factor unit is desirable when the piping is used for quite a long period of time, and the selection of a more economic friction factor unit should considering the period of usage will be important.