Modification of Microclimate to Improve Milk Production in Tropical Rainforest of Thailand

  • Suriyasathaporn, W.;Boonyayatra, S.;Kreausukon, K.;Pinyopummintr, T.;Heuer, C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.6
    • /
    • pp.811-815
    • /
    • 2006
  • The objective of this study was to evaluate the effect of electric fan installation for milk production improvement of dairy cattle in Thailand. The study was conducted using 2 small-holder dairy farms in Chiang Mai province, during April to August 2004. Electric fans were installed in front of each row of cows. Each of the two rows of cows in the barn was defined as an experimental unit, thus each farm had two experimental units. The fans were operated alternately in 7-day intervals between rows of cows within each farm during the day or between 8.00 am to 8.00 pm. Non-operation periods were used as control. Milk yields were recorded. Data on environmental temperature and humidity were obtained from Chiang Mai Meteorological Center. Result from statistically analysis of milk record suggested an interaction between lactation period and fan installation. Therefore, this interaction term of lactation period and fan installation (PERIOD_FAN) was added as a variable to the regression model. Due to the repeated data collection of milk yield from the same cow (alternate week), milk yield was analyzed by repeated measure analysis (Mixed model). Least square means were calculated for all levels and used to compare between each pair-wise values. The final data were collected from the total of 18 cows with 2,072 data. Overall means and SEM of milk yields and days in milk separated into farm were $14.7{\pm}0.06kg/day$ and $176.3{\pm}2.2days$, and $15.2{\pm}0.22kg/day$ and $202.5{\pm}3.7$ days for farm A and farm B, respectively. For multivariable analysis, only PERIOD_FAN and humidity were significantly associated with milk yield. Only the first period of lactation showed that the amount of milk yields during fan installation was higher than that of non-fan installation (p<0.05). Cows with fan installation produced approximately 1.2 kg/cow more milk than cows without fan installation during this period. In conclusion, the use of electric fan operated during the day time increased milk production of cows during the first period of lactation.

Optimization of Parallel Code for Noise Prediction in an Axial Fan Using MPI One-Sided Communication (MPI 일방향통신을 이용한 축류 팬 주위 소음해석 병렬프로그램 최적화)

  • Kwon, Oh-Kyoung;Park, Keuntae;Choi, Haecheon
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.7 no.3
    • /
    • pp.67-72
    • /
    • 2018
  • Recently, noise reduction in an axial fan producing the small pressure rise and large flow rate, which is one type of turbomachine, is recognized as essential. This study describes the design and optimization techniques of MPI parallel program to simulate the flow-induced noise in the axial fan. In order to simulate the code using 100 million number of grids for flow and 70,000 points for noise sources, we parallelize it using the 2D domain decomposition. However, when it is involved many computing cores, it is getting slower because of MPI communication overhead among nodes, especially for the noise simulation. Thus, it is adopted the one-sided communication to reduce the overhead of MPI communication. Moreover, the allocated memory and communication between cores are optimized, thereby improving 2.97x compared to the original one. Finally, it is achieved 12x and 6x faster using 6,144 and 128 computing cores of KISTI Tachyon2 than using 256 and 16 computing cores for the flow and noise simulations, respectively.

Characteristics of Sawdust and Cocopeat Beddings, and Their Usefulness According to the Fan and Pen Location for Rearing Hanwoo Cattle

  • Ahn, Gyu Chul;Jang, Sun Sik;Lee, Kang Yeon;Kwak, Wan Sup;Oh, Young Kyun;Park, Keun Kyu
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.3
    • /
    • pp.444-454
    • /
    • 2016
  • This study was designed to examine the characteristics of sawdust and cocopeat bedding materials, including physicochemical properties (Exp. I) and on-farm trial (Exp. II). In Exp. I, the proportion of particle size was in the order of sawdust>cocopeat India>cocopeat Vietnam (p<0.05), and cocopeat contained higher proportion of small particles ($250{\mu}m$+below $250{\mu}m$) than sawdust, causing a dust production problem. Bulk density was cocopeat India>cocopeat Vietnam>sawdust (p<0.05), thus cocopeat treatments showed 4.4 times higher bedding cost than sawdust. The water absorption rates were 702.0% in cocopeat India, 678.3% in cocopeat Vietnam, and 444.0% in sawdust, showing cocopeat had approximately 1.5 times higher water absorption rate than sawdust. Moisture evaporation rates after 12 h of air blowing (2.00 m/s) were higher (p<0.05) in cocopeat Vietnam (80.4%) than sawdust (71.2%) and cocopeat India (72.8%). In vitro ammonia emissions were higher (p<0.05) in sawdust ($2.71mg/m^2/h$) than cocopeat India ($1.59mg/m^2/h$) and Vietnam ($1.22mg/m^2/h$), and total ammonia emissions were higher (p<0.05) in sawdust ($37.02mg/m^2$) than cocopeat India ($22.51mg/m^2$) and Vietnam ($13.60mg/m^2$). In Exp. II, an on-farm trial was conducted with 48 Hanwoo cattle in 16 pens using the same bedding materials as in Exp. I, with fan (blowing 2.00 m/s) and no fan treatments, and feed bunk side (FB) and water supply side (WS) within a pen (4.5 m, $width{\times}9.0m$, length). Beddings were replaced with fresh bedding materials when moisture concentrations were over 65%. No interactions among treatments were detected for moisture concentration and increment rates, and ammonia concentrations, but a significant effect was observed (p<0.01) for each of the treatments. Both concentrations and increment rate of moisture were higher (p<0.01) in the beddings without fan than with fan. Moisture concentrations and increment rate within a pen were also higher (p<0.01) in FB than WS. Thus, the whole no-fan-FB and sawdust-fan-FB were replaced with fresh bedding material between 4 to 5 experimental weeks. The ammonia concentrations and pH of beddings were not significantly different among treatments. Therefore, using cocopeat bedding with a blowing fan can extend twice the bedding utilization period, and WS within a pen showed twice the bedding-life compared to FB. Despite the outstanding characteristics of cocopeat compared with sawdust, using cocopeat as an alternative for sawdust bedding is not recommended for cattle management, considering it has 4.4 times higher bedding cost and a dust production problem.

Fabrication of Micro-Heatsink using Nanotemplate (나노 템플레이트를 이용한 마이크로 히트 싱크)

  • 함은주;손원일;홍재민
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.1
    • /
    • pp.7-11
    • /
    • 2003
  • The semiconductor chips or electronic components generate heat, which causes malfunction of the parts when it was not cooled properly. Bulky heat sink and cooling fan are used to get rid of the heat. However, with this bulky system, it is hard to integrate the electronics system in a small scale. The cooling efficiency of the system depends on the surface area of the heat sink, thermal conductivity of the material and the method of integration. In order to develop a novel cooling system, a micro-heatsink with a large surface area while retaining small volume was fabricated by electroless deposition of gold/copper inside a Track-etched membrane. The structure of the micro-heatsink was investigated using SEM or optical microscope. It was also found that the micro-heatsink is more efficient than a flat copper plate.

  • PDF

A Study on the Design of Free-Fall Simulator using concept of Vertical Wind Tunnel (수직형 풍동을 응용한 고공강하 시뮬레이터의 설계에 대한 연구)

  • Choi, Sang-Gil;Cho, Jin-Soo
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.447-452
    • /
    • 2000
  • In this study, the design of Free-Fall Simulator was carried out using concept of vertical wind tunnel. Free-Fall Simulator is not an experimental equipment but a training equipment. Therefore Free-Fall Simulator needs a large training section compared with test section of wind tunnel and has critical limit of height. These limits bring about the difficulty of design for a return passage. Due to small area ratio, the downstream flow of training section with high speed is not decelerated adequately to the fan section. High-speed flow leads to great losses in the small area ratio diffuser and corner. So design of diffusers and corners located between training section and fan section has a great effect on the Free-Fall Simulator performance. This study used an estimation method of subsonic wind tunnel performance. It considered each section of Free-Fall Simulator as an independent section. Therefore loss of one section didn't affect loss of other sections. Because losses of corner with vane and $1^{st}$ diffuser are most parts of overall Free-Fall Simulator, this study focused on the design of these sections.

  • PDF

Development of devices and methods for simulation of hurricane winds in a full-scale testing facility

  • Huang, Peng;Chowdhury, Arindam Gan;Bitsuamlak, Girma;Liu, Roy
    • Wind and Structures
    • /
    • v.12 no.2
    • /
    • pp.151-177
    • /
    • 2009
  • The International Hurricane Research Center (IHRC) at Florida International University (FIU) is pursuing research to better understand hurricane-induced effects on residential buildings and other structures through full-scale aerodynamic and destructive testing. The full-scale 6-fan Wall of Wind (WoW) testing apparatus, measuring 4.9 m tall by 7.3 m wide, is capable of generating hurricane-force winds. To achieve windstorm simulation capabilities it is necessary to reproduce mean and turbulence characteristics of hurricane wind flows. Without devices and methods developed to achieve target wind flows, the full-scale WoW simulations were found to be unsatisfactory. To develop such devices and methods efficiently, a small-scale (1:8) model of the WoW was built, for which simulation devices were easier and faster to install and change, and running costs were greatly reduced. The application of such devices, and the use of quasiperiodic fluctuating waveforms to run the WoW fan engines, were found to greatly influence and improve the turbulence characteristics of the 1:8 scale WoW flow. Reasonable reproductions of wind flows with specified characteristics were then achieved by applying to the full-scale WoW the devices and methods found to be effective for the 1:8 scale WoW model.

Experimental Study on the Development of Food Drying Machine for Home Use Using Low Electricity (저전력 가정용 식품건조기 개발에 관한 실험적 연구)

  • Kim, Soon-Ho;Kim, Ki-Wan;Kim, Hoon
    • Journal of Power System Engineering
    • /
    • v.19 no.4
    • /
    • pp.43-49
    • /
    • 2015
  • This study has been analyzed and investigated the possibility for the substitution of a heat source with the application of PTC(Positive Temperature Coefficient Heater) in a food drying machine. And this experiment was conducted to measure temperatures at the upper part of the vessel and the heat sink. And the structure has the many holes plane connected with the external air in the upper part of similar volumetric vessel, and attached to the PTC heater (3sets) of total consumption electricity of 120[W] in Al radiant heat structure and the small fan (2sets) in the suitable space of the lower part. Consequently, it was found that at the most conditions of food drying test with the seven holes(5mm) under the control temperature $62^{\circ}C$, the optimum drying condition formatted and the optimum time range especially appeared from 6,500 second to 7,000 second in case of drying test on banana sample.

Temperature Control of the Aluminum Plate using Peltier Element (펠티어 소자를 이용한 알루미늄 판의 온도 제어)

  • 전원석;방두열;최광훈;권대규;김남균;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.764-767
    • /
    • 2004
  • This paper present the temperature control of aluminum plate using Peltier element. Peltier effect is heat pumping phenomena by electric energy as one of the thermoelectric effect. So if current is asserted to Peltier element, it absorbs heat from low temperature side and emits to high temperature side. In this experiment, Peltier element is used to control the temperature of small aluminum plate with ON/OFF control scheme and fan ON/OFF. As the result of experiments, it is proper to act fan only while cooling duration and there exist a proper cooling current to drop temperature rapidly. It takes about 100sec to increase to 7$0^{\circ}C$ and drop to 35$^{\circ}C$ of aluminium plate temperature and about 90sec to increase to 7$0^{\circ}C$ and drop to 4$0^{\circ}C$ in ambient temperature 3$0^{\circ}C$ while fan is on only in cooling duration. Future aim is to realize more rapid temperature control and develop SMHA(special metal hydride actuator) by using Peltier element to heating and cooling.

  • PDF

Temperature Control of Aluminum Plate by PWM Current Control of Peltier Module (펠티어 소자의 PWM 전류제어를 이용한 알루미늄 판의 온도제어)

  • Pang, Du-Yeol;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.10
    • /
    • pp.60-67
    • /
    • 2006
  • This paper presents the temperature control in aluminum plate with Peltier module. From the experimental work, Peltier module is used to control the temperature of small aluminum plate for both heating and cooling with the control of current and fan ON/OFF. And current control of Peltier module was accomplished by PWM method. As a result of experiments, it is proper that operate cooling fan only while cooling duration and there exist a proper cooling current to drop temperature rapidly. It takes about 125sec to control temperature of aluminium plate between $30^{\circ}C$ and $70^{\circ}C$ and about 70sec between $40^{\circ}C$ and $60^{\circ}C$, in ambient temperature $28^{\circ}C{\sim}29^{\circ}C$ while cooling fan is operated only cooling duration. With the cooling current, temperature control of aluminum plate was accomplished more rapidly in comparison without cooling current. Future aim is to realize more rapid temperature control and develop SMHA(special metal hydride actuator) by using Peltier module as a heating and cooling source.

Temperature Control using Peltier Element by PWM Method

  • Pang, Du-Yeol;Jeon, Won-Suk;Choi, Kwang-Hoon;Kwon, Tae-Kyu;Kim, Nam-Gyun;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1400-1404
    • /
    • 2005
  • This paper presents the temperature control of aluminum plate by using Peltier element. Peltier effect is heat pumping phenomena by electric energy as one of the thermoelectric effect. So if current is charged to Peltier element, it absorbs heat from low temperature side and emits heat to high temperature side. In this experiment, Peltier element is used to control the temperature of small aluminum plate with current control and operating cooling fan only while cooling duration. Operating cooling fan only while cooling duration is proper to get more rapid heating and cooling duration. As a result of experiment, it takes about 100sec period to repeating temperature between $35^{\circ}C$ and $70^{\circ}C$ and about 80sec from $40^{\circ}C$ to $70^{\circ}C$ in ambient air temperature $25^{\circ}C$ and while operating cooling fan only in cooling duration. Future aim is to apply this temperature control method in actuating SMHA(special metal hydride actuator) which is applicable in Siver project acting in low frequency range by using Peltier element for heating and cooling.

  • PDF