• 제목/요약/키워드: Small Bore

검색결과 76건 처리시간 0.023초

Comparative Study for the Efficacy of Small Bore Catheter in the Patients with Iatrogenic Pneumothorax

  • Noh, Tae-Ook;Ryu, Kyoung-Min
    • Journal of Chest Surgery
    • /
    • 제44권6호
    • /
    • pp.418-422
    • /
    • 2011
  • Background: It has recently become most general to use the small bore catheter to perform closed thoracostomy in treating iatrogenic pneumothorax. This study was performed for analysis of the efficacy of treatment methods by using small bore catheter such as 7 F (French) central venous catheter, 10 F trocar catheter, 12 F pigtail catheter and for analysis of the appropriateness of each procedure. Materials and Methods: From March 2007 to February 2010, Retrospective review of 105 patients with iatrogenic pneumothorax, who underwent closed thoracostomy by using small bore catheter, was performed. We analyzed the total success rate for all procedures as well as the individual success rate for each procedure, and analyzed the cause of failure, additional treatment method for failure, influential factors of treatment outcome, and complications. Results: The most common causes of iatrogenic pneumothorax were presented as percutaneous needle aspiration(PCNA) in 48 cases (45.7%), and central venous catheterization in 26 cases (24.8%). The mean interval to thoracostomy after the procedure was measured as 5.2 hours (1~34 hours). Total success rate of thoracostomy was 78.1%. The success rate was not significantly difference by tube type, with 7 F central venous catheter as 80%, 10 F trocar catheter as 81.6%, and 12 F pigtail catheter as 71%. Twenty one out of 23 patients that had failed with small bore catheter treatment added large bore conventional thoracostomy, and another 2 patients received surgery. The causes for treatment failure were presented as continuous air leakage in 12 cases (52.2%) and tube malfunction in 7 cases (30%). The causes for failure did not present significant differences by tube type. Statistically significant factors affecting treatment performance were not discovered. Conclusion: Closed thoracostomy with small bore catheter proved to be effective for iatrogenic pneumothorax. The success rate was not difference for each type. However, it is important to select the appropriate catheter by considering the patient status, pneumothorax aspect, and medical personnel in the cardiothoracic surgery department of the relevant hospital.

주증기계통 오리피스 후단 소구경 배관의 감육 및 누설 발생 (Cause Analysis for the Wall Thinning and Leakage of a Small Bore Piping Downstream of an Orifice)

  • 황경모
    • Corrosion Science and Technology
    • /
    • 제12권5호
    • /
    • pp.227-232
    • /
    • 2013
  • A number of components installed in the secondary system of nuclear power plants are exposed to aging mechanisms such as FAC (Flow-Accelerated Corrosion), Cavitation, Flashing, and LDIE (Liquid Droplet Impingement Erosion). Those aging mechanisms can lead to thinning of the components. In April 2013, one (1) inch small bore piping branched from the main steam line experienced leakage resulting from wall thinning in a 1,000 MWe Korean PWR nuclear power plant. During the normal operation, extracted steam from the main steam line goes to condenser through the small bore piping. The leak occurred in the downstream of an orifice. A control valve with vertical flow path was placed on in front of the orifice. This paper deals with UT (Ultrasonic Test) thickness data, SEM images, and numerical simulation results in order to analyze the extent of damage and the cause of leakage in the small bore piping. As a result, it is concluded that the main cause of the small bore pipe wall thinning is liquid droplet impingement erosion. Moreover, it is observed that the leak occurred at the reattachment point of the vortex flow in the downstream side of the orifice.

감육예측 및 수치해석 기법을 활용한 소구경 탄소강배관 감육영향 분석에 관한 연구 (Technology Based on Wall-Thinning Prediction and Numerical Analysis Techniques for Wall-Thinning Analysis of Small-Bore Carbon Steel Piping)

  • 이대영;황경모;진태은;박원;오동훈
    • 대한기계학회논문집B
    • /
    • 제34권4호
    • /
    • pp.429-435
    • /
    • 2010
  • 국내를 포함한 전 세계 50여개 원전의 발전사업자는 유동가속부식에 의한 탄소강 배관 감육을 관리하기 위하여 CHECWORKS 프로그램을 이용하고 있다. CHECWORKS 프로그램은 대구경 배관에만 적용 가능한 것으로 알려져 있기 때문에 소구경 배관에 대해서는 현장 배관감육 관리 담당자의 경험과 판단에 따라 배관을 관리하고 있다. 이에 따라 본 논문에서는 국내 원전 소구경 배관 4개 라인그룹에 대하여 CHECWORKS 프로그램과 FLUENT 코드를 이용하여 유동가속부식과 유동 특성을 분석하였다. 그 결과 현장 배관감육 관리 담당자의 기술력에 따라 CHEC- WORKS 프로그램도 소구경 배관 감육 관리에 이용할 수 있는 것으로 나타났다.

소구경 터널에 사용되는 SHOT PATCH용 모르타르의 특성 (Properties of the SHOT PATCH Mortar a Wet System for Small Bore Tunnels)

  • 정민철;전용희;정종익;박길수
    • 콘크리트학회논문집
    • /
    • 제11권6호
    • /
    • pp.121-128
    • /
    • 1999
  • The SHO PATCH System Mortar is a mortar shotcreting system which uses fairly small machine and equipment, and is applied for shotcrete tunnel linings, in particular for small bore tunnels of aqueducts by the TBM(Tunnel Boring Machine) method, and for reparing tunnels suffering from spring water and deterioration. This study shows the characteristics of the new mortar shotcreting system, the SHOT PATCh System Mortar, which exhibits excellent shotcrete performance.

소구경 터널에 사용되는 SHOT PATCH용 레미탈의 특성 (Properties of the SHOT Remitar a Wet System for Small Bore Tunnels)

  • 정민철;전용희;정종익;박길수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표대회 논문집(III)
    • /
    • pp.871-876
    • /
    • 1998
  • The SHOT PATCH System Remitar is a mortar shotcreting system which used fairly small machine and equipment, and is applied for shortcrete tunnel linings, in particular for small bore tunnels of aqueducts by the TBM(Tunnel Boring Machine) method, and for repairing tunnels suffering from spring water and deterioration. This study shows the characteristics of the new mortar shotcreting system, the SHOT PATCH System Remitar, which exhibits excellent shotcrete performance.

  • PDF

영상처리기법을 이용한 소화기 조준감사 자동화에 관한 연구 (A Study on the Bore-Sighting Automation for Small Arms Using the Image Processing)

  • 여운주
    • 한국군사과학기술학회지
    • /
    • 제9권3호
    • /
    • pp.5-11
    • /
    • 2006
  • This paper is launched to get an exact bore-sighting value in the process of assembling for a dual-barrel weapon. Image processing method with a CCD(Charged Coupled Device) camera is chosen for the error reduction of bore-sighting. The results of this method by using a CCD camera and the testing target method are described in this paper. After the performance of the dual-barrel weapon and that of the fire-control system in the dual barrel weapon system is confirmed, the bore-sighting which is a part of the process in the system assembly is accomplished. In this process, the position of the barrel is identified by using the testing target method that is an existing bore-sighting method. Then, the fixing line of the fire-control system is checked by a day-optical part. The precision of the bore-sighting is required within several mils, however the manual method using the naked eyes makes it worse. Therefore, a CCD camera is installed in the eyepieces. Next, we can get an image of the sighting and the center coordinate values of the laser-pointer from each barrel by image processing method. A required bore-sighting value is calculated from the eccentricity of the center coordinate. Finally, It can be applied to adopt this result in the assembling process of the dual-barrel weapon.

피스톤-링 및 실린더 보아 마모를 고려한 엔진오일소모 연구 (A Study on Engine Oil Consumption Considering Wear of Piston-Ring and Cylinder Bore)

  • 전상명
    • 한국자동차공학회논문집
    • /
    • 제15권2호
    • /
    • pp.143-150
    • /
    • 2007
  • Ring and cylinder bore wear may not be a problem in most current automotive engines. However, a small change in ring face and cylinder bore diameter can significantly affect the lubrication characteristics and ring axial motion. This in turn can cause to change inter-ring pressure, blow-by and oil consumption in an engine. Therefore, by predicting the wear of piston ring face and cylinder bore altogether, the changed ring end gap and the changed volume of gas reservoir can be calculated. Then the excessive oil consumption can be predicted. Here, the oil amount through top ring gap into combustion chamber is estimated as engine oil consumption. Furthermore, the wear theories of ring and cylinder bore are included. The changed oil consumption caused by the new end gap and the new volume of oil reservoir around second land, can be calculated at some engine running interval. Meanwhile, the wear amount and oil consumption occurred during engine durability cycle are compared with the calculated values. The wear data of rings and cylinder bore are obtained from three engines after engine durability test. The calculated wear data of each part are turn out to be around the band of averaged test values or a little below. It is shown that the important factor regarding oil consumption increasement is the wear of ring face.

적외선열화상 카메라를 이용한 원전 소구경 감육배관의 결함 검출 (Application Defects Detection in the Small-Bore Pipe Using Infrared Thermography Technique)

  • 윤경원;김동률;정현철;홍동표;김경석
    • 비파괴검사학회지
    • /
    • 제33권1호
    • /
    • pp.34-39
    • /
    • 2013
  • 선행 연구에서 적외선열화상기법을 이용하여 원전 배관의 감육 결함을 측정하기 위하여, 4 inch 배관에 인공결함을 가공하여 이에 대한 결함 검출을 도출하였다. 본 논문에서는 선행연구에서 도출된 조건을 이용하여 원전 소구경 배관의 결함 검출 조건에 관한 연구를 수행하였다. 결함의 가공은 감육 길이, 원주방향 각도, 감육 깊이를 변화시켜서 결함 조건을 가공하였다. 사용된 장비는 IR camera와 1 kW용량의 halogen lamp 2개를 사용하였으며, halogen lamp와 대상 배관과의 거리를 1 m, 1.5 m, 2 m 순으로 변화시켜 실험을 수행하였다. 실험 결과의 분석을 위하여 온도분포데이터를 확보하고, 이를 분석하여 결함 길이를 측정하였다. 4 inch 배관의 인공결함은 2 m에서 측정 결과의 신뢰도가 높았으나, 소구경 배관은 1.5 m에서 결함이 명확하게 검출되었다.

원자로냉각재계통 소구경 관통관 용접부 부분노즐교체 예방정비를 위한 최적 용접공정에 관한 연구 (Study on Optimal Welding Processes of Half Nozzle Repair on Small Bore Piping Welds in Reactor Coolant System)

  • 김영주;정광운;최광민;최동철;조상범;조홍석
    • 한국압력기기공학회 논문집
    • /
    • 제14권1호
    • /
    • pp.58-65
    • /
    • 2018
  • The purpose of this study is to develop a Half Nozzle Repair(HNR) process to prevent the leakage from welds on small bore piping in Reactor Coolant System. The Codes & Standards of tempered bead and design requirements of J-Groove welds are reviewed. Automatic machine GTAW welding and machining equipments are developed to perform HNR process. Single pass welding and overlay welding equipments are conducted in order to obtain the optimal temper bead welding process parameters with Alloy 52M filler wire. Coarse grain heat affected zone(CGHAZ) is formed by rapid cooling rate in heat affected zone after welding. Accordingly, a proper temper bead technique is required to reduce CGHAZ in 1-Layer of welds by 2- and 3-Layers. Mock-up tests show that the developed HNR process is possible to meet ASME Code & Standard requirements without any defect.

Efficacy and Cost-Effectiveness of Portable Small-Bore Chest Tube (Thoracic Egg Catheter) in Spontaneous Pneumothorax

  • Joh, Hyon Keun;Moon, Duk Hwan;Lee, Sungsoo
    • Journal of Chest Surgery
    • /
    • 제53권2호
    • /
    • pp.49-52
    • /
    • 2020
  • Background: Primary spontaneous pneumothorax is commonly treated with chest tube insertion, which requires hospitalization. In this study, we evaluated the efficacy, costs, and benefits of a portable small-bore chest tube (Thoracic Egg; Sumitomo Bakelite Co. Ltd., Tokyo, Japan) compared with a conventional chest tube. Methods: We retrospectively analyzed all primary spontaneous pneumothorax patients who underwent treatment at Gangnam Severance Hospital between August 2014 and May 2018. Results: A total of 279 patients were divided into 2 groups: the conventional group (n=236) and the Thoracic Egg group (n=43). Of the 236 patients in the conventional group, 100 were excluded because they underwent surgery during the study period. The efficacy and cost were compared between the 2 groups. There was no statistically significant difference between the groups regarding recurrence (conventional group, 36 patients [26.5%]; Thoracic Egg group, 15 patients [29.4%]; p=0.287). However, the Egg group had statistically significantly lower mean medical expenses than the conventional group (433,413 Korean won and 522,146 Korean won, respectively; p<0.001). Conclusion: Although portable small-bore chest tubes may not be significantly more efficacious than conventional chest tubes, their use is significantly less expensive. We believe that the Thoracic Egg catheter could be a less costly alternative to conventional chest tube insertion.