• Title/Summary/Keyword: SmBCO.

Search Result 50, Processing Time 0.021 seconds

Fabrication of Thick SmBCO/IBAD-MgO coated conductor (후막 SmBCO/IBAD-MgO 초전도 박막선재의 제조)

  • Lee, J.H.;Kang, D.K.;Ha, H.S.;Ko, R.K.;Oh, S.S.;Kim, H.K.;Yang, J.S.;Jung, S.W.;Moon, S.H.;Youm, D.;Kim, C.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.9-9
    • /
    • 2009
  • Coated conductor is required to have good critical current property for high efficiency of electric power applications. Until now, long coated conductor does not show high Jc over 3 MA/$cm^2$ in thick superconducting layer because of texture degradation by thick superconducting layer. In this study, in order to overcome this issue, thicker superconducting layer was deposited with optimized conditions to reduce the degradation of critical current density. SmBCO superconducting coated conductor was deposited with 1~3 um of thickness at $750\sim850^{\circ}C$ under 15~20 mTorr of oxygen partial pressure using batch type EDDC( evaporation using drum in dual chamber). The buffered substrate for superconducting layer deposition was used IBAD-MgO template with the architecture of $LaMnO_3/MgO/Y_2O_3/Al_2O_3$/Hastelloy. After fabrication of coated conductor, critical current was measured by 4-prove method under self-magnetic field and 77K. In addition, surface morphology and texture were analyzed by SEM and XRD, respectively. 3 um thick SmBCO coated conductor shows highest $I_C$ values of 638A/cm-w in 1 m long in the world.

  • PDF

A unhomogeneity of critical current at the long length coated conductors (Coated conductor에서 임계전류의 불균일)

  • Lee, Nam-Jin;Oh, Sang-Soo;Kim, Ho-Sup;Ha, Dong-Woo;Ha, Hong-Soo;Ko, Rock-Kil;Kim, Tae-Hyung;Moon, Seung-Hyun;Youm, Do-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.1-2
    • /
    • 2009
  • The high critical current ($I_c$, A) of SmBCO coated conductor in a magnetic field, the high production rate and the high material yield are promising for applications. The inhomogeneity of Ie at the long length coated conduct is very important problem for electric application. So we researched the reason of inhomogeneity of $I_c$ at long length tape prepared by batch type co-evaporation system called by EDDC. The long length SmBCO coated conductors were developed on $LaMnO_3/IBAD-MgO/Y_2O_3/Al_2O_3$/Hastelloy C276 template. The distribution of $I_c$ are from 0 to 397 A/cm at 77 K and self field. We have studied the microstructures of these films by using SEM, EDS and X-ray diffraction. The XRD and composition by EDS results of SmBCO film reveals subtle difference. But, the microscopic observation by SEM show the microcrack at the sample with low $I_c$.

  • PDF

Angular dependence of critical current of SmBCO coated conductor fabricated by co-evaporation method

  • Kim, Ho-Sup;Ha, Hong-Soo;Oh, Sang-Soo;Song, Kyu-Jeong;Ko, Rock-Kil;Ha, Dong-Woo;Kim, Tae-Hyung;Youm, Do-Jun;Lee, Nam-Jin;Moon, Seung-Hyun;Yoo, Sang-Im;Park, Chan
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.2
    • /
    • pp.16-19
    • /
    • 2008
  • Angular dependence of critical current density of SmBCO coated conductor fabricated by co-evaporation method was investigated. For comparison, three samples were fabricated by a co-evaporation method and one sample was fabricated by a pulsed laser deposition process. The deposition system, named EDDC (Evaporation using Drum in Dual Chambers), is a batch type co-evaporation system, which is composed of reaction chamber and evaporation chamber. The normalized critical current density ratio ($I_c/I_c$(H//ab-plane)) of EDDC-SmBCO samples was found to be higher than that of PLD-YBCO sample in the whole range of angle. While the EDDC-SmBCO samples evidently had a peak at the angle of H//c-axis in the plot of the angular dependence of critical current, the normalized critical current of PLD-YBCO sample decreased monotonically without any peak as angle increased. The field dependence of critical current under the magnetic field parallel to the normal direction of those samples showed similar aspect in the range of $0\;G{\sim}5000\;G$.

Fabrication of SmBCO superconducting coated conductor using 100m class batch-type co-evaporation method (100m 급 batch-type co-evaporation 증착장치를 이용한 SmBCO 초전도테이프 제조)

  • Kim, H.S.;Oh, S.S.;Ha, H.S.;Yang, J.S.;Kim, T.H.;Lee, N.J.;Jeong, Y.H.;Ko, R.K.;Song, K.J.;Ha, D.W.;Youm, D.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.24-25
    • /
    • 2006
  • SmBCO coated conductors were successfully fabricated using EDDC (Evaporation using Drum in Dual Chambers) deposition system that is a bath type co-evaporation system for fabrication of superconducting tape and divided into two chambers named evaporation chamber and reaction chamber. To obtain long and high quality superconducting coated conductor, it is very important to secure the uniformity of all the deposition parameters m the deposition system such as deposition temperature, oxygen partial pressure, compositional ratios and so on. Therefore, we investigated the distribution of the parameters along the axis of the drum m EDDC on which tapes were wound helically. When the temperature on the middle point of deposition zone was $700^{\circ}C$, that on the edge of deposition zone was $675^{\circ}C$. When the thickness of SmBCO layer on the middle point of deposition zone was 1063 nm, that on the edge of deposition zone was 899 nm. The partial pressure of oxygen was 5 mTorr in the reaction chamber while that was $7{\times}10^{-5}$Torr in the evaporation chamber. The composition ratio of Sm:Ba:Cu, that was measured by EDX, was very uniform along the axis of the drum. Under these deposition conditions, critical current distribution along the drum axis was 175 A/cm, 190A/cm, 217.5 A/cm, 182.5 A/cm, 175 A/cm with the interval of 9 cm between samples. It means that the EDDC system has the potential of fabricating (100m, 200A) class coated conductor.

  • PDF

Non-contact critical current measurement of superconducting coated conductor using Hall Probe (Hall Probe를 이용한 초전도선재의 비접촉 임계전류 측정 방법)

  • Kim, Ho-Sup;Oh, Sang-Soo;Lee, Nam-Jin;Ha, Dong-Woo;Baik, Seung-Kyu;Ko, Rock-Kil;Ha, Hong-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.12-12
    • /
    • 2010
  • The hall probe measurement system was used to measure the critical current distribution of superconducting coated conductor. The system consists of reel to reel moving apparatus, 7 array hall probe, a rotary encoder and permanent magnet. The magnetic field profile across the width of superconducting coated conductor using Bean's critical state model was calculated. The effect of various parameters of the formulas on the magnetic field distribution and the effect of shape and size of artificial defects, which were formed on the surface of SmBa2Cu3O7-d(SmBCO) coated conductor using laser marking system, on the hall probe magnetic field signal of the hall probe measurement system was investigated.

  • PDF

Effect of Bending Test Procedure on the Degradation Behavior of Critical Current in ReBCO Coated Conductor Tapes

  • Shin, H.S.;Dedicatoria, M.J.;Lee, N.J.;Oh, S.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.4
    • /
    • pp.12-15
    • /
    • 2009
  • The $I_c$ degradation behavior of critical current in differently processed YBCO and SmBCO CC tapes with IBAD template has been investigated. It has been known that the residual strain in the CC tape will influence the shape of the $I_c$-strain window; $I_c$ may show a peak value if there exist a residual strain induced in the tape during manufacturing. The difference of residual strain may be resulted from the adopted different deposition techniques. In this study, bending test of CC tapes has been done using the Goldacker bending test rig which can produce both compressive and tensile bending strain continuously or alternately to the sample. For SmBCO CC tapes, in continuous compressive bending test, $I_c$ showed a minimal increase and did not degrade up to the largest strain that can be applied using the bending rig equivalent to 1.15% based on the sample thickness. However, in the case of alternate application of compressive and tensile bending strain, $I_c$ showed a larger degradation and a lower reversible limit when compared with the case of continuous application of the bending strain. When $I_c$ started to degrade significantly at the tension side, the reversibility ended, also at the compression side which is resulted from the permanent deformation like delamination or cracks that was induced due to tensile bending strain.

Measurement and Analysis of the Flux Profiles of the Coated Conductors using Magneto-optical Image and Scanning Hall Probe (Coated conductor에서 magneto-optical image와 scanning hall probe를 이용한 flux profile의 측정 및 분석)

  • Lee, H.Y.;Kwak, K.S.;Rhyee, J.K.;Yoo, J.;Youm, D.
    • Progress in Superconductivity
    • /
    • v.11 no.2
    • /
    • pp.128-134
    • /
    • 2010
  • The magnetic flux profiles in SmBCO and YBCO coated conductors(CC) in the presence of the external field were comparatively investigated by magneto-optic image and scanning hall probe measurements. The current distributions calculated by using the inversion method from measured field profiles show that the decrease of current densities near the edges of SmBCO CC is more significant than those of YBCO CC. Through the comparison of the numerical analysis based on Kim's critical state model and the Brandt and Indenbom's solution, we found that this feature is related to their different field dependant properties of the critical current densities.