• Title/Summary/Keyword: Small Office Building

Search Result 83, Processing Time 0.025 seconds

A Study on the Architectural Process and the Characteristic of Municipal Building in Busan (부산부청(釜山府廳)의 건축과정과 변용특성)

  • Song, Hye-Young
    • Journal of architectural history
    • /
    • v.29 no.5
    • /
    • pp.7-16
    • /
    • 2020
  • The Municipal Building of Busan was the first western-style building of Korea in 1879. It was also the predecessor of Busan Metropolitan City Hall. On the other hand, the Municipal Building of Busan was a symbolic structure that shows the history of Busan. The Municipal Building of Busan has inherited the construction location and site, including the speciality of Choryangwaegwan, and is a good example of the process of inheriting the authority of the former space through the appropriation of the building. The Municipal Building of Busan was relocated to the edge of the coast in 1934 because a small and dilapidated building failed to function properly. The relocation of the Municipal Building of Busan in 1934 was the origin of changing the coastal space in downtown. As a result, landfill sites along the coast were in the limelight and developed into the downtown area of Busan after Korea's liberation.

A Study of Rent Determinants of Small and Medium-Sized Office Buildings in Seoul Using a Dynamic Panel Model: Focusing on CBD and GBD Comparison (동적패널모형을 활용한 서울시 중소형 오피스 빌딩 임대료 결정 요인 연구: CBD(도심권)와 GBD(강남권) 비교를 중심으로)

  • NaRa Kim;JinSeok Yu;Jongjin Kim
    • Land and Housing Review
    • /
    • v.14 no.4
    • /
    • pp.47-62
    • /
    • 2023
  • Using the dynamic panel model, this study investigates rent determinants for small and medium-sized office buildings in Korea's CBD and Gangnam areas, key business districts. The results reveal that rents for small and medium-sized office buildings in CBD and Gangnam areas are influenced by macroeconomic fluctuations and characteristics of buildings and locations, suggesting a market with both spatial consumer and investment goods attributes. There are several investment implications as follows. First, even if the location in the CBD area is advantageous, the practical limitations in renovating aging small and medium-sized office buildings must be taken into account when investing. Second, parking conditions are a key factor influencing rent prices in CBD areas, so evaluating the parking facilities and improvement potential of small and medium-sized office buildings is essential for investors. Finally, due to the high sensitivity of Gangnam's small and medium-sized office market to macroeconomic trends, it's vital to prioritize monetary policy shifts as a key factor in investment decisions.

Designing and building an efficient small-sized LAN (효율적인 소규모 네트워크 구축)

  • 안봉근;이병수;정현식
    • Korean Management Science Review
    • /
    • v.12 no.3
    • /
    • pp.97-115
    • /
    • 1995
  • Information sharing and automated office in the use of PC necessitate corporate network to implement business innovation. Building an efficient network requires competent knowledge on capabilities of various LAN technologies, hardwares and softwares that have rapidly improved in terms of efficiency and cost. This paper compares capabilities of network components: communication protocol, hardware, network operation system, low cost database software and mid-range priced SQL for application development. Also this study presents a new technology on virtual LAN and a selection guide among the various options of the network components which are suitable for PC-based small-sized network in balance of efficiency with economy. In the last section of this paper, a case of small-sized network is given for illustration.

  • PDF

Energy Retrofit and Estimate for Small-to-Medium Office Buildings (중소규모 사무소건물의 에너지 개보수 방안 및 평가)

  • 정영선;허정호;방기영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.4
    • /
    • pp.279-288
    • /
    • 2001
  • This paper is to derive energy retrofit strategies through energy audit and analysis for a selected small-to-medium office building located in Seoul, Korea,. To activate ESCO business in Korea, our final goal is to develope a simple and adequate energy retrofit procedure through computer simulation. Calibration process was fairly successful eve without the aid of tough field measurement. In terms of annual energy consumption, the percent difference between the predicted and the monitored values were within a reasonable tolerance of $\pm10$%. Based on the calibrated baseline model and the systematic investigation of target building, retrofit measures were suggested with two categories such as architectural side and equipment side. Both selected parametric and interactive retrofit measure simulations resulted in various energy saving quantities and cost, thus the priority among the measures were made. If we were to select the more realistic and reasonable retrofit measure in future, economic estimate were should be practiced with the life cycle cost analysis.

  • PDF

A Study on Energy Use Monitoring and Analysis Case for Small and Medium-Sized Buildings (중소형 건물에 적합한 에너지사용량 모니터링 및 분석 사례 연구)

  • Lee, Hye-Jin;Kim, Myung-Jin;Kim, Jin-Ho;Lee, Dongho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.5
    • /
    • pp.499-509
    • /
    • 2019
  • This paper discusses energy use monitoring and analysis as part of a study on a low-cost energy supply management system that links an existing database with weather information with no real-time monitor for energy demand of buildings using renewable energy, generator and energy storage systems. This study is targeted at small and medium-sized buildings and aims to monitor energy use with a small number of sensors at low cost by applying an energy management system (EMS). The present study can help overcome the limitations of high-cost EMS applied to large commercial and public buildings. We developed current, indoor temperature and human motion sensors and installed them in an office of a company in a sample building. Through these sensors, we analyzed energy use patterns and the effects of weather information and human motion on the energy use. Furthermore, we analyzed the correlations between the total KEPCO energy use of the sample building and weather by comparing these two data. The results showed that the office energy use of a company was more affected by human motions than by weather information. The comparison between the total energy use of the Building and weather information found that external temperature had an effect on the energy use.

Sustainable Design and Its Cost: Case Study of Nanning China Resources Tower

  • Lai, Stephen Y.F.
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.4
    • /
    • pp.323-326
    • /
    • 2017
  • Sustainability is becoming more and more important in our everyday lives. Thus, it is apparent that more sustainable initiatives are incorporated in a building design concept to reduce operation costs and environmental impacts. However, will the construction cost go up if the building is going green - especially if it is a tall building? This is the question on everyone's mind. In the following paragraphs, we will look into a case study of a skyscraper in Nanning, China. That 411-metre skyscraper, Nanning China Resources Centre East Office Tower, is currently under construction. Designed to LEED-CS Gold standards, the building has adopted a number of sustainable design elements and operation practice, which indeed only accounts for a small percentage of the total construction cost.

Remodeling and Extension of reused Goon(郡) Office Buildings in the Japanese Colonial Period (일제강점기 기존 건물을 전용한 군청사의 개축 및 증축 양상)

  • Kim, Myungsun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4992-4998
    • /
    • 2015
  • The purpose of this study is to investigate that which Goon office buildings were reused from existing buildings and to identify remodeling and extension ways of the reused to match Goon's administration work. This study used literature research method, i.e., analysing the digital images, the annotation, and the official documents between the Japanese government-general of Korea and To(道), and articles of newspapers and journals. The reused were governmental offices of Joseon(朝鮮) dynasty, existing Goon office buildings of Korean empire government and old buildings with unknown purposes. They were remodelled and extended to match Goon's administration work. Common remodelling was making large space with desks for civil petitions and projecting an small entrance from the center of main building's facade. Common extension was constructing accessory buildings with simple wooden structure, locating them to back or side of the reused, and connecting them through external corridor. As many as 30% of 218 Goon office buildings were reused. About 57% of them were replaced as new office buildings, however the number of the new was rapidly decreased after mid 1930s.

Technology Trends in Additively Manufactured Small Rocket Engines for Launcher Applications (발사체 소형엔진용 적층제조 기술 동향)

  • Lee, Keum-Oh;Lim, Byoungjik;Kim, Dae-Jin;Hong, Moongeun;Lee, Keejoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.2
    • /
    • pp.73-82
    • /
    • 2020
  • Additively manufactured, small rocket engines are perhaps the focal activities of space startups that are developing low-cost launch vehicles. Rocket engine companies such as SpaceX and Rocket Lab in the United States, Ariane Group in Europe, and IHI in Japan have already adopted the additive manufacturing process in building key components of their rocket engines. In this paper on technology trends, an existing valve housing of a rocket engine is chosen as a case study to examine the feasibility of using additively manufactured parts for rocket engines.

A Case Study on the Building Energy Savings through HVAC System Optimization Process (공조시스뎀 최적화를 통한 건물에너지 절감사례 연구)

  • Huh Jung-Ho;Kwon Han-Sol;Han Soo-Gon;Ihm Pyeong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.5
    • /
    • pp.426-433
    • /
    • 2006
  • The requirements for the optimal building system design is numerous. However, most system designers do not take care of various design strategies. They often argue that the proper simulation tools are not existed to solve the implicated design requirements and the time to consider many alternatives of building systems are insufficient. The aim of this study is to develop the optimization interface program that considers various system design variables and eventually find both the optimal values of annual energy use and cost. Therefore, Doe2Opt is developed to easily perform simulation-optimization process based on DOE2 and GenOpt, and minimizes energy cost of small-to-medium sized building for 6.7% and that of large sized building for 3% with optimizing several HVAC system variables.

A Study on Predication model for TVOC Emissions of Finishing material in Apartment House (공동주택 건축내장재의 TVOC 방출량에 관한 예측모델 연구)

  • Kim, Hyung-Soo;Lee, Kyung-Hoi
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.55-62
    • /
    • 2002
  • While cognition about an environment pollution becomes important recently, the intense pollution measures about an indoor air environment is required. In the case of building indoor environment, over 80% of modem people is living in building and these days an interest of building interior materials which becomes a reason for indoor environmental pollution in public house, office, is increasing. An experimental measurement method of this study is as follows. (1) American EPA TO-17, ASTMD5116-97, measurement method in VOCs experiment of Japanese closet industrial association (2) 2.4-DNPH cartridge method in HCHO experiment, based on American EPA TO-11 and measurement method of Japanese closet industrial association (3) standard compound is analyzed by using HPLC after solvent extraction process (4) paint and furniture are selected as measurement objects (5) we also made small chamber to grasp an emission characteristic of HCHO and VOCs and to get an environment-amicable forecast model through it, then we developed the model which can forecast emission rate by chamber experiment.